953 resultados para shear stiffness
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The problem of shock generated vibration is very common in practice and difficult to isolate due to the high levels of excitation involved and its transient nature. If not properly isolated it could lead to large transmitted forces and displacements. Typically, classical shock isolation relies on the use of passive stiffness elements to absorb energy by deformation and some damping mechanism to dissipate residual vibration. The approach of using nonlinear stiffness elements is explored in this paper, focusing in providing an isolation system with low dynamic stiffness. The possibilities of using such a configuration for a shock mount are studied experimentally following previous theoretical models. The model studied considers electromagnets and permanent magnets in order to obtain nonlinear stiffness forces using different voltage configurations. It is found that the stiffness nonlinearities could be advantageous in improving shock isolation in terms of absolute displacement and acceleration response when compared with linear elastic elements. Copyright (C) 2015 Elsevier Ltd. All rights reserved
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
BACKGROUND: Hypertension is the most prevalent comorbidity after heart transplantation (HT). Exercise training (ET) is widely recommended as a key non-pharmacologic intervention for the prevention and management of hypertension, but its effects on ambulatory blood pressure (ABP) and some mechanisms involved in the pathophysiology of hypertension have not been studied in this population. The primary purpose of this study was to investigate the effects of ET on ABP and arterial stiffness of HT recipients.METHODS: 40 HT patients, randomized to ET (n = 31) or a control group (n = 9) underwent a maximal graded exercise test, 24-hour ABP monitoring, and carotid-femoral pulse wave velocity (PWV) assessment before the intervention and at a 12-week follow-up assessment. The ET program was performed thrice-weekly and consisted primarily of endurance exercise (40 minutes) at similar to 70% of maximum oxygen uptake (Vo(2MAX))RESULTS: The ET group had reduced 24-hour (4.0 +/- 1.4 mm Hg, p < 0.01) and daytime (4.8 +/- 1.6 mm Hg, p < 0.01) systolic ABP, and 24-hour (7.0 +/- 1.4 mm Hg, p < 0.001) daytime (7.5 +/- 1.6 mm Hg, p < 0.001) and nighttime (5.9 +/- 1.5 mm Hg, p < 0.001) diastolic ABP after the intervention. The ET group also had improved Vo(2MAX) (9.7% +/- 2.6%, p < 0.001) after the intervention. However, PWV did not change after ET. No variable was changed in the control group after the intervention.CONCLUSIONS: The 12-week ET program was effective for reducing ABP but not PWV in heart transplant recipients. This result suggesfs that endurance ET may be a tool to counteract hypertension in this high-risk population. (C) 2015 International Society for Heart and Lung Transplantation. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Introduction: Based on the importance of the integrity of the metal/ceramic interface, the purpose of this work was to evaluate the shear bond strength of the metal-ceramic union of two Co-Cr alloys (Wirobond C, Bego; Remanium 2000, Dentaurum) combined with Omega 900 ceramic (Vita Zahnfabrik). Material and Method: Eleven cylindrical matrixes were made for each alloy, and the metallic portion was obtained with the lost wax casting technique with standardized waxing of 4mm of height and of 4mm of diameter. The ceramic was applied according to the manufacturer's recommendations with the aid of a teflon matrix that allowed its dimension to be standardized in the same size as the metallic portion. The specimens were submitted to the shear bond test in an universal testing machine (EMIC), with the aid of a device developed for such intention, and constant speed of 0.5mm/min. Results and Conclusions: The mean resistance was 48.387MPa for Wirobond C alloy, with standard deviation of 17.718, and 55.956MPa for Remanium 2000, with standard deviation of 17.198. No statistically significant difference was observed between the shear strength of the two metal-ceramic alloys.
Resumo:
This study aimed to investigate the influence of storage time (0, 48 hours) of Pinus elliottii pieces and the tests to obtaining modulus of elasticity (static bending and transversal vibration) in glued laminated timber beams, produced with resorcinol based adhesive and 0.8 MPa compaction pressure. After pieces were properly prepared, part of them was used in immediate three manufacturing glulam beams, tested after adhesive cure, and part stored for 48 hours under a roof with a temperature of 25°C and relative humidity of 60% for subsequent manufacturing and testing three other glulam beams. Results of analysis of variance (ANOVA) revealed that the storage period was significant influence in modulus of elasticity obtained in static bending test (8% reduction from 0 to 48 hours). This not occurred with modulus of elasticity obtained by transversal vibration test (no significant influence). ANOVA results showed equivalence of means in both test procedures. New researches ire needed to better understand the investigated phenomenon, using new wood species, other storage conditions and a great number of samples.
Resumo:
This study focuses on analysing the effects of nonlinear torsional stiffness on the dynam-ics of a slender elastic beam under torsional oscillations, which can be subject to helical buckling.The helical buckling of an elastic beam confined in a cylinder is relevant to many applications. Someexamples include oil drilling, medical cateters and even the conformation and functioning of DNAmolecules. A recent study showed that the formation of the helical configuration is a result of onlythe torsional load, confirming that there is a different path to helical buckling which is not related tothe sinusoidal buckling, stressing the importance of the geometrical behaviour of the beam. A lowdimensional model of an elastic beam under torsional oscillations is used to analyse its dynamical be-haviour with different stiffness characteristics, which are present before and after the helical buckling.Hardening and softening characteristics are present, as the effects of torsion and bending are coupled.With the use of numerical algorithms applied to nonlinear dynamics, such as bifurcation diagramsand basins of attraction, it is shown that the nonlinear stiffness can shift the bifurcations and inducechanges in the stability of the desirable and undesirable solutions. Therefore, the proper modellingof these stiffness nonlinearities seems to be important for a better understanding of the dynamicalbehaviour of such beams.
Resumo:
The tests used to obtain the stiffness properties of wood are made with two loading cycles, as defined by the Brazilian standard ABNT NBR 7190 (Design of Timber Structures). However, the possibility of reducing the number of cycles allows decrease the operating time of the machine, resulting in reduced spending on electricity used during the tests. This research aimed to investigate, with the aid of the analysis of variance (ANOVA), the influence of the use of three load cycles to obtain the modulus of elasticity in compression parallel to grain (Ec0), in tensile parallel to the grain (Et0), in bending (Em) and in compression perpendicular to the grain (Ec90) of Angico Preto (Anadenanthera macrocarpa) wood specie. For the number of cycles and stiffness were manufactured 12 samples, totaling 144 specimens. The results of the ANOVA revealed statistical equivalence between the stiffness properties for both load cycle numbers evaluated, indicating that it is possible to carry out the tests with a single charge cycle, allowing savings in time and energy in the operation of the equipment.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Degeneration of tendon tissue is a common cause of tendon dysfunction with the symptoms of repeated episodes of pain and palpable increase of tendon thickness. Tendon mechanical properties are directly related to its physiological composition and the structural organization of the interior collagen fibers which could be altered by tendon degeneration due to overuse or injury. Thus, measuring mechanical properties of tendon tissue may represent a quantitative measurement of pain, reduced function, and tissue health. Ultrasound elasticity imaging has been developed in the last two decades and has proved to be a promising tool for tissue elasticity imaging. To date, however, well established protocols of tendinopathy elasticity imaging for diagnosing tendon degeneration in early stages or late stages do not exist. This thesis describes the re-creation of one dynamic ultrasound elasticity imaging method and the development of an ultrasound transient shear wave elasticity imaging platform for tendon and other musculoskeletal tissue imaging. An experimental mechanical stage with proper supporting systems and accurate translating stages was designed and made. A variety of high-quality tissue-mimicking phantoms were made to simulate homogeneous and heterogeneous soft tissues as well as tendon tissues. A series of data acquisition and data processing programs were developed to collect the displacement data from the phantom and calculate the shear modulus and Young’s modulus of the target. The imaging platform was found to be capable of conducting comparative measurements of the elastic parameters of the phantoms and quantitatively mapping elasticity onto ultrasound B-Mode images. This suggests the system has great potential for not only benefiting individuals with tendinopathy with an earlier detection, intervention and better rehabilitation, but also for providing a medical tool for quantification of musculoskeletal tissue dysfunction in other regions of the body such as the shoulder, elbow and knee.
Resumo:
Background: Highly active antiretroviral therapy for AIDS is known to increase cardiovascular risk, but the effects of potent antiretroviral agents according to gender are unknown. Objective: The present study evaluated the impact of HIV infection treatment on aortic stiffness according to gender. Methods: From university-affiliated hospitals, we recruited 28 AIDS patients undergoing highly active antiretroviral treatment (HAART), 28 treatment-naive HIV-infected patients, 44 patients with type 2 diabetes, and 30 controls. Aortic stiffness was determined by measuring pulse wave velocity (PWV) using a validated and non-invasive automatic device. Results: The crude mean PWV values and 95% confidence intervals (95% CI) for HAART, diabetics, and controls were 9.77 m/s (95% CI 9.17-10.36),, 9.00 m/s (95% CI 8.37-9.63), 9.90 m/s (95% CI 9.32-10.49), and 9.28 m/s (95% CI 8.61-9.95), respectively, for men (P-value for trend = 0.14), and 9.61 m/s (95% CI 8.56-10.66), 8.45 m/s (95% CI 7.51-9.39), 9.83 (95% CI 9.21-10.44), and 7.79 m/s (95% CI 6.99-8.58), respectively, for women (P-value for trend <0.001). Post-hoc analysis revealed a significant difference between the mean PWV values in the HAART group and controls in women (P-value <0.01). After adjusting for other potential covariates, including systolic blood pressure and diabetes, these results did not change. The findings indicate that the impact of HAART treatment on aortic stiffness was amplified in women with hypertension, dyslipidemia, and metabolic syndrome. Conclusion: Potent anti-retroviral agents used in the treatment of HIV infection increases aortic stiffness, mainly among women with higher cardiovascular risk. (Arq Bras Cardiol 2012;99(6):1100-1107)