993 resultados para sequential methods
Resumo:
Respiratory virus infections are the main cause of infant hospitalization and are potentially severe in children with congenital heart disease (CHD). Rapid and sensitive diagnosis is very important to early introduction of antiviral treatment and implementation of precautions to control transmission, reducing the risk of nosocomial infections. In the present study we compare different techniques in the diagnosis of respiratory viruses in CHD infants. Thirty-nine samples of nasopharyngeal aspirate were obtained from CHD infants with symptoms of respiratory infection. The Multiplex PCR (Seeplex® RV 12 ACE Detection) driven to the detection of 12 respiratory viruses was compared with the direct immunofluorescence assay (DFA) and PCR, both targeting seven respiratory viruses. The positivity found by DFA, Multiplex and PCR was 33.3%, 51.3% and 48.7%, respectively. Kappa index comparing DFA and Multiplex, DFA and PCR and PCR and Multiplex PCR was 0.542, 0.483 and 0.539, respectively. The concordance between techniques was considered moderate. Both Multiplex PCR (p = 0.001) and PCR (p = 0.002) detected significantly more respiratory virus than DFA. As the performance of the tests may vary, the combination of two or more techniques may increase diagnostic sensitivity favoring the diagnosis of co-infections, early introduction of antiviral therapy and implementation of appropriate measures.
Resumo:
OBJECTIVES: Mortality after ICU discharge accounts for approx. 20-30% of deaths. We examined whether post-ICU discharge mortality is associated with the presence and severity of organ dysfunction/failure just before ICU discharge. PATIENTS AND METHODS: The study used the database of the EURICUS-II study, with a total of 4,621 patients, including 2,958 discharged alive to the general wards (post-ICU mortality 8.6%). Over a 4-month period we collected clinical and demographic characteristics, including the Simplified Acute Physiology Score (SAPS II), Nine Equivalents of Nursing Manpower Use Score, and Sequential Organ Failure Assessment (SOFA) score. RESULTS: Those who died in the hospital after ICU discharge had a higher SAPS II score, were more frequently nonoperative, admitted from the ward, and had stayed longer in the ICU. Their degree of organ dysfunction/failure was higher (admission, maximum, and delta SOFA scores). They required more nursing workload resources while in the ICU. Both the amount of organ dysfunction/failure (especially cardiovascular, neurological, renal, and respiratory) and the amount of nursing workload that they required on the day before discharge were higher. The presence of residual CNS and renal dysfunction/failure were especially prognostic factors at ICU discharge. Multivariate analysis showed only predischarge organ dysfunction/failure to be important; thus the increased use of nursing workload resources before discharge probably reflects only the underlying organ dysfunction/failure. CONCLUSIONS: It is better to delay the discharge of a patient with organ dysfunction/failure from the ICU, unless adequate monitoring and therapeutic resources are available in the ward.
Resumo:
Methicillin-resistant Staphylococcus aureus (MRSA) are now a worldwide problem. Cystic fibrosis (CF) patients are commonly colonized and infected by MRSA. Accurate oxacillin susceptibility testing is mandatory for the adequate management of these patients. We performed a comparison of the accuracy of different tests in CF isolates, including methicillin-susceptible S. aureus and MRSA with different SCCmec types, and using the mecA gene as the gold-standard. The sensitivity and specificity of oxacillin disc, Etest, and oxacillin agar screening plate were 100%. Sensitivity of the cefoxitin disc was 85% and specificity was 100%. For clinically relevant isolates, laboratories may consider the use of a combination of two phenotypic methods.
Resumo:
Asymptomatic Plasmodium infection is a new challenge for public health in the American region. The polymerase chain reaction (PCR) is the best method for diagnosing subpatent parasitemias. In endemic areas, blood collection is hampered by geographical distances and deficient transport and storage conditions of the samples. Because DNA extraction from blood collected on filter paper is an efficient method for molecular studies in high parasitemic individuals, we investigated whether the technique could be an alternative for Plasmodium diagnosis among asymptomatic and pauciparasitemic subjects. In this report we compared three different methods (Chelex®-saponin, methanol and TRIS-EDTA) of DNA extraction from blood collected on filter paper from asymptomatic Plasmodium-infected individuals. Polymerase chain reaction assays for detection of Plasmodium species showed the best results when the Chelex®-saponin method was used. Even though the sensitivity of detection was approximately 66% and 31% for P. falciparum and P. vivax, respectively, this method did not show the effectiveness in DNA extraction required for molecular diagnosis of Plasmodium. The development of better methods for extracting DNA from blood collected on filter paper is important for the diagnosis of subpatent malarial infections in remote areas and would contribute to establishing the epidemiology of this form of infection.
Resumo:
Dissertação apresentada como requisito parcial para obtenção do grau de Mestre em Estatística e Gestão de Informação
Resumo:
Currently there are several methods to extract bacterial DNA based on different principles. However, the amount and the quality of the DNA obtained by each one of those methods is highly variable and microorganism dependent, as illustrated by coagulase-negative staphylococci (CoNS) which have a thick cell wall that is difficult to lyse. This study was designed to compare the quality and the amount of CoNS DNA, extracted by four different techniques: two in-house protocols and two commercial kits. DNA amount and quality determination was performed through spectrophotometry. The extracted DNA was also analyzed using agarose gel electrophoresis and by PCR. 267 isolates of CoNS were used in this study. The column method and thermal lyses showed better results with regard to DNA quality (mean ratio of A260/280 = 1.95) and average concentration of DNA (), respectively. All four methods tested provided appropriate DNA for PCR amplification, but with different yields. DNA quality is important since it allows the application of a large number of molecular biology techniques, and also it's storage for a longer period of time. In this sense the extraction method based on an extraction column presented the best results for CoNS.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
INTRODUCTION: Methicillin-Resistant Staphylococcus aureus (MRSA) presenting reduced susceptibility to vancomycin has been associated to therapeutic failure. Some methods used by clinical laboratories may not be sufficiently accurate to detect this phenotype, compromising results and the outcome of the patient. OBJECTIVES: To evaluate the performance of methods in the detection of vancomycin MIC values among clinical isolates of MRSA. MATERIAL AND METHODS: The Vancomycin Minimal Inhibitory Concentration was determined for 75 MRSA isolates from inpatients of Mãe de Deus Hospital, Porto Alegre, Brazil. The broth microdilution (BM) was used as the gold-standard technique, as well as the following methods: E-test® strips (BioMérieux), M.I.C.E® strips (Oxoid), PROBAC® commercial panel and the automated system MicroScan® (Siemens). Besides, the agar screening test was carried out with 3 µg/mL of vancomycin. RESULTS: All isolates presented MIC ≤ 2 µg/mL for BM. E-test® had higher concordance (40%) in terms of global agreement with the gold standard, and there was not statistical difference among E-test® and broth microdilution results. PROBAC® panels presented MICs, in general, lower than the gold-standard panels (58.66% major errors), while M.I.C.E.® MICs were higher (67.99% minor errors). CONCLUSIONS: For the population of MRSA in question, E-test® presented the best performance, although with a heterogeneous accuracy, depending on MIC values.
Resumo:
SUMMARY Infection by Candidaspp. is associated with high mortality rates, especially when treatment is not appropriate and/or not immediate. Therefore, it is necessary to correctly identify the genus and species of Candida. The aim of this study was to compare the identification of 89 samples of Candida spp. by the manual methods germ tube test, auxanogram and chromogenic medium in relation to the ID 32C automated method. The concordances between the methods in ascending order, measured by the Kappa index were: ID 32C with CHROMagar Candida(κ = 0.38), ID 32C with auxanogram (κ = 0.59) and ID 32C with germ tube (κ = 0.9). One of the species identified in this study was C. tropicalis,which demonstrated a sensitivity of 46.2%, a specificity of 95.2%, PPV of 80%, NPV of 81.1%, and an accuracy of 80.9% in tests performed with CHROMagar Candida;and a sensitivity of 76.9%, a specificity of 96.8%, PPV of 90.9%, NPV of 91%, and an accuracy of 91% in the auxanogram tests. Therefore, it is necessary to know the advantages and limitations of methods to choose the best combination between them for a fast and correct identification of Candidaspecies.
Resumo:
Clinically childhood occipital lobe epilepsy (OLE) manifests itself with distinct syndromes. The traditional EEG recordings have not been able to overcome the difficulty in correlating the ictal clinical symptoms to the onset in particular areas of the occipital lobes. To understand these syndromes it is important to map with more precision the epileptogenic cortical regions in OLE. Experimentally, we studied three idiopathic childhood OLE patients with EEG source analysis and with the simultaneous acquisition of EEG and fMRI, to map the BOLD effect associated with EEG spikes. The spatial overlap between the EEG and BOLD results was not very good, but the fMRI suggested localizations more consistent with the ictal clinical manifestations of each type of epileptic syndrome. Since our first results show that by associating the BOLD effect with interictal spikes the epileptogenic areas are mapped to localizations different from those calculated from EEG sources and that by using different EEG/fMRI processing methods our results differ to some extent, it is very important to compare the different methods of processing the localization of activation and develop a good methodology for obtaining co-registration maps of high resolution EEG with BOLD localizations.
Resumo:
Trichomonas vaginalis is the etiologic agent of trichomoniasis, the most common non-viral sexually transmitted disease (STD) in the world. The diagnosis is based on wet mount preparation and direct microscopy on fixed and stained clinical specimens. The aim of this study was to compare the performance of different fixing and staining techniques used in the detection of T. vaginalis in urine. The smears were fixed and submitted to different methods of permanent staining and then, the morphological aspects of the parasites were analyzed and compared. The Papanicolaou staining with ethanol as the fixative solution showed to be the best method of permanent staining. Our data suggest that staining techniques in association with wet mount examination of fresh specimens contribute to increase the sensitivity in the diagnosis of trichomoniasis.
Resumo:
Dissertação apresentada para obtenção do Grau de Doutor em Engenharia do Ambiente, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia
Resumo:
Através da prova de 7 dias foi estudado o grau de resistência do Plasmodium falciparum à cloroquina, amodiaquina e sulfadoxina-pirimetamina em Porto Velho, Estado de Rondônia, Brasil. Não se observaram diferenças significativas nas médias de parasitas nos dias de seguimento e nas proporções de resistência entre os três medicamentos testados, fazendo com que os autores recomendem a manutenção das 4-aminoquinoleínas como drogas a serem usadas atualmente em infecções não graves por P. falciparum na área de Porto Velho.
Resumo:
21th Annual Conference of the International Group for Lean Construction (IGLC 21), July 2013, Fortaleza, Brazil
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores