960 resultados para pulsed flame photometric detector


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A bit-level processing (BLP) based linear CDMA detector is derived following the principle of minimum variance distortionless response (MVDR). The combining taps for the MVDR detector are determined from (1) the covariance matrix of the matched filter output, and (2) the corresponding row (or column) of the user correlation matrix. Due to the interference suppression capability of MVDR and the fact that no inversion of the user correlation matrix is involved, the influence of the synchronisation errors is greatly reduced. The detector performance is demonstrated via computer simulations (both synchronisation errors and intercell interference are considered).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a three-shot improvement scheme for the hard-decision based method (HDM), an implementation solution for linear decorrelating detector (LDD) in asynchronous DS/CDMA systems. By taking advantage of the preceding (already reconstructed) bit and the matched filter output for the following two bits, the coupling between temporally adjacent bits (TABs), which always exists for asynchronous systems, is greatly suppressed and the performance of the original HDM is substantially improved. This new scheme requires no signaling overhead yet offers nearly the same performance as those more complicated methods. Also, it can easily accommodate the change in the number of active users in the channel, as no symbol/bit grouping is involved. Finally, the influence of synchronisation errors is investigated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Greater attention has been focused on the use of CDMA for future cellular mobile communications. CA near-far resistant detector for asynchronous code-division multiple-access (CDMA) systems operating in additive white Gaussian noise (AWGN) channels is presented. The multiuser interference caused by K users transmitting simultaneously, each with a specific signature sequence, is completely removed at the receiver. The complexity of this detector grows only linearly with the number of users, as compared to the optimum multiuser detector which requires exponential complexity in the number of users. A modified algorithm based on time diversity is described. It performs detection on a bit-by-bit basis and overcomes the complexity of using a sequence detector. The performance of this detector is shown to be superior to that of the conventional receiver.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper investigates the effect of time offset errors on the partial parallel interference canceller (PIC) and compares the performance of it against that of the standard PIC. The BER performances of the standard and partial interference cancellers are simulated in a near far environment with varying time offset errors. These simulations indicate that whilst timing errors significantly affect the performance of both these schemes, they do not diminish the gains that are realised by the partial PIC over that of the standard PIC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of terrestrial television multipath signals on the intermediate frequency (IF) vestigial sideband filter and the video detector are discussed. A new detector is proposed which, by processing the detected phase quadrature information, derives the correct phase for synchronous detection in the presence of multipath effects. This minimizes dispersion and produces a detected video signal with the linear addition of any ghosts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Under multipath conditions, video intermediate frequency (VIF) detectors may generate a local oscillator phase error and consequently produce a dispersed detected signal due to the presence of additional IF carriers. A new detector is presented which by processing the detected phase quadrature information, derives the correct phase for synchronous detection in the presence of multipath effects. This minimises dispersion and produces a detected video signal with the linear addition of amplitude scaled ghosts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adaptive filters used in code division multiple access (CDMA) receivers to counter interference have been formulated both with and without the assumption of training symbols being transmitted. They are known as training-based and blind detectors respectively. We show that the convergence behaviour of the blind minimum-output-energy (MOE) detector can be quite easily derived, unlike what was implied by the procedure outlined in a previous paper. The simplification results from the observation that the correlation matrix determining convergence performance can be made symmetric, after which many standard results from the literature on least mean square (LMS) filters apply immediately.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel but simple time-of-flight neutron scattering geometry which allows structural anisotropy to be probed directly, simultaneously and thus unambiguously in polymeric and other materials is described. A particular advantage of the simultaneous data collection when coupled to the large area of the beam is that it enables thin films (< 10 μm < 10 mg) to be studied with relative ease. The utility of the technique is illustrated by studies on both deformed poly(styrene) glasses and on thin films of electrical conducting polymers. In the latter case, the power of isotopic substitution is illustrated to great effect. The development of these procedures for use in other areas of materials science is briefly discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two genetic fingerprinting techniques, pulsed-field gel electrophoresis (PFGE) and ribotyping, were used to characterize 207 Escherichia coli O157 isolates from food animals, foods of animal origin, and cases of human disease (206 of the isolates were from the United Kingdom). In addition, 164 of these isolates were also phage typed. The isolates were divided into two general groups: (i) unrelated isolates not known to be epidemiologically linked (n = 154) and originating from food animals, foods and the environment, or humans and (ii) epidemiologically related isolates (n = 53) comprised of four related groups (RGs) originating either from one farm plus the abattoir where cattle from that farm were slaughtered or from one of three different English abattoirs. PFGE was conducted with the restriction endonuclease XbaI. while for ribotyping, two restriction endonucleases (PstI and SphI) were combined to digest genomic DNAs simultaneously. The 207 E. coli O157 isolates produced 97 PFGE profiles and 51 ribotypes. The two genetic fingerprinting methods had similar powers to discriminate the 154 epidemiologically unrelated E. coli O157 isolates in the study (Simpson's index of diversity [D] = 0.98 and 0.94 for PFGE typing and ribotyping, respectively). There was no correlation between the source of an isolate (healthy meat or milk animals, retail meats, or cases of human infection) and either particular PFGE or ribotype profiles or clusters. Combination of the results of both genetic fingerprinting methods produced 146 types, significantly more than when either of the two methods was used individually. Consequently, the superior discriminatory performance of the PFGE-ribotyping combination was proven in two ways: (i) by demonstrating that the majority of the E. coli O157 isolates with unrelated histories were indeed distinguishable types and (ii) by identifying some clonal groups among two of the four RGs of E. coli O157 isolates (comprising PFGE types different by just one or two bands), the relatedness of which would have remained unconfirmed otherwise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An in vitro colon extended physiologically based extraction test (CEPBET) which incorporates human gastrointestinal tract (GIT) parameters (including pH and chemistry, solid-to-fluid ratio, mixing and emptying rates) was applied for the first time to study the bioaccessibility of brominated flame retardants (BFRs) from the 3 main GIT compartments (stomach, small intestine and colon) following ingestion of indoor dust. Results revealed the bioaccessibility of γ-HBCD (72%) was less than that for α- and β-isomers (92% and 80% respectively) which may be attributed to the lower aqueous solubility of the γ-isomer (2 μg L−1) compared to the α- and β-isomers (45 and 15 μg L−1 respectively). No significant change in the enantiomeric fractions of HBCDs was observed in any of the studied samples. However, this does not completely exclude the possibility of in vivo enantioselective absorption of HBCDs, as the GIT cell lining and bacterial flora – which may act enantioselectively – are not included in the current CE-PBET model. While TBBP-A was almost completely (94%) bioaccessible, BDE-209 was the least (14%) bioaccessible of the studied BFRs. Bioaccessibility of tri-hepta BDEs ranged from 32–58%. No decrease in the bioaccessibility with increasing level of bromination was observed in the studied PBDEs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a novel approach to the automatic classification of very large data sets composed of terahertz pulse transient signals, highlighting their potential use in biochemical, biomedical, pharmaceutical and security applications. Two different types of THz spectra are considered in the classification process. Firstly a binary classification study of poly-A and poly-C ribonucleic acid samples is performed. This is then contrasted with a difficult multi-class classification problem of spectra from six different powder samples that although have fairly indistinguishable features in the optical spectrum, they also possess a few discernable spectral features in the terahertz part of the spectrum. Classification is performed using a complex-valued extreme learning machine algorithm that takes into account features in both the amplitude as well as the phase of the recorded spectra. Classification speed and accuracy are contrasted with that achieved using a support vector machine classifier. The study systematically compares the classifier performance achieved after adopting different Gaussian kernels when separating amplitude and phase signatures. The two signatures are presented as feature vectors for both training and testing purposes. The study confirms the utility of complex-valued extreme learning machine algorithms for classification of the very large data sets generated with current terahertz imaging spectrometers. The classifier can take into consideration heterogeneous layers within an object as would be required within a tomographic setting and is sufficiently robust to detect patterns hidden inside noisy terahertz data sets. The proposed study opens up the opportunity for the establishment of complex-valued extreme learning machine algorithms as new chemometric tools that will assist the wider proliferation of terahertz sensing technology for chemical sensing, quality control, security screening and clinic diagnosis. Furthermore, the proposed algorithm should also be very useful in other applications requiring the classification of very large datasets.