996 resultados para ocular imaging instruments


Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: q-Space-based techniques such as diffusion spectrum imaging, q-ball imaging, and their variations have been used extensively in research for their desired capability to delineate complex neuronal architectures such as multiple fiber crossings in each of the image voxels. The purpose of this article was to provide an introduction to the q-space formalism and the principles of basic q-space techniques together with the discussion on the advantages as well as challenges in translating these techniques into the clinical environment. A review of the currently used q-space-based protocols in clinical research is also provided.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The functional architecture of the occipital cortex is being studied with increasing detail. Functional and structural MR based imaging are altering views about the organisation of the human visual system. Recent advances have ranged from comparative studies with non-human primates to predictive scanning. The latter multivariate technique describes with sub-voxel resolution patterns of activity that are characteristic of specific visual experiences. One can deduce what a subject experienced visually from the pattern of cortical activity recorded. The challenge for the future is to understand visual functions in terms of cerebral computations at a mesoscopic level of description and to relate this information to electrophysiology. The principal medical application of this new knowledge has focused to a large extent on plasticity and the capacity for functional reorganisation. Crossmodality visual-sensory interactions and cross-correlations between visual and other cerebral areas in the resting state are areas of considerable current interest. The lecture will review findings over the last two decades and reflect on possible roles for imaging studies in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'implant d’una lent intraocular fàquica tipus ICL (Implantable Collamer Lens) pot produir glaucoma agut per tancament angular degut a un bloqueig pupil•lar amb el consegüent augment de la pressió intraocular, el mecanisme i epidemiologia del qual no són ben coneguts. Aquest estudi preliminar pretén avaluar la incidència d'hipertensió ocular i glaucoma agut per tancament angular degut a bloqueig pupil·lar després de l'implant d'una lent posterior fàquica tipus ICL i plantejar hipòtesis sobre el seu mecanisme fisiopatològic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent years have seen widespread experimentation with market-based instruments (MBIs) for the provision of environmental goods and ecosystem services. However, little attention has been paid to their design or to the effects of the underlying pro-market narrative on environmental policy instruments. The purpose of this article is to analyze the emergence and dissemination of the term "market-based instruments" applied to the provision of environmental services and to assess to what extent the instruments associated are genuinely innovative. The recommendation to develop markets can lead in practice to a variety of institutional forms, as we show it based on the example of payments for environmental services (PES) and biodiversity offsets, two very different mechanisms that are both presented in the literature as MBIs. Our purpose is to highlight the gap between discourse and practice in connection with MBIs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Elderly individuals display a rapid age-related increase in intraindividual variability (IIV) of their performances. This phenomenon could reflect subtle changes in frontal lobe integrity. However, structural studies in this field are still missing. To address this issue, we computed an IIV index for a simple reaction time (RT) task and performed magnetic resonance imaging (MRI) including voxel based morphometry (VBM) and the tract based spatial statistics (TBSS) analysis of diffusion tensor imaging (DTI) in 61 adults aged from 22 to 88 years. The age-related IIV increase was associated with decreased fractional anisotropy (FA) as well as increased radial (RD) and mean (MD) diffusion in the main white matter (WM) fiber tracts. In contrast, axial diffusion (AD) and grey matter (GM) densities did not show any significant correlation with IIV. In multivariate models, only FA has an age-independent effect on IIV. These results revealed that WM but not GM changes partly mediated the age-related increase of IIV. They also revealed that the association between WM and IIV could not be only attributed to the damage of frontal lobe circuits but concerned the majority of interhemispheric and intrahemispheric corticocortical connections.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high-resolution three-dimensional (3-D) seismic reflection survey was conducted in Lake Geneva, near the city of Lausanne, Switzerland, as part of a project for developing such seismic techniques. Using a single 48-channel streamer, the 3-D site with an area of 1200 m x 600 m was surveyed in 10 days. A variety of complex geologic structures (e.g. thrusts, folds, channel-fill) up to similar to150 m below the water bottom were obtained with a 15 in.(3) water gun. The 3-D data allowed the construction of an accurate velocity model and the distinction of five major seismic facies within the Lower Freshwater Molasse (Aquitanian) and the Quaternary sedimentary units. Additionally, the Plateau Molasse (PM) and Subalpine Molasse (SM) erosional surface, "La Paudeze" thrust fault (PM-SM boundary) and the thickness of Quaternary sediments were accurately delineated in 3-D.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Imaging mass spectrometry (IMS) is useful for visualizing the localization of phospholipids on biological tissue surfaces creating great opportunities for IMS in lipidomic investigations. With advancements in IMS of lipids, there is a demand for large-scale tissue studies necessitating stable, efficient and well-defined sample handling procedures. Our work within this article shows the effects of different storage conditions on the phospholipid composition of sectioned tissues from mouse organs. We have taken serial sections from mouse brain, kidney and liver thaw mounted unto ITO-coated glass slides and stored them under various conditions later analyzing them at fixed time points. A global decrease in phospholipid signal intensity is shown to occur and to be a function of time and temperature. Contrary to the global decrease, oxidized phospholipid and lysophospholipid species are found to increase within 2 h and 24 h, respectively, when mounted sections are kept at ambient room conditions. Imaging experiments reveal that degradation products increase globally across the tissue. Degradation is shown to be inhibited by cold temperatures, with sample integrity maintained up to a week after storage in −80 °C freezer under N2 atmosphere. Overall, the results demonstrate a timeline of the effects of lipid degradation specific to sectioned tissues and provide several lipid species which can serve as markers of degradation. Importantly, the timeline demonstrates oxidative sample degradation begins appearing within the normal timescale of IMS sample preparation of lipids (i.e. 1-2 h) and that long-term degradation is global. Taken together, these results strengthen the notion that standardized procedures are required for phospholipid IMS of large sample sets, or in studies where many serial sections are prepared together but analyzed over time such as in 3-D IMS reconstruction experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Black-blood fast spin-echo imaging is a powerful technique for the evaluation of cardiac anatomy. To avoid fold-over artifacts, using a sufficiently large field of view in phase-encoding direction is mandatory. The related oversampling affects scanning time and respiratory chest motion artifacts are commonly observed. The excitation of a volume that exclusively includes the heart without its surrounding structures may help to improve scan efficiency and minimize motion artifacts. Therefore, and by building on previously reported inner-volume approach, the combination of a black-blood fast spin-echo sequence with a two-dimensionally selective radiofrequency pulse is proposed for selective "local excitation" small field of view imaging of the heart. This local excitation technique has been developed, implemented, and tested in phantoms and in vivo. With this method, small field of view imaging of a user-specified region in the human thorax is feasible, scanning becomes more time efficient, motion artifacts can be minimized, and additional flexibility in the choice of imaging parameters can be exploited.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We studied the frequency of specific anti-Toxoplasma IgM, IgA and IgE antibodies in serum of 28 immunocompetent Colombian patients, selected by ophthalmologists and with lesions that were compatible with ocular toxoplasmosis. Patients were classified in three groups: (i) group 1 consisted of ten patients with a first episode; (ii) group 2, with seven patients with a recurrence and (iii) group 3, consisted of eleven patients with chronic chorioretinal lesion without uveitis. We found that 10/28 (35%) of Colombian patients with ocular toxoplasmosis possessed at least one serological marker for Toxoplasma infection different from IgG. In group 1 (first episode), we found simultaneous presence of specific IgM plus IgA plus IgE in 1/10 (10%). In group 2 (recurrences) in 1/7 (14%) we found IgM and IgA test positives and in 1/7 (14%) we found IgM and IgE tests positives. In group 3 (toxoplasmic chorioretinal scar) the IgA serological test was positive in 2/11 (18%). These results show that serum IgM or IgA or IgE can be present during recurrences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Five patients with a chief visual complaint of photophobia were subsequently found to have compressive lesions of the optic chiasm. Visual acuity and visual field deficits were often subtle. Magnetic resonance imaging scanning revealed large suprasellar masses, including three pituitary adenomas, a craniopharyngioma, and a clivus chordoma. Photophobia resolved in all patients following treatment of the tumors. A compressive lesion of the optic chiasm should be considered in patients who experience persistent photophobia unexplained by ocular abnormalities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The feasibility of three-dimensional (3D) whole-heart imaging of the coronary venous (CV) system was investigated. The hypothesis that coronary magnetic resonance venography (CMRV) can be improved by using an intravascular contrast agent (CA) was tested. A simplified model of the contrast in T(2)-prepared steady-state free precession (SSFP) imaging was applied to calculate optimal T(2)-preparation durations for the various deoxygenation levels expected in venous blood. Non-contrast-agent (nCA)- and CA-enhanced images were compared for the delineation of the coronary sinus (CS) and its main tributaries. A quantitative analysis of the resulting contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) in both approaches was performed. Precontrast visualization of the CV system was limited by the poor CNR between large portions of the venous blood and the surrounding tissue. Postcontrast, a significant increase in CNR between the venous blood and the myocardium (Myo) resulted in a clear delineation of the target vessels. The CNR improvement was 347% (P < 0.05) for the CS, 260% (P < 0.01) for the mid cardiac vein (MCV), and 430% (P < 0.05) for the great cardiac vein (GCV). The improvement in SNR was on average 155%, but was not statistically significant for the CS and the MCV. The signal of the Myo could be significantly reduced to about 25% (P < 0.001).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Part A:The formulation of local policy and choices

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Part B:Common elements

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Part C:Steam sterilization