694 resultados para nanoporous templates


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Limited experience with bioprosthetic venous valve percutaneously inserted into femoral veins in 15 patients has been promising in short-term results only to show disappointing long-term results. Percutaneous autogenous venous valve (PAVV) transplantation was explored in an ovine model as a possible alternative treatment. METHODS: PAVV consisted of a vein segment containing a valve that was attached to a stent template. The stent templates (n = 9) were designed and hand made in our research laboratory. They consist of two stainless steel square stents 13 or 15 mm in diameter to fit the ovine jugular veins (JV), which ranges from 10 to 15 mm in diameter. A valve-containing segment of JV was harvested and attached with sutures and barbs inside the stent template (n = 9). The valve devices were then manually folded and front loaded inside the 4 cm chamber of the 13F delivery sheath and delivered into the contralateral JV by femoral vein approach. Transplanted PAVVs were studied by immediate and 3 months venograms. Animals were euthanized at 3 months, and jugular veins harvested to perform angioscopic evaluations in vitro. RESULTS: PAVV transplantation was successful in all nine animals. Good valve function with no reflux was observed on immediate and 3 months venograms in eight valves. The transplanted maximal JV diameter ranged from 10.2 mm to 15.4 mm (mean 13.1 +/- 1.5 mm). Venoscopic examination revealed intact, flexible, nonthickened valve leaflets in eight specimens. One PAVV exhibited normal function of one leaflet only; the other cusp was accidentally cut during the transplantation procedure. All transplanted autologous valves were free of thrombus and incorporated into the vein wall of the host vessel. CONCLUSION: This study demonstrated that autogenous valve transplants remained patent and competent without long-term anticoagulation for up to 3 months. The percutaneous autogenous venous valve may provide in future minimally invasive treatment for patients with chronic deep venous insufficiency, but long-term studies need to be done to document its continued patency and function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to improve the osseointegration of endosseous implants made from titanium, the structure and composition of the surface were modified. Mirror-polished commercially pure (cp) titanium substrates were coated by the sol-gel process with different oxides: TiO(2), SiO(2), Nb(2)O(5) and SiO(2)-TiO(2). The coatings were physically and biologically characterized. Infrared spectroscopy confirmed the absence of organic residues. Ellipsometry determined the thickness of layers to be approximately 100nm. High resolution scanning electron microscopy (SEM) and atomice force microscopy revealed a nanoporous structure in the TiO(2) and Nb(2)O(5) layers, whereas the SiO(2) and SiO(2)-TiO(2) layers appeared almost smooth. The R(a) values, as determined by white-light interferometry, ranged from 20 to 50nm. The surface energy determined by the sessile-drop contact angle method revealed the highest polar component for SiO(2) (30.7mJm(-2)) and the lowest for cp-Ti and 316L stainless steel (6.7mJm(-2)). Cytocompatibility of the oxide layers was investigated with MC3T3-E1 osteoblasts in vitro (proliferation, vitality, morphology and cytochemical/immunolabelling of actin and vinculin). Higher cell proliferation rates were found in SiO(2)-TiO(2) and TiO(2), and lower in Nb(2)O(5) and SiO(2); whereas the vitality rates increased for cp-Ti and Nb(2)O(5). Cytochemical assays showed that all substrates induced a normal cytoskeleton and well-developed focal adhesion contacts. SEM revealed good cell attachment for all coating layers. In conclusion, the sol-gel-derived oxide layers were thin, pure and nanostructured; consequent different osteoblast responses to those coatings are explained by the mutual action and coadjustment of different interrelated surface parameters.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: Bone attrition probably constitutes remodeling of the bone, resulting in flattening or depression of the articular surfaces. Defining bone attrition is challenging because it is an accentuation of the normal curvature of the tibial plateaus. We aimed to define bone attrition on magnetic resonance imaging (MRI) of the knee using information from both radiographs and MRIs, and to assess whether bone attrition is common prior to end stage disease osteoarthritis (OA) in the tibio-femoral joint. METHODS: All knees of participants in the community-based sample of the Framingham OA Study were evaluated for bone attrition in radiographs and MRIs. Radiographs were scored based on templates designed to outline the normal contours of the tibio-femoral joint. MRIs were analyzed using the semi-quantitative Whole-Organ Magnetic Resonance Imaging Scoring (WORMS) method. The prevalence of bone attrition was calculated using two different thresholds for MRI scores. RESULTS: Inter-observer agreement for identification of bone attrition was substantial for the radiographs (kappa=0.71, 95% CI 0.67-0.81) and moderate for MRI (kappa=0.56, 95% CI 0.40-0.72). Of 964 knees, 5.7% of the radiographs showed bone attrition. Of these, 91% of MRIs were also read as showing bone attrition. We selected a conservative threshold for bone attrition on MRI scoring (> or = 2 on a 0-3 scale) based on agreement with attrition on the radiograph or when bone attrition on MRI co-occurred with cartilage loss on OA. Using this threshold for bone attrition on MRI, bone attrition was common in knees with OA. For example, in knees with mild OA but no joint space narrowing, 13 of 88 MRIs (14.8%) showed bone attrition. CONCLUSIONS: Using MRI we found that many knees with mild OA without joint narrowing on radiographs had bone attrition, even using conservative definitions. The validity of our definition of bone attrition should be evaluated in further studies. Bone attrition may occur in milder OA and at earlier stages of disease than previously thought.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents an innovative integration of sensing and nano-scaled fluidic actuation in the combination of pH sensitive optical dye immobilization with the electro-osmotic phenomena in polar solvents like water for flow-through pH measurements. These flow-through measurements are performed in a flow-through sensing device (FTSD) configuration that is designed and fabricated at MTU. A relatively novel and interesting material, through-wafer mesoporous silica substrates with pore diameters of 20 -200 nm and pore depths of 500 µm are fabricated and implemented for electro-osmotic pumping and flow-through fluorescence sensing for the first time. Performance characteristics of macroporous silicon (> 500 µm) implemented for electro-osmotic pumping include, a very large flow effciency of 19.8 µLmin-1V-1 cm-2 and maximum pressure effciency of 86.6 Pa/V in comparison to mesoporous silica membranes with 2.8 µLmin-1V-1cm-2 flow effciency and a 92 Pa/V pressure effciency. The electrical current (I) of the EOP system for 60 V applied voltage utilizing macroporous silicon membranes is 1.02 x 10-6A with a power consumption of 61.74 x 10-6 watts. Optical measurements on mesoporous silica are performed spectroscopically from 300 nm to 1000 nm using ellipsometry, which includes, angularly resolved transmission and angularly resolved reflection measurements that extend into the infrared regime. Refractive index (n) values for oxidized and un-oxidized mesoporous silicon sample at 1000 nm are found to be 1.36 and 1.66. Fluorescence results and characterization confirm the successful pH measurement from ratiometric techniques. The sensitivity measured for fluorescein in buffer solution is 0.51 a.u./pH compared to sensitivity of ~ 0.2 a.u./pH in the case of fluorescein in porous silica template. Porous silica membranes are efficient templates for immobilization of optical dyes and represent a promising method to increase sensitivity for small variations in chemical properties. The FTSD represents a device topology suitable for application to long term monitoring of lakes and reservoirs. Unique and important contributions from this work include fabrication of a through-wafer mesoporous silica membrane that has been thoroughly characterized optically using ellipsometry. Mesoporous silica membranes are tested as a porous media in an electro-osmotic pump for generating high pressure capacities due to the nanometer pore sizes of the porous media. Further, dye immobilized mesoporous silica membranes along with macroporous silicon substrates are implemented for continuous pH measurements using fluorescence changes in a flow-through sensing device configuration. This novel integration and demonstration is completely based on silicon and implemented for the first time and can lead to miniaturized flow-through sensing systems based on MEMS technologies.