954 resultados para low level radio frequency


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Vibration-based damage identification (VBDI) techniques have been developed in part to address the problems associated with an aging civil infrastructure. To assess the potential of VBDI as it applies to highway bridges in Iowa, three applications of VBDI techniques were considered in this study: numerical simulation, laboratory structures, and field structures. VBDI techniques were found to be highly capable of locating and quantifying damage in numerical simulations. These same techniques were found to be accurate in locating various types of damage in a laboratory setting with actual structures. Although there is the potential for these techniques to quantify damage in a laboratory setting, the ability of the methods to quantify low-level damage in the laboratory is not robust. When applying these techniques to an actual bridge, it was found that some traditional applications of VBDI methods are capable of describing the global behavior of the structure but are most likely not suited for the identification of typical damage scenarios found in civil infrastructure. Measurement noise, boundary conditions, complications due to substructures and multiple material types, and transducer sensitivity make it very difficult for present VBDI techniques to identify, much less quantify, highly localized damage (such as small cracks and minor changes in thickness). However, while investigating VBDI techniques in the field, it was found that if the frequency-domain response of the structure can be generated from operating traffic load, the structural response can be animated and used to develop a holistic view of the bridge’s response to various automobile loadings. By animating the response of a field bridge, concrete cracking (in the abutment and deck) was correlated with structural motion and problem frequencies (i.e., those that cause significant torsion or tension-compression at beam ends) were identified. Furthermore, a frequency-domain study of operational traffic was used to identify both common and extreme frequencies for a given structure and loading. Common traffic frequencies can be compared to problem frequencies so that cost-effective, preventative solutions (either structural or usage-based) can be developed for a wide range of IDOT bridges. Further work should (1) perfect the process of collecting high-quality operational frequency response data; (2) expand and simplify the process of correlating frequency response animations with damage; and (3) develop efficient, economical, preemptive solutions to common damage types.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a study on the development and the evaluation of a fully automated radio-frequency glow discharge system devoted to the deposition of amorphous thin film semiconductors and insulators. The following aspects were carefully addressed in the design of the reactor: (1) cross contamination by dopants and unstable gases, (2) capability of a fully automated operation, (3) precise control of the discharge parameters, particularly the substrate temperature, and (4) high chemical purity. The new reactor, named ARCAM, is a multiplasma-monochamber system consisting of three separated plasma chambers located inside the same isothermal vacuum vessel. Thus, the system benefits from the advantages of multichamber systems but keeps the simplicity and low cost of monochamber systems. The evaluation of the reactor performances showed that the oven-like structure combined with a differential dynamic pumping provides a high chemical purity in the deposition chamber. Moreover, the studies of the effects associated with the plasma recycling of material from the walls and of the thermal decomposition of diborane showed that the multiplasma-monochamber design is efficient for the production of abrupt interfaces in hydrogenated amorphous silicon (a-Si:H) based devices. Also, special attention was paid to the optimization of plasma conditions for the deposition of low density of states a-Si:H. Hence, we also present the results concerning the effects of the geometry, the substrate temperature, the radio frequency power and the silane pressure on the properties of the a-Si:H films. In particular, we found that a low density of states a-Si:H can be deposited at a wide range of substrate temperatures (100°C

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Parkinsonian tremor is among the most emblematic medical signs and is one of the cardinal manifestations of Parkinson's disease (PD). Its semiology has been extensively addressed by ancient and contemporary medical literature, but more attention has been dedicated to its medical treatment in the past than nowadays. Among the hundreds of studies performed to determine the value of medical and surgical approaches on motor and non motor signs of PD, only a minority specifically considered effect on tremor as an efficacy outcome. Current available guidelines for PD treatment include attempts to specifically address tremor treatment but stress the low level of evidences available. In these conditions, with its still poorly understood pathophysiological basis and variable clinical expression PD tremor treatment is a clinical challenge. Only surgery (lesion or high frequency stimulation) of discrete deep brain targets consistently provides symptomatic long lasting alleviation. Through revision of contemporary scientific evidence, the purpose of this paper is to offer a systematic pragmatic approach to symptomatic management of tremor as one of the distinctive signs of PD that may generate substantial disability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Refractory status epilepticus (RSE)-that is, seizures resistant to at least two antiepileptic drugs (AEDs)-is generally managed with barbiturates, propofol, or midazolam, despite a low level of evidence (Rossetti, 2007). When this approach fails, the need for alternative pharmacologic and nonpharmacologic strategies emerges. These have been investigated even less systematically than the aforementioned compounds, and are often used, sometimes in succession, in cases of extreme refractoriness (Robakis & Hirsch, 2006). Several possibilities are reviewed here. In view of the marked heterogeneity of reported information, etiologies, ages, and comedications, it is extremely difficult to evaluate a given method, not to say to compare different strategies among them. Pharmacologic Approaches Isoflurane and desflurane may complete the armamentarium of anesthetics,' and should be employed in a ''close'' environment, in order to prevent intoxication of treating personnel. c-Aminobutyric acid (GABA)A receptor potentiation represents the putative mechanism of action. In an earlier report, isoflurane was used for up to 55 h in nine patients, controlling seizures in all; mortality was, however, 67% (Kofke et al., 1989). More recently, the use of these inhalational anesthetics was described in seven subjects with RSE, for up to 26 days, with an endtidal concentration of 1.2-5%. All patients required vasopressors, and paralytic ileus occurred in three; outcome was fatal in three patients (43%) (Mirsattari et al., 2004). Ketamine, known as an emergency anesthetic because of its favorable hemodynamic profile, is an N-methyl-daspartate (NMDA) antagonist; the interest for its use in RSE derives from animal works showing loss of GABAA efficacy and maintained NMDA sensitivity in prolonged status epilepticus (Mazarati & Wasterlain, 1999). However, to avoid possible neurotoxicity, it appears safer to combine ketamine with GABAergic compounds (Jevtovic-Todorovic et al., 2001; Ubogu et al., 2003), also because of a likely synergistic effect (Martin & Kapur, 2008). There are few reported cases in humans, describing progressive dosages up to 7.5 mg/kg/h for several days (Sheth & Gidal, 1998; Quigg et al., 2002; Pruss & Holtkamp, 2008), with moderate outcomes. Paraldehyde acts through a yet-unidentified mechanism, and appears to be relatively safe in terms of cardiovascular tolerability (Ramsay, 1989; Thulasimani & Ramaswamy, 2002), but because of the risk of crystal formation and its reactivity with plastic, it should be used only as fresh prepared solution in glass devices (Beyenburg et al., 2000). There are virtually no recent reports regarding its use in adults RSE, whereas rectal paraldehyde in children with status epilepticus resistant to benzodiazepines seems less efficacious than intravenous phenytoin (Chin et al., 2008). Etomidate is another anesthetic agent for which the exact mechanism of action is also unknown, which is also relatively favorable regarding cardiovascular side effects, and may be used for rapid sedation. Its use in RSE was reported in eight subjects (Yeoman et al., 1989). After a bolus of 0.3 mg/kg, a drip of up to 7.2 mg/kg/h for up to 12 days was administered, with hypotension occurring in five patients; two patients died. A reversible inhibition of cortisol synthesis represents an important concern, limiting its widespread use and implying a careful hormonal substitution during treatment (Beyenburg et al., 2000). Several nonsedating approaches have been reported. The use of lidocaine in RSE, a class Ib antiarrhythmic agent modulating sodium channels, was reviewed in 1997 (Walker & Slovis, 1997). Initial boluses up to 5 mg/kg and perfusions of up to 6 mg/kg/h have been mentioned; somewhat surprisingly, at times lidocaine seemed to be successful in controlling seizures in patients who were refractory to phenytoin. The aforementioned dosages should not be overshot, in order to keep lidocaine levels under 5 mg/L and avoid seizure induction (Hamano et al., 2006). A recent pediatric retrospective survey on 57 RSE episodes (37 patients) described a response in 36%, and no major adverse events; mortality was not given (Hamano et al., 2006 Verapamil, a calcium-channel blocker, also inhibits P-glycoprotein, a multidrug transporter that may diminish AED availability in the brain (Potschka et al., 2002). Few case reports on its use in humans are available; this medication nevertheless appears relatively safe (under cardiac monitoring) up to dosages of 360 mg/day (Iannetti et al., 2005). Magnesium, a widely used agent for seizures elicited by eclampsia, has also been anecdotally reported in RSE (Fisher et al., 1988; Robakis & Hirsch, 2006), but with scarce results even at serum levels of 14 mm. The rationale may be found in the physiologic blockage of NMDA channels by magnesium ions (Hope & Blumenfeld, 2005). Ketogenic diet has been prescribed for decades, mostly in children, to control refractory seizures. Its use in RSE as ''ultima ratio'' has been occasionally described: three of six children (Francois et al., 2003) and one adult (Bodenant et al., 2008) were responders. This approach displays its effect subacutely over several days to a few weeks. Because ''malignant RSE'' seems at times to be the consequence of immunologic processes (Holtkamp et al., 2005), a course of immunomodulatory treatment is often advocated in this setting, even in the absence of definite autoimmune etiologies (Robakis & Hirsch, 2006); steroids, adrenocorticotropic hormone (ACTH), plasma exchanges, or intravenous immunoglobulins may be used alone or in sequential combination. Nonpharmacologic Approaches These strategies are described somewhat less frequently than pharmacologic approaches. Acute implantation of vagus nerve stimulation (VNS) has been reported in RSE (Winston et al., 2001; Patwardhan et al., 2005; De Herdt et al., 2009). Stimulation was usually initiated in the operation room, and intensity progressively adapted over a few days up to 1.25 mA (with various regimens regarding the other parameters), allowing a subacute seizure control; one transitory episode of bradycardia/asystole has been described (De Herdt et al., 2009). Of course, pending identification of a definite seizure focus, resective surgery may also be considered in selected cases (Lhatoo & Alexopoulos, 2007). Low-frequency (0.5 Hz) transcranial magnetic stimulation (TMS) at 90% of the resting motor threshold has been reported to be successful for about 2 months in a patient with epilepsia partialis continua, but with a weaning effect afterward, implying the need for a repetitive use (Misawa et al., 2005). More recently, TMS was applied in a combination of a short ''priming'' high frequency (up to 100 Hz) and longer runs of low-frequency stimulations (1 Hz) at 90-100% of the motor threshold in seven other patients with simple-partial status, with mixed results (Rotenberg et al., 2009). Paradoxically at first glance, electroconvulsive treatment may be found in cases of extremely resistant RSE. A recent case report illustrates its use in an adult patient with convulsive status, with three sessions (three convulsions each) carried out over 3 days, resulting in a moderate recovery; the mechanism is believed to be related to modification of the synaptic release of neurotransmitters (Cline & Roos, 2007). Therapeutic hypothermia, which is increasingly used in postanoxic patients (Oddo et al., 2008), has been the object of a recent case series in RSE (Corry et al., 2008). Reduction of energy demand, excitatory neurotransmission, and neuroprotective effects may account for the putative mechanism of action. Four adult patients in RSE were cooled to 31_-34_C with an endovascular system for up to 90 h, and then passively rewarmed over 2-50 h. Seizures were controlled in two patients, one of whom died; also one of the other two patients in whom seizures continued subsequently deceased. Possible side effects are related to acid-base and electrolyte disturbances, and coagulation dysfunction including thrombosis, infectious risks, cardiac arrhythmia, and paralytic ileus (Corry et al., 2008; Cereda et al., 2009). Finally, anecdotic evidence suggests that cerebrospinal fluid (CSF)-air exchange may induce some transitory benefit in RSE (Kohrmann et al., 2006); although this approach was already in use in the middle of the twentieth century, the mechanism is unknown. Acknowledgment A wide spectrum of pharmacologic (sedating and nonsedating) and nonpharmacologic (surgical, or involving electrical stimulation) regimens might be applied to attempt RSE control. Their use should be considered only after refractoriness to AED or anesthetics displaying a higher level of evidence. Although it seems unlikely that these uncommon and scarcely studied strategies will influence the RSE outcome in a decisive way, some may be interesting in particular settings. However, because the main prognostic determinant in status epilepticus appears to be related to the underlying etiology rather than to the treatment approach (Rossetti et al., 2005, 2008), the safety issue should always represent a paramount concern for the prescribing physician. Conclusion The author confirms that he has read the Journal's position on issues involved in ethical publication and affirms that this paper is consistent with those guidelines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This report describes the results of the research project investigating the use of advanced field data acquisition technologies for lowa transponation agencies. The objectives of the research project were to (1) research and evaluate current data acquisition technologies for field data collection, manipulation, and reporting; (2) identify the current field data collection approach and the interest level in applying current technologies within Iowa transportation agencies; and (3) summarize findings, prioritize technology needs, and provide recommendations regarding suitable applications for future development. A steering committee consisting oretate, city, and county transportation officials provided guidance during this project. Technologies considered in this study included (1) data storage (bar coding, radio frequency identification, touch buttons, magnetic stripes, and video logging); (2) data recognition (voice recognition and optical character recognition); (3) field referencing systems (global positioning systems [GPS] and geographic information systems [GIs]); (4) data transmission (radio frequency data communications and electronic data interchange); and (5) portable computers (pen-based computers). The literature review revealed that many of these technologies could have useful applications in the transponation industry. A survey was developed to explain current data collection methods and identify the interest in using advanced field data collection technologies. Surveys were sent out to county and city engineers and state representatives responsible for certain programs (e.g., maintenance management and construction management). Results showed that almost all field data are collected using manual approaches and are hand-carried to the office where they are either entered into a computer or manually stored. A lack of standardization was apparent for the type of software applications used by each agency--even the types of forms used to manually collect data differed by agency. Furthermore, interest in using advanced field data collection technologies depended upon the technology, program (e.g.. pavement or sign management), and agency type (e.g., state, city, or county). The state and larger cities and counties seemed to be interested in using several of the technologies, whereas smaller agencies appeared to have very little interest in using advanced techniques to capture data. A more thorough analysis of the survey results is provided in the report. Recommendations are made to enhance the use of advanced field data acquisition technologies in Iowa transportation agencies: (1) Appoint a statewide task group to coordinate the effort to automate field data collection and reporting within the Iowa transportation agencies. Subgroups representing the cities, counties, and state should be formed with oversight provided by the statewide task group. (2) Educate employees so that they become familiar with the various field data acquisition technologies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: (S)-Methadone, metabolized mainly by CYP2B6, shows a wide interindividual variability in its pharmacokinetics and pharmacodynamics. METHODS: Resequencing of the CYP2B6 gene was performed in 12 and 35 selected individuals with high (S)-methadone plasma exposure and low (S)-methadone plasma exposure, respectively, from a previously described cohort of 276 patients undergoing methadone maintenance treatment. Selected genetic polymorphisms were then analyzed in the complete cohort. RESULTS: The rs35303484 (*11; c136A>G; M46V) polymorphism was overrepresented in the high (S)-methadone level group, whereas the rs3745274 (*9; c516G>T; Q172H), rs2279344 (c822+183G>A), and rs8192719 (c1294+53C>T) polymorphisms were underrepresented in the low (S)-methadone level group, suggesting an association with decreased CYP2B6 activity. Conversely, the rs3211371 (*5; c1459C>T; R487C) polymorphism was overrepresented in the low-level group, indicating an increased CYP2B6 activity. A higher allele frequency was found in the high-level group compared with the low-level group for rs3745274 (*9; c516G>T; Q172H), rs2279343 (*4; c785A>G; K262R) (together representing CYP2B6*6), rs8192719 (c1294+53C>T), and rs2279344 (c822+183G>A), suggesting their involvement in decreased CYP2B6 activity. These results should be replicated in larger independent cohorts. CONCLUSION: Known genetic polymorphisms in CYP2B6 contribute toward explaining extreme (S)-methadone plasma levels observed in a cohort of patients following methadone maintenance treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Long-term treatment of primary HIV-1 infection (PHI) may allow the immune reconstitution of responses lost during the acute viremic phase and decrease of peripheral reservoirs. This in turn may represent the best setting for the use of therapeutic vaccines in order to lower the viral set-point or control of viral rebound upon ART discontinuation. Methods We investigated a cohort of 16 patients who started ART at PHI, with treatment duration of ≥4 years and persistent aviremia (<50 HIV-1 copies/ml). The cohort was characterized in terms of viral subtype, cell-associated RNA, proviral DNA and HLA genotype. Secretion of IFN-γ, IL-2 and TNF-α by CD8 T-cells was analysed by polychromatic flowcytometry using a panel of 192 HIV-1-derived epitopes. Results This cohort is highly homogenous in terms of viral subtype: 81% clade B. We identified 44 epitope-specific responses: all patients had detectable responses to >1 epitope and the mean number of responding epitopes per patient was 3. The mean frequency of cytokines-secreting CD8 T-cells was 0.32%. CD8 T-cells secreting simultaneously IFN-γ, IL-2 and TNF-α made up for about 40% of the response and cells secreting at least 2 cytokines for about 80%, consistent with a highly polyfunctional CD8 T-cell profile. There was no difference in term of polyfunctionality when HLA restriction, or recognized viral regions and epitopes were considered. Proviral DNA was detectable in all patients but at low levels (mean = 108 copies/1 million PBMCs) while cell-associated mRNA was not detectable in 19% of patients (mean = 11 copies/1 million PBMCs when detectable). Conclusion Patients with sustained virological suppression after initiation of ART at PHI show polyfunctional CD8 T-cell and low levels of proviral DNA with an absence of residual replication in a substantial percentage of patients. The use of therapeutic vaccines in this population may promote low level of rebound viremia or control of viral replication upon ART cessation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Multisensory interactions have been documented within low-level, even primary, cortices and at early post-stimulus latencies. These effects are in turn linked to behavioral and perceptual modulations. In humans, visual cortex excitability, as measured by transcranial magnetic stimulation (TMS) induced phosphenes, can be reliably enhanced by the co-presentation of sounds. This enhancement occurs at pre-perceptual stages and is selective for different types of complex sounds. However, the source(s) of auditory inputs effectuating these excitability changes in primary visual cortex remain disputed. The present study sought to determine if direct connections between low-level auditory cortices and primary visual cortex are mediating these kinds of effects by varying the pitch and bandwidth of the sounds co-presented with single-pulse TMS over the occipital pole. Our results from 10 healthy young adults indicate that both the central frequency and bandwidth of a sound independently affect the excitability of visual cortex during processing stages as early as 30 msec post-sound onset. Such findings are consistent with direct connections mediating early-latency, low-level multisensory interactions within visual cortices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Micro-electromechanical systems (MEMS) provide vast improvements over existing sensing methods in the context of structural health monitoring (SHM) of highway infrastructure systems, including improved system reliability, improved longevity and enhanced system performance, improved safety against natural hazards and vibrations, and a reduction in life cycle cost in both operating and maintaining the infrastructure. Advancements in MEMS technology and wireless sensor networks provide opportunities for long-term continuous, real-time structural health monitoring of pavements and bridges at low cost within the context of sustainable infrastructure systems. The primary objective of this research was to investigate the use of MEMS in highway structures for health monitoring purposes. This study focused on investigating the use of MEMS and their potential applications in concrete through a comprehensive literature review, a vendor survey, and a laboratory study, as well as a small-scale field study. Based on the comprehensive literature review and vendor survey, the latest information available on off-the-shelf MEMS devices, as well as research prototypes, for bridge, pavement, and traffic applications were synthesized. A commercially-available wireless concrete monitoring system based on radio-frequency identification (RFID) technology and off-the-shelf temperature and humidity sensors were tested under controlled laboratory and field conditions. The test results validated the ability of the RFID wireless concrete monitoring system in accurately measuring the temperature both inside the laboratory and in the field under severe weather conditions. In consultation with the project technical advisory committee (TAC), the most relevant MEMS-based transportation infrastructure research applications to explore in the future were also highlighted and summarized.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Steel reinforcing bar (rebar) corrosion due to chlorine ingress is the primary degradation mechanism for bridge decks. In areas where rock salt is used as a de-icing agent, salt water seeps into the concrete through cracks, causing corrosion of the rebar and potentially leading to catastrophic failure if not repaired. This project explores the use of radio frequency identification (RFID) tags as low-cost corrosion sensors. RFID tags, when embedded in concrete, will fail due to corrosion in the same manner as rebar after prolonged exposure to salt water. In addition, the presence of salt water interferes with the ability to detect the tags, providing a secondary mechanism by which this method can work. During this project, a fieldable RFID equipment setup was constructed and tested. In addition to a number of laboratory experiments to validate the underlying principles, RFID tags were embedded and tested in several actual bridge decks. Two major challenges were addressed in this project: issues associated with tags not functioning due to being in close proximity to rebar and issues associated with portland concrete coming in direct contact with the tags causing a detuning effect and preventing the tags from operating properly. Both issues were investigated thoroughly. The first issue was determined to be a problem only if the tags are placed in close proximity to rebar. The second issue was resolved by encapsulating the tag. Two materials, polyurethane spray foam and extruded polystyrene, were identified as providing good performance after testing, both in the lab and in the field.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Experimental and theoretical investigations for growth of silicon nanoparticles (4 to 14 nm) in radio frequency discharge were carried out. Growth processes were performed with gas mixtures of SiH4 and Ar in a plasma chemical reactor at low pressure. A distinctive feature of presented kinetic model of generation and growth of nanoparticles (compared to our earlier model) is its ability to investigate small"critical" dimensions of clusters, determining the rate of particle production and taking into account the influence of SiH2 and Si2Hm dimer radicals. The experiments in the present study were extended to high pressure (≥20 Pa) and discharge power (≥40 W). Model calculations were compared to experimental measurements, investigating the dimension of silicon nanoparticles as a function of time, discharge power, gas mixture, total pressure, and gas flow.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Declining physical activity is associated with a rising burden of global disease. There is little evidence about effective ways to increase adherence to physical activity. Therefore, interventions are needed that produce sustained increases in adherence to physical activity and are cost-effective. The purpose is to assess the effectiveness of a primary care physical activity intervention in increasing adherence to physical activity in the general population seen in primary care. Method and design: Randomized controlled trial with systematic random sampling. A total of 424 subjects of both sexes will participate; all will be over the age of 18 with a low level of physical activity (according to the International Physical Activity Questionnaire, IPAQ), self-employed and from 9 Primary Healthcare Centres (PHC). They will volunteer to participate in a physical activity programme during 3 months (24 sessions; 2 sessions a week, 60 minutes per session). Participants from each PHC will be randomly allocated to an intervention (IG) and control group (CG). The following parameters will be assessed pre and post intervention in both groups: (1) health-related quality of life (SF-12), (2) physical activity stage of change (Prochaska's stages of change), (3) level of physical activity (IPAQ-short version), (4) change in perception of health (vignettes from the Cooperative World Organization of National Colleges, Academies, and Academic Associations of Family Physicians, COOP/WONCA), (5) level of social support for the physical activity practice (Social Support for Physical Activity Scale, SSPAS), and (6) control based on analysis (HDL, LDL and glycated haemoglobin).Participants' frequency of visits to the PHC will be registered over the six months before and after the programme. There will be a follow up in a face to face interview three, six and twelve months after the programme, with the reduced version of IPAQ, SF-12, SSPAS, and Prochaska's stages. Discussion: The pilot study showed the effectiveness of an enhanced low-cost, evidence-based intervention in increased physical activity and improved social support. If successful in demonstrating long-term improvements, this randomised controlled trial will be the first sustainable physical activity intervention based in primary care in our country to demonstrate longterm adherence to physical activity. Trial Registration: A service of the U.S. National Institutes of Health. Developed by the National Library of Medicine. ClinicalTrials.gov ID: NCT00714831.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Spectrum scarcity demands thinking new ways tomanage the distribution of radio frequency bands so that its use is more effective. The emerging technology that can enable this paradigm shift is the cognitive radio. Different models fororganizing and managing cognitive radios have emerged, all with specific strategic purposes. In this article we review the allocation spectrum patterns of cognitive radio networks andanalyse which are the common basis of each model.We expose the vulnerabilities and open challenges that still threaten the adoptionand exploitation of cognitive radios for open civil networks.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This research has been focused at the development of a tuned systematic design methodology, which gives the best performance in a computer aided environment and utilises a cross-technological approach, specially tested with and for laser processed microwave mechanics. A tuned design process scheme is also presented. Because of the currently large production volumes of microwave and radio frequency mechanics even slight improvements of design methodologies or manufacturing technologies would give reasonable possibilities for cost reduction. The typical number of required iteration cycles could be reduced to one fifth of normal. The research area dealing with the methodologies is divided firstly into a function-oriented, a performance-oriented or a manufacturability-oriented product design. Alternatively various approaches can be developed for a customer-oriented, a quality-oriented, a cost-oriented or an organisation-oriented design. However, the real need for improvements is between these two extremes. This means that the effective methodology for the designers should not be too limited (like in the performance-oriented design) or too general (like in the organisation-oriented design), but it should, include the context of the design environment. This is the area where the current research is focused. To test the developed tuned design methodology for laser processing (TDMLP) and the tuned optimising algorithm for laser processing (TOLP), seven different industrial product applications for microwave mechanics have been designed, CAD-modelled and manufactured by using laser in small production series. To verify that the performance of these products meets the required level and to ensure the objectiveness ofthe results extensive laboratory tests were used for all designed prototypes. As an example a Ku-band horn antenna can be laser processed from steel in 2 minutes at the same time obtaining a comparable electrical performance of classical aluminium units or the residual resistance of a laser joint in steel could be limited to 72 milliohmia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A portable microcontrolled system is proposed to monitor conductivity, temperature and pH in on-line, in situ and remote way from a water reservoir faraway 200 m. The system comprises two modules: one for data reception (located in laboratory) and another for data acquisition/transmission (located near water reservoir). It uses a microcontroller and a transceiver to remote data transmission/reception by radio frequency. Variations of water parameters were simultaneously monitored without interruption during a period of ten hours with a relative error about 4.0 %. The developed system showed simple, stable, accurate, robust and low-cost to determine parameters of water in field.