991 resultados para interleukin 17 antibody
Resumo:
This work proposes a novel approach for a suitable orientation of antibodies (Ab) on an immunosensing platform, applied here to the determination of 8-hydroxy-2′-deoxyguanosine (8OHdG), a biomarker of oxidative stress that has been associated to chronic diseases, such as cancer. The anti-8OHdG was bound to an amine modified gold support through its Fc region after activation of its carboxylic functions. Non-oriented approaches of Ab binding to the platform were tested in parallel, in order to show that the presented methodology favored Ab/Ag affinity and immunodetection of the antigen. The immunosensor design was evaluated by quartz-crystal microbalance with dissipation, atomic force microscopy, electrochemical impedance spectroscopy (EIS) and square-wave voltammetry. EIS was also a suitable technique to follow the analytical behavior of the device against 8OHdG. The affinity binding between 8OHdG and the antibody immobilized in the gold modified platform increased the charge transfer resistance across the electrochemical set-up. The observed behavior was linear from 0.02 to 7.0 ng/mL of 8OHdG concentrations. The interference from glucose, urea and creatinine was found negligible. An attempt of application to synthetic samples was also successfully conducted. Overall, the presented approach enabled the production of suitably oriented Abs over a gold platform by means of a much simpler process than other oriented-Ab binding approaches described in the literature, as far as we know, and was successful in terms of analytical features and sample application.
Resumo:
This work uses surface imprinting to design a novel smart plastic antibodymaterial (SPAM) for Haemoglobin (Hb). Charged binding sites are described here for the first time to tailor plastic antibody nanostructures for a large size protein such as Hb. Its application to design small, portable and low cost potentiometric devices is presented. The SPAM material was obtained by linking Hb to silica nanoparticles and allowing its ionic interaction with charged vinyl monomers. A neutral polymeric matrix was created around these and the imprinted protein removed. Additional materials were designed in parallel acting as a control: a neutral imprinted material (NSPAM), obtained by removing the charged monomers from the procedure, and the Non-Imprinted (NI) versions of SPAM and NSPAM by removing the template. SEM analysis confirmed the surface modification of the silica nanoparticles. All materials were mixed with PVC/plasticizer and applied as selective membranes in potentiometric transduction. Electromotive force (emf) variations were detected only for selective membranes having a lipophilic anionic additive in the membrane. The presence of Hb inside these membranes was evident and confirmed by FTIR, optical microscopy and Raman spectroscopy. The best performance was found for SPAM-based selective membranes with an anionic lipophilic additive, at pH 5. The limits of detection were 43.8 mg mL 1 and linear responses were obtained down to 83.8 mg mL 1, with an average cationic slope of +40 mV per decade. Good selectivity was also observed against other coexisting biomolecules. The analytical application was conducted successfully, showing accurate and precise results.
Resumo:
This work proposes a novel approach for a suitable orientation of antibodies (Ab) on an immunosensing platform, applied here to the determination of 8-hydroxy-2’-deoxyguanosine (8OHdG), a biomarker of oxidative stress that has been associated to chronic diseases, such as cancer. The Anti-8OHdG was bound to an amine modified gold support through its Fc region after activation of its carboxylic functions. Non-oriented approaches of Ab binding to the platform were tested in parallel, in order to show that the presented proposal favored Ab/Ag affinity. The immunosensor design was evaluated by Quartz-Crystal microbalance with Dissipation, Atomic Force Microscopy, Electrochemical Impedance Spectroscopy (EIS) and Square-Wave Voltammetry. EIS was also a suitable technique to follow the analytical behavior of the device against 8OHdG. The affinity binding between 8OHdG and the antibody immobilized in the gold modified platform increased the charged transfer resistance across the electrochemical sep-up. The observed behavior was linear from 0.02 to 7.0 ng/mL of 8OHdG concentrations. The interference from Glucose, Urea and Creatinine was found negligible. An attempt of application to synthetic samples was also successfully conducted. Overall, the presented approach enabled the production of suitably oriented Abs over a gold platform by means of a much simpler process than other oriented-Ab binding approaches described in the literature, as far as we know, and was successful in terms of analytical features and sample application.
Resumo:
A backside protein-surface imprinting process is presented herein as a novel way to generate specific synthetic antibody materials. The template is covalently bonded to a carboxylated-PVC supporting film previously cast on gold, let to interact with charged monomers and surrounded next by another thick polymer. This polymer is then covalently attached to a transducing element and the backside of this structure (supporting film plus template) is removed as a regular “tape”. The new sensing layer is exposed after the full template removal, showing a high density of re-binding positions, as evidenced by SEM. To ensure that the templates have been efficiently removed, this re-binding layer was cleaned further with a proteolytic enzyme and solution washout. The final material was named MAPS, as in the back-side reading of SPAM, because it acts as a back-side imprinting of this recent approach. It was able to generate, for the first time, a specific response to a complex biomolecule from a synthetic material. Non-imprinted materials (NIMs) were also produced as blank and were used as a control of the imprinting process. All chemical modifications were followed by electrochemical techniques. This was done on a supporting film and transducing element of both MAPS and NIM. Only the MAPS-based device responded to oxLDL and the sensing layer was insensitive to other serum proteins, such as myoglobin and haemoglobin. Linear behaviour between log(C, μg mL−1) versus charged tranfer resistance (RCT, Ω) was observed by electrochemical impedance spectroscopy (EIS). Calibrations made in Fetal Calf Serum (FCS) were linear from 2.5 to 12.5 μg mL−1 (RCT = 946.12 × log C + 1590.7) with an R-squared of 0.9966. Overall, these were promising results towards the design of materials acting close to the natural antibodies and applied to practical use of clinical interest.
Resumo:
This work introduces two major changes to the conventional protocol for designing plastic antibodies: (i) the imprinted sites were created with charged monomers while the surrounding environment was tailored using neutral material; and (ii) the protein was removed from its imprinted site by means of a protease, aiming at preserving the polymeric network of the plastic antibody. To our knowledge, these approaches were never presented before and the resulting material was named here as smart plastic antibody material (SPAM). As proof of concept, SPAM was tailored on top of disposable gold-screen printed electrodes (Au-SPE), following a bottom-up approach, for targeting myoglobin (Myo) in a point-of-care context. The existence of imprinted sites was checked by comparing a SPAM modified surface to a negative control, consisting of similar material where the template was omitted from the procedure and called non-imprinted materials (NIMs). All stages of the creation of the SPAM and NIM on the Au layer were followed by both electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV). AFM imaging was also performed to characterize the topography of the surface. There are two major reasons supporting the fact that plastic antibodies were effectively designed by the above approach: (i) they were visualized for the first time by AFM, being present only in the SPAM network; and (ii) only the SPAM material was able to rebind to the target protein and produce a linear electrical response against EIS and square wave voltammetry (SWV) assays, with NIMs showing a similar-to-random behavior. The SPAM/Au-SPE devices displayed linear responses to Myo in EIS and SWV assays down to 3.5 μg/mL and 0.58 μg/mL, respectively, with detection limits of 1.5 and 0.28 μg/mL. SPAM materials also showed negligible interference from troponin T (TnT), bovine serum albumin (BSA) and urea under SWV assays, showing promising results for point-of-care applications when applied to spiked biological fluids.
Resumo:
A total of 323 patients with lymphadenopathy were selected in Belém, Brazil, between January 1996 and December 2001, and screened for the presence of human herpesvirus-6 (HHV-6) IgM- and- IgG antibodies by enzyme-linked immunosorbent assay (ELISA). When seroprevalence is analyzed by gender, similar rates are found for female (60.6%) and male (55.7%) individuals. Seventy-seven (23.8%) patients were HHV-6-IgM-and- IgG-positive (IgM+ subgroup), with positivity rates of 29.7% and 17.7% (p = 0.0007) for female- and male individuals, respectively. Sera from a subgroup (n = 120) of these subjects, with high HHV-6 antibody levels (either IgM+ or IgG+ reactivities), were subsequently processed for the presence of HHV-6 DNA by polymerase chain reaction (PCR)/nested PCR. Active infections (IgM+ and/or IgG+ high levels specific antibodies plus detection of viral DNA) were diagnosed in 20/77 (20.0%) and 8/43 (18.6%); subgroup of the 120 individuals suspected of having HHV-6 suggestive recent infection. All (n = 28) cases of active infection were found to be associated with HHV-6 variant-A (HHV-6A), as detectable by PCR/nested PCR, using variant-specific primer that amplify regions of 195 base pairs (bp) (HHV-6A) and 423 bp (HHV-6B). Rates of HHV-6 DNA detection between female and male patients were similar (p > 0.05) in the IgM+ and IgG+ groups: 20.4% versus 35.7% and 25.0% versus 13.0%, respectively. HHV-6 DNA was detected across < 5 through 41-50-year age-groups for patients whose serum samples were IgM+, with rates ranging from 7.7% (female subjects aged < 5 years) to 80.0% (male, 11-20 years). Among patients whose serological status was IgG+, HHV-6 DNA was detected in < 5, 6-10, 21-30 and > 50 age-groups at rates that ranged from 15.4% (male, < 5 years of age) to 100.0% (female aged 11-20 years). Swelling cervical lymph nodes were the most common sign, accounting for 9 (32.0%) cases in each gender group. Among patients (n = 28) with active infection by HHV-6A variant, duration of symptoms lasted 1-5 days in 35.7% of subjects, whereas in 64.3% of them the disease lasted 6-20 days. Our data suggest that it is worth seeking for HHV-6 infection whenever a patient (infant or adult) presents with lymphadenopathy as a prominent symptom in the course of an acute febrile illness.
Resumo:
6th Graduate Student Symposium on Molecular Imprinting
Resumo:
JORNADAS DE ELECTROQUÍMICA E INOVAÇÃO 2013
Resumo:
This work presents the development of a low cost sensor device for the diagnosis of breast cancer in point-of-care, made with new synthetic biomimetic materials inside plasticized poly(vinyl chloride), PVC, membranes, for subsequent potentiometric detection. This concept was applied to target a conventional biomarker in breast cancer: Breast Cancer Antigen (CA15-3). The new biomimetic material was obtained by molecularly-imprinted technology. In this, a plastic antibody was obtained by polymerizing around the biomarker that acted as an obstacle to the growth of the polymeric matrix. The imprinted polymer was specifically synthetized by electropolymerization on an FTO conductive glass, by using cyclic voltammetry, including 40 cycles within -0.2 and 1.0 V. The reaction used for the polymerization included monomer (pyrrol, 5.0×10-3 mol/L) and protein (CA15-3, 100U/mL), all prepared in phosphate buffer saline (PBS), with a pH of 7.2 and 1% of ethylene glycol. The biomarker was removed from the imprinted sites by proteolytic action of proteinase K. The biomimetic material was employed in the construction of potentiometric sensors and tested with regard to its affinity and selectivity for binding CA15-3, by checking the analytical performance of the obtained electrodes. For this purpose, the biomimetic material was dispersed in plasticized PVC membranes, including or not a lipophilic ionic additive, and applied on a solid conductive support of graphite. The analytical behaviour was evaluated in buffer and in synthetic serum, with regard to linear range, limit of detection, repeatability, and reproducibility. This antibody-like material was tested in synthetic serum, and good results were obtained. The best devices were able to detect 5 times less CA15-3 than that required in clinical use. Selectivity assays were also performed, showing that the various serum components did not interfere with this biomarker. Overall, the potentiometric-based methods showed several advantages compared to other methods reported in the literature. The analytical process was simple, providing fast responses for a reduced amount of analyte, with low cost and feasible miniaturization. It also allowed the detection of a wide range of concentrations, diminishing the required efforts in previous sample pre-treating stages.
Resumo:
1st ASPIC International Congress
Resumo:
We have developed a cheaper an simple in house indirect ELISA that uses the live attenuated VZV vaccine as a coating antigen. The alternative ELISA had an agreement of 94% when compared with a commercial VZV ELISA kit. Moreover, our ELISA proved to be more reliable than the kit when assessing true negative samples. By adding a standard serum, we were able to produce results in international units per millilitre. Also, the addition of an extra step with 8M urea allowed the assessment of VZV IgG avidity without excessive costs. The cost per sample to test VZV IgG was 2.7 times cheaper with our ELISA, allowing the testing of many samples without the burden of production of VZV antigen in the laboratory.
Resumo:
A total of 354 serum samples from inhabitants who frequent the Clinical Laboratory in Catalão, Goiás, in the central-western region of Brazil, were collected from June to August, 2002. The samples were evaluated by indirect immunofluorescence antibody tests and an enzyme linked immunosorbent assay in order to detect anti-Taenia solium metacestode IgG antibodies. Reactive and inconclusive samples were tested by Western blotting (WB). Considering WB as a confirmation, the frequency of antibodies in the serum samples of the above population was 11.3% (CI 5.09 - 17.51). The immunodominant bands most frequently recognized in WB were 64-68 kDa (97.5%) and 47-52 kDa (80%). The percentage of seropositivity to cysticercosis was significantly higher for individuals residing in areas without sewage systems (p < 0.0001). In conclusion, the results indicate a probable endemic situation of cysticercosis in this population. These results reinforce the urgent need for control and prevention measures to be taken by the local public health services.
Resumo:
INTRODUCTION: Clopidogrel is frequently associated with thrombotic thrombocytopenic purpura, however this drug is rarely related to severe isolated thrombocytopenia. Pentoxifylline has previously been associated with thrombocytopenia only once. To the best of our knowledge, this is the first report of severe isolated thrombocytopenia after therapy with both clopidogrel and pentoxyfilline. CASE PRESENTATION: We report the case of a 79-year-old Caucasian man who presented to our facility with intermittent claudication. He had obliterative arterial disease and started therapy with clopidogrel and pentoxifylline. His basal platelet count was 194 × 109 cells/L. At three days after the start of treatment, our patient had lower limb petechia and stopped taking clopidogrel and pentoxifylline. His platelet count lowered to 4 × 109 cells/L and our patient was admitted to hospital. Our patient had purpura with no other hemorrhages or splenomegaly. Results of a blood smear were normal, and a bone marrow study showed dysmegakaryopoiesis. Antiplatelet antibody test results were negative, as were all viral serology tests. Imaging study results were normal. Our patient was given immunoglobulin but there was no sustained platelet increase, so corticotherapy was started as the next treatment step. At five months after clopidogrel and pentoxifylline were discontinued, his platelet count continued increasing even after prednisolone was tapered. CONCLUSIONS: Severe isolated thrombocytopenia may appear as a side effect when using clopidogrel and pentoxifylline. These drugs are widely used by general physicians, internists, cardiologists and vascular surgeons. We hope this report will raise awareness of the need to monitor the platelet count in patients taking these drugs.