984 resultados para high-field ferromagnetic resonance


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Pencil, red ink on tracing paper; plan and cross-sections; signed. 105x74 cm. Scale 1"=16' [from photographic copy by Lance Burgharrdt]

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Red, black ink on linen; signed. 107x74 cm. Scale: 1"=16' [from photographic copy by Lance Burgharrdt]

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This study determined the relationship between two measures of field fertility of I I high-use Australian artificial insemination (AI) dairy bulls and thirty standard laboratory assessments of spermatozoal post-thaw viability. The two measures of field fertility used, conception rates (cCR) and non-return rates (cNRR), were both corrected for all major non-bull variables. Sperm viability assessments were conducted on semen collected within the same season as that used to derive the field fertility estimates. These assessments measured sperm concentration, motility, morphology and membrane integrity at thawing, after 2 h incubation and after the swim-up sperm selection procedure. Derivations of these measures and in vitro embryo fertilizing and developmental capacity were also determined. The Genstat Statistical Package [Genstat 5 Release 4.2 Reference Manual, VSN International, Oxford, 20001 was used to conduct an analysis of variance on the viability parameters across semen straws and bulls, and to calculate the strength of correlation between each semen parameter, cNRR and cCR in a correlation matrix. Step forward multiple regression identified the combination of semen parameters that were most highly correlated with cCR and with cNRR. The sperm parameters identified as being most predictive of cCR were the percentage of morphologically normal sperm immediately post-thaw (zeroNorm), the number of morphologically normal sperm after the swim-up procedure (nSuNorm), and the rate of zygote cleavage in vitro (Clv); the predictive equation formed by these parameters accounted for 70% of variance. The predictive equation produced for cNRR contained the variables zeroNorm, the proportion of membrane intact sperm after 2 h incubation at 37 degreesC (twoMem) and Clv and accounted for 76.5% of the variation. ZeroNorm was found to be consistent across straws and semen batches within-bull and the sperm parameter with the strongest individual predictive capacity for both cCR (P = 0.1) and cNRR (P = 0.001). Post-thaw sperm parameters can be used to predict field fertility of Australian dairy sires; the calculated predictive equations are particularly useful for identifying and monitoring bulls of very high and very low potential fertility within a group. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background Women genetically predisposed to breast cancer often develop the disease at a young age when dense breast tissue reduces the sensitivity of X-ray mammography. Our aim was, therefore, to compare contrast enhanced magnetic resonance imaging (CE MRI) with mammography for screening. Methods We did a prospective multicentre cohort study in 649 women aged 35-49 years with a strong family history of breast cancer or a high probability of a BRCA1, BRCA2, or TP53 mutation. We recruited participants from 22 centres in the UK, and offered the women annual screening with CE MRI and mammography for 2-7 years. Findings We diagnosed 35 cancers in the 649 women screened with both mammography and CE MRI (1881 screens): 19 by CE MRI only, six by mammography only, and eight by both, with two interval cases. Sensitivity was significantly higher for CE MRI (77%, 95% CI 60-90) than for mammography (40%, 24-58; p=0.01), and was 94% (81-99) when both methods were used. Specificity was 93% (92-95) for mammography, 81% (80-83) for CE MRI (p

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Shell-crosslinked knedel-like nanoparticles (SCKs; knedel is a Polish term for dumplings) were derivatized with gadolinium Shell chelates and studied as robust magnetic-resonance-imaging-active structures with hydrodynamic diameters of 40 +/- 3 nm. SCKs possessing an amphiphilic core-shell morphology were produced from the aqueous assembly of diblock copolymers of poly(acrylic acid) (PAA) and poly(methyl acrylate) (PMA), PAA(52)-b-PMA(128), and subsequent covalent crosslinking by amidation upon reaction with 2,2'-(ethylenedioxy)bis(ethylamine) throughout the shell layer. The properties of these materials, including non-toxicity towards mammalian cells, non-immunogenicity within mice, and capability for polyvalent targeting, make them ideal candidates for utilization within biological systems. The synthesis of SCKs derivatized with Gd-III and designed for potential use as a unique nanometer-scale contrast agent for MRI applications is described herein. Utilization of an amino-functionalized diethylenetriaminepentaacetic acid-Gd analogue allowed for direct covalent conjugation throughout the hydrophilic shell layer of the SCKs and served to increase the rotational correlation lifetime of the Gd. In addition, the highly hydrated nature of the shell layer in which the Gd was located allowed for rapid water exchange; thus, the resulting material demonstrated large ionic relaxivities (39 s(-1) mM(-1)) in an applied magnetic field of 0.47 T at 40 degrees C and, as a result of the large loading capacity of the material, also demonstrated high molecular relaxivities (20 000 s(-1) mM(-1)).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An inverse methodology for the design of biologically loaded radio-frequency (RF) coils for magnetic resonance imaging applications is described. Free space time-harmonic electromagnetic Green's functions and de-emphasized B-1 target fields are used to calculate the current density on the coil cylinder. In theory, with the B-1 field de-emphasized in the middle of the RF transverse plane, the calculated current distribution can generate an internal magnetic field that can reduce the central overemphasis effect caused by field/tissue interactions at high frequencies. The current distribution of a head coil operating at 4 T (170 MHz) is calculated using an inverse methodology with de-emphasized B-1. target fields. An in-house finite-difference time-domain routine is employed to evaluate B-1 field and signal intensity inside a homogenous cylindrical phantom and then a complete human head model. A comparison with a conventional RF birdcage coil is carried out and demonstrates that this method can help in decreasing the normal bright region caused by field/tissue interactions in head images at 170 MHz and higher field strengths.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Contrast enhanced magnetic resonance imaging (CE MRI) is the most sensitive tool for screening women who are at high familial risk of breast cancer. Our aim in this study was to assess the cost-effectiveness of X-ray mammography (XRM), CE MRI or both strategies combined. In total, 649 women were enrolled in the MARIBS study and screened with both CE MRI and mammography resulting in 1881 screens and 1-7 individual annual screening events. Women aged 35-49 years at high risk of breast cancer, either because they have a strong family history of breast cancer or are tested carriers of a BRCA1, BRCA2 or TP53 mutation or are at a 50% risk of having inherited such a mutation, were recruited from 22 centres and offered annual MRI and XRM for between 2 and 7 years. Information on the number and type of further investigations was collected and specifically calculated unit costs were used to calculate the incremental cost per cancer detected. The numbers of cancer detected was 13 for mammography, 27 for CE MRI and 33 for mammography and CE MRI combined. In the subgroup of BRCA1 (BRCA2) mutation carriers or of women having a first degree relative with a mutation in BRCA1 (BRCA2) corresponding numbers were 3 (6), 12 (7) and 12 (11), respectively. For all women, the incremental cost per cancer detected with CE MRI and mammography combined was 28 pound 284 compared to mammography. When only BRCA1 or the BRCA2 groups were considered, this cost would be reduced to 11 pound 731 (CE MRI vs mammography) and 15 pound 302 (CE MRI and mammography vs mammography). Results were most sensitive to the unit cost estimate for a CE MRI screening test. Contrast-enhanced MRI might be a cost-effective screening modality for women at high risk, particularly for the BRCA1 and BRCA2 subgroups. Further work is needed to assess the impact of screening on mortality and health-related quality of life.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We propose phase diagrams for an imbalanced (unequal number of atoms or Fermi surface in two pairing hyperfine states) gas of atomic fermions near a broad Feshbach resonance using mean-field theory. Particularly, in the plane of interaction and polarization we determine the region for a mixed phase composed of normal and superfluid components. We compare our prediction of phase boundaries with the recent measurement and find a good qualitative agreement.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Government agencies responsible for riparian environments are assessing the combined utility of field survey and remote sensing for mapping and monitoring indicators of riparian zone condition. The objective of this work was to compare the Tropical Rapid Appraisal of Riparian Condition (TRARC) method to a satellite image based approach. TRARC was developed for rapid assessment of the environmental condition of savanna riparian zones. The comparison assessed mapping accuracy, representativeness of TRARC assessment, cost-effectiveness, and suitability for multi-temporal analysis. Two multi-spectral QuickBird images captured in 2004 and 2005 and coincident field data covering sections of the Daly River in the Northern Territory, Australia were used in this work. Both field and image data were processed to map riparian health indicators (RHIs) including percentage canopy cover, organic litter, canopy continuity, stream bank stability, and extent of tree clearing. Spectral vegetation indices, image segmentation and supervised classification were used to produce RHI maps. QuickBird image data were used to examine if the spatial distribution of TRARC transects provided a representative sample of ground based RHI measurements. Results showed that TRARC transects were required to cover at least 3% of the study area to obtain a representative sample. The mapping accuracy and costs of the image based approach were compared to those of the ground based TRARC approach. Results proved that TRARC was more cost-effective at smaller scales (1-100km), while image based assessment becomes more feasible at regional scales (100-1000km). Finally, the ability to use both the image and field based approaches for multi-temporal analysis of RHIs was assessed. Change detection analysis demonstrated that image data can provide detailed information on gradual change, while the TRARC method was only able to identify more gross scale changes. In conclusion, results from both methods were considered to complement each other if used at appropriate spatial scales.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The main aim of this thesis is to investigate the application of methods of differential geometry to the constraint analysis of relativistic high spin field theories. As a starting point the coordinate dependent descriptions of the Lagrangian and Dirac-Bergmann constraint algorithms are reviewed for general second order systems. These two algorithms are then respectively employed to analyse the constraint structure of the massive spin-1 Proca field from the Lagrangian and Hamiltonian viewpoints. As an example of a coupled field theoretic system the constraint analysis of the massive Rarita-Schwinger spin-3/2 field coupled to an external electromagnetic field is then reviewed in terms of the coordinate dependent Dirac-Bergmann algorithm for first order systems. The standard Velo-Zwanziger and Johnson-Sudarshan inconsistencies that this coupled system seemingly suffers from are then discussed in light of this full constraint analysis and it is found that both these pathologies degenerate to a field-induced loss of degrees of freedom. A description of the geometrical version of the Dirac-Bergmann algorithm developed by Gotay, Nester and Hinds begins the geometrical examination of high spin field theories. This geometric constraint algorithm is then applied to the free Proca field and to two Proca field couplings; the first of which is the minimal coupling to an external electromagnetic field whilst the second is the coupling to an external symmetric tensor field. The onset of acausality in this latter coupled case is then considered in relation to the geometric constraint algorithm.