845 resultados para guyed tower
Resumo:
El interés de este trabajo de grado consiste en proponer la construcción de un equipamiento híbrido en altura como alternativa de solución frente al crecimiento poblacional y la escasez de suelo presentes en la Unidad de Planeamiento Zonal- 71 Tibabuyes en la localidad de Suba. Se planea esta propuesta en el marco de un modelo de ocupación territorial denso y compacto contemplado en el Plan de Ordenamiento Territorial de Bogotá. Por tanto, el equipamiento híbrido en altura busca disminuir el déficit y mejorar el acceso a los equipamientos urbanos colectivos por parte de los habitantes de este territorio con el propósito de replantearse la manera de concebir las edificaciones tradicionales que brindan los servicios sociales.
Resumo:
Climate change science is increasingly concerned with methods for managing and integrating sources of uncertainty from emission storylines, climate model projections, and ecosystem model parameterizations. In tropical ecosystems, regional climate projections and modeled ecosystem responses vary greatly, leading to a significant source of uncertainty in global biogeochemical accounting and possible future climate feedbacks. Here, we combine an ensemble of IPCC-AR4 climate change projections for the Amazon Basin (eight general circulation models) with alternative ecosystem parameter sets for the dynamic global vegetation model, LPJmL. We evaluate LPJmL simulations of carbon stocks and fluxes against flux tower and aboveground biomass datasets for individual sites and the entire basin. Variability in LPJmL model sensitivity to future climate change is primarily related to light and water limitations through biochemical and water-balance-related parameters. Temperature-dependent parameters related to plant respiration and photosynthesis appear to be less important than vegetation dynamics (and their parameters) for determining the magnitude of ecosystem response to climate change. Variance partitioning approaches reveal that relationships between uncertainty from ecosystem dynamics and climate projections are dependent on geographic location and the targeted ecosystem process. Parameter uncertainty from the LPJmL model does not affect the trajectory of ecosystem response for a given climate change scenario and the primary source of uncertainty for Amazon 'dieback' results from the uncertainty among climate projections. Our approach for describing uncertainty is applicable for informing and prioritizing policy options related to mitigation and adaptation where long-term investments are required.
Resumo:
This paper presents an overview of the meteorology and planetary boundary layer structure observed during the NAMBLEX field campaign to aid interpretation of the chemical and aerosol measurements. The campaign has been separated into five periods corresponding to the prevailing synoptic condition. Comparisons between meteorological measurements ( UHF wind profiler, Doppler sodar, sonic aneometers mounted on a tower at varying heights and a standard anemometer) and the ECMWF analysis at 10 m and 1100 m identified days when the internal boundary layer was decoupled from the synoptic flow aloft. Generally the agreement was remarkably good apart from during period one and on a few days during period four when the diurnal swing in wind direction implies a sea/land breeze circulation near the surface. During these periods the origin of air sampled at Mace Head would not be accurately represented by back trajectories following the winds resolved in ECMWF analyses. The wind profiler observations give a detailed record of boundary layer structure including an indication of its depth, average wind speed and direction. Turbulence statistics have been used to assess the height to which the developing internal boundary layer, caused by the increased surface drag at the coast, reaches the sampling location under a wide range of marine conditions. Sampling conducted below 10 m will be impacted by emission sources at the shoreline in all wind directions and tidal conditions, whereas sampling above 15 m is unlikely to be affected in any of the wind directions and tidal heights sampled during the experiment.
Resumo:
Kites offer considerable potential as wind speed sensors—a role distinct from their traditional use as instrument-carrying platforms. In the sensor role, wind speed is measured by kite-line tension. A kite tether line tension meter is described here, using strain gauges mounted on an aluminum ring in a Wheatstone bridge electronic circuit. It exhibits a linear response to tension 19.5 mV N−1 with good thermal stability mean drift of −0.18 N °C−1 over 5–45 °C temperature range and a rapid time response 0.2 s or better. Field comparisons of tether line tension for a Rokkaku kite with a fixed tower sonic anemometer show an approximately linear tension-wind speed relationship over the range 1–6 ms−1. © 2010 American Institute of Physics. doi:10.1063/1.3465560
Resumo:
Two unique large buildings in the Kingdom of Bahrain were selected for make-over to sustainable buildings. These are the Almoayyed Tower (the first sky scraper) and the Bahrain International Circuit, BIC (The best world Formula 1 Circuit). The amount of electricity extracted from using renewable energy resource (solar and wind), integrated to the buildings-has been studied thoroughly. For the first building, the total solar electricity from the PV installed at the roof and the 4 vertical facades was found 3 017 500 kWh annually (3 million kWh), i.e. daily energy of 8219 kWh (enough to Supply electricity for 171 houses, each is rated as 2 kW house-in Europe the standard is 1.2 kW). This means that the annual solar electricity produced will be nearly 3 million kWh. This correspond to annual CO, reduction of 3000 t (assuming each kWh of energy from natural gas lead to emission of 1 kg of CO2). For the second building (BIC) the solar electricity from PV panels installed at the roof top, fixed at tilt angle of 26 degrees facing south, will provide annual solar electricity of is 2.8 x 10(6) kWh. The solar electricity from PV panels installed on the windows (12,000 m(2)) will be 45.3 x 10(6) kWh. This means that the total annual electrical power from PV panels (windows and roofs) will be nearly 12 MW (32 kW per day). The CO2 reduction will be 48,000 t. Under the carbon trading or CDM scheme the revenue (or the reward) would be (sic)480,000 million annually (the reward is (sic)10 per tonnes of CO2). The BIC circuit can have diversified electricity supply, i.e. from solar radiation (PV), from solar heat (CSP) and from wind (wind turbines), assuring its sustainability as well as reducing the CO2 emission.
Resumo:
In this work, IR thermography is used as a non-destructive tool for impact damage characterisation on thermoplastic E-glass/polypropylene composites for automotive applications. The aim of this experimentation was to compare impact resistance and to characterise damage patterns of different laminates, in order to provide indications for their use in components. Two E-glass/polypropylene composites, commingled ®Twintex (with three different weave structures: directional, balanced and 3-D) and random reinforced GMT, were in particular characterised. Directional and balanced Twintex were also coupled in a number of hybrid configurations with GMT to evaluate the possible use of GMT/Twintex hybrids in high-energy absorption components. The laminates were impacted using a falling weight tower, with impact energies ranging from 15 J to penetration. Using IR thermography during cooling down following a long pulse (3 s), impact damaged areas were characterised and the influence of weave structure on damage patterns was studied. IR thermography offered good accuracy for laminates with thickness not exceeding 3.5 mm: this appears to be a limit for the direct use of this method on components, where more refined signal treatment would probably be needed for impact damage characterisation.
Resumo:
Background & aims: Long term parenteral nutrition rarely supplies the long chain n-3 polyunsaturated fatty acids (PUFA), eicosapentaenoic acid (EPA), docosapentaenoic acid (DPA) and docosahexaenoic acid (DHA). The aim of this study was to assess long chain n-3 PUFA status in patients receiving home parenteral. nutrition (HPN). Methods: Plasma phospholipid fatty acids were measured in 64 adult HPN patients and compared with 54 age, sex and BMI matched controls. Logistic regression analysis was used to identify factors related to plasma fatty acid fractions in the HPN patients, and to identify factors associated with the risk of clinical. complications. Results: Plasma phospholipid fractions of EPA, DPA and DHA were significantly tower in patients receiving HPN. Factors independently associated with tow fractions included high parenteral energy provision, tow parenteral lipid intake, tow BMI and prolonged duration of HPN. Long chain n-3 PUFA fractions were not associated with incidence of either central venous catheter associated infection or central venous thrombosis. However, the fraction of EPA were inversely associated with plasma alkaline phosphatase concentrations. Conclusions: This study demonstrates abnormal long chain n-3 PUFA profiles in patients receiving HPN. Reduced fatty acid intake may be partly responsible. Fatty acid metabolism may also be altered. (C) 2008 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Resumo:
Aim: We examined the effect of meat fatty acids on lipid and apolipoprotein concentrations of very low density lipoprotein (VLDL) and chylomicron/chylomicron remnants in lipid fractions with a Svedberg flotation rate (S-f) 60-400 and S-f 20-60. Methods and results: Six healthy middle-aged men received in random order mixed meals enriched with saturated (SFA), polyunsaturated (PUFA) or monounsaturated (MUFA) fatty acids on 3 occasions. VLDL and chylomicron/chylomicron remnants in the lipid fractions were separated by immunoaffinity chromatography against apo B-100. In the S-f 60-400 chylomicron/chylomicron remnants, triacylglycerol and cholesterol concentrations were significantly tower following PUFA compared with SFA and MUFA (P <= 0.05). Apolipoprotein (apo) E responses were significantly higher after SFA in chylomicron/chylomicron remnants and VLDL compared with PUFA and MUFA (P < 0.007). However, apo B responses (particle number) were higher following MUFA than SFA (P = 0.039 for chylomicron/chylomicron remnants). Composition of the chylomicron/chylomicron remnants (expressed per particle) revealed differences in their triacylglycerol and apo E contents; in the Sf 60-400 fraction, SFA-rich chylomicron/chylomicron remnants contained significantly more triacylglycerol than MUFA (P = 0.028), more apo E than PUFA- and MUFA-rich particles (P < 0.05) and in the S-f 20-60 fraction, more apo E than MUFA (P = 0.009). Conclusion: There are specific differences in the composition of chylomicron/ chylomicron remnants formed after saturated compared with unsaturated fatty acid-rich meals which could determine their metabolic fate in the circulation and subsequent atherogenicity. (C) 2005 Elsevier B.V. All rights reserved.
Resumo:
There have been relatively few tracer experiments carried out that have looked at vertical plume spread in urban areas. In this paper we present results from two tracer (cyclic perfluorocarbon) experiments carried out in 2006 and 2007 in central London centred on the BT Tower as part of the REPARTEE (Regent’s Park and Tower Environmental Experiment) campaign. The height of the tower gives a unique opportunity to study vertical dispersion profiles and transport times in central London. Vertical gradients are contrasted with the relevant Pasquill stability classes. Estimation of lateral advection and vertical mixing times are made and compared with previous measurements. Data are then compared with a simple operational dispersion model and contrasted with data taken in central London as part of the DAPPLE campaign. This correlates dosage with non-dimensionalised distance from source. Such analyses illustrate the feasibility of the use of these empirical correlations over these prescribed distances in central London.
Resumo:
This volume reports on the excavations from 2002 to 2005 designed to investigate this transition, with the focus on the origins of Bishopstone village. Excavations adjacent to St Andrew’s churchyard revealed a dense swathe of later Anglo-Saxon (8th- to late 10th-/early 11th-century) habitation, including a planned complex of ‘timber halls’, and a unique cellared tower. The occupation encroached upon a pre-Conquest cemetery of 43 inhumations. The report provides a comprehensive analysis, interpretation and academic contextualisation of the archaeological discoveries brought to light by these excavations, the first to sample a later Anglo-Saxon rural settlement in East Sussex on an extensive scale. The inter-disciplinary approach appraises the historical and topographical evidence alongside that recovered during the excavations.
Resumo:
Urban boundary layers (UBLs) can be highly complex due to the heterogeneous roughness and heating of the surface, particularly at night. Due to a general lack of observations, it is not clear whether canonical models of boundary layer mixing are appropriate in modelling air quality in urban areas. This paper reports Doppler lidar observations of turbulence profiles in the centre of London, UK, as part of the second REPARTEE campaign in autumn 2007. Lidar-measured standard deviation of vertical velocity averaged over 30 min intervals generally compared well with in situ sonic anemometer measurements at 190 m on the BT telecommunications Tower. During calm, nocturnal periods, the lidar underestimated turbulent mixing due mainly to limited sampling rate. Mixing height derived from the turbulence, and aerosol layer height from the backscatter profiles, showed similar diurnal cycles ranging from c. 300 to 800 m, increasing to c. 200 to 850 m under clear skies. The aerosol layer height was sometimes significantly different to the mixing height, particularly at night under clear skies. For convective and neutral cases, the scaled turbulence profiles resembled canonical results; this was less clear for the stable case. Lidar observations clearly showed enhanced mixing beneath stratocumulus clouds reaching down on occasion to approximately half daytime boundary layer depth. On one occasion the nocturnal turbulent structure was consistent with a nocturnal jet, suggesting a stable layer. Given the general agreement between observations and canonical turbulence profiles, mixing timescales were calculated for passive scalars released at street level to reach the BT Tower using existing models of turbulent mixing. It was estimated to take c. 10 min to diffuse up to 190 m, rising to between 20 and 50 min at night, depending on stability. Determination of mixing timescales is important when comparing to physico-chemical processes acting on pollutant species measured simultaneously at both the ground and at the BT Tower during the campaign. From the 3 week autumnal data-set there is evidence for occasional stable layers in central London, effectively decoupling surface emissions from air aloft.
Resumo:
Nanoparticles emitted from road traffic are the largest source of respiratory exposure for the general public living in urban areas. It has been suggested that the adverse health effects of airborne particles may scale with the airborne particle number, which if correct, focuses attention on the nanoparticle (less than 100 nm) size range which dominates the number count in urban areas. Urban measurements of particle size distributions have tended to show a broadly similar pattern dominated by a mode centred on 20–30 nm diameter particles emitted by diesel engine exhaust. In this paper we report the results of measurements of particle number concentration and size distribution made in a major London park as well as on the BT Tower, 160 m high. These measurements taken during the REPARTEE project (Regents Park and BT Tower experiment) show a remarkable shift in particle size distributions with major losses of the smallest particle class as particles are advected away from the traffic source. In the Park, the traffic related mode at 20–30 nm diameter is much reduced with a new mode at <10 nm. Size distribution measurements also revealed higher number concentrations of sub-50 nm particles at the BT Tower during days affected by higher turbulence as determined by Doppler Lidar measurements and indicate a loss of nanoparticles from air aged during less turbulent conditions. These results suggest that nanoparticles are lost by evaporation, rather than coagulation processes. The results have major implications for understanding the impacts of traffic-generated particulate matter on human health.
Resumo:
Seven-part elegy for David Mather (1954-2010)
Resumo:
Recent excavations at Pre-Pottery Neolithic A (PPNA) WF16 in southern Jordan have revealed remarkable evidence of architectural developments in the early Neolithic. This sheds light on both special purpose structures and “domestic” settlement, allowing fresh insights into the development of increasingly sedentary communities and the social systems they supported. The development of sedentary communities is a central part of the Neolithic process in Southwest Asia. Architecture and ideas of homes and households have been important to the debate, although there has also been considerable discussion on the role of communal buildings and the organization of early sedentarizing communities since the discovery of the tower at Jericho. Recently, the focus has been on either northern Levantine PPNA sites, such as Jerf el Ahmar, or the emergence of ritual buildings in the Pre-Pottery Neolithic B of the southern Levant. Much of the debate revolves around a division between what is interpreted as domestic space, contrasted with “special purpose” buildings. Our recent evidence allows a fresh examination of the nature of early Neolithic communities.