1000 resultados para free pulse


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE Desmoid tumors are mesenchymal fibroblastic/myofibroblastic proliferations with locoregional aggressiveness and high ability to recur after initial treatment. We present the results of the largest series of sporadic desmoid tumors ever published to determine the prognostic factors of these rare tumors. PATIENTS AND METHODS Four hundred twenty-six patients with a desmoid tumor at diagnosis were included, and the following parameters were studied: age, sex, delay between first symptoms and diagnosis, tumor size, tumor site, previous history of surgery or trauma in the area of the primary tumor, surgical margins, and context of abdominal wall desmoids in women of child-bearing age during or shortly after pregnancy. We performed univariate and multivariate analysis for progression-free survival (PFS). Results In univariate analysis, age, tumor size, tumor site, and surgical margins (R2 v R0/R1) had a significant impact on PFS. PFS curves were not significantly different for microscopic assessment of surgical resection quality (R0 v R1). In multivariate analysis, age, tumor size, and tumor site had independent values. Three prognostic groups for PFS were defined on the basis of the number of independent unfavorable prognostic factors (0 or 1, 2, and 3). CONCLUSION This study clearly demonstrates that there are different prognostic subgroups of desmoid tumors that could benefit from different therapeutic strategies, including a wait-and-see policy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Northern Ireland Abdominal Aortic Aneurysm (AAA) Screening Programme began in June 2012 and offers AAA screening to all men aged 65 and over in Northern Ireland. All men in their 65th year receive an invite in the post. All men aged over 65 who have not been screened can request an appointment. The aim of the AAA screening programme is to reduce AAA-related mortality by providing systematic, population-based screening.� This poster was sent out to all GPs, GP practice managers and pharmacies as part of a professional information pack in the run-up to the launch of the programme. The poster is also distributed to relevant voluntary organisations and charities as a means of raising awareness among the target population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This report provides an overview of progress in reducing Second Hand Smoke (SHS) exposure in Northern Ireland that incorporates the five year review of smoke-free legislation, but also extends to a consideration of SHS exposure in non-work environments.  The report considers aspects of inequalities in SHS exposure in particular according to social disadvantage and with a focus on vulnerable subgroups of the population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulse wave velocity (PWV) is a surrogate of arterial stiffness and represents a non-invasive marker of cardiovascular risk. The non-invasive measurement of PWV requires tracking the arrival time of pressure pulses recorded in vivo, commonly referred to as pulse arrival time (PAT). In the state of the art, PAT is estimated by identifying a characteristic point of the pressure pulse waveform. This paper demonstrates that for ambulatory scenarios, where signal-to-noise ratios are below 10 dB, the performance in terms of repeatability of PAT measurements through characteristic points identification degrades drastically. Hence, we introduce a novel family of PAT estimators based on the parametric modeling of the anacrotic phase of a pressure pulse. In particular, we propose a parametric PAT estimator (TANH) that depicts high correlation with the Complior(R) characteristic point D1 (CC = 0.99), increases noise robustness and reduces by a five-fold factor the number of heartbeats required to obtain reliable PAT measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The decision to publish educational materials openly and under free licenses brings up the challenge of doing it in a sustainable way. Some lessons can be learned from the business models for production, maintenance and distribution of Free and Open Source Software. The Free Technology Academy (FTA) has taken on these challenges and has implemented some of these models. We briefly review the FTA educational programme, methodologies and organisation, and see to which extent these models are proving successful in the case of the FTA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Open educational resource (OER) initiatives have made the shift from being a fringe activity to one that is increasingly considered as a key component in both teaching and learning in higher education and in the fulfilment of universities' mission and goals. Although the reduction in the cost of materials is often cited as a potential benefit of OER, this potential benefit has not yet been realised in practice necessitating thoughtful consideration of various strategies for new OER initiatives such as the OpenContent directory at the University of Cape Town (UCT) in South Africa.This paper reviews the range of sustainability strategies mentioned in the literature, plots the results of a small-scale OER sustainability survey against these strategies and explains how these findings and other papers on OER initiatives were used to inform an in-house workshop at UCT to deliberate the future strategy for the sustainability of OER at UCT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study, we investigated the prevalence and intensity of Hectopsylla pulex infection in Molossus rufus and Molossus molossus, the parasite's choice of attachment site, and whether this host-parasite system varies with host size. Twenty-four bats were captured by hand from the roof of a house in Southeastern Brazil. M. rufus exhibited a prevalence of 71.4% and the mean intensity averaged 5 ectoparasites per bat. M. molossus exhibited a prevalence of 90%, and the average mean intensity was 2.11 ectoparasites. The attachment sites were: ear, tragus, shoulder blade and tibia, anus, wing, axilla, mouth and dactylopatagium. A positive correlation was observed between the bats' weight and the number of fleas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glycol ethers still continue to be a workplace hazard due to their important use on an industrial scale. Currently, chronic occupational exposures to low levels of xenobiotics become increasingly relevant. Thus, sensitive analytical methods for detecting biomarkers of exposure are of interest in the field of occupational exposure assessment. 1-Methoxy-2-propanol (1M2P) is one of the dominant glycol ethers and the unmetabolized urinary fraction has been identified to be a good biological indicator of exposure. An existing analytical method including a solid-phase extraction and derivatization before GC/FID analysis is available but presents some disadvantages. We present here an alternative method for the determination of urinary 1M2P based on the headspace gas chromatography technique. We determined the 1M2P values by the direct headspace method for 47 samples that had previously been assayed by the solid-phase extraction and derivatization gas chromatography procedure. An inter-method comparison based on a Bland-Altman analysis showed that both techniques can be used interchangeably. The alternative method showed a tenfold lower limit of detection (0.1 mg/L) as well as good accuracy and precision which were determined by several urinary 1M2P analyses carried out on a series of urine samples obtained from a human volunteer study. The within- and between-run precisions were generally about 10%, which corresponds to the usual injection variability. We observed that the differences between the results obtained with both methods are not clinically relevant in comparison to the current biological exposure index of urinary 1M2P. Accordingly, the headspace gas chromatography technique turned out to be a more sensitive, accurate, and simple method for the determination of urinary 1M2P.[Authors]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Magnetic resonance imaging (MRI) of pacemakers is a relative contraindication because of the risks to the patient from potentially hazardous interactions between the MRI and the pacemaker system. Chest scans (ie, cardiac magnetic resonance scans) are of particular importance and higher risk. The previously Food and Drug Administration-approved magnetic resonance conditional system includes positioning restrictions, limiting the powerful utility of MRI. OBJECTIVE: To confirm the safety and effectiveness of a pacemaker system designed for safe whole body MRI without MRI scan positioning restrictions. METHODS: Primary eligibility criteria included standard dual-chamber pacing indications. Patients (n = 263) were randomized in a 2:1 ratio to undergo 16 chest and head scans at 1.5 T between 9 and 12 weeks postimplant (n = 177) or to not undergo MRI (n = 86) post-implant. Evaluation of the pacemaker system occurred immediately before, during (monitoring), and after MRI, 1-week post-MRI, and 1-month post-MRI, and similarly for controls. Primary end points measured the MRI-related complication-free rate for safety and compared pacing capture threshold between MRI and control subjects for effectiveness. RESULTS: There were no MRI-related complications during or after MRI in subjects undergoing MRI (n = 148). Differences in pacing capture threshold values from pre-MRI to 1-month post-MRI were minimal and similar between the MRI and control groups. CONCLUSIONS: This randomized trial demonstrates that the Advisa MRI pulse generator and CapSureFix MRI 5086MRI lead system is safe and effective in the 1.5 T MRI environment without positioning restrictions for MRI scans or limitations of body parts scanned.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Respiratory motion correction remains a challenge in coronary magnetic resonance imaging (MRI) and current techniques, such as navigator gating, suffer from sub-optimal scan efficiency and ease-of-use. To overcome these limitations, an image-based self-navigation technique is proposed that uses "sub-images" and compressed sensing (CS) to obtain translational motion correction in 2D. The method was preliminarily implemented as a 2D technique and tested for feasibility for targeted coronary imaging. METHODS: During a 2D segmented radial k-space data acquisition, heavily undersampled sub-images were reconstructed from the readouts collected during each cardiac cycle. These sub-images may then be used for respiratory self-navigation. Alternatively, a CS reconstruction may be used to create these sub-images, so as to partially compensate for the heavy undersampling. Both approaches were quantitatively assessed using simulations and in vivo studies, and the resulting self-navigation strategies were then compared to conventional navigator gating. RESULTS: Sub-images reconstructed using CS showed a lower artifact level than sub-images reconstructed without CS. As a result, the final image quality was significantly better when using CS-assisted self-navigation as opposed to the non-CS approach. Moreover, while both self-navigation techniques led to a 69% scan time reduction (as compared to navigator gating), there was no significant difference in image quality between the CS-assisted self-navigation technique and conventional navigator gating, despite the significant decrease in scan time. CONCLUSIONS: CS-assisted self-navigation using 2D translational motion correction demonstrated feasibility of producing coronary MRA data with image quality comparable to that obtained with conventional navigator gating, and does so without the use of additional acquisitions or motion modeling, while still allowing for 100% scan efficiency and an improved ease-of-use. In conclusion, compressed sensing may become a critical adjunct for 2D translational motion correction in free-breathing cardiac imaging with high spatial resolution. An expansion to modern 3D approaches is now warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Twenty per cent of sentinel lymph node (SLN)-positive melanoma patients have positive non-SLN lymph nodes in completion lymph node dissection (CLND). We investigated SLN tumour load, non-sentinel positivity and disease-free survival (DFS) to assess whether certain patients could be spared CLND. Sentinel lymph node biopsy was performed on 392 patients between 1999 and 2005. Median observation period was 38.8 months. Sentinel lymph node tumour load did not predict non-SLN positivity: 30.8% of patients with SLN macrometastases (> or =2 mm) and 16.4% with micrometastases (< or =2 mm) had non-SLN positivity (P=0.09). Tumour recurrences after positive SLNs were more than twice as frequent for SLN macrometastases (51.3%) than for micrometastases (24.6%) (P=0.005). For patients with SLN micrometastases, the DFS analysis was worse (P=0.003) when comparing those with positive non-SLNs (60% recurrences) to those without (17.6% recurrences). This difference did not translate into significant differences in DFS: patients with SLN micrometastasis, either with (P=0.022) or without additional positive non-SLNs (P<0.0001), fared worse than patients with tumour-free SLNs. The 2-mm cutoff for SLN tumour load accurately predicts differences in DFS. Non-SLN positivity in CLND, however, cannot be predicted. Therefore, contrary to other studies, no recommendations concerning discontinuation of CLND based on SLN tumour load can be deduced.