OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, most always hinder the performance of clinical trials. Thus, in vitro studies become an important source of information for the understanding of biomechanical events on implant-supported prostheses, although study results cannot be considered reliable unless validation studies are conducted. The purpose of this work was to validate an artificial experimental model based on its modulus of elasticity, to simulate the performance of human bone in vivo in biomechanical studies of implant-supported prostheses. MATERIAL AND METHODS: In this study, fast-curing polyurethane (F16 polyurethane, Axson) was used to build 40 specimens that were divided into five groups. The following reagent ratios (part A/part B) were used: Group A (0.5/1.0), Group B (0.8/1.0), Group C (1.0/1.0), Group D (1.2/1.0), and Group E (1.5/1.0). A universal testing machine (Kratos model K - 2000 MP) was used to measure modulus of elasticity values by compression. RESULTS: Mean modulus of elasticity values were: Group A - 389.72 MPa, Group B - 529.19 MPa, Group C - 571.11 MPa, Group D - 470.35 MPa, Group E - 437.36 MPa. CONCLUSION: The best mechanical characteristics and modulus of elasticity value comparable to that of human trabecular bone were obtained when A/B ratio was 1:1.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Paracoccidioides brasiliensis causes paracoccidioidomycosis (PCM) that is one of the most prevalent systemic human mycoses in Latin America. Armadillos show a high incidence of PCM infection and could, therefore, be a natural reservoir for this fungus. In this study were compared the virulence profiles of isolates obtained from nine-banded armadillos (Dasypus novemcinctus) (PbT1 and PbT4) and isolates from PCM patients (Pb265 and Bt83). Pathogenicity was evaluated by fungal load and analysis of colony morphology. Immunity against the fungus was tested by delayed type hypersensitivity test (DTH) and antibody quantification by ELISA. The higher virulence of PbT1 and PbT4 was suggested by higher fungal load in spleen and lungs. Armadillo isolates and Bt83 presented a cotton-like surface contrasting with the cerebriform appearance of Pb265. All isolates induced cellular and humoral immune responses in infected BALB/c mice. DTH reactions were similarly induced by the four isolates, however, a great variability was observed in specific antibody levels, being the highest ones induced by Bt83 and PbT4. The present work confirms that armadillos harbor P. brasiliensis, whose multiplication and induced immunity in experimentally infected mice are heterogeneous, resembling the behavior of isolates from human PCM. This study reinforces the possibility that armadillos play an important role in the biological cycle of this pathogen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Neste trabalho é apresentado um experimento incluído no contexto de experimentos longos adotado nas disciplinas experimentais de eletricidade, magnetismo e óptica, e consiste na caracterização de um seletor de velocidades que funciona com campos elétricos e magnéticos cruzados. Utiliza-se um tubo de raios catódicos para gerar um feixe de elétrons. As placas de deflexão vertical do tubo geram o campo elétrico e um par de bobinas, com os eixos perpendiculares ao eixo do tubo, gera o campo magnético. São realizados estudos de trajetória dos elétrons com auxílio de um programa de simulação de elétrons.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Este trabalho teve por objetivo aplicar um procedimento para diagnóstico e modelo de inspeção higiênico-sanitária em estabelecimentos varejistas de alimentos, no Município de Ibiúna, Estado de São Paulo, Brasil, e analisar os resultados com vistas a atingir os objetivos da vigilância sanitária. O trabalho foi desenvolvido durante seis meses em 19 estabelecimentos varejistas de alimentos classificados como padarias, restaurantes e açougues, sendo que na primeira inspeção realizou-se o diagnóstico da situação, com a identificação das não conformidades e avaliação das condições higiênico-sanitárias dos estabelecimentos e foi obtida a pontuação média de 64. Após esta etapa iniciaram-se retornos programados aos estabelecimentos pela equipe da vigilância sanitária a fim de verificar a evolução das adequações sanitárias. No diagnóstico e em todos os retornos programados foi aplicado roteiro de inspeção e produção de relatórios detalhados destinados aos proprietários. Todos os manipuladores de alimentos dos estabelecimentos inspecionados foram capacitados em relação a conceitos básicos de higiene em alimentos. Os resultados mostraram que, após três retornos de inspeções em cada estabelecimento, 100% apresentaram-se como satisfatórios, com pontuação média de 90. O modelo de inspeção sanitária aplicado mostrou-se viável para a promoção da segurança alimentar.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work evaluated the infection of opossums (Didelphis aurita) by Rickettsia felis, Rickettsia bellii, and Rickettsia parkeri and their role as amplifier hosts for horizontal transmission to Amblyomma cajennense and/or Amblyomma dubitatum ticks. Infection in D. aurita was induced by intraperitoneal inoculation with R. felis (n = 4 opossums), R. bellii (n = 4), and R. parkeri (n = 2). Another group of six opossums were inoculated intraperitoneally with Leibovitz-15 sterile culture medium, representing the uninfected groups (n = 2 opossums simultaneously to each infected group). Opossum blood samples collected during the study were used for DNA extraction, followed by real-time polymerase chain reaction targeting the rickettsial gene gltA, hematology, and detection of Rickettsia spp.-reactive antibodies by indirect immunofluorescence assay. Opossums were infested with uninfected A. cajennense and/or A. dubitatum for 30 days postinoculation (DPI). Flat ticks molted from ticks fed on opossums were allowed to feed on uninfected rabbits, which were tested for seroconversion by immunofluorescence assay. Samples of flat ticks were also tested by real-time polymerase chain reaction. Inoculated opossums showed no clinical abnormalities. Antibodies to Rickettsia spp. were first detected at the second to fourth DPI, with detectable titers until the 150th DPI. Rickettsemia was detected only in one opossum inoculated with R. parkeri, at the eighth DPI. Only one A. cajennense tick (2.0%) previously fed on a R. parkeri-inoculated opossum became infected. None of the rabbits infested with opossum-derived ticks seroconverted. The study demonstrated that R. felis, R. bellii, and R. parkeri were capable to produce antibody response in opossums, however, with undetectable rickettsemia for R. felis and R. bellii, and very low rickettsemia for R. parkeri. Further studies must be done with different strains of these rickettsiae, most importantly the strains that have never gone through in vitro passages.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: The dust mite Blomia tropicalis is an important source of aeroallergens in tropical areas. Although a mouse model for B. tropicalis extract (BtE)-induced asthma has been described, no study comparing different mouse strains in this asthma model has been reported. The relevance and reproducibility of experimental animal models of allergy depends on the genetic background of the animal, the molecular composition of the allergen and the experimental protocol. Objectives: This work had two objectives. The first was to study the anti-B. tropicalis allergic responses in different mouse strains using a short-term model of respiratory allergy to BtE. This study included the comparison of the allergic responses elicited by BtE with those elicited by ovalbumin in mice of the strain that responded better to BtE sensitization. The second objective was to investigate whether the best responder mouse strain could be used in an experimental model of allergy employing relatively low BtE doses. Methods: Groups of mice of four different syngeneic strains were sensitized subcutaneously with 100 mu g of BtE on days 0 and 7 and challenged four times intranasally, at days 8, 10, 12, and 14, with 10 mu g of BtE. A/J mice, that were the best responders to BtE sensitization, were used to compare the B. tropicalis-specific asthma experimental model with the conventional experimental model of ovalbumin (OVA)-specific asthma. A/J mice were also sensitized with a lower dose of BtE. Results: Mice of all strains had lung inflammatory-cell infiltration and increased levels of anti-BtE IgE antibodies, but these responses were significantly more intense in A/J mice than in CBA/J, BALB/c or C57BL/6J mice. Immunization of A/J mice with BtE induced a more intense airway eosinophil influx, higher levels of total IgE, similar airway hyperreactivity to methacholine but less intense mucous production, and lower levels of specific IgE, IgG1 and IgG2 antibodies than sensitization with OVA. Finally, immunization with a relatively low BtE dose (10 mu g per subcutaneous injection per mouse) was able to sensitize A/J mice, which were the best responders to high-dose BtE immunization, for the development of allergy-associated immune and lung inflammatory responses. Conclusions: The described short-term model of BtE-induced allergic lung disease is reproducible in different syngeneic mouse strains, and mice of the A/J strain was the most responsive to it. In addition, it was shown that OVA and BtE induce quantitatively different immune responses in A/J mice and that the experimental model can be set up with low amounts of BtE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Hybrid active-passive damping treatments combine the reliability, low cost and robustness of viscoelastic damping treatments and the high-performance, modal selective and adaptive piezoelectric active control. Numerous hybrid damping treatments have been reported in the literature. They differ mainly by the relative positions of viscoelastic treatments, sensors and piezoelectric actuators. In this work we present an experimental analysis of three active-passive damping design configurations applied to a cantilever beam. In particular, two design configurations based on the extension mode of piezoelectric actuators combined with viscoelastic constrained layer damping treatments and one design configuration with shear piezoelectric actuators embedded in a sandwich beam with viscoelastic core are analyzed. For comparison purposes, a purely active design configuration with an extension piezoelectric actuator bonded to an elastic beam is also analyzed. The active-passive damping performance of the four design configurations is compared. Results show that active-passive design configurations provide more reliable and wider-range damping performance than the purely active configuration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper aims to formulate and investigate the application of various nonlinear H(infinity) control methods to a fiee-floating space manipulator subject to parametric uncertainties and external disturbances. From a tutorial perspective, a model-based approach and adaptive procedures based on linear parametrization, neural networks and fuzzy systems are covered by this work. A comparative study is conducted based on experimental implementations performed with an actual underactuated fixed-base planar manipulator which is, following the DEM concept, dynamically equivalent to a free-floating space manipulator. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Leakage reduction in water supply systems and distribution networks has been an increasingly important issue in the water industry since leaks and ruptures result in major physical and economic losses. Hydraulic transient solvers can be used in the system operational diagnosis, namely for leak detection purposes, due to their capability to describe the dynamic behaviour of the systems and to provide substantial amounts of data. In this research work, the association of hydraulic transient analysis with an optimisation model, through inverse transient analysis (ITA), has been used for leak detection and its location in an experimental facility containing PVC pipes. Observed transient pressure data have been used for testing ITA. A key factor for the success of the leak detection technique used is the accurate calibration of the transient solver, namely adequate boundary conditions and the description of energy dissipation effects since PVC pipes are characterised by a viscoelastic mechanical response. Results have shown that leaks were located with an accuracy between 4-15% of the total length of the pipeline, depending on the discretisation of the system model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this work is to study the wheel/workpiece dynamic interactions in high-speed grinding using vitrified CBN wheel and DTG (difficult to grind) work materials. This problem is typical in the grinding of engine valve heads. The influence of tangential force per abrasive grain was investigated as an important control variable for the determination of G ratio. Experiments were carried out to observe the influence of vibrations in the wheel wear. The measurements of acoustic emission (AE) and vibration signals helped in identifying the correlation between the dynamic interactions (produced by forced random excitation) and the wheel wear. The wheel regenerative chatter phenomenon was observed by using the wheel mapping technique. (c) 2008 CIRP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents the results of an experimental study on pure refrigerant R-134a and refrigerant-oil mixtures flowing through capillary tubes in order to analyse the oil influence in component performance. Tests were carried out for capillary tubes internal diameters of 0.69 mm and 0.82 mm, condensing temperatures ranging from 40 degrees C to 50 degrees C, and subcooling degrees between 3 degrees C and 12 degrees C. Pure refrigerant flow measurements were compared to those for refrigerant-oil mixtures with oil concentrations of 1.0% and 3.0%. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Flow pumps have been developed for classical applications in Engineering, and are important instruments in areas such as Biology and Medicine. Among applications for this kind of device we notice blood pump and chemical reagents dosage in Bioengineering. Furthermore, they have recently emerged as a viable thermal management solution for cooling applications in small-scale electronic devices. This work presents the performance study of a novel principle of a piezoelectric flow pump which is based oil the use of a bimorph piezoelectric actuator inserted in fluid (water). Piezoelectric actuators have some advantages over classical devices, such as lower noise generation and ease of miniaturization. The main objective is the characterization of this piezoelectric pump principle through computational simulations (using finite element software), and experimental tests through a manufactured prototype. Computational data, Such as flow rate and pressure curves, have also been compared with experimental results for validation purposes. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents new experimental results of Vortex-Induced Vibration (VIV) on inclined cylinders. Models are mounted on a low damping air-bearing elastic base with one degree-of-freedom, constrained to oscillate only in the transverse direction to a free stream. The Reynolds number varied in the range 2000 less than or similar to Re less than or similar to 8000. New measurements on the dynamic response oscillations of inclined cylinders, due to VIV, are compared with previous experiments of a vertical cylinder. Models with circular and elliptical cross sections have been tested. The purpose of this work is to check the validity of the normal velocity correction of VIV studies of inclined structures. The results show that the reduced velocity range, in which the upper and lower branches of VIV occurs, is similar to the vertical cylinder case if the proper projected velocity is considered. Tests have been conducted to support this observation with inclinations up to 45 degrees. We have also observed that the amplitudes of oscillation of the inclined circular cylinder are comparable, but slightly lower than, to the amplitudes observed in the vertical cylinder experiments. Measured forces and added mass also show similar behaviour. However, for cases with an elliptical cylinder, the amplitudes of oscillation are considerably lower than those observed for a circular cylinder. This difference is explained by the higher added mass of the elliptical cylinder. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, the oxidation of the model pollutant phenol has been studied by means of the O(3), O(3)-UV, and O(3)-H(2)O(2) processes. Experiments were carried out in a fed-batch system to investigate the effects of initial dissolved organic carbon concentration, initial, ozone concentration in the gas phase, the presence or absence of UVC radiation, and initial hydrogen peroxide concentration. Experimental results were used in the modeling of the degradation processes by neural networks in order to simulate DOC-time profiles and evaluate the relative importance of process variables.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cooling towers are widely used in many industrial and utility plants as a cooling medium, whose thermal performance is of vital importance. Despite the wide interest in cooling tower design, rating and its importance in energy conservation, there are few investigations concerning the integrated analysis of cooling systems. This work presents an approach for the systemic performance analysis of a cooling water system. The approach combines experimental design with mathematical modeling. An experimental investigation was carried out to characterize the mass transfer in the packing of the cooling tower as a function of the liquid and gas flow rates, whose results were within the range of the measurement accuracy. Then, an integrated model was developed that relies on the mass and heat transfer of the cooling tower, as well as on the hydraulic and thermal interactions with a heat exchanger network. The integrated model for the cooling water system was simulated and the temperature results agree with the experimental data of the real operation of the pilot plant. A case study illustrates the interaction in the system and the need for a systemic analysis of cooling water system. The proposed mathematical and experimental analysis should be useful for performance analysis of real-world cooling water systems. (C) 2009 Elsevier Ltd. All rights reserved.