840 resultados para discotics, columar liquid crystals, solid-state NMR, liquid crystal engineering


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A novel tunable liquid crystal microaxicon array is proposed and experimentally demonstrated. The proposed structure is capable of generating tunable axicons (thousands of elements) of micrometric size, with simple control (four control voltages) and low voltage, and is totally reconfigurable. Depending on the applied voltages, control over the diameter, as well as the effective wedge angle, can be achieved. Controls over the diameter ranging from 107 to 77 μm have been demonstrated. In addition, a control over the phase profile tunability, from 12π to 24π radians, has been demonstrated. This result modifies the effective cone angle. The diameter tunability, as well the effective cone angle, results in a control over the nondiffractive Bessel beam distance. The RMS wavefront deviation from the ideal axicon is only λ∕3. The proposed device has several advantages over the existing microaxicon arrays, including being simple having a low cost. The device could contribute to developing new applications and to reducing the fabrication costs of current devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, the design and experimental characterization of a tunable microstrip bandpass filter based on liquid crystal technology are presented. A reshaped microstrip dual-mode filter structure has been used in order to improve the device performance. Specifically, the aim is to increase the pass-band return loss of the filter by narrowing the filter bandwidth. Simulations confirm the improvement of using this new structure, achieving a pass-band return loss increase of 1.5 dB at least. Because of the anisotropic properties of LC molecules, a filter central frequency shift from 4.688 GHz to 5.045 GHz, which means a relative tuning range of 7.3%, is measured when an external AC voltage from 0 Vrms to 15 Vrms is applied to the device.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Proteins play an important role in the biological mechanisms controlling hard tissue development, but the details of molecular recognition at inorganic crystal interfaces remain poorly characterized. We have applied a recently developed homonuclear dipolar recoupling solid-state NMR technique, dipolar recoupling with a windowless sequence (DRAWS), to directly probe the conformation of an acidic peptide adsorbed to hydroxyapatite (HAP) crystals. The phosphorylated hexapeptide, DpSpSEEK (N6, where pS denotes phosphorylated serine), was derived from the N terminus of the salivary protein statherin. Constant-composition kinetic characterization demonstrated that, like the native statherin, this peptide inhibits the growth of HAP seed crystals when preadsorbed to the crystal surface. The DRAWS technique was used to measure the internuclear distance between two 13C labels at the carbonyl positions of the adjacent phosphoserine residues. Dipolar dephasing measured at short mixing times yielded a mean separation distance of 3.2 ± 0.1 Å. Data obtained by using longer mixing times suggest a broad distribution of conformations about this average distance. Using a more complex model with discrete α-helical and extended conformations did not yield a better fit to the data and was not consistent with chemical shift analysis. These results suggest that the peptide is predominantly in an extended conformation rather than an α-helical state on the HAP surface. Solid-state NMR approaches can thus be used to determine directly the conformation of biologically relevant peptides on HAP surfaces. A better understanding of peptide and protein conformation on biomineral surfaces may provide design principles useful for the modification of orthopedic and dental implants with coatings and biological growth factors that are designed to enhance biocompatibility with surrounding tissue.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent advances in single molecule manipulation methods offer a novel approach to investigating the protein folding problem. These studies usually are done on molecules that are naturally organized as linear arrays of globular domains. To extend these techniques to study proteins that normally exist as monomers, we have developed a method of synthesizing polymers of protein molecules in the solid state. By introducing cysteines at locations where bacteriophage T4 lysozyme molecules contact each other in a crystal and taking advantage of the alignment provided by the lattice, we have obtained polymers of defined polarity up to 25 molecules long that retain enzymatic activity. These polymers then were manipulated mechanically by using a modified scanning force microscope to characterize the force-induced reversible unfolding of the individual lysozyme molecules. This approach should be general and adaptable to many other proteins with known crystal structures. For T4 lysozyme, the force required to unfold the monomers was 64 ± 16 pN at the pulling speed used. Refolding occurred within 1 sec of relaxation with an efficiency close to 100%. Analysis of the force versus extension curves suggests that the mechanical unfolding transition follows a two-state model. The unfolding forces determined in 1 M guanidine hydrochloride indicate that in these conditions the activation barrier for unfolding is reduced by 2 kcal/mol.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Here we present the successful application of the microarray technology platform to the analysis of DNA polymorphisms. Using the rice genome as a model, we demonstrate the potential of a high-throughput genome analysis method called Diversity Array Technology, DArT‘. In the format presented here the technology is assaying for the presence (or amount) of a specific DNA fragment in a representation derived from the total genomic DNA of an organism or a population of organisms. Two different approaches are presented: the first involves contrasting two representations on a single array while the second involves contrasting a representation with a reference DNA fragment common to all elements of the array. The Diversity Panels created using this method allow genetic fingerprinting of any organism or group of organisms belonging to the gene pool from which the panel was developed. Diversity Arrays enable rapid and economical application of a highly parallel, solid-state genotyping technology to any genome or complex genomic mixtures.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The observation of light metal ions in nucleic acids crystals is generally a fortuitous event. Sodium ions in particular are notoriously difficult to detect because their X-ray scattering contributions are virtually identical to those of water and Na+…O distances are only slightly shorter than strong hydrogen bonds between well-ordered water molecules. We demonstrate here that replacement of Na+ by K+, Rb+ or Cs+ and precise measurements of anomalous differences in intensities provide a particularly sensitive method for detecting alkali metal ion-binding sites in nucleic acid crystals. Not only can alkali metal ions be readily located in such structures, but the presence of Rb+ or Cs+ also allows structure determination by the single wavelength anomalous diffraction technique. Besides allowing identification of high occupancy binding sites, the combination of high resolution and anomalous diffraction data established here can also pinpoint binding sites that feature only partial occupancy. Conversely, high resolution of the data alone does not necessarily allow differentiation between water and partially ordered metal ions, as demonstrated with the crystal structure of a DNA duplex determined to a resolution of 0.6 Å.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background To evaluate and report the visual, refractive, and aberrometric outcomes of LASIK for the correction of low to moderate hyperopia in a pilot group using a commercially available solid-state laser. Methods Prospective pilot study including 11 consecutive eyes with low to moderate hyperopia of six patients undergoing LASIK surgery using the Pulzar Z1 solid-state laser (CustomVis Laser Pty Ltd., currently CV Laser). Visual, refractive, and aberrometric changes were evaluated. Potential complications were evaluated as well. Mean follow-up time was 6.6 months (range, 3 to 11 months). Results A significant improvement in LogMAR uncorrected distance visual acuity (UDVA) was observed postoperatively (p = 0.01). No significant change was detected in LogMAR corrected distance visual acuity (CDVA) (p = 0.21). Postoperative LogMAR UDVA was 0.1 (about 20/25) or better in ten eyes (90.9 %). Mean overall efficacy and safety indices were 1.03 and 1.12. Postoperatively, no losses of lines of CDVA were observed. Postoperative spherical equivalent was within ±1.00 D in ten eyes (90.9 %). With regard to aberrations, no statistically significant changes were found in higher order and primary coma RMS postoperatively (p ≥ 0.21), and only minimal but statistically significant negativization of primary spherical aberration (p = 0.02) was observed. No severe complications were observed. Conclusion LASIK surgery using the solid-state laser technology seems to be a useful procedure for the correction of low to moderate hyperopia, with minimal induction of higher order aberrations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of the difference between preoperative corneal and refractive astigmatism [ocular residual astigmatism (ORA)] on outcomes obtained after laser in situ keratomileusis (LASIK) surgery for correction of myopic astigmatism using the solid-state laser technology. Methods: One hundred one consecutive eyes with myopia or myopic astigmatism of 55 patients undergoing LASIK surgery using the Pulzar Z1 solid-state laser (CustomVis Laser Pty Ltd, currently CV Laser) were included. Visual and refractive changes at 6 months postoperatively and changes in ORA and anterior corneal astigmatism and posterior corneal astigmatism (PCA) were analyzed. Results: Postoperatively, uncorrected distance visual acuity improved significantly (P < 0.01). Likewise, refractive cylinder magnitude and spherical equivalent were reduced significantly (P < 0.01). In contrast, no significant changes were observed in ORA magnitude (P = 0.81) and anterior corneal astigmatism (P = 0.12). The mean overall efficacy and safety indices were 0.96 and 1.01, respectively. These indices were not correlated with preoperative ORA (r = −0.15, P = 0.15). Furthermore, a significant correlation was found between ORA (r = 0.81, P < 0.01) and PCA postoperatively, but not preoperatively (r = 0.12, P = 0.25). Likewise, a significant correlation of ORA with manifest refraction was only found postoperatively (r = −0.38, P < 0.01). Conclusions: The magnitude of ORA does not seem to be a predictive factor of efficacy and safety of myopic LASIK using a solid-state laser platform. The higher relevance of PCA after surgery in some cases may explain the presence of unexpected astigmatic residual refractive errors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"January 1957 (TISE Issuance Date)."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"July 1959 (TIS Issuance Date)."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"January 1964 (DTIE Issuance Date)."

Relevância:

100.00% 100.00%

Publicador:

Resumo:

National Highway Traffic Safety Administration, Washington, D.C.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"June 1961 (OIT Issuance Date)."