959 resultados para cut-to-length operations


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to verify the average fiber length and the juvenile and mature wood zones from Hevea brasiliensis proveniences from a reforestation area in São Paulo, Brazil. For this purpose, five Hevea brasiliensis trees were randomly collected from a 50-year-old plantation, located in Balsamo, São Paulo, Brazil. The trees were cut and five flat sawn boards were obtained. The juvenile and mature wood zones were determined by fiber length measurement from the pith to the bark. The results showed that: (a) the juvenile wood of this species occurred approx. between 40 and 55 mm, from the pith, and from this point forward, the mature wood zone was found; (b) there was a significant difference between the average fiber length of juvenile wood (1.26 mm) and mature wood (1.51 mm).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Absorbance detection in capillary electrophoresis (CE), offers an excellent mass sensitivity, but poor concentration detection limits owing to very small injection volumes (normally I to 10 nL). This aspect can be a limiting factor in the applicability of CE/UV to detect species at trace levels, particularly pesticide residues. In the present work, the optical path length of an on-column detection cell was increased through a proper connection of the column (75 mu m i.d.) to a capillary detection cell of 180 mu m optical path length in order to improve detectability. It is shown that the cell with an extended optical path length results in a significant gain in terms of signal to noise ratio. The effect of the increase in the optical path length has been evaluated for six pesticides, namely, carbendazim, thiabendazole, imazalil, procymidone triadimefon, and prochloraz. The resulting optical enhancement of the detection cell provided detection limits of ca. 0.3 mu g/mL for the studied compounds, thus enabling the residue analysis by CE/UV.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objectives: the purpose of this study is to employ optical microscopy to measure the thickness of the hybrid layer and the penetration (tags) of an aggressive self-etching adhesive system into sound dentin.Methods: occtusat cavities were prepared in 40 extracted human posterior teeth. The prepared teeth were randomly assigned to four experimental groups with 10 specimens each. The self-etching adhesive system Adper Prompt L-Pop was applied to the dentin surface as follows: Group 1: cavosurface enamel was etched for 60 s and dentin for 20 s with 35% phosphoric acid get, immediately followed by application of the self -etching adhesive with a brush to the entire cavity for 15 s; Groups 2, 3, and 4: no pre-etching was performed, and the self -etching adhesive was applied to both enamel and dentin for 15, 30 and 45 s, respectively. After curing, the cavities were fitted with composite resin Fittek Z250. Afterwards, the teeth were decalcified and the restorations were carefully removed for later embedding in paraffin. The specimens were serially sectioned at 6 mu m of thickness and sequentially mounted in glass slides. These sections were stained with Brown and Brenn staining for posterior analysis and measurement of the hybrid layer and resin tags on a tight microscope with a micrometric ocular 40/075. The results were submitted to analysis of variance at the 5% level.Results: whenever there was significance, the Tukey test was applied at the 5% level. The specimens receiving application of acid etching before the selfetching. adhesive displayed a larger thickness of the hybrid layer; on the other hand, specimens receiving only application of the self -etching adhesive on dentin for 15, 30 and 45 s exhibited similar thickness of the hybrid layer. As regards the resin tags, no statistically significant differences could be found between the study groups.Conclusions: it could be concluded that the increase in the time of application of the self-etching adhesive Adper Prompt L-Pop did not significantly influence the formation and thickness of hybrid layer, as well as its penetration into the sound dentin surface. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of surface hydration state and application method on the microtensile bond strength of one-step self-etching adhesives systems to cut enamel.Materials and Methods: One hundred ninety-five bovine teeth were used. The enamel on the buccal side was flattened with 600-grit SiC paper. For the control group, 15 teeth received Adper Single Bond 2, applied according to manufacturer's recommendations. The other specimens were divided into three groups according to the adhesive system used: Futura Bond M (FM; Voco), Clearfil S-3 Bond (CS; Kuraray), and Optibond All in One (OA; Kerr). For each group, two hydration states were tested: D: blown dry with air; W: the excess of water was removed with absorbent paper. Two application methods were tested: P (passive): the adhesive was simply left on the surface; A (active): the adhesive was rubbed with an applicator point. A coat of Grandio composite resin (Voco) was applied on the surface. The teeth were sectioned to obtain enamel-resin sticks (1 x 1 mm), which underwent microtensile bond testing. The data in MPa were submitted to a three-way ANOVA and Tukey's test (alpha = 5%).Results: The ANOVA showed significant differences for application method and the type of adhesive, but not for hydration state. For the application method, the results of Tukey's test were: P: 31.46 (+/-7.09)a; A: 34.04 (+/-7.19)b. For the type of adhesive, the results were: OA: 31.29 (+/-7.05)a; CS: 32.28 (+/-7.14)a; FM: 34.68 (+/-7.17)b; different lower-case letters indicate statistically significant differences.Conclusion: Active application improved the bond strength to cut enamel. The adhesive Futurabond M showed the highest bond strength to cut enamel.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An accurate estimate of machining time is very important for predicting delivery time, manufacturing costs, and also to help production process planning. Most commercial CAM software systems estimate the machining time in milling operations simply by dividing the entire tool path length by the programmed feed rate. This time estimate differs drastically from the real process time because the feed rate is not always constant due to machine and computer numerical controlled (CNC) limitations. This study presents a practical mechanistic method for milling time estimation when machining free-form geometries. The method considers a variable called machine response time (MRT) which characterizes the real CNC machine's capacity to move in high feed rates in free-form geometries. MRT is a global performance feature which can be obtained for any type of CNC machine configuration by carrying out a simple test. For validating the methodology, a workpiece was used to generate NC programs for five different types of CNC machines. A practical industrial case study was also carried out to validate the method. The results indicated that MRT, and consequently, the real machining time, depends on the CNC machine's potential: furthermore, the greater MRT, the larger the difference between predicted milling time and real milling time. The proposed method achieved an error range from 0.3% to 12% of the real machining time, whereas the CAM estimation achieved from 211% to 1244% error. The MRT-based process is also suggested as an instrument for helping in machine tool benchmarking.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Purpose: To evaluate the influence of the brush type as a earner of priming adhesive solutions and the use of paper points as a remover of the excess of these solutions on the push-out bond strength of resin cement to bovine root dentin. The null hypotheses were that brush type and the use of paper points do not affect the bond strength. Materials and Methods: The canals of 80 single-root bovine roots (16 mm in length) were prepared at 12 mm using the preparation drill (FRC Postec Plus, Ivoclar). Half of each root was embedded in acrylic resin and the specimens were divided into 8 groups, considering the factors brush type (4 levels) and paper point (2 levels) (n = 10): Gr 1: small microbrush (Cavi-Tip, SDI); Gr 2: Microbrush (Dentsply); Gr 3: Endobrush (Bisco); Gr 4: conventional brush (Bisco); Gr 5: Cavi-Tip (SDI) + paper points; Gr 6: Microbrush (Dentsply) + paper points; Gr 7: Endobrush (Bisco) + paper points; Gr 8: conventional brush (Bisco) + paper points. The root dentin was treated with a multistep total-etch adhesive system (All Bond 2). The adhesive system was applied using each microbrush, with and without using paper points. One fiber post was molded with addition silicon and 80 posts were made of resin cement (Duolink), The resin posts were luted (Duolink resin cement), and the specimens were stored for 24 h in water at 37°C. Each specimen was cut into 4 disk-shaped samples (1.8 mm in thickness), which were submitted to the push-out test. Results: The brush type (p < 0.0001) (small microbrush > microbrush = endobrush = conventional brush) and the use of paper points (p = 0.0001) (with > without) influenced the bond strength significantly (two-way ANOVA). The null hypotheses were rejected. Conclusion: The smallest brush (Cavi-Tip) and the use of paper points significantly improved the resin bond to bovine root dentin.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Marantaceae leaves have a contrasting color pattern and a decorative design which are interesting traits for its use as cut foliage. No postharvest research has been carried out on the potential as cut foliage for species of Ctenanthe, a member of the Marantaceae. Grey-maranta (Ctenathe setosa) is an herbaceous ornamental plant native of Brazil whose cut foliage has potential to be used as new crop product for local and international ornamental markets. The objective of this study was to evaluate pulse treatments to extend the longevity of foliage. The experiment was conducted in a complete randomized design with three replications and eight treatments: distilled water; pulsing cut petioles-ends in citric acid (pH = 2.8/1h); 2% sucrose (4h); 1% sucrose plus 200 mg L-1 citric acid (4h); 0.01% Tween® 20 (4h); 100 mg L -1 benzyladenine plus 0.01% Tween® 20 (4h); 100 mg L-1 gibberellic acid plus 0.01% Tween® 20 (4h); and maintenance of cut petiole in holding solution with commercial sodium hypochlorite (0.5 mL L-1). The senescence symptoms were mainly characterized by leaf rolling and by a decrease in the angle formed between leaf and petiole as a response to water deficit stress. Gibberellic acid or benzyladenine pulse treatments significantly extended longevity (6 days compared to control) and maintained leaves' green coloration and brightness for a longer time compared to control. However, only the benzyladenine plus Tween® 20 pulse maintained leaves in an erect form for a longer time, showing a significantly higher angle between leaf and petiole compared to control. Also, foliage pulsed with benzyladenine plus Tween® 20 showed a significant smallest loss of accumulated fresh mass percentage compared to control by the T test as to parallelism of treatments lines.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Lotus (Nelumbo nucifera Gaertn.) is a perennial herbaceous aquatic ornamental plant with potential to be used as a new cut flower for the Brazilian ornamental market. It shows exotic and attractive flowers and has a strong market appeal, once it is known as a symbol of purity, holiness and immortality. However, flowers have a short-vase life. Lotus flower stem exudes a large quantity of sticky milky sap from the cut surface, which is produced in laticifers, spatially associated with both xylem and phloem. It has been reported that latex coagulates on the cut surface preventing or reducing water absorption and reducing flowers' vaselife, requiring treatments to stop the flow of latex. The objective of this study was to report observations of lotus postharvest characteristics and evaluate treatments to overcome latex flow. The experiment was conducted as a complete randomized design with three replications of four stems in each vase and eight treatments; a control (distilled water), pretreatment of cut stem-ends with hot water (40° C/1 minute), boiling water (3 seconds), isopropyl alcohol 90% (10 minutes) or citric acid (pH = 2.8/1h) and, maintenance of stems in a holding solution of Tween® 20 (0.01%), citric acid (200 mg L-1) or Tween® 20 (0.01%) plus citric acid (200 mg L-1). Treatments had no significant effect on flowers vaselife which was only about three days, although isopropyl alcohol, hot and boiling water completely stopped latex flow. Cut stem-ends pretreated with citric acid (pH = 2.8/1 h) showed a significantly higher relative water content of petals compared to others treatments. The senescence symptom of lotus cut flowers was mainly characterized by abscission of turgid petals and dehiscence of stamens without any visual change of petal color and brightness.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fresh-cut fruit products, including carambola (Averrhoa carambola L.) have limited marketability due to cut surface browning attributed to oxidation of phenolic compounds by enzymes such as polyphenol oxidase (PPO). The objective of this study was to evaluate postharvest changes of carambola slices in three different packagings. Carambola fruit (cv. Fwang Tung) were picked from the orchard of Estação Experimental de Citricultura de Bebedouro at mature-green stage. Fruit were washed, dipped in NaOCl solution (200 mg.L -1 for 5 minutes), and stored overnight at 10°C. Fruit were manually sliced into pieces of approximately 1 cm. Slices were rinsed with NaOCl solution at 20 mg.L-1, drained for 3 minutes, and packaged in polyethylene terephthalate (PET) trays (Neoform N94); polystyrene trays covered with PVC 0.017 mm (Vitafilm - Goodyear); and vacuum sealed polyolefin bags (PLO, Cryovac PD900). The packages were stored at 6.8°C and 90%RH for 12 days and samples taken every 4 days. PET trays and PVC film did not significantly modify internal atmosphere and the high water permeability of PVC led to more rapid slice desiccation. PPO activity was lower when slices were packaged in PLO vacuum sealed bags, which reduced discolouration and led to better appearance maintenance for up to 12 days.