882 resultados para computer assisted instruction


Relevância:

80.00% 80.00%

Publicador:

Resumo:

STATEMENT OF PROBLEM: Wear of methacrylate artificial teeth resulting in vertical loss is a problem for both dentists and patients. PURPOSE: The purpose of this study was to quantify wear of artificial teeth in vivo and to relate it to subject and tooth variables. MATERIAL AND METHODS: Twenty-eight subjects treated with complete dentures received 2 artificial tooth materials (polymethyl methacrylate (PMMA)/double-cross linked PMMA fillers; 35%/59% (SR Antaris DCL, SR Postaris DCL); experimental 48%/46%). At baseline and after 12 months, impressions of the dentures were poured with improved stone. After laser scanning, the casts were superimposed and matched. Maximal vertical loss (mm) and volumetric loss (mm(3)) were calculated for each tooth and log-transformed to reduce variability. Volumetric loss was related to the occlusally active surface area. Linear mixed models were used to study the influence of the factors jaw, tooth, and material on adjusted (residual) wear values (alpha=.05). RESULTS: Due to drop outs (n=5) and unmatchable casts (n=3), 69% of all teeth were analyzed. Volumetric loss had a strong linear relationship to surface area (P<.001); this was less pronounced for vertical loss (P=.004). The factor showing the highest influence was the subject. Wear was tooth dependent (increasing from incisors to molars). However, these differences diminished once the wear rates were adjusted for occlusal area, and only a few remained significant (anterior versus posterior maxillary teeth). Another influencing factor was the age of the subject. CONCLUSIONS: Clinical wear of artificial teeth is higher than previously measured or expected. The presented method of analyzing wear of artificial teeth using a laser-scanning device seemed suitable.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Osteoporosis is a serious worldwide epidemic. FRAX® is a web-based tool developed by the Sheffield WHO Collaborating Center team, that integrates clinical risk factors and femoral neck BMD and calculates the 10 year fracture probability in order to help health care professionals identify patients who need treatment. However, only 31 countries have a FRAX® calculator. In the absence of a FRAX® model for a particular country, it has been suggested to use a surrogate country for which the epidemiology of osteoporosis most closely approximates the index country. More specific recommendations for clinicians in these countries are not available. In North America, concerns have also been raised regarding the assumptions used to construct the US ethnic specific FRAX® calculators with respect to the correction factors applied to derive fracture probabilities in Blacks, Asians and Hispanics in comparison to Whites. In addition, questions were raised about calculating fracture risk in other ethnic groups e.g., Native Americans and First Canadians. The International Society for Clinical Densitometry (ISCD) in conjunction with the International Osteoporosis Foundation (IOF) assembled an international panel of experts that ultimately developed joint Official Positions of the ISCD and IOF advising clinicians regarding FRAX® usage. As part of the process, the charge of the FRAX® International Task Force was to review and synthesize data regarding geographic and race/ethnic variability in hip fractures, non-hip osteoporotic fractures, and make recommendations about the use of FRAX® in ethnic groups and countries without a FRAX® calculator. This synthesis was presented to the expert panel and constitutes the data on which the subsequent Official Positions are predicated. A summary of the International Task Force composition and charge is presented here.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

To enhance the clinical value of coronary magnetic resonance angiography (MRA), high-relaxivity contrast agents have recently been used at 3T. Here we examine a uniform bilateral shadowing artifact observed along the coronary arteries in MRA images collected using such a contrast agent. Simulations were performed to characterize this artifact, including its origin, to determine how best to mitigate this effect, and to optimize a data acquisition/injection scheme. An intraluminal contrast agent concentration model was used to simulate various acquisition strategies with two profile orders for a slow-infusion of a high-relaxivity contrast agent. Filtering effects from temporally variable weighting in k-space are prominent when a centric, radial (CR) profile order is applied during contrast infusion, resulting in decreased signal enhancement and underestimation of vessel width, while both pre- and postinfusion steady-state acquisitions result in overestimation of the vessel width. Acquisition during the brief postinfusion steady-state produces the greatest signal enhancement and minimizes k-space filtering artifacts.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

AIM: To determine the long-term prognostic value of SPECT myocardial perfusion imaging (MPI) for the occurrence of cardiovascular events in diabetic patients. PATIENTS, METHODS: SPECT MPI of 210 consecutive Caucasian diabetic patients were analysed using Kaplan-Meier event-free survival curves and independent predictors were determined by Cox multivariate analyses. RESULTS: Follow-up was complete in 200 (95%) patients with a median period of 3.0 years (0.8-5.0). The population was composed of 114 (57%) men, age 65 +/- 10 years, 181 (90.5%) type 2 diabetes mellitus, 50 (25%) with a history of coronary artery disease (CAD) and 98 (49%) presenting chest pain prior to MPI. The prevalence of abnormal MPI was 58%. Patients with a normal MPI had neither cardiac death, nor myocardial infarction, independently of a history of coronary artery disease or chest pain. Among the independent predictors of cardiac death and myocardial infarction, the strongest was abnormal MPI (p < 0.0001), followed by history of CAD (Hazard Ratio (HR) = 15.9; p = 0.0001), diabetic retinopathy (HR = 10.0; p = 0.001) and inability to exercise (HR = 7.7; p = 0.02). Patients with normal MPI had a low revascularisation rate of 2.4% during the follow-up period. Compared to normal MPI, cardiovascular events increased 5.2 fold for reversible defects, 8.5 fold for fixed defects and 20.1 fold for the association of both defects. CONCLUSION: Diabetic patients with normal MPI had an excellent prognosis independently of history of CAD. On the opposite, an abnormal MPI led to a >5-fold increase in cardiovascular events. This emphasizes the value of SPECT MPI in predicting and risk-stratifying cardiovascular events in diabetic patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To test a method that allows automatic set-up of the ventilator controls at the onset of ventilation. DESIGN: Prospective randomized crossover study. SETTING: ICUs in one adult and one children's hospital in Switzerland. PATIENTS: Thirty intubated stable, critically ill patients (20 adults and 10 children). INTERVENTIONS: The patients were ventilated during two 20-min periods using a modified Hamilton AMADEUS ventilator. During the control period the ventilator settings were chosen immediately prior to the study. During the other period individual settings were automatically determined by the ventilatior (AutoInit). MEASUREMENTS AND RESULTS: Pressure, flow, and instantaneous CO2 concentration were measured at the airway opening. From these measurements, series dead space (V(DS)), expiratory time constant (RC), tidal volume (VT, total respiratory frequency (f(tot), minute ventilation (MV), and maximal and mean airway pressure (Paw, max and Paw, mean) were calculated. Arterial blood gases were analyzed at the end of each period. Paw, max was significantly less with the AutoInit ventilator settings while f(tot) was significantly greater (P < 0.05). The other values were not statistically significant. CONCLUSIONS: The AutoInit ventilator settings, which were automatically derived, were acceptable for all patients for a period of 20 min and were not found to be inferior to the control ventilator settings. This makes the AutoInit method potentially useful as an automatic start-up procedure for mechanical ventilation.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Computed tomography (CT) is used increasingly to measure liver volume in patients undergoing evaluation for transplantation or resection. This study is designed to determine a formula predicting total liver volume (TLV) based on body surface area (BSA) or body weight in Western adults. TLV was measured in 292 patients from four Western centers. Liver volumes were calculated from helical computed tomographic scans obtained for conditions unrelated to the hepatobiliary system. BSA was calculated based on height and weight. Each center used a different established method of three-dimensional volume reconstruction. Using regression analysis, measurements were compared, and formulas correlating BSA or body weight to TLV were established. A linear regression formula to estimate TLV based on BSA was obtained: TLV = -794.41 + 1,267.28 x BSA (square meters; r(2) = 0.46; P &lt;.0001). A formula based on patient weight also was derived: TLV = 191.80 + 18.51 x weight (kilograms; r(2) = 0.49; P &lt;.0001). The newly derived TLV formula based on BSA was compared with previously reported formulas. The application of a formula obtained from healthy Japanese individuals underestimated TLV. Two formulas derived from autopsy data for Western populations were similar to the newly derived BSA formula, with a slight overestimation of TLV. In conclusion, hepatic three-dimensional volume reconstruction based on helical CT predicts TLV based on BSA or body weight. The new formulas derived from this correlation should contribute to the estimation of TLV before liver transplantation or major hepatic resection.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: Surface magnetic resonance imaging (MRI) for aortic plaque assessment is limited by the trade-off between penetration depth and signal-to-noise ratio (SNR). For imaging the deep seated aorta, a combined surface and transesophageal MRI (TEMRI) technique was developed 1) to determine the individual contribution of TEMRI and surface coils to the combined signal, 2) to measure the signal improvement of a combined surface and TEMRI over surface MRI, and 3) to assess for reproducibility of plaque dimension analysis. METHODS AND RESULTS: In 24 patients six black blood proton-density/T2-weighted fast-spin echo images were obtained using three surface and one TEMRI coil for SNR measurements. Reproducibility of plaque dimensions (combined surface and TEMRI) was measured in 10 patients. TEMRI contributed 68% of the signal in the aortic arch and descending aorta, whereas the overall signal gain using the combined technique was up to 225%. Plaque volume measurements had an intraclass correlation coefficient of as high as 0.97. CONCLUSION: Plaque volume measurements for the quantification of aortic plaque size are highly reproducible for combined surface and TEMRI. The TEMRI coil contributes considerably to the aortic MR signal. The combined surface and TEMRI approach improves aortic signal significantly as compared to surface coils alone. CONDENSED ABSTRACT: Conventional MRI aortic plaque visualization is limited by the penetration depth of MRI surface coils and may lead to suboptimal image quality with insufficient reproducibility. By combining a transesophageal MRI (TEMRI) with surface MRI coils we enhanced local and overall image SNR for improved image quality and reproducibility.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present the case of a young man with compression of both renal arteries by the crura of the diaphragm. Correct diagnosis of renal artery entrapment is difficult but crucial. The investigations rely on an high index of suspicion and include Doppler ultrasound and spiral computed tomography angiography, which permits visualization of the diaphragm and its relationships with the aorta. This pathology, unlike common renal artery stenoses, requires surgical decompression and sometimes aortorenal bypass graft.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). METHODS: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. RESULTS: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations × 10 subsets and 2 iterations × 12 subsets. CONCLUSION: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Maintaining therapeutic concentrations of drugs with a narrow therapeutic window is a complex task. Several computer systems have been designed to help doctors determine optimum drug dosage. Significant improvements in health care could be achieved if computer advice improved health outcomes and could be implemented in routine practice in a cost effective fashion. This is an updated version of an earlier Cochrane systematic review, by Walton et al, published in 2001. OBJECTIVES: To assess whether computerised advice on drug dosage has beneficial effects on the process or outcome of health care. SEARCH STRATEGY: We searched the Cochrane Effective Practice and Organisation of Care Group specialized register (June 1996 to December 2006), MEDLINE (1966 to December 2006), EMBASE (1980 to December 2006), hand searched the journal Therapeutic Drug Monitoring (1979 to March 2007) and the Journal of the American Medical Informatics Association (1996 to March 2007) as well as reference lists from primary articles. SELECTION CRITERIA: Randomized controlled trials, controlled trials, controlled before and after studies and interrupted time series analyses of computerized advice on drug dosage were included. The participants were health professionals responsible for patient care. The outcomes were: any objectively measured change in the behaviour of the health care provider (such as changes in the dose of drug used); any change in the health of patients resulting from computerized advice (such as adverse reactions to drugs). DATA COLLECTION AND ANALYSIS: Two reviewers independently extracted data and assessed study quality. MAIN RESULTS: Twenty-six comparisons (23 articles) were included (as compared to fifteen comparisons in the original review) including a wide range of drugs in inpatient and outpatient settings. Interventions usually targeted doctors although some studies attempted to influence prescriptions by pharmacists and nurses. Although all studies used reliable outcome measures, their quality was generally low. Computerized advice for drug dosage gave significant benefits by:1.increasing the initial dose (standardised mean difference 1.12, 95% CI 0.33 to 1.92)2.increasing serum concentrations (standradised mean difference 1.12, 95% CI 0.43 to 1.82)3.reducing the time to therapeutic stabilisation (standardised mean difference -0.55, 95%CI -1.03 to -0.08)4.reducing the risk of toxic drug level (rate ratio 0.45, 95% CI 0.30 to 0.70)5.reducing the length of hospital stay (standardised mean difference -0.35, 95% CI -0.52 to -0.17). AUTHORS' CONCLUSIONS: This review suggests that computerized advice for drug dosage has some benefits: it increased the initial dose of drug, increased serum drug concentrations and led to a more rapid therapeutic control. It also reduced the risk of toxic drug levels and the length of time spent in the hospital. However, it had no effect on adverse reactions. In addition, there was no evidence to suggest that some decision support technical features (such as its integration into a computer physician order entry system) or aspects of organization of care (such as the setting) could optimise the effect of computerised advice.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Four standard radiation qualities (from RQA 3 to RQA 9) were used to compare the imaging performance of a computed radiography (CR) system (general purpose and high resolution phosphor plates of a Kodak CR 9000 system), a selenium-based direct flat panel detector (Kodak Direct View DR 9000), and a conventional screen-film system (Kodak T-MAT L/RA film with a 3M Trimax Regular screen of speed 400) in conventional radiography. Reference exposure levels were chosen according to the manufacturer's recommendations to be representative of clinical practice (exposure index of 1700 for digital systems and a film optical density of 1.4). With the exception of the RQA 3 beam quality, the exposure levels needed to produce a mean digital signal of 1700 were higher than those needed to obtain a mean film optical density of 1.4. In spite of intense developments in the field of digital detectors, screen-film systems are still very efficient detectors for most of the beam qualities used in radiology. An important outcome of this study is the behavior of the detective quantum efficiency of the digital radiography (DR) system as a function of beam energy. The practice of users to increase beam energy when switching from a screen-film system to a CR system, in order to improve the compromise between patient dose and image quality, might not be appropriate when switching from screen-film to selenium-based DR systems.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To reveal the EEG correlates of resting hypofrontality in schizophrenia (SZ). METHOD: We analyzed the whole-head EEG topography in 14 patients compared to 14 matched controls by applying a new parameterization of the multichannel EEG. We used a combination of power measures tuned for regional surface mapping with power measures that allow evaluation of global effects. RESULTS: The SZ-related EEG abnormalities include i) a global decrease in absolute EEG power robustly manifested in the alpha and beta frequency bands, and ii) a relative increase in the alpha power over the prefrontal brain regions against its reduction over the posterior regions. In the alpha band both effects are linked to the SZ symptoms measured with Positive and Negative Symptom Scales and to chronicity. CONCLUSION: As alpha activity is related to regional deactivation, our findings support the concept of hypofrontality in SZ and expose the alpha rhythm as a sensitive indicator of it.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The use of self-calibrating techniques in parallel magnetic resonance imaging eliminates the need for coil sensitivity calibration scans and avoids potential mismatches between calibration scans and subsequent accelerated acquisitions (e.g., as a result of patient motion). Most examples of self-calibrating Cartesian parallel imaging techniques have required the use of modified k-space trajectories that are densely sampled at the center and more sparsely sampled in the periphery. However, spiral and radial trajectories offer inherent self-calibrating characteristics because of their densely sampled center. At no additional cost in acquisition time and with no modification in scanning protocols, in vivo coil sensitivity maps may be extracted from the densely sampled central region of k-space. This work demonstrates the feasibility of self-calibrated spiral and radial parallel imaging using a previously described iterative non-Cartesian sensitivity encoding algorithm.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new method of measuring joint angle using a combination of accelerometers and gyroscopes is presented. The method proposes a minimal sensor configuration with one sensor module mounted on each segment. The model is based on estimating the acceleration of the joint center of rotation by placing a pair of virtual sensors on the adjacent segments at the center of rotation. In the proposed technique, joint angles are found without the need for integration, so absolute angles can be obtained which are free from any source of drift. The model considers anatomical aspects and is personalized for each subject prior to each measurement. The method was validated by measuring knee flexion-extension angles of eight subjects, walking at three different speeds, and comparing the results with a reference motion measurement system. The results are very close to those of the reference system presenting very small errors (rms = 1.3, mean = 0.2, SD = 1.1 deg) and excellent correlation coefficients (0.997). The algorithm is able to provide joint angles in real-time, and ready for use in gait analysis. Technically, the system is portable, easily mountable, and can be used for long term monitoring without hindrance to natural activities.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim of the present article was to perform three-dimensional (3D) single photon emission tomography-based dosimetry in radioimmunotherapy (RIT) with (90)Y-ibritumomab-tiuxetan. A custom MATLAB-based code was used to elaborate 3D images and to compare average 3D doses to lesions and to organs at risk (OARs) with those obtained with planar (2D) dosimetry. Our 3D dosimetry procedure was validated through preliminary phantom studies using a body phantom consisting of a lung insert and six spheres with various sizes. In phantom study, the accuracy of dose determination of our imaging protocol decreased when the object volume decreased below 5 mL, approximately. The poorest results were obtained for the 2.58 mL and 1.30 mL spheres where the dose error evaluated on corrected images with regard to the theoretical dose value was -12.97% and -18.69%, respectively. Our 3D dosimetry protocol was subsequently applied on four patients before RIT with (90)Y-ibritumomab-tiuxetan for a total of 5 lesions and 4 OARs (2 livers, 2 spleens). In patient study, without the implementation of volume recovery technique, tumor absorbed doses calculated with the voxel-based approach were systematically lower than those calculated with the planar protocol, with average underestimation of -39% (range from -13.1% to -62.7%). After volume recovery, dose differences reduce significantly, with average deviation of -14.2% (range from -38.7.4% to +3.4%, 1 overestimation, 4 underestimations). Organ dosimetry in one case overestimated, in the other underestimated the dose delivered to liver and spleen. However, both for 2D and 3D approach, absorbed doses to organs per unit administered activity are comparable with most recent literature findings.