500 resultados para carrel


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND The Perceval (Sorin Group, Milan, Italy) is a self-anchoring sutureless aortic valve prosthesis. We report the short- to midterm results of combined aortic valve replacement (AVR) with concomitant procedures in elderly patients undergoing operation as part of 3 consecutive prospective multicenter European studies. METHODS From April 2007 to February 2013, 243 patients (mean age, 79.7 ± 5.1 years; female patients, 61%; median EuroSCORE, 9%) underwent AVR with concomitant procedures. The concomitant procedures were coronary artery bypass grafting (CABG) (182 cases), septal myectomy (21 cases), CABG + other procedures (18 cases), and 22 other procedures. Primary and secondary end points included implant feasibility and safety (for mortality and morbidity) and efficacy (New York Heart Association [NYHA] class improvement and hemodynamic results) of the prosthesis at the different follow-up periods. Data were expressed as mean ± standard deviation. Kaplan-Meier analysis was performed for survival analysis. RESULTS Mean aortic cross-clamp and extracorporeal circulation (ECC) times were 50.7 ± 22.8 minutes and 78.9 ± 32.3 minutes, respectively. Thirty-day mortality was 2.1%. Mean postoperative gradient and effective orifice area were 10.1 ± 4.7 mm Hg and 1.5 ± 0.4 cm(2) and 8.9 ± 5.6 mm Hg and 1.6 ± 0.4 cm(2), respectively, at 1 year. There were early explantations, 4 of which resulted from paravalvular leaks. One additional valve explantation resulted from aortic root bleeding, probably caused by excessively extensive decalcification. In the late period, there was 1 mild paravalvular leak and no intravalvular insufficiency. No migration, dislodgement, or degeneration of the valve occurred during follow-up. Median follow-up was 444 days. CONCLUSIONS These trials confirm the safety and efficacy of the Perceval sutureless aortic valve, especially in elderly patients requiring AVR + concomitant procedures. In this patient group, sutureless valves may be advantageous compared to transcatheter valve implantations as concomitant procedures other than percutaneous coronary artery angioplasty are not always possible in the latter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES Fontan failure (FF) represents a growing and challenging indication for paediatric orthotopic heart transplantation (OHT). The aim of this study was to identify predictors of the best mid-term outcome in OHT after FF. METHODS Twenty-year multi-institutional retrospective analysis on OHT for FF. RESULTS Between 1991 and 2011, 61 patients, mean age 15.0 ± 9.7 years, underwent OHT for failing atriopulmonary connection (17 patients = 27.8%) or total cavopulmonary connection (44 patients = 72.2%). Modality of FF included arrhythmia (14.8%), complex obstructions in the Fontan circuit (16.4%), protein-losing enteropathy (PLE) (22.9%), impaired ventricular function (31.1%) or a combination of the above (14.8%). The mean time interval between Fontan completion and OHT was 10.7 ± 6.6 years. Early FF occurred in 18%, requiring OHT 0.8 ± 0.5 years after Fontan. The hospital mortality rate was 18.3%, mainly secondary to infection (36.4%) and graft failure (27.3%). The mean follow-up was 66.8 ± 54.2 months. The overall Kaplan-Meier survival estimate was 81.9 ± 1.8% at 1 year, 73 ± 2.7% at 5 years and 56.8 ± 4.3% at 10 years. The Kaplan-Meier 5-year survival estimate was 82.3 ± 5.9% in late FF and 32.7 ± 15.0% in early FF (P = 0.0007). Late FF with poor ventricular function exhibited a 91.5 ± 5.8% 5-year OHT survival. PLE was cured in 77.7% of hospital survivors, but the 5-year Kaplan-Meier survival estimate in PLE was 46.3 ± 14.4 vs 84.3 ± 5.5% in non-PLE (P = 0.0147). Cox proportional hazards identified early FF (P = 0.0005), complex Fontan pathway obstruction (P = 0.0043) and PLE (P = 0.0033) as independent predictors of 5-year mortality. CONCLUSIONS OHT is an excellent surgical option for late FF with impaired ventricular function. Protein dispersion improves with OHT, but PLE negatively affects the mid-term OHT outcome, mainly for early infective complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES To conduct a survey across European cardiac centres to evaluate the methods used for cerebral protection during aortic surgery involving the aortic arch. METHODS All European centres were contacted and surgeons were requested to fill out a short, comprehensive questionnaire on an internet-based platform. One-third of more than 400 contacted centres completed the survey correctly. RESULTS The most preferred site for arterial cannulation is the subclavian-axillary, both in acute and chronic presentation. The femoral artery is still frequently used in the acute condition, while the ascending aorta is a frequent second choice in the case of chronic presentation. Bilateral antegrade brain perfusion is chosen by the majority of centres (2/3 of cases), while retrograde perfusion or circulatory arrest is very seldom used and almost exclusively in acute clinical presentation. The same pumping system of the cardio pulmonary bypass is most of the time used for selective cerebral perfusion, and the perfusate temperature is usually maintained between 22 and 26°C. One-third of the centres use lower temperatures. Perfusate flow and pressure are fairly consistent among centres in the range of 10-15 ml/kg and 60 mmHg, respectively. In 60% of cases, barbiturates are added for cerebral protection, while visceral perfusion still receives little attention. Regarding cerebral monitoring, there is a general tendency to use near-infrared spectroscopy associated with bilateral radial pressure measurement. CONCLUSIONS These data represent a snapshot of the strategies used for cerebral protection during major aortic surgery in current practice, and may serve as a reference for standardization and refinement of different approaches.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE Sutureless valves are designed to facilitate surgical implantation, including less-invasive techniques in aortic valve replacement, by maintaining surgical precision of implantation compared with transcatheter techniques. Long-term clinical experience with sutureless valves is lacking. We report the 5-year follow-up results of an international, prospective, multicenter study evaluating the clinical performance and safety of the 3f Enable valve (Medtronic Inc, Minneapolis, Minn). METHODS Between March 2007 and December 2009, 141 patients (54 male; mean age, 76.1±5.7 years) undergoing aortic valve replacement with the 3f Enable valve were enrolled in 10 European sites. The mean follow-up was 2.76 years (range, 2 days to 5.1 years; total, 388.7 patient-years). Echocardiographic valvular hemodynamic and morphologic analyses were performed by an independent core laboratory. RESULTS The mean systolic gradient was 10.4±4.4 mm Hg at discharge and 7.7±4.1 mm Hg at 5 years. The mean effective orifice area was 1.7±0.5 cm2 at discharge and 1.6±0.2 cm2 at 5 years. Freedom from all-cause and valve-related mortality was 87.6%±2.9% and 96.8%±1.6% at 1 year (113 patients at risk) and 77.0%±7.5% and 93.8%±4.8% at 5 years (24 patients at risk), respectively. Six patients underwent reoperation (4 because of major paravalvular leakage and 2 because of endocarditis). Freedom from reoperation was 95.4%±1.9% at 1 year and 95.4%±6.1% at 5 years. No structural valve deterioration occurred during the follow-up period. CONCLUSIONS The sutureless 3f Enable valve represents a safe and effective treatment for aortic valve stenosis, providing an excellent hemodynamic profile. This study represents the longest follow-up study for a sutureless bioprosthesis. Sutureless valves may become an option for all patients with indicated biological aortic valve replacement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES The purpose of this study is to delineate changes in aortic geometry and diameter due to dissection. BACKGROUND Aortic diameter is the major criterion for elective ascending aortic replacement for dilated ascending aortas to prevent aortic dissection. However, recommendations are made on the basis of clinical experience and observation of diameters of previously dissected aortas. METHODS Six tertiary centers on 2 continents reviewed their acute aortic dissection type A databases, which contained 1,821 patients. Included were all non-Marfan patients with nonbicuspid aortic valves who had undergone computed tomography angiography <2 years before and within 12 h after aortic dissection onset. Aortic geometry before and after dissection onset were compared. RESULTS Altogether, 63 patients were included (27 spontaneous and 36 retrograde dissections, median age 68 [57; 77] years; 54% were men). In all but 1 patient, maximum ascending aortic diameter was <55 mm before aortic dissection onset. The largest increase in diameter and volume induced by the dissection were observed in the ascending aorta (40.1 [36.6; 45.3] mm vs. 52.9 [46.1; 58.6] mm, +12.8 mm; p < 0.001; 124.0 [90.8; 162.5] cm(3) vs. 171.0 [147.0; 197.0] cm(3), +47 cm(3); p < 0.001). Mean aortic arch diameter increased from 39.8 (30.5; 42.6) mm to 46.4 (42.0; 51.6) mm (+6.6 mm; p < 0.001) and descending thoracic aorta diameter from 31.2 (27.0; 33.3) mm to 34.9 (30.9; 39.5) mm (+3.7 mm; p < 0.001). Changes in thoracic aorta geometry were similar for spontaneous and retrograde etiology. CONCLUSIONS Geometry of the thoracic aorta is affected by aortic dissection, leading to an increase in diameter that is most pronounced in the ascending aorta. Both spontaneous and retrograde dissection result in similar aortic geometry changes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE A number of factors limit the effectiveness of current aortic arch studies in assessing optimal neuroprotection strategies, including insufficient patient numbers, heterogenous definitions of clinical variables, multiple technical strategies, inadequate reporting of surgical outcomes and a lack of collaborative effort. We have formed an international coalition of centres to provide more robust investigations into this topic. METHODS High-volume aortic arch centres were identified from the literature and contacted for recruitment. A Research Steering Committee of expert arch surgeons was convened to oversee the direction of the research. RESULTS The International Aortic Arch Surgery Study Group has been formed by 41 arch surgeons from 10 countries to better evaluate patient outcomes after aortic arch surgery. Several projects, including the establishment of a multi-institutional retrospective database, randomized controlled trials and a prospectively collected database, are currently underway. CONCLUSIONS Such a collaborative effort will herald a turning point in the surgical management of aortic arch pathologies and will provide better powered analyses to assess the impact of varying surgical techniques on mortality and morbidity, identify predictors for neurological and operative risk, formulate and validate risk predictor models and review long-term survival outcomes and quality-of-life after arch surgery.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES The number of heart transplantations is limited by donor organ availability. Donation after circulatory determination of death (DCDD) could significantly improve graft availability; however, organs undergo warm ischaemia followed by reperfusion, leading to tissue damage. Laboratory studies suggest that mechanical postconditioning [(MPC); brief, intermittent periods of ischaemia at the onset of reperfusion] can limit reperfusion injury; however, clinical translation has been disappointing. We hypothesized that MPC-induced cardioprotection depends on fatty acid levels at reperfusion. METHODS Experiments were performed with an isolated rat heart model of DCDD. Hearts of male Wistar rats (n = 42) underwent working-mode perfusion for 20 min (baseline), 27 min of global ischaemia and 60 min reperfusion with or without MPC (two cycles of 30 s reperfusion/30 s ischaemia) in the presence or absence of high fat [(HF); 1.2 mM palmitate]. Haemodynamic parameters, necrosis factors and oxygen consumption (O2C) were assessed. Recovery rate was calculated as the value at 60 min reperfusion expressed as a percentage of the mean baseline value. The Kruskal-Wallis test was used to provide an overview of differences between experimental groups, and pairwise comparisons were performed to compare specific time points of interest for parameters with significant overall results. RESULTS Percent recovery of left ventricular (LV) work [developed pressure (DP)-heart rate product] at 60 min reperfusion was higher in hearts reperfused without fat versus with fat (58 ± 8 vs 23 ± 26%, P < 0.01) in the absence of MPC. In the absence of fat, MPC did not affect post-ischaemic haemodynamic recovery. Among the hearts reperfused with HF, two significantly different subgroups emerged according to recovery of LV work: low recovery (LoR) and high recovery (HiR) subgroups. At 60 min reperfusion, recovery was increased with MPC versus no MPC for LV work (79 ± 6 vs 55 ± 7, respectively; P < 0.05) in HiR subgroups and for DP (40 ± 27 vs 4 ± 2%), dP/dtmax (37 ± 24 vs 5 ± 3%) and dP/dtmin (33 ± 21 vs 5 ± 4%; P < 0.01 for all) in LoR subgroups. CONCLUSIONS Effects of MPC depend on energy substrate availability; MPC increased recovery of LV work in the presence, but not in the absence, of HF. Controlled reperfusion may be useful for therapeutic strategies aimed at improving post-ischaemic recovery of cardiac DCDD grafts, and ultimately in increasing donor heart availability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives The aim of this study was to quantify potential differences in count, frequency and pattern of high-intensity transient signals (HITS) during transapical transcatheter aortic valve implantation (TA-TAVI), by comparing the Symetis Acurate TA (SA) with the balloon-expandable Edwards Sapien XT (ES) system. Background Recently, the Symetis Acurate TA revalving system has been introduced for TA-TAVI. The Symetis Acurate TA aortic bioprosthesis is self-expanding and is deployed by a specific two-step implantation technique. Whether this novel method increases the load of intraprocedural emboli, detected by transcranial Doppler ultrasound (TCD) as HITS, or not is not clear. Methods Twenty-two patients (n = 11 in each study arm, median logistic EuroScore 20%, median STS score 7%) displayed continuous TCD signals of good quality throughout the entire TA-TAVI procedure and were included in the final analysis. Data are presented as median with interquartile ranges. Results No significant differences were detected in total procedural or interval-related HITS load (SA: 303 [200; 594], ES: 499 [285; 941]; p = 0.16). With both devices, HITS peaked during prosthesis deployment (PD), whereas significantly fewer HITS occurred during instrumentation (SA: p = 0.002; ES: <0.001) or post-implantation PI (SA: p = 0.007; ES: <0.001). PD-associated HITS amounted to almost half of the total HITS load. One patient suffered new disabling stroke at 30 days. Thirty-day mortality amounted to 13.6% (3 of 22 patients). Conclusions Simplified transapical delivery using the self-expanding SA device does not increase HITS, despite of a two-step deployment technique with more interactions with the native aortic valve, when compared to the balloon-expandable ES valve. The similarity in HITS count, frequency and pattern with the two systems suggests a common mechanism for the release of cerebral microemboli.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Numerous designs of bioprosthetic valves exist. The sutureless surgical valve is a newer design concept which combines elements of the transcatheter valve technology with surgical valves. This design aims at shorter and easier implantation. It was the aim of this study to perform hemodynamic and kinematic measurements for this type of valves to serve as a baseline for following studies which investigate the effect of the aortic root on the valve performance. To this end, the Edwards Intuity aortic valve was investigated in a new in vitro flow loop mimicking the left heart. The valve was implanted in a transparent, compliant aortic root model, and the valve kinematics was investigated using a high speed camera together with synchronized hemodynamic measurements of pressures and flows. The valve closure was asynchronous (one by one leaflet), and the valve started to close before the deceleration of the fluid. The aortic root model showed a dilation of the sinuses which was different to the ascending aorta, and the annulus was found to move towards the left ventricle during diastole and towards the aorta during systole.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: Minimizing resection and preserving leaflet tissue has been previously shown to be beneficial for mitral valve function and leaflet kinematics after repair of acute posterior leaflet prolapse in porcine valves. We examined the effects of different additional methods of mitral valve repair (neochordoplasty, ring annuloplasty, edge-to-edge repair and triangular resection) on hemodynamics at different heart rates in an experimental model. Methods: Severe acute P2 prolapse was created in eight porcine mitral valves by resecting the posterior marginal chordae. Valve hemodynamics was quantified under pulsatile conditions in an in vitro heart simulator before and after surgical manipulation. Mitral regurgitation was corrected using four different methods of repair on the same valve: neochordoplasty with expanded polytetrafluoroethylene sutures alone and together with ring annuloplasty, edge-to-edge repair and triangular resection, both with non-restrictive annuloplasty. Residual mitral valve leak, trans-valvular pressure gradients, flow and cardiac output were measured at 60 and 80 beats/min. A validated statistical linear mixed model was used to analyze the effect of treatment. The p values were calculated using a two-sided Wald test. Results: Only neochordoplasty with expanded polytetrafluoroethylene sutures but without ring annuloplasty achieved similar hemodynamics compared to those of the native mitral valve (p range 0.071-0.901). Trans-valvular diastolic pressure gradients were within a physiologic range but significantly higher than those of the native valve following neochordoplasty with ring annuloplasty (p=0.000), triangular resection (p=0.000) and edge-to-edge repair (p=0.000). Neochordoplasty alone was significantly better in terms of hemodynamic than neochordoplasty with a ring annuloplasty (p=0.000). These values were stable regardless of heart rate or ring size. Conclusions: Neochordoplasty without ring annuloplasty is the only repair technique able to achieve almost native physiological hemodynamics after correction of leaflet prolapse in a porcine experimental model of acute chordal rupture.