828 resultados para bioassay screening


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coeliac disease (CD) is associated with a wide spectrum of clinical presentation and may be overlooked as a diagnosis. There is some evidence that untreated CD is associated with a doubling of mortality, largely due to an increase in the incidence of malignancy and small intestinal lymphoma, which is decreased by a strict gluten-free diet. We studied the clinical features of screening-detected coeliacs compared to age- and sex-matched controls as a 3-year follow-up to a population screening survey, and followed-up subjects who had had CD-associated serology 11 years previously to determine whether they have CD or an increased mortality rate compared to the general population. Samples of the general population (MONICA 1991 and 1983) were screened for CD-associated serology and followed-up after 3 and 11 years, respectively, and assessed by a clinical questionnaire, screening blood tests and jejunal biopsy. Mortality rates for 'all deaths' and 'cancer deaths' were compared in subjects with positive serology in 1983 with reference to the general population. Thirteen coeliacs were diagnosed by villous atrophy following screening, compared to two patients with clinically detected CD, giving a prevalence of 1:122. Clinical features or laboratory parameters were not indicative of CD compared to controls. Subjects with positive serology followed up after 11 years did not have an excess mortality for either cancer deaths or all causes of death. Screening-detected CD is rarely silent and may be associated with significant symptoms and morbidity. In this limited study with small numbers, there does not appear to be an increased mortality from screening-detected CD, although the follow-up may be too short to detect any difference.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To design a new, highly sensitive psychometric screening to identify patients with mild cognitive impairment (MCI) and patients with dementia in the early stages of the disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ecotoxicological screening of dust sampled throughout a Kenyan tannery was conducted using a luminescence (lux)-based bacterial biosensor for both solid and liquid assays. This was complemented by chemical analysis in an attempt to identify possible causative toxic components. The biosensor results showed a highly significant (p <0.001) difference in both solid and liquid phase toxicity in samples collected from various identified sampling points in the tannery. A positive correlation was observed between results of the solid and liquid phase techniques, for most of the sampling points indicating that the toxic contaminants were bioavailable both in the solid and liquid state. However, the results generally indicated toxicity associated with liquid phase except certain areas in solid phase such as chemical handling, buffing area and weighing. The most toxic tannery area identified was the weighing area (p <0.001), showing the lowest bioluminescence for both the solid (0.38 +/- 2.21) and liquid phases (0.01 +/- 0.001). Chromium was the metal present in the highest concentration indicating levels higher than the stipulated regulatory requirement of 0.5 mg Cr/m3 for total Cr (highest Cr concentration was at chemical handling at 209.24 mg l(-1)) in all dust samples. The weighing area had the highest Ni concentration (1.87 mg l(-1)) and the chemical handling area showed the highest Zn concentration (31.9 mg l(-1)). These results raise environmental health concerns, as occupational exposure to dust samples from this site has been shown to give rise to elevated concentrations (above the stipulated levels) of chromium in blood, urine and some body tissues, with inhalation being the main route. Health and Safety Executive (HSE), UK, and American Conference of Governmental Industrial Hygienist (ACGIH) and National Institute for Occupational Safety and Health (NIOSH), USA stipulates an occupational exposure limit of 0.5 mg Cr/m3 (8 h TWA) for total chromium. However, schedule 1 of Controls of substances hazardous to health (COSHH) regulations developed by HSE, indicate 0.05 mg m3 (8 h TWA reference periods) to be the limit for Cr (VI) exposure. The exposure limit for individual (e.g., Cr, Zn, Ni etc.) contaminants (homogeneity) was not exceeded, but potential impact of heterogeneity (multi-element synergistic effect) on toxicity requires application of the precautionary principle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A bacterial bioassay, suitable for rapid screening to assess the relative toxicity of xenobiotic contaminated groundwater has been developed. The quantitative bioassay utilizes a decline in luminescence of the lux marked soil bacterium Pseudomonas fluorescens on exposure to contaminated groundwaters from which effective concentration (EC) values can be assessed and compared. P. fluorescens was most sensitive to semi-volatile organics in groundwaters but there was no correlation between EC value and chemical content. The sensitivity and reproducibility of the P. fluorescens bioassay was compared with that of Microtox and results showed that mean EC50 values for diluted ground water replicate samples were 20% and 18% respectively. This suggested that the P. fluorescens bioassay was as applicable to groundwater screening as the widely used Microtox bioassay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to compare time-domain waveform analysis of second-trimester uterine artery Doppler using the resistance index (RI) with waveform analysis using a mathematical tool known as wavelet transform for the prediction of pre-eclampsia (PE). This was a retrospective, nested case-cohort study of 336 women, 37 of whom subsequently developed PE. Uterine artery Doppler waveforms were analysed using both RI and waveform analysis. The utility of these indices in screening for PE was then evaluated using receiver operating characteristic curves. There were significant differences in uterine artery RI between the PE women and those with normal pregnancy outcome. After wavelet analysis, significant difference in the mean amplitude in wavelet frequency band 4 was noted between the 2 groups. The sensitivity for both Doppler RI and frequency band 4 for the detection of PE at a 10% false-positive rate was 45%. This small study demonstrates the application of wavelet transform analysis of uterine artery Doppler waveforms in screening for PE. Further prospective studies are needed in order to clearly define if this analytical approach to waveform analysis may have the potential to improve the detection of PE by uterine artery Doppler screening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the comparative accuracy of potential screening tests for open angle glaucoma (OAG).

METHODS: Medline, Embase, Biosis (to November 2005), Science Citation Index (to December 2005), and The Cochrane Library (Issue 4, 2005) were searched. Studies assessing candidate screening tests for detecting OAG in persons older than 40 years that reported true and false positives and negatives were included. Meta-analysis was undertaken using the hierarchical summary receiver operating characteristic model.

RESULTS: Forty studies enrolling over 48,000 people reported nine tests. Most tests were reported by only a few studies. Frequency-doubling technology (FDT; C-20-1) was significantly more sensitive than ophthalmoscopy (30, 95% credible interval [CrI] 0-62) and Goldmann applanation tonometry (GAT; 45, 95% CrI 17-68), whereas threshold standard automated perimetry (SAP) and Heidelberg Retinal Tomograph (HRT II) were both more sensitive than GAT (41, 95% CrI 14-64 and 39, 95% CrI 3-64, respectively). GAT was more specific than both FDT C-20-5 (19, 95% CrI 0-53) and threshold SAP (14, 95% CrI 1-37). Judging performance by diagnostic odds ratio, FDT, oculokinetic perimetry, and HRT II are promising tests. Ophthalmoscopy, SAP, retinal photography, and GAT had relatively poor performance as single tests. These findings are based on heterogeneous data of limited quality and as such are associated with considerable uncertainty.

CONCLUSIONS: No test or group of tests was clearly superior for glaucoma screening. Further research is needed to evaluate the comparative accuracy of the most promising tests.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Familial hypercholesterolemia (FH) is a common single gene disorder, which predisposes to coronary artery disease. In a previous study, we have shown that in patients with definite FH around 20% had no identifiable gene defect after screening the entire exon coding area of the low density lipoprotein receptor (LDLR) and testing for the common Apolipoprotein B (ApoB) R3500Q mutation. In this study, we have extended the screen to additional families and have included the non-coding intron splice regions of the gene. In families with definite FH (tendon xanthoma present, n = 68) the improved genetic screening protocol increased the detection rate of mutations to 87%. This high detection rate greatly enhances the potential value of this test as part of a clinical screening program for FH. In contrast, the use of a limited screen in patients with possible FH (n = 130) resulted in a detection rate of 26%, but this is still of significant benefit in diagnosis of this genetic condition. We have also shown that 14% of LDLR defects are due to splice site mutations and that the most frequent splice mutation in our series (c.1845 + 11 c > g) is expressed at the RNA level. In addition, DNA samples from the patients in whom no LDLR or ApoB gene mutations were found, were sequenced for the NARC-1 gene. No mutations were identified which suggests that the role of NARC-1 in causing FH is minor. In a small proportion of families (