846 resultados para barium ferrite


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Enrofloxacin (ENR) is an antimicrobial used both in humans and in food producing species. Its control is required in farmed species and their surroundings in order to reduce the prevalence of antibiotic resistant bacteria. Thus, a new biomimetic sensor enrofloxacin is presented. An artificial host was imprinted in specific polymers. These were dispersed in 2-nitrophenyloctyl ether and entrapped in a poly(vinyl chloride) matrix. The potentiometric sensors exhibited a near-Nernstian response. Slopes expressing mV/Δlog([ENR]/M) varied within 48–63. The detection limits ranged from 0.28 to 1.01 µg mL−1. Sensors were independent from the pH of test solutions within 4–7. Good selectivity was observed toward potassium, calcium, barium, magnesium, glycine, ascorbic acid, creatinine, norfloxacin, ciprofloxacin, and tetracycline. In flowing media, the biomimetic sensors presented good reproducibility (RSD of ± 0.7%), fast response, good sensitivity (47 mV/Δlog([ENR]/M), wide linear range (1.0 × 10−5–1.0 × 10−3 M), low detection limit (0.9 µg mL−1), and a stable baseline for a 5 × 10−2 M acetate buffer (pH 4.7) carrier. The sensors were used to analyze fish samples. The method offered the advantages of simplicity, accuracy, and automation feasibility. The sensing membrane may contribute to the development of small devices allowing in vivo measurements of enrofloxacin or parent-drugs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nexplanon (Schering-Plough Limited/Merck Sharp & Dohme Limited (MSD)) is a long active reversible contraceptive method that provides effective contraception for 3 years. It consists of a single, flexible, rod-shaped implant, containing 68 mg etonogestrel. It is 4 cm long, consists of an ethylene vinyl acetate copolymer, a non-absorbable material, and also contains 15 mg of barium sulfate, which makes it visible by X-ray. We describe a case of a 39-year-old woman who experienced a local reaction to the barium sulfate in Nexplanon. She was given medical treatment, but only the removal of the implant resolved the symptoms. After removal there was gradual improvement and 72 h later the patient was asymptomatic. Allergic reaction to barium sulfate is extremely rare: until now, there have only been two cases associated with Nexplanon described in the literature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A radiological study of the small intestine of 17 untreated patients in the acute phase ofschistosomiasis was performed. Twelve patients (70% of total) had alterations: nine had clear-cut thickening of the duodenal and jejunal folds, one flocculation, one fragmentation and one thickening of mucosae, flocculation and fragmentation of the barium column. There was no correlation of the gastrointestinal symptomatology (vomiting, diarrhoea, dysentery, hepatomegaly) neither with the parasitological load nor with the x-ray alterations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

3rd Historic Mortars Conference, 11-14 September 2013, Glasgow, Scotland

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalhos recentes têm demonstrado que a medição de perfis de condutividade eléctrica é uma técnica eficaz, rápida e não destrutiva para a caracterização de materiais metálicos ligados por soldadura por fusão ou no estado sólido. Os resultados referentes às ligas de alumínio mostram que existe uma estreita correlação entre os perfis de condutividade eléctrica e os perfis de dureza, sendo os primeiros determinados sobretudo pelo tamanho de grão. Relativamente às ligas de aço, verifica-se que os perfis de condutividade eléctrica também permitem identificar as diferentes zonas termicamente afectadas devido aos processos de soldadura por fusão, as quais são geralmente descritas por zona fundida (ZF) e zona termicamente afectada (ZTA), sendo a sua extensão dependente sobretudo da Entrega Térmica (ET). Contudo, em algumas ligas, as características metalúrgicas que controlam as variações de condutividade eléctrica não estão devidamente descritas ou compreendidas. Nesse sentido, o objectivo do presente trabalho foi caracterizar os perfis de condutividade eléctrica em diferentes ligas de aço soldadas por fusão, identificando os principais aspectos metalúrgicos que lhes estão subjacentes. Foram realizados cordões de soldadura SER e TIG de aços P11, P22 e não ligado com diferentes parâmetros de soldadura. Os perfis de condutividade eléctrica foram medidos com sondas de correntes induzidas e com sondas de quatro pontos a diferentes profundidades, tendo sido comparados com os respectivos perfis de microdureza Vickers. Os resultados mostram que existe uma boa correlação entre a condutividade e a dureza, sendo que a condutividade é essencialmente determinada pelo tamanho de grão, e pela morfologia da fase ferrítica. A ferrite Witmanstatten facilita a passagem de corrente eléctrica ao contrário da ferrite poligonal que constitui um obstáculo à passagem de electrões. Pode confirmar-se que a medição dos perfis de condutividade é uma técnica com elevado potencial para complementar, ou em alguns casos substituir, a medição de durezas em ligas de aço soldadas por fusão.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The manipulation of electric ordering with applied magnetic fields has been realized on magnetoelectric (ME) materials, however, their ME switching is often accompanied by significant hysteresis and coercivity that represents, for some applications, a severe weakness. To overcome this obstacle, this work focus on the development of a new type of ME polymer nanocomposites that exhibits tailored ME response at room temperature. The multiferroic nanocomposites are based on three different ferrite nanoparticles, Zn0.2Mn0.8Fe2O4 (ZMFO), CoFe2O4 (CFO) and Fe3O4 (FO), dispersed in a piezoelectric co-polymer poly(vinylindene fluoride-trifluoroethylene), P(VDF-TrFE), matrix. No substantial differences were detected on the time-stable piezoelectric response of the composites (≈ -28 pC.N−1) with distinct ferrite fillers and for the same ferrite content of 10wt.%. Magnetic hysteresis loops from pure ferrite nanopowders showed different magnetic responses. ME results of the nanocomposite films with 10wt.% ferrite content revealed that the ME induced voltage increases with increasing DC magnetic field until a maximum of 6.5 mV∙cm−1∙Oe−1, at an optimum magnetic field of 0.26 T, and 0.8 mV∙cm−1∙Oe−1, at an optimum magnetic field of 0.15T, for the CFO/P(VDF-TrFE) and FO/P(VDF-TrFE) composites, respectively. On the contrary, the ME response of the ZMFO/P(VDF-TrFE) exposed no hysteresis and high dependence on the ZMFO filler content. Possible innovative applications such as memories and information storage, signal processing, ME sensors and oscillators have been addressed for such ferrite/PVDF nanocomposites.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Preprint submitted to International Journal of Solids and Structures. ISSN 0020-7683

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The study was performed at OCAS, the Steel Research Centre of ArcelorMittal for the Industry market. The major aim of this research was to obtain an optimized tensile testing methodology with in-situ H-charging to reveal the hydrogen embrittlement in various high strength steels. The second aim of this study has been the mechanical characterization of the hydrogen effect on hight strength carbon steels with varying microstructure, i.e. ferrite-martensite and ferrite-bainite grades. The optimal parameters for H-charging - which influence the tensile test results (sample geometry type of electrolyte, charging methods effect of steel type, etc.) - were defined and applied to Slow Strain Rate testing, Incremental Step Loading and Constant Load Testing. To better understand the initiation and propagation of cracks during tensile testing with in-situ H-charging, and to make the correlation with crystallographic orientation, some materials have been analyzed in the SEM in combination with the EBSD technique. The introduction of a notch on the tensile samples permits to reach a significantly improved reproducibility of the results. Comparing the various steel grades reveals that Dual Phase (ferrite-martensite) steels are more sensitive to hydrogen induced cracking than the FB (ferritic-bainitic) ones. This higher sensitivity to hydrogen was found back in the reduced failure times, increased creep rates and enhanced crack initiation (SEM) for the Dual Phase steels in comparison with the FB steels.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In Mexico, despite the relatively high seroprevalence of Trypanosoma cruzi infection in humans in some areas, reported morbidity of Chagas disease is not clear. We determined clinical stage in 71 individuals seropositive to T. cruzi in the state of Puebla, Mexico, an area endemic for Chagas disease with a reported seroprevalence of 7.7%. Diagnosis of Chagas disease was made by two standardized serological tests (ELISA, IHA). Individuals were stratified according to clinical studies. All patients were submitted to EKG, barium swallow, and barium enema. Groups were identified as indeterminate form (IF) asymptomatic individuals without evidence of abnormalities (n = 34 cases); those with gastrointestinal alterations (12 patients) including symptoms of abnormal relaxation of the lower esophageal sphincter and absent peristalsis in the esophageal body, grade I megaesophagus, and/or megacolon; patients with clinical manifestations and documented changes of chronic Chagas heart disease who were subdivided as follows: mild (8 patients) - mild electrocardiographic changes of ventricular repolarization, sinus bradychardia); moderate (6 patients) - left bundle branch block, right bundle branch block associated with left anterior fascicular block); severe (8 patients) - signs of cardiomegaly, dilated cardiomyopathy); and the associated form (3 cases) that included presence of both cardiomyopathy and megaesophagus. These data highlight the importance of accurate evaluation of the prevalence and clinical course of Chagas disease in endemic and non-endemic areas of Mexico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aquesta tesi explora la possibilitat de fer servir enllaços inductius per a una aplicació de l’automòbil on el cablejat entre la centraleta (ECU) i els sensors o detectors és difícil o impossible. S’han proposat dos mètodes: 1) el monitoratge de sensors commutats (dos possibles estats) via acoblament inductiu i 2) la transmissió mitjançant el mateix principi físic de la potència necessària per alimentar els sensors autònoms remots. La detecció d'ocupació i del cinturó de seguretat per a seients desmuntables pot ser implementada amb sistemes sense fils passius basats en circuits ressonants de tipus LC on l'estat dels sensors determina el valor del condensador i, per tant, la freqüència de ressonància. Els canvis en la freqüència són detectats per una bobina situada en el terra del vehicle. S’ha conseguit provar el sistema en un marge entre 0.5 cm i 3 cm. Els experiments s’han dut a terme fent servir un analitzador d’impedàncies connectat a una bobina primària i sensors comercials connectats a un circuit remot. La segona proposta consisteix en transmetre remotament la potència des d’una bobina situada en el terra del vehicle cap a un dispositiu autònom situat en el seient. Aquest dispositiu monitorarà l'estat dels detectors (d'ocupació i de cinturó) i transmetrà les dades mitjançant un transceptor comercial de radiofreqüència o pel mateix enllaç inductiu. S’han avaluat les bobines necessàries per a una freqüència de treball inferior a 150 kHz i s’ha estudiat quin és el regulador de tensió més apropiat per tal d’aconseguir una eficiència global màxima. Quatre tipus de reguladors de tensió s’han analitzat i comparat des del punt de vista de l’eficiència de potència. Els reguladors de tensió de tipus lineal shunt proporcionen una eficiència de potència millor que les altres alternatives, els lineals sèrie i els commutats buck o boost. Les eficiències aconseguides han estat al voltant del 40%, 25% i 10% per les bobines a distàncies 1cm, 1.5cm, i 2cm. Les proves experimentals han mostrat que els sensors autònoms han estat correctament alimentats fins a distàncies de 2.5cm.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CD is a chronic inflammatory disorder associated to mucosal and transmural inflammation of the bowel wall. It is well known that CD can affect the entire gastrointestinal. Therefore, ileocolonoscopy and biopsies of the terminal ileum as well as of each colonic segment to look for microscopic evidence of CD are the first-line procedures to establish the diagnosis. However, it has been observed that up to 30% of the patients have only small bowel involvement. Evaluation of the small bowel has been made with radiological procedures, barium radiography, and abdominal computed tomography or by ileocolonoscopy or enteroscopy, but they have many recognized limitations. CE is undoubtedly a very useful diagnostic tool proposed to observe small-bowel lesions undetectable by conventional endoscopy or radiologic studies. We review different studies that have been published reporting the use of CE in suspected and evaluation of the extension or the recurrence in CD and also its use in pediatric population and its complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CD is a chronic inflammatory disorder associated to mucosal and transmural inflammation of the bowel wall. It is well known that CD can affect the entire gastrointestinal. Therefore, ileocolonoscopy and biopsies of the terminal ileum as well as of each colonic segment to look for microscopic evidence of CD are the first-line procedures to establish the diagnosis. However, it has been observed that up to 30% of the patients have only small bowel involvement. Evaluation of the small bowel has been made with radiological procedures, barium radiography, and abdominal computed tomography or by ileocolonoscopy or enteroscopy, but they have many recognized limitations. CE is undoubtedly a very useful diagnostic tool proposed to observe small-bowel lesions undetectable by conventional endoscopy or radiologic studies. We review different studies that have been published reporting the use of CE in suspected and evaluation of the extension or the recurrence in CD and also its use in pediatric population and its complications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aquest projecte, que col•labora amb el Grup de Recerca en Materials i termodinàmica,tractarà de com obtenir òxids de bari purs per incloure en la matriu del superconductorYBCO a partir de diversos precursors moleculars tals com l’acetat de bari, el propionatde bari i l’etil hexaonat de bari. La dificultat rau en la descomposició tèrmica d’aquestsprecursors a òxid, ja que solen descompondre’s a carbonat. L’estudi consistirà encercar les condicions que evitin la formació de carbonat i per tant afavoreixin l’obtencióde l’òxid.L’estudi es realitza fent ús de les tècniques d’anàlisi tèrmica tals com latermogravimetria i l’anàlisi tèrmica diferencial. A posteriori, també hem utilitzat ladifracció de Raigs-X que ens permetrà analitzar el residu sòlid resultat de ladescomposició i per tant saber quin compost tenim, si òxid o carbonat. Tot i això, caltenir en compte que aquesta tècnica s’ha d’aplicar en finalitzar l’anàlisi tèrmica ja quesinó l’òxid que es forma reacciona amb el CO2 de l’atmosfera amb molta facilitat ialeshores s’observa només carbonat en el resultat

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Astrocytes are responsible for regulating extracellular levels of glutamate and potassium during neuronal activity. Glutamate clearance is handled by glutamate transporter subtypes glutamate transporter 1 and glutamate-aspartate transporter in astrocytes. DL-threo-beta-benzyloxyaspartate (TBOA) and dihydrokainate (DHK) are extensively used as inhibitors of glial glutamate transport activity. Using whole-cell recordings, we characterized the effects of both transporter inhibitors on afferent-evoked astrocyte currents in acute cortical slices of 3-week-old rats. When neuronal afferents were stimulated, passive astrocytes responded by a rapid inward current followed by a persistent tail current. The first current corresponded to a glutamate transporter current. This current was inhibited by both inhibitors and by tetrodotoxin. The tail current is an inward potassium current as it was blocked by barium. Besides inhibiting transporter currents, TBOA strongly enhanced the tail current. This effect was barium-sensitive and might be due to a rise in extracellular potassium level and increased glial potassium uptake. Unlike TBOA, DHK did not enhance the tail current but rather inhibited it. This result suggests that, in addition to inhibiting glutamate transport, DHK prevents astrocyte potassium uptake, possibly by blockade of inward-rectifier channels. This study revealed that, in brain slices, glutamate transporter inhibitors exert complex effects that cannot be attributed solely to glutamate transport inhibition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The cortical collecting duct (CCD) plays a key role in regulated K(+) secretion, which is mediated mainly through renal outer medullary K(+) (ROMK) channels located in the apical membrane. However, the mechanisms of the regulation of urinary K(+) excretion with regard to K(+) balance are not well known. We took advantage of a recently established mouse CCD cell line (mCCD(cl1)) to investigate the regulation of K(+) secretion by mineralocorticoid and K(+) concentration. We show that this cell line expresses ROMK mRNA and a barium-sensitive K(+) conductance in its apical membrane. As this conductance is sensitive to tertiapin-Q, with an apparent affinity of 6 nM, and to intracellular acidification, it is probably mediated by ROMK. Overnight exposure to 100 nM aldosterone did not significantly change the K(+) conductance, while it increased the amiloride-sensitive Na(+) transport. Overnight exposure to a high K(+) (7 mM) concentration produced a small but significant increase in the apical membrane barium-sensitive K(+) conductance. The mRNA levels of all ROMK isoforms measured by qRT-PCR were not changed by altering the basolateral K(+) concentration but were decreased by 15-45% upon treatment with aldosterone (0.3 or 300 nM for 1 and 3 h). The paradoxical response of ROMK expression to aldosterone could possibly work as a preventative mechanism to avoid excessive K(+) loss which would otherwise result from the increased electrogenic Na(+) transport and associated depolarization of the apical membrane in the CCD. In conclusion, mCCD(cl1) cells demonstrate a significant K(+) secretion, probably mediated by ROMK, which is not stimulated by aldosterone but increased by overnight exposure to a high K(+) concentration.