Resumo:


Background: A core component of nurse education is clinical practice in order to support the development of clinical skills and competence. Assessment and measurement of the clinical competence of nursing students is important to gauge their professional development and educational needs.

Aim: To evaluate the impact of an Older Persons’ Assessment Educational Workbook (OPAEW) and explore second year nursing students’ competence and their opinions and use of the workbook.

Methods: A ‘before and after’ pre-experimental design was undertaken with n=6 second year nursing students. Outcome measures were the Nursing Competencies Questionnaire and the Self-efficacy in Clinical Performance Scale. Content analysis of workbooks and a survey (n=5) of opinions regarding the workbook was undertaken.

Findings: Pre and post test results for the study (n=5) were tested to determine if there was a relationship between changes in the NCQ and SECP repeated measures and use of an OPAEW. Testing identified evidence of a statistically significant difference for both SECP measures (SECP28 p=0.043; SECP7 p=0.042), with no clear statistical evidence of a difference for the NCQ (p=0.08). A weak negative association (NCQ ρ=-0.600 p=0.285; SECP28 ρ=-0.300 p=0.624; SECP7 ρ=-0.205 p=0.741), was found indicating that those participants who scored the lowest scores at the start of the study, benefited most from the workbook.

Content analysis of the OPAEW (n=5) found that 3 of the 5 participants completed all components of the workbook, with a mean of 1051 words used (SD 281.8). Through the survey (n=5) students reported the workbook as a useful guide when undertaking a patient assessment.

Conclusions: The OPAEW showed potential as an intervention to support the development of nursing students’ competence in older person assessment skills.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Currently, no standard mix design procedure is available for CIR-emulsion in Iowa. The CIR-foam mix design process developed during the previous phase is applied for CIR-emulsion mixtures with varying emulsified asphalt contents. Dynamic modulus test, dynamic creep test, static creep test and raveling test were conducted to evaluate the short- and long-term performance of CIR-emulsion mixtures at various testing temperatures and loading conditions. A potential benefit of this research is a better understanding of CIR-emulsion material properties in comparison with those of CIR-foam material that would allow for the selection of the most appropriate CIR technology and the type and amount of the optimum stabilization material. Dynamic modulus, flow number and flow time of CIR-emulsion mixtures using CSS-1h were generally higher than those of HFMS-2p. Flow number and flow time of CIR-emulsion using RAP materials from Story County was higher than those from Clayton County. Flow number and flow time of CIR-emulsion with 0.5% emulsified asphalt was higher than CIR-emulsion with 1.0% or 1.5%. Raveling loss of CIR-emulsion with 1.5% emulsified was significantly less than those with 0.5% and 1.0%. Test results in terms of dynamic modulus, flow number, flow time and raveling loss of CIR-foam mixtures are generally better than those of CIR-emulsion mixtures. Given the limited RAP sources used for this study, it is recommended that the CIR-emulsion mix design procedure should be validated against several RAP sources and emulsion types.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Stereopsis is the perception of depth based on retinal disparity. Global stereopsis depends on the process of random dot stimuli and local stereopsis depends on contour perception. The aim of this study was to correlate 3 stereopsis tests: TNO®, StereoTA B®, and Fly Stereo Acuity Test® and to study the sensitivity and correlation between them, using TNO® as the gold standard. Other variables as near convergence point, vergences, symptoms and optical correction were correlated with the 3 tests. Materials and Methods: Forty-nine students from Escola Superior de Tecnologia da Saúde de Lisboa (ESTeSL), aged 18-26 years old were included. Results: The stereopsis mean (standard-deviation-SD) values in each test were: TNO® = 87.04” ±84.09”; FlyTest® = 38.18” ±34.59”; StereoTA B® = 124.89’’ ±137.38’’. About the coefficient of determination: TNO® and StereoTA B® with R2 = 0.6 e TNO® and FlyTest® with R2 =0.2. Pearson correlation coefficient shows a positive correlation between TNO® and StereoTA B® (r = 0.784 with α = 0.01). Phi coefficient shows a strong and positive association between TNO® and StereoTA B® (Φ = 0.848 with α = 0.01). In the ROC Curve, the StereoTA B® has an area under the curve bigger than the FlyTest® with a sensivity of 92.3% for 94.4% of specificity, so it means that the test is sensitive with a good discriminative power. Conclusion: We conclude that the use of Stereopsis tests to study global Stereopsis are an asset for clinical use. This type of test is more sensitive, revealing changes in Stereopsis when it is actually changed, unlike the test Stereopsis, which often indicates normal Stereopsis, camouflaging a Stereopsis change. We noted also that the StereoTA B ® is very sensitive and despite being a digital application, possessed good correlation with the TNO®.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In cognitive tests, animals are often given a choice between two options and obtain a reward if they choose correctly. We investigated whether task format affects subjects' performance in a physical cognition test. In experiment 1, a two-choice memory test, 15 marmosets, Callithrix jacchus, had to remember the location of a food reward over time delays of increasing duration. We predicted that their performance would decline with increasing delay, but this was not found. One possible explanation was that the subjects were not sufficiently motivated to choose correctly when presented with only two options because in each trial they had a 50% chance of being rewarded. In experiment 2, we explored this possibility by testing eight naïve marmosets and seven squirrel monkeys, Saimiri sciureus, with both the traditional two-choice and a new nine-choice version of the memory test that increased the cost of a wrong choice. We found that task format affected the monkeys' performance. When choosing between nine options, both species performed better and their performance declined as delays became longer. Our results suggest that the two-choice format compromises the assessment of physical cognition, at least in memory tests with these New World monkeys, whereas providing more options, which decreases the probability of obtaining a reward when making a random guess, improves both performance and measurement validity of memory. Our findings suggest that two-choice tasks should be used with caution in comparisons within and across species because they are prone to motivational biases.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O trabalho desenvolvido centrou-se na preparação da acreditação NP EN ISO/IEC 17025 do Laboratório de Metrologia da empresa Frilabo para prestação de serviços na área das temperaturas, no ensaio a câmaras térmicas e na calibração de termómetros industriais. Considerando o âmbito do trabalho desenvolvido, são abordados nesta tese conceitos teóricos sobre temperatura e incertezas bem como considerações técnicas de medição da temperatura e cálculo de incertezas. São também referidas considerações sobre os diferentes tipos de câmaras térmicas e termómetros. O texto apresenta os documentos elaborados pelo autor sobre os procedimentos de ensaio a câmaras térmicas e respetivo procedimento de cálculo da incerteza. Também estão presentes neste texto documentos elaborados pelo autor sobre os procedimentos de calibração de termómetros industriais e respetivo procedimento de cálculo da incerteza. Relativamente aos ensaios a câmara térmicas e calibração de termómetros o autor elaborou os fluxogramas sobre a metodologia da medição da temperatura nos ensaios, a metodologia de medição da temperatura nas calibrações, e respetivos cálculos de incertezas. Nos diferentes anexos estão apresentados vários documentos tais como o modelo de folha de cálculo para tratamento de dados relativos ao ensaio, modelo de folha de cálculo para tratamento de dados relativo às calibrações, modelo de relatório de ensaio, modelo de certificado de calibração, folhas de cálculo para gestão de clientes/equipamentos e numeração automática de relatórios de ensaio e certificados de calibração que cumprem os requisitos de gestão do laboratório. Ainda em anexo constam todas as figuras relativas à monitorização da temperatura nas câmara térmicas como também as figuras da disposição dos termómetros no interior das câmaras térmicas. Todas as figuras que aparecem ao longo do documento que não estão referenciadas são da adaptação ou elaboração própria do autor. A decisão de alargar o âmbito da acreditação do Laboratório de Metrologia da Frilabo para calibração de termómetros, prendeu-se com o facto de que sendo acreditado como laboratório de ensaios na área das temperaturas, a realização da rastreabilidade dos padrões de medida internamente, permitiria uma gestão de recursos otimizada e rentabilizada. A metodologia da preparação de todo o processo de acreditação do Laboratório de Metrologia da Frilabo, foi desenvolvida pelo autor e está expressa ao longo do texto da tese incluindo dados relevantes para a concretização da referida acreditação nos dois âmbitos. A avaliação de todo o trabalho desenvolvido será efetuada pelo o organismo designado IPAC (Instituto Português de Acreditação) que confere a acreditação em Portugal. Este organismo irá auditar a empresa com base nos procedimentos desenvolvidos e nos resultados obtidos, sendo destes o mais importante o Balanço da Melhor Incerteza (BMI) da medição também conhecido por Melhor Capacidade de Medição (MCM), quer para o ensaio às câmaras térmicas, quer para a calibração dos termómetros, permitindo desta forma complementar os serviços prestados aos clientes fidelizados à Frilabo. As câmaras térmicas e os termómetros industriais são equipamentos amplamente utilizados em diversos segmentos industriais, engenharia, medicina, ensino e também nas instituições de investigação, sendo um dos objetivos respetivamente, a simulação de condições específicas controladas e a medição de temperatura. Para entidades acreditadas, como os laboratórios, torna-se primordial que as medições realizadas com e nestes tipos de equipamentos ostentem confiabilidade metrológica1, uma vez que, resultados das medições inadequados podem levar a conclusões equivocadas sobre os testes realizados. Os resultados obtidos nos ensaios a câmaras térmicas e nas calibrações de termómetros, são considerados bons e aceitáveis, uma vez que as melhores incertezas obtidas, podem ser comparadas, através de consulta pública do Anexo Técnico do IPAC, com as incertezas de outros laboratórios acreditados em Portugal. Numa abordagem mais experimental, pode dizer-se que no ensaio a câmaras térmicas a obtenção de incertezas mais baixas ou mais altas depende maioritariamente do comportamento, características e estado de conservação das câmaras, tornando relevante o processo de estabilização da temperatura no interior das mesmas. A maioria das fontes de incerteza na calibração dos termómetros são obtidas pelas características e especificações do fabricante dos equipamentos, que se traduzem por uma contribuição com o mesmo peso para o cálculo da incerteza expandida (a exatidão de fabricante, as incertezas herdadas de certificados de calibração, da estabilidade e da uniformidade do meio térmico onde se efetuam as calibrações). Na calibração dos termómetros as incertezas mais baixas obtêm-se para termómetros de resoluções mais baixas. Verificou-se que os termómetros com resolução de 1ºC não detetavam as variações do banho térmico. Nos termómetros com resoluções inferiores, o peso da contribuição da dispersão de leituras no cálculo da incerteza, pode variar consoante as características do termómetro. Por exemplo os termómetros com resolução de 0,1ºC, apresentaram o maior peso na contribuição da componente da dispersão de leituras. Pode concluir-se que a acreditação de um laboratório é um processo que não é de todo fácil. Podem salientar-se aspetos que podem comprometer a acreditação, como por exemplo a má seleção do ou dos técnicos e equipamentos (má formação do técnico, equipamento que não seja por exemplo adequado à gama, mal calibrado, etc…) que vão efetuar as medições. Se não for bem feita, vai comprometer todo o processo nos passos seguintes. Deve haver também o envolvimento do todos os intervenientes do laboratório, o gestor da qualidade, o responsável técnico e os técnicos, só assim é que é possível chegar à qualidade pretendida e à melhoria contínua da acreditação do laboratório. Outro aspeto importante na preparação de uma acreditação de um laboratório é a pesquisa de documentação necessária e adequada para poder tomar decisões corretas na elaboração dos procedimentos conducentes à referida. O laboratório tem de mostrar/comprovar através de registos a sua competência. Finalmente pode dizer-se que competência é a palavra chave de uma acreditação, pois ela manifesta-se nas pessoas, equipamentos, métodos, instalações e outros aspetos da instituição a que pertence o laboratório sob acreditação.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

International audience

Relevância:

100.00% 100.00%

Publicador:

Resumo:

African American women account for a disproportionate burden of cervical cancer incidence and mortality rate when compared to non-Hispanic White women. Cervical cancer is one of the most preventable types of cancer, and women can be screened for it with a routine Pap test. Given that religion occupies an essential place in African American lives, framing health messages with important spiritual themes and delivering them through a popular communication delivery channel may allow for a more culturally-relevant and accessible technology-based approach to promoting cervical cancer educational content to African American women. Using community-engaged research as a framework, the purpose of this multiple methods study was to develop, pilot test, and evaluate the feasibility, acceptability, and initial efficacy of a spiritually-based SMS text messaging intervention to increase cervical cancer awareness and Pap test screening intention among African American women. The study recruited church-attending African American women ages 21-65 and was conducted in three phases. Phases 1 and 2 consisted of a series of focus group discussions (n=15), cognitive response interviews (n=8), and initial usability testing that were conducted to inform the intervention development and modifications. Phase 3 utilized a non-experimental one-group pretest-posttest design to pilot test the 16-day text messaging intervention (n=52). Of the individuals enrolled, forty-six completed the posttest (retention rate=88%). Findings provided evidence for the early feasibility, high acceptability, and some initial efficacy of the CervixCheck intervention. There were significant pre-post increases observed for knowledge about cervical cancer and the Pap test (p = .001) and subjective norms (p = .006). Additionally, results post-intervention revealed that 83% of participants reported being either “satisfied” or “very satisfied” with the program and 85% found the text messages either “useful” or “very useful”. 85% of the participants also indicated that they would “likely” or “very likely” share the information they learned from the intervention with the women around them, with 39% indicating that they had already shared some of the information they received with others they knew. A spiritually-based SMS text messaging intervention could be a culturally appropriate and cost-effective method of promoting cervical cancer early detection information to African American women.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Combining information on kinetics and kinematics of the trunk during gait is important for both clinical and research purposes, since it can help in better understanding the mechanisms behind changes in movement patterns in chronic low back pain patients. Although three-dimensional gait analysis has been used to evaluate chronic low back pain and healthy individuals, the reliability and measurement error of this procedure have not been fully established. The main purpose of this thesis is to gain a better understanding about the differences in the biomechanics of the trunk and lower limbs during gait, in patients and healthy individuals. To achieve these aims, three studies were developed. The first two, adopted a prospective design and focused on the reliability and measurement error of gait analysis. In these test-retest studies, chronic low back pain and healthy individuals were submitted to a gait assessment protocol, with two distinct evaluation moments, separated by one week. Gait data was collected using a 13-camera opto-electronic system and three force platforms. Data analysis included the computation of time-distance parameters, as well as the peak values for lower limb and trunk joint angles/moments. The third study followed a cross sectional design, where gait in chronic low back pain individuals was compared with matched controls. Step-to-step variability of the thoracic, lumbar and hips was calculated, and step-to-step deviations of these segments from their average pattern (residual rotations) were correlated to each other. The reliability studies in this thesis show that three-dimensional gait analysis is a reliable and consistent procedure for both chronic low back pain and healthy individuals. The results suggest varied reliability indices for multi-segment trunk joint angles, joint moments and time-distance parameters during gait, together with an acceptable level of error (particularly regarding sagittal plane). Our findings also show altered stride-to-stride variability of lumbar and thoracic segments and lower trunk joint moments in patients. These kinematic and kinetic results lend support to the notion that chronic low back pain individuals exhibit a protective movement strategy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Concurrent software executes multiple threads or processes to achieve high performance. However, concurrency results in a huge number of different system behaviors that are difficult to test and verify. The aim of this dissertation is to develop new methods and tools for modeling and analyzing concurrent software systems at design and code levels. This dissertation consists of several related results. First, a formal model of Mondex, an electronic purse system, is built using Petri nets from user requirements, which is formally verified using model checking. Second, Petri nets models are automatically mined from the event traces generated from scientific workflows. Third, partial order models are automatically extracted from some instrumented concurrent program execution, and potential atomicity violation bugs are automatically verified based on the partial order models using model checking. Our formal specification and verification of Mondex have contributed to the world wide effort in developing a verified software repository. Our method to mine Petri net models automatically from provenance offers a new approach to build scientific workflows. Our dynamic prediction tool, named McPatom, can predict several known bugs in real world systems including one that evades several other existing tools. McPatom is efficient and scalable as it takes advantage of the nature of atomicity violations and considers only a pair of threads and accesses to a single shared variable at one time. However, predictive tools need to consider the tradeoffs between precision and coverage. Based on McPatom, this dissertation presents two methods for improving the coverage and precision of atomicity violation predictions: 1) a post-prediction analysis method to increase coverage while ensuring precision; 2) a follow-up replaying method to further increase coverage. Both methods are implemented in a completely automatic tool.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The most widespread work-related diseases are musculoskeletal disorders (MSD) caused by awkward postures and excessive effort to upper limb muscles during work operations. The use of wearable IMU sensors could monitor the workers constantly to prevent hazardous actions, thus diminishing work injuries. In this thesis, procedures are developed and tested for ergonomic analyses in a working environment, based on a commercial motion capture system (MoCap) made of 17 Inertial Measurement Units (IMUs). An IMU is usually made of a tri-axial gyroscope, a tri-axial accelerometer, and a tri-axial magnetometer that, through sensor fusion algorithms, estimates its attitude. Effective strategies for preventing MSD rely on various aspects: firstly, the accuracy of the IMU, depending on the chosen sensor and its calibration; secondly, the correct identification of the pose of each sensor on the worker’s body; thirdly, the chosen multibody model, which must consider both the accuracy and the computational burden, to provide results in real-time; finally, the model scaling law, which defines the possibility of a fast and accurate personalization of the multibody model geometry. Moreover, the MSD can be diminished using collaborative robots (cobots) as assisted devices for complex or heavy operations to relieve the worker's effort during repetitive tasks. All these aspects are considered to test and show the efficiency and usability of inertial MoCap systems for assessing ergonomics evaluation in real-time and implementing safety control strategies in collaborative robotics. Validation is performed with several experimental tests, both to test the proposed procedures and to compare the results of real-time multibody models developed in this thesis with the results from commercial software. As an additional result, the positive effects of using cobots as assisted devices for reducing human effort in repetitive industrial tasks are also shown, to demonstrate the potential of wearable electronics in on-field ergonomics analyses for industrial applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this thesis is to present the concept of simulation for automatic machines and how it might be used to test and debug software implemented for an automatic machine. The simulation is used to detect errors and allow corrections of the code before the machine has been built. Simulation permits testing different solutions and improving the software to get an optimized one. Additionally, simulation can be used to keep track of a machine after the installation in order to improve the production process during the machine’s life cycle. The central argument of this project is discussing the advantage of using virtual commissioning to test the implemented software in a virtual environment. Such an environment is getting benefit in avoiding potential damages as well as reduction of time to have the machine ready to work. Also, the use of virtual commissioning allows testing different solutions without high losses of time and money. Subsequently, an optimized solution could be found after testing different proposed solutions. The software implemented is based on the Object-Oriented Programming paradigm which implies different features such as encapsulation, modularity, and reusability of the code. Therefore, this way of programming helps to get simplified code that is easier to be understood and debugged as well as its high efficiency. Finally, different communication protocols are implemented in order to allow communication between the real plant and the simulation model. By the outcome that this communication provides, we might be able to gather all the necessary data for the simulation and the analysis, in real-time, of the production process in a way to improve it during the machine life cycle.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this thesis work, a cosmic-ray telescope was set up in the INFN laboratories in Bologna using smaller size replicas of CMS Drift Tubes chambers, called MiniDTs, to test and develop new electronics for the CMS Phase-2 upgrade. The MiniDTs were assembled in INFN National Laboratory in Legnaro, Italy. Scintillator tiles complete the telescope, providing a signal independent of the MiniDTs for offline analysis. The telescope readout is a test system for the CMS Phase-2 upgrade data acquisition design. The readout is based on the early prototype of a radiation-hard FPGA-based board developed for the High Luminosity LHC CMS upgrade, called On Board electronics for Drift Tubes. Once the set-up was operational, we developed an online monitor to display in real-time the most important observables to check the quality of the data acquisition. We performed an offline analysis of the collected data using a custom version of CMS software tools, which allowed us to estimate the time pedestal and drift velocity in each chamber, evaluate the efficiency of the different DT cells, and measure the space and time resolution of the telescope system.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim was to describe the outcome of neonatal hearing screening (NHS) and audiological diagnosis in neonates in the NICU. The sample was divided into Group I: neonates who underwent NHS in one step and Group II: neonates who underwent a test and retest NHS. NHS procedure was automated auditory brainstem response. NHS was performed in 82.1% of surviving neonates. For GI, referral rate was 18.6% and false-positive was 62.2% (normal hearing in the diagnostic stage). In GII, with retest, referral rate dropped to 4.1% and false-positive to 12.5%. Sensorineural hearing loss was found in 13.2% of infants and conductive in 26.4% of cases. There was one case of auditory neuropathy spectrum (1.9%). Dropout rate in whole process was 21.7% for GI and 24.03% for GII. We concluded that it was not possible to perform universal NHS in the studied sample or, in many cases, to apply it within the first month of life. Retest reduced failure and false-positive rate and did not increase evasion, indicating that it is a recommendable step in NHS programs in the NICU. The incidence of hearing loss was 2.9%, considering sensorineural hearing loss (0.91%), conductive (1.83%) and auditory neuropathy spectrum (0.19%).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the effectiveness of Reciproc for the removal of cultivable bacteria and endotoxins from root canals in comparison with multifile rotary systems. The root canals of forty human single-rooted mandibular pre-molars were contaminated with an Escherichia coli suspension for 21 days and randomly assigned to four groups according to the instrumentation system: GI - Reciproc (VDW); GII - Mtwo (VDW); GIII - ProTaper Universal (Dentsply Maillefer); and GIV -FKG Race(™) (FKG Dentaire) (n = 10 per group). Bacterial and endotoxin samples were taken with a sterile/apyrogenic paper point before (s1) and after instrumentation (s2). Culture techniques determined the colony-forming units (CFU) and the Limulus Amebocyte Lysate assay was used for endotoxin quantification. Results were submitted to paired t-test and anova. At s1, bacteria and endotoxins were recovered in 100% of the root canals investigated (40/40). After instrumentation, all systems were associated with a highly significant reduction of the bacterial load and endotoxin levels, respectively: GI - Reciproc (99.34% and 91.69%); GII - Mtwo (99.86% and 83.11%); GIII - ProTaper (99.93% and 78.56%) and GIV - FKG Race(™) (99.99% and 82.52%) (P < 0.001). No statistical difference were found amongst the instrumentation systems regarding bacteria and endotoxin removal (P > 0.01). The reciprocating single file, Reciproc, was as effective as the multifile rotary systems for the removal of bacteria and endotoxins from root canals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To identify the adherence rate of a statin treatment and possible related factors in female users from the Unified Health System. Seventy-one women were evaluated (64.2 ± 11.0 years) regarding the socio-economic level, comorbidities, current medications, level of physical activity, self-report of muscular pain, adherence to the medical prescription, body composition and biochemical profile. The data were analyzed as frequencies, Chi-Squared test, and Mann Whitney test (p<0.05). 15.5% of women did not adhere to the medical prescription for the statin treatment, whose had less comorbidities (p=0.01), consumed less quantities of medications (p=0.00), and tended to be younger (p=0.06). Those patients also presented higher values of lipid profile (CT: p=0.01; LDL-c: p=0.02). Musculoskeletal complains were not associated to the adherence rate to the medication. The associated factors to adherence of dyslipidemic women to statin medical prescription were age, quantity of comorbidities and quantity of current medication.