530 resultados para angiography
Resumo:
AIMS: We conducted a meta-analysis to evaluate the accuracy of quantitative stress myocardial contrast echocardiography (MCE) in coronary artery disease (CAD). METHODS AND RESULTS: Database search was performed through January 2008. We included studies evaluating accuracy of quantitative stress MCE for detection of CAD compared with coronary angiography or single-photon emission computed tomography (SPECT) and measuring reserve parameters of A, beta, and Abeta. Data from studies were verified and supplemented by the authors of each study. Using random effects meta-analysis, we estimated weighted mean difference (WMD), likelihood ratios (LRs), diagnostic odds ratios (DORs), and summary area under curve (AUC), all with 95% confidence interval (CI). Of 1443 studies, 13 including 627 patients (age range, 38-75 years) and comparing MCE with angiography (n = 10), SPECT (n = 1), or both (n = 2) were eligible. WMD (95% CI) were significantly less in CAD group than no-CAD group: 0.12 (0.06-0.18) (P < 0.001), 1.38 (1.28-1.52) (P < 0.001), and 1.47 (1.18-1.76) (P < 0.001) for A, beta, and Abeta reserves, respectively. Pooled LRs for positive test were 1.33 (1.13-1.57), 3.76 (2.43-5.80), and 3.64 (2.87-4.78) and LRs for negative test were 0.68 (0.55-0.83), 0.30 (0.24-0.38), and 0.27 (0.22-0.34) for A, beta, and Abeta reserves, respectively. Pooled DORs were 2.09 (1.42-3.07), 15.11 (7.90-28.91), and 14.73 (9.61-22.57) and AUCs were 0.637 (0.594-0.677), 0.851 (0.828-0.872), and 0.859 (0.842-0.750) for A, beta, and Abeta reserves, respectively. CONCLUSION: Evidence supports the use of quantitative MCE as a non-invasive test for detection of CAD. Standardizing MCE quantification analysis and adherence to reporting standards for diagnostic tests could enhance the quality of evidence in this field.
Resumo:
Within the past 15 years, significant advances in the imaging of multiorgan and complex trauma primarily due to the improvement of cross-sectional imaging have resulted in the optimization of the expedient diagnosis and management of the polytrauma patient. At the forefront, multidetector computed tomography (MDCT) has become the cornerstone of modern emergency departments and trauma centers. In many institutions, MDCT is the de facto diagnostic tool upon trauma activation. In the setting of pelvic imaging, MDCT (with its high spatial resolution and sensitivity as well as short acquisition times) allows for rapid identification and assessment of pelvic hemorrhage leading to faster triage and definitive management. In trauma centers throughout the world, angiography and minimally invasive catheter-based embolization techniques performed by interventional radiologists have become the standard of care for patients with acute pelvic trauma and related multiorgan hemorrhage. In an interdisciplinary setting, embolization may be performed either alone or as an adjunct procedure with open or closed reduction and stabilization techniques. A team-based approach involving multiple disciplines (e.g., radiology, traumatology, orthopedic surgery, intensive care medicine) is crucial to monitor and treat the actively bleeding patient appropriately.
Resumo:
Over the last two decades, imaging of the aorta has undergone a clinically relevant change. As part of the change non-invasive imaging techniques have replaced invasive intra-arterial digital subtraction angiography as the former imaging gold standard for aortic diseases. Computed tomography (CT) and magnetic resonance imaging (MRI) constitute the backbone of pre- and postoperative aortic imaging because they allow for imaging of the entire aorta and its branches. The first part of this review article describes the imaging principles of CT and MRI with regard to aortic disease, shows how both technologies can be applied in every day clinical practice, offering exciting perspectives. Recent CT scanner generations deliver excellent image quality with a high spatial and temporal resolution. Technical developments have resulted in CT scan performed within a few seconds for the entire aorta. Therefore, CT angiography (CTA) is the imaging technology of choice for evaluating acute aortic syndromes, for diagnosis of most aortic pathologies, preoperative planning and postoperative follow-up after endovascular aortic repair. However, radiation dose and the risk of contrast induced nephropathy are major downsides of CTA. Optimisation of scan protocols and contrast media administration can help to reduce the required radiation dose and contrast media. MR angiography (MRA) is an excellent alternative to CTA for both diagnosis of aortic pathologies and postoperative follow-up. The lack of radiation is particularly beneficial for younger patients. A potential side effect of gadolinium contrast agents is nephrogenic systemic fibrosis (NSF). In patients with high risk of NSF unenhanced MRA can be performed with both ECG- and breath-gating techniques. Additionally, MRI provides the possibility to visualise and measure both dynamic and flow information.
Resumo:
Transcatheter aortic valve replacement (TAVR) as well as thoracic and abdominal endovascular aortic repair (TEVAR and EVAR) rely on accurate pre- and postprocedural imaging. This review article discusses the application of imaging, including preprocedural assessment and measurements as well as postprocedural imaging of complications. Furthermore, the exciting perspective of computational fluid dynamics (CFD) based on cross-sectional imaging is presented. TAVR is a minimally invasive alternative for treatment of aortic valve stenosis in patients with high age and multiple comorbidities who cannot undergo traditional open surgical repair. Given the lack of direct visualization during the procedure, pre- and peri-procedural imaging forms an essential part of the intervention. Computed tomography angiography (CTA) is the imaging modality of choice for preprocedural planning. Routine postprocedural follow-up is performed by echocardiography to confirm treatment success and detect complications. EVAR and TEVAR are minimally invasive alternatives to open surgical repair of aortic pathologies. CTA constitutes the preferred imaging modality for both preoperative planning and postoperative follow-up including detection of endoleaks. Magnetic resonance imaging is an excellent alternative to CT for postoperative follow-up, and is especially beneficial for younger patients given the lack of radiation. Ultrasound is applied in screening and postoperative follow-up of abdominal aortic aneurysms, but cross-sectional imaging is required once abnormalities are detected. Contrast-enhanced ultrasound may be as sensitive as CTA in detecting endoleaks.
Resumo:
We present a case of a ruptured abdominal aortic aneurysm (AAA) with ambiguous accessory findings on post-mortem computed-tomography (PMCT), post-mortem magnetic resonance (PMMR) imaging, and PMCT-angiography (PMCTA) suggestive of thoracic aortic dissection. The diagnosis of ruptured AAA was confirmed by autopsy; however, there was no aortic dissection. The imaging findings that mimicked the presence of aortic dissection might have been an atypical presentation of post-mortem clotting or sedimentation. This case is an ideal example to illustrate benefits, limitations, and challenges of post-mortem cross-sectional imaging. It serves as a reminder that both, training as well as correlation of imaging findings with autopsy are fundamental to improve our understanding of radiologic findings on post-mortem cross-sectional imaging.
Resumo:
PURPOSE Geographic atrophy (GA) is the end-stage manifestation of atrophic age-related macular degeneration (AMD). The disease progresses slowly over time, eventually causing loss of central vision. Its cause and pathomechanism are not fully known. Previous studies have suggested that vitreoretinal traction (VRT) may contribute to the progression of neovascular AMD. The aim of this study was to examine whether an association between changes at the vitreoretinal interface (VRI), in particular traction (VRT), and the characteristics and progression of GA in eyes with dry AMD can be established. DESIGN Clinic-based prospective cohort study. PARTICIPANTS A total of 97 patients (age range, 61-90 years; mean, 78.4 years) with GA secondary to dry AMD were enrolled. Patients exhibiting neovascular signs on fluorescein angiography in either eye were excluded. METHODS The VRI changes were examined using spectral-domain optical coherence tomography (SD-OCT). Characteristics of GA were examined using fundus autofluorescence (FAF) imaging. All imaging was performed using a Spectralis SLO+OCT device (Heidelberg Engineering, Heidelberg, Germany); GA area was measured using the Region Finder (Heidelberg Engineering) software native to the Spectralis platform. MAIN OUTCOME MEASURES Area and increase in area of GA. RESULTS A total of 97 eyes were examined. Vitreoretinal traction was found in 39 eyes (40%). The GA area at baseline was 6.65±5.64 mm(2) in eyes with VRT and 5.73±4.72 mm(2) in eyes with no VRT. The annual rate of progression of GA area progression was 2.99±0.66 mm(2) in eyes with VRT and 1.45±0.67mm(2) in eyes without VRT. Differences between groups in both parameters were statistically significant (n = 97 total number of eyes; P<0.001). Multiple regression analysis confirmed this finding (B = 0.714, P<0.001; F3,93 = 72.542, P<0.001; adjusted R(2) = 0.691) CONCLUSIONS: Our results indicate an association between VRT and an increased rate of progression of GA area in dry AMD. Monitoring VRT may contribute to an improved estimate of the prospective time of visual loss and to a better timing of emerging therapies in dry AMD.
Resumo:
BACKGROUND This study sought to determine whether the 1-year differences in major adverse cardiac event between a stent eluting biolimus from a biodegradable polymer and bare-metal stents (BMSs) in the COMFORTABLE trial (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal Stents in Acute ST-Elevation Myocardial Infarction) were sustained during long-term follow-up. METHODS AND RESULTS A total of 1061 patients were randomly assigned to biolimus-eluting stent (BES) and BMS at 11 centers, and follow-up rates at 2 years were 96.3%. A subgroup of 103 patients underwent angiography at 13 months. At 2 years, differences in the primary end point of cardiac death, target-vessel myocardial infarction, and target lesion revascularization continued to diverge in favor of BES-treated patients (5.8%) compared with BMS-treated patients (11.9%; hazard ratio=0.48; 95% confidence interval, 0.31-0.72; P<0.001) with a significant risk reduction during the second year of follow-up (hazard ratio 1-2 years=0.45; 95% confidence interval, 0.20-1.00; P=0.049). Differences in the primary end point were driven by a reduction in target lesion revascularization (3.1% versus 8.2%; P<0.001) and target-vessel reinfarction (1.3% versus 3.4%; P=0.023). The composite of death, any reinfarction and revascularization (14.5% versus 19.3%; P=0.03), and cardiac death or target-vessel myocardial infarction (4.2% versus 7.2%; P=0.036) were less frequent among BES-treated patients compared with BMS-treated patients. The 13-month angiographic in-stent percent diameter stenosis amounted to 12.0±7.2 in BES- and 39.6±25.2 in BMS-treated lesions (P<0.001). CONCLUSIONS Among patients with ST-segment-elevation myocardial infarction undergoing primary percutaneous coronary intervention, BES continued to improve cardiovascular events compared with BMS beyond 1 year.
Resumo:
OBJECTIVES Susceptibility-weighted imaging (SWI) enables visualization of thrombotic material in acute ischemic stroke. We aimed to validate the accuracy of thrombus depiction on SWI compared to time-of-flight MRA (TOF-MRA), first-pass gadolinium-enhanced MRA (GE-MRA) and digital subtraction angiography (DSA). Furthermore, we analysed the impact of thrombus length on reperfusion success with endovascular therapy. METHODS Consecutive patients with acute ischemic stroke due to middle cerebral artery (MCA) occlusions undergoing endovascular recanalization were screened. Only patients with a pretreatment SWI were included. Thrombus visibility and location on SWI were compared to those on TOF-MRA, GE-MRA and DSA. The association between thrombus length on SWI and reperfusion success was studied. RESULTS Eighty-four of the 88 patients included (95.5 %) showed an MCA thrombus on SWI. Strong correlations between thrombus location on SWI and that on TOF-MRA (Pearson's correlation coefficient 0.918, P < 0.001), GE-MRA (0.887, P < 0.001) and DSA (0.841, P < 0.001) were observed. Successful reperfusion was not significantly related to thrombus length on SWI (P = 0.153; binary logistic regression). CONCLUSIONS In MCA occlusion thrombus location as seen on SWI correlates well with angiographic findings. In contrast to intravenous thrombolysis, thrombus length appears to have no impact on reperfusion success of endovascular therapy. KEY POINTS • SWI helps in assessing location and length of thrombi in the MCA • SWI, MRA and DSA are equivalent in detecting the MCA occlusion site • SWI is superior in identifying the distal end of the thrombus • Stent retrievers should be deployed over the distal thrombus end • Thrombus length did not affect success of endovascular reperfusion guided by SWI.
Resumo:
BACKGROUND AND PURPOSE We report on workflow and process-based performance measures and their effect on clinical outcome in Solitaire FR Thrombectomy for Acute Revascularization (STAR), a multicenter, prospective, single-arm study of Solitaire FR thrombectomy in large vessel anterior circulation stroke patients. METHODS Two hundred two patients were enrolled across 14 centers in Europe, Canada, and Australia. The following time intervals were measured: stroke onset to hospital arrival, hospital arrival to baseline imaging, baseline imaging to groin puncture, groin puncture to first stent deployment, and first stent deployment to reperfusion. Effects of time of day, general anesthesia use, and multimodal imaging on workflow were evaluated. Patient characteristics and workflow processes associated with prolonged interval times and good clinical outcome (90-day modified Rankin score, 0-2) were analyzed. RESULTS Median times were onset of stroke to hospital arrival, 123 minutes (interquartile range, 163 minutes); hospital arrival to thrombolysis in cerebral infarction (TICI) 2b/3 or final digital subtraction angiography, 133 minutes (interquartile range, 99 minutes); and baseline imaging to groin puncture, 86 minutes (interquartile range, 24 minutes). Time from baseline imaging to puncture was prolonged in patients receiving intravenous tissue-type plasminogen activator (32-minute mean delay) and when magnetic resonance-based imaging at baseline was used (18-minute mean delay). Extracranial carotid disease delayed puncture to first stent deployment time on average by 25 minutes. For each 1-hour increase in stroke onset to final digital subtraction angiography (or TICI 2b/3) time, odds of good clinical outcome decreased by 38%. CONCLUSIONS Interval times in the STAR study reflect current intra-arterial therapy for patients with acute ischemic stroke. Improving workflow metrics can further improve clinical outcome. CLINICAL TRIAL REGISTRATION: URL http://www.clinicaltrials.gov. Unique identifier: NCT01327989.
Resumo:
BACKGROUND The extent of hypoperfusion is an important prognostic factor in acute ischemic stroke. Previous studies have postulated that the extent of prominent cortical veins (PCV) on susceptibility-weighted imaging (SWI) reflects the extent of hypoperfusion. Our aim was to investigate, whether there is an association between PCV and the grade of leptomeningeal arterial collateralization in acute ischemic stroke. In addition, we analyzed the correlation between SWI and perfusion-MRI findings. METHODS 33 patients with acute ischemic stroke due to a thromboembolic M1-segment occlusion underwent MRI followed by digital subtraction angiography (DSA) and were subdivided into two groups with very good to good and moderate to no leptomeningeal collaterals according to the DSA. The extent of PCV on SWI, diffusion restriction (DR) on diffusion-weighted imaging (DWI) and prolonged mean transit time (MTT) on perfusion-imaging were graded according to the Alberta Stroke Program Early CT Score (ASPECTS). The National Institutes of Health Stroke Scale (NIHSS) scores at admission and the time between symptom onset and MRI were documented. RESULTS 20 patients showed very good to good and 13 patients poor to no collateralization. PCV-ASPECTS was significantly higher for cases with good leptomeningeal collaterals versus those with poor leptomeningeal collaterals (mean 4.1 versus 2.69; p=0.039). MTT-ASPECTS was significantly lower than PCV-ASPECTS in all 33 patients (mean 1.0 versus 3.5; p<0.00). CONCLUSIONS In our small study the grade of leptomeningeal collateralization correlates with the extent of PCV in SWI in acute ischemic stroke, due to the deoxyhemoglobin to oxyhemoglobin ratio. Consequently, extensive PCV correlate with poor leptomeningeal collateralization while less pronounced PCV correlate with good leptomeningeal collateralization. Further SWI is a very helpful tool in detecting tissue at risk but cannot replace PWI since MTT detects significantly more ill-perfused areas than SWI, especially in good collateralized subjects.
Resumo:
BACKGROUND Copper and its main transport protein ceruloplasmin have been suggested to promote the development of atherosclerosis. Most of the data come from experimental and animal model studies. Copper and mortality have not been simultaneously evaluated in patients undergoing coronary angiography. METHODS AND RESULTS We examined whether serum copper and ceruloplasmin concentrations are associated with angiographic coronary artery disease (CAD) and mortality from all causes and cardiovascular causes in 3253 participants of the Ludwigshafen Risk and Cardiovascular Health Study. Age and sex-adjusted hazard ratios (HR) for death from any cause were 2.23 (95% CI, 1.85-2.68) for copper and 2.63 (95% CI, 2.17-3.20) for ceruloplasmin when we compared the highest with the lowest quartiles. Corresponding hazard ratios (HR) for death from cardiovascular causes were 2.58 (95% CI, 2.05-3.25) and 3.02 (95% CI, 2.36-3.86), respectively. Further adjustments for various risk factors and clinical variables considerably attenuated these associations, which, however, were still statistically significant and the results remained consistent across subgroups. CONCLUSIONS The elevated concentrations of both copper and ceruloplasmin are independently associated with increased risk of mortality from all causes and from cardiovascular causes.
Resumo:
AIMS The aim of the study was to examine whether differences in average diameter of low-density lipoprotein (LDL) particles were associated with total and cardiovascular mortality. METHODS AND RESULTS We studied 1643 subjects referred to coronary angiography, who did not receive lipid-lowering drugs. During a median follow-up of 9.9 years, 398 patients died, of these 246 from cardiovascular causes. We calculated average particle diameters of LDL from the composition of LDL obtained by β-quantification. When LDL with intermediate average diameters (16.5-16.8 nm) were used as reference category, the hazard ratios (HRs) adjusted for cardiovascular risk factors for death from any cause were 1.71 (95% CI: 1.31-2.25) and 1.24 (95% CI: 0.95-1.63) in patients with large (>16.8 nm) or small LDL (<16.5 nm), respectively. Adjusted HRs for death from cardiovascular causes were 1.89 (95% CI: 1.32-2.70) and 1.54 (95% CI: 1.06-2.12) in patients with large or small LDL, respectively. Patients with large LDL had higher concentrations of the inflammatory markers interleukin (IL)-6 and C-reactive protein than patients with small or intermediate LDL. Equilibrium density gradient ultracentrifugation revealed characteristic and distinct profiles of LDL particles in persons with large (approximately even distribution of intermediate-density lipoproteins and LDL-1 through LDL-6) intermediate (peak concentration at LDL-4) or small (peak concentration at LDL-6) average LDL particle diameters. CONCLUSIONS Calculated LDL particle diameters identify patients with different profiles of LDL subfractions. Both large and small LDL diameters are independently associated with increased risk mortality of all causes and, more so, due to cardiovascular causes compared with LDL of intermediate size.
Resumo:
In the general population, HDL cholesterol (HDL-C) is associated with reduced cardiovascular events. However, recent experimental data suggest that the vascular effects of HDL can be heterogeneous. We examined the association of HDL-C with all-cause and cardiovascular mortality in the Ludwigshafen Risk and Cardiovascular Health study comprising 3307 patients undergoing coronary angiography. Patients were followed for a median of 9.9 years. Estimated GFR (eGFR) was calculated using the Chronic Kidney Disease Epidemiology Collaboration eGFR creatinine-cystatin C (eGFRcreat-cys) equation. The effect of increasing HDL-C serum levels was assessed using Cox proportional hazard models. In participants with normal kidney function (eGFR>90 ml/min per 1.73 m(2)), higher HDL-C was associated with reduced risk of all-cause and cardiovascular mortality and coronary artery disease severity (hazard ratio [HR], 0.51, 95% confidence interval [95% CI], 0.26-0.92 [P=0.03]; HR, 0.30, 95% CI, 0.13-0.73 [P=0.01]). Conversely, in patients with mild (eGFR=60-89 ml/min per 1.73 m(2)) and more advanced reduced kidney function (eGFR<60 ml/min per 1.73 m(2)), higher HDL-C did not associate with lower risk for mortality (eGFR=60-89 ml/min per 1.73 m(2): HR, 0.68, 95% CI, 0.45-1.04 [P=0.07]; HR, 0.84, 95% CI, 0.50-1.40 [P=0.50]; eGFR<60 ml/min per 1.73 m(2): HR, 1.18, 95% CI, 0.60-1.81 [P=0.88]; HR, 0.82, 95% CI, 0.40-1.69 [P=0.60]). Moreover, Cox regression analyses revealed interaction between HDL-C and eGFR in predicting all-cause and cardiovascular mortality (P=0.04 and P=0.02, respectively). We confirmed a lack of association between higher HDL-C and lower mortality in an independent cohort of patients with definite CKD (P=0.63). In summary, higher HDL-C levels did not associate with reduced mortality risk and coronary artery disease severity in patients with reduced kidney function. Indeed, abnormal HDL function might confound the outcome of HDL-targeted therapies in these patients.
Resumo:
Background We hypothesized that in patients with stable coronary artery disease and stenosis, percutaneous coronary intervention (PCI) performed on the basis of the fractional flow reserve (FFR) would be superior to medical therapy. Methods In 1220 patients with stable coronary artery disease, we assessed the FFR in all stenoses that were visible on angiography. Patients who had at least one stenosis with an FFR of 0.80 or less were randomly assigned to undergo FFR-guided PCI plus medical therapy or to receive medical therapy alone. Patients in whom all stenoses had an FFR of more than 0.80 received medical therapy alone and were included in a registry. The primary end point was a composite of death from any cause, nonfatal myocardial infarction, or urgent revascularization within 2 years. Results The rate of the primary end point was significantly lower in the PCI group than in the medical-therapy group (8.1% vs. 19.5%; hazard ratio, 0.39; 95% confidence interval [CI], 0.26 to 0.57; P<0.001). This reduction was driven by a lower rate of urgent revascularization in the PCI group (4.0% vs. 16.3%; hazard ratio, 0.23; 95% CI, 0.14 to 0.38; P<0.001), with no significant between-group differences in the rates of death and myocardial infarction. Urgent revascularizations that were triggered by myocardial infarction or ischemic changes on electrocardiography were less frequent in the PCI group (3.4% vs. 7.0%, P=0.01). In a landmark analysis, the rate of death or myocardial infection from 8 days to 2 years was lower in the PCI group than in the medical-therapy group (4.6% vs. 8.0%, P=0.04). Among registry patients, the rate of the primary end point was 9.0% at 2 years. Conclusions In patients with stable coronary artery disease, FFR-guided PCI, as compared with medical therapy alone, improved the outcome. Patients without ischemia had a favorable outcome with medical therapy alone. (Funded by St. Jude Medical; FAME 2 ClinicalTrials.gov number, NCT01132495 .).
Resumo:
Postmortem MRI (PMMR) examinations are seldom performed in legal medicine due to long examination times, unfamiliarity with the technique, and high costs. Furthermore, it is difficult to obtain access to an MRI device used for patients in clinical settings to image an entire human body. An alternative is available: ex situ organ examination. To our knowledge, there is no standardized protocol that includes ex situ organ preparation and scanning parameters for postmortem MRI. Thus, our objective was to develop a standard procedure for ex situ heart PMMR examinations. We also tested the oily contrast agent Angiofil® commonly used for PMCT angiography, for its applicability in MRI. We worked with a 3 Tesla MRI device and 32-channel head coils. Twelve porcine hearts were used to test different materials to find the best way to prepare and place organs in the device and to test scanning parameters. For coronary MR angiography, we tested different mixtures of Angiofil® and different injection materials. In a second step, 17 human hearts were examined to test the procedure and its applicability to human organs. We established two standardized protocols: one for preparation of the heart and another for scanning parameters based on experience in clinical practice. The established protocols enabled a standardized technical procedure with comparable radiological images, allowing for easy radiological reading. The performance of coronary MR angiography enabled detailed coronary assessment and revealed the utility of Angiofil® as a contrast agent for PMMR. Our simple, reproducible method for performing heart examinations ex situ yields high quality images and visualization of the coronary arteries.