913 resultados para all-solid-state


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Magnetic properties of Fe nanodots are simulated using a scaling technique and Monte Carlo method, in good agreement with experimental results. For the 20-nm-thick dots with diameters larger than 60¿nm, the magnetization reversal via vortex state is observed. The role of magnetic interaction between dots in arrays in the reversal process is studied as a function of nanometric center-to-center distance. When this distance is more than twice the dot diameter, the interaction can be neglected and the magnetic properties of the entire array are determined by the magnetic configuration of the individual dots. The effect of crystalline anisotropy on the vortex state is investigated. For arrays of noninteracting dots, the anisotropy strongly affects the vortex nucleation field and coercivity, and only slightly affects the vortex annihilation field

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Antifreeze proteins (AFPs) inhibit ice growth at sub-zero temperatures. The prototypical type-III AFPs have been extensively studied, notably by X-ray crystallography, solid-state and solution NMR, and mutagenesis, leading to the identification of a compound ice-binding surface (IBS) composed of two adjacent ice-binding sections, each which binds to particular lattice planes of ice crystals, poisoning their growth. This surface, including many hydrophobic and some hydrophilic residues, has been extensively used to model the interaction of AFP with ice. Experimentally observed water molecules facing the IBS have been used in an attempt to validate these models. However, these trials have been hindered by the limited capability of X-ray crystallography to reliably identify all water molecules of the hydration layer. Due to the strong diffraction signal from both the oxygen and deuterium atoms, neutron diffraction provides a more effective way to determine the water molecule positions (as D(2) O). Here we report the successful structure determination at 293 K of fully perdeuterated type-III AFP by joint X-ray and neutron diffraction providing a very detailed description of the protein and its solvent structure. X-ray data were collected to a resolution of 1.05 Å, and neutron Laue data to a resolution of 1.85 Å with a "radically small" crystal volume of 0.13 mm(3). The identification of a tetrahedral water cluster in nuclear scattering density maps has allowed the reconstruction of the IBS-bound ice crystal primary prismatic face. Analysis of the interactions between the IBS and the bound ice crystal primary prismatic face indicates the role of the hydrophobic residues, which are found to bind inside the holes of the ice surface, thus explaining the specificity of AFPs for ice versus water.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The electronic and magnetic structures of the LaMnO3 compound have been studied by means of periodic calculations within the framework of spin polarized hybrid density-functional theory. In order to quantify the role of approximations to electronic exchange and correlation three different hybrid functionals have been used which mix nonlocal Fock and local Dirac-Slater exchange. Periodic Hartree-Fock results are also reported for comparative purposes. The A-antiferromagnetic ground state is properly predicted by all methods including Hartree-Fock exchange. In general, the different hybrid methods provide a rather accurate description of the band gap and of the two magnetic coupling constants, strongly suggesting that the corresponding description of the electronic structure is also accurate. An important conclusion emerging from this study is that the nature of the occupied states near the Fermi level is intermediate between the Hartree-Fock and local density approximation descriptions with a comparable participation of both Mn and O states.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Depth-dose curves in LiF detectors of different effective thicknesses, together with their responses, were calculated for typical nuclear medicine radiation fields with 99mTc, 18F and 90Y sources. Responses were analysed in function of the radionuclide, detector effective thickness and irradiation geometry. On the other hand the results of the nuclear medicine measurement campaign of the ORAMED project were presented focussing on the dose distribution across the hand and on the appropriate position to wear the dosimeter.According to the results, thin LiF detectors provide better responses in all cases. Its use is essential for 18F, since thick dosimeters can underestimate Hp(0.07) up to a 50% because of the very inhomogeneous dose deposition on the active layer. The preliminary results of the measurement campaign showed that the index tip of the non-dominant hand is usually the most exposed position among the 22 monitored positions. It was also found that, in average, wrist dosimeters are likely to underestimate the maximum skin dose by a factor of the order of 20. This factor is reduced to around 6 for a ring dosimeter worn on the base of the index of the non-dominant hand. Thus, for typical nuclear medicine procedures, the base of the index of the non-dominant hand is recommended as the best monitoring option.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the intraocular pressure (IOP)-lowering effect of modified goniopuncture with the 532-nm Nd : YAG selective laser trabeculoplasty (SLT) laser on eyes after deep sclerectomy with collagen implant (DSCI). This was an interventional cased series. The effects of modified goniopuncture on eyes with insufficient IOP-lowering after DSCI were observed. Goniopuncture was performed using a Q-switched, frequency-doubled 532-nm Nd : YAG laser (SLT-goniopuncture, SLT-G). Outcome measures were amount of IOP-lowering and rapidity of decrease after laser intervention. In all, 10 eyes of 10 patients with a mean age of 71.0±7.7 (SD) years were treated with SLT-G. The mean time of SLT-G after DSCI procedure was 7.1±10.9 months. SLT-G decreased IOP from an average of 16.1±3.4 mm Hg to 14.2±2.8 mm Hg (after 15 min), 13.6±3.9 mm Hg (at 1 day), 12.5±4.1 mm Hg (at 1 month), and 12.6±2.5 (at 6 months) (P<0.0125). There were no complications related to the intervention. Patients in this series achieved an average 22.5% of IOP reduction after SLT-G. The use of the SLT laser appears to be an effective and safe alternative to the traditional Nd : YAG laser for goniopuncture in eyes after DSCI, with potential advantages related to non-perforation of trabeculo-descemet's membrane (TDM).

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Electrocaloric cooling based on ability of material to change temperature by applying an electric field under adiabatic conditions is relatively new and challenging direction of ferroelectrics research. In this work we report about analytical, simulation and experimental data for BaSrTiO3 thin film and bulk ceramic samples. Detailed discussion of a theoretical base of the electrocaloric effect is included. Demonstrated experimental and computational results exemplify rational approach to a problem of solid-state cooler construction.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Quality inspection and assurance is a veryimportant step when today's products are sold to markets. As products are produced in vast quantities, the interest to automate quality inspection tasks has increased correspondingly. Quality inspection tasks usuallyrequire the detection of deficiencies, defined as irregularities in this thesis. Objects containing regular patterns appear quite frequently on certain industries and science, e.g. half-tone raster patterns in the printing industry, crystal lattice structures in solid state physics and solder joints and components in the electronics industry. In this thesis, the problem of regular patterns and irregularities is described in analytical form and three different detection methods are proposed. All the methods are based on characteristics of Fourier transform to represent regular information compactly. Fourier transform enables the separation of regular and irregular parts of an image but the three methods presented are shown to differ in generality and computational complexity. Need to detect fine and sparse details is common in quality inspection tasks, e.g., locating smallfractures in components in the electronics industry or detecting tearing from paper samples in the printing industry. In this thesis, a general definition of such details is given by defining sufficient statistical properties in the histogram domain. The analytical definition allowsa quantitative comparison of methods designed for detail detection. Based on the definition, the utilisation of existing thresholding methodsis shown to be well motivated. Comparison of thresholding methods shows that minimum error thresholding outperforms other standard methods. The results are successfully applied to a paper printability and runnability inspection setup. Missing dots from a repeating raster pattern are detected from Heliotest strips and small surface defects from IGT picking papers.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fetoscopic coagulation of placental anastomoses is the treatment of choice for severe twin-to-twin transfusion syndrome. In the present day, fetal laser therapy is also used to treat amniotic bands, chorioangiomas, sacrococcygeal teratomas, lower urinary tract obstructions and chest masses, all of which will be reviewed in this article. Amniotic band syndrome can cause limb amputation by impairing downstream blood flow. Large chorioangiomas (>4 cm), sacrococcygeal teratomas or fetal hyperechoic lung lesions can lead to fetal compromise and hydrops by vascular steal phenomenon or compression. Renal damage, bladder dysfunction and lastly death because of pulmonary hypolasia may be the result of megacystis caused by a posterior urethral valve. The prognosis of these pathologies can be dismal, and therapy options are limited, which has brought fetal laser therapy to the forefront. Management options discussed here are laser release of amniotic bands, laser coagulation of the placental or fetal tumor feeding vessels and laser therapy by fetal cystoscopy. This review, largely based on case reports, does not intend to provide a level of evidence supporting laser therapy over other treatment options. Centralized evaluation by specialists using strict selection criteria and long-term follow-up of these rare cases are now needed to prove the value of endoscopic or ultrasound-guided laser therapy.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Rare earth elements supported in zeolites are the most important catalysts in the fluid cracking of petroleum. The solid state ion exchange of Eu3+ in Y zeolite was investigated. First of all, the hydrated EuCl3 was well mixed in a ball mill and was then heated at 300ºC for different times. The quantitative determination of Eu3+ showed that the degree of ion exchange depends on the reaction time at constant temperature, being ~95% in 4 h. The X-ray study showed that the crystallinity of the zeolite is little affected by the exchange procedure. The study of spectroscopic properties of Eu3+, emission spectra and lifetime, give information about the migration and position of the ion in the zeolite cages.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Complexation between acyclovir (ACV), an antiviral drug used for the treatment of herpes simplex virus infection, and beta-cyclodextrin (beta-CD) was studied in solution and in solid states. Complexation in solution was evaluated using solubility studies and nuclear magnetic resonance spectroscopy (¹H-NMR). In the solid state, X-ray diffraction, differential scanning calorimetry (DSC), thermal gravimetric analysis (TGA) and dissolution studies were used. Solubility studies suggested the existence of a 1:1 complex between ACV and beta-CD. ¹H-NMR spectroscopy studies showed that the complex formed occurs with a stoichiometry ratio of 1:1. Powder X-ray diffraction indicated that ACV exists in a semicrystalline state in the complexed form with beta-CD. DSC studies showed the existence of a complex of ACV with beta-CD. The TGA studies confirmed the DSC results of the complex. Solubility of ACV in solid complexes was studied by the dissolution method and it was found to be much more soluble than the uncomplexed drug.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Chalcone and its fluorinated derivatives were synthesized and photolyzed in the solid state. UV irradiation of chalcone and its monosubstituted fluorine derivatives (3- and 4-fluorchalcone) resulted in a mixture of anti-head-head (gamma-truxinic), sin-head-tail (alpha-truxilic) and anti-head-tail (epsilon-truxilic) dimers. On the other hand, upon irradiation of 3,4- and 3,5-difluorchalcone a stereoselective formation of the alpha-truxilic photodimer was observed, whereas for 2-substituted chalcones (2,3difluorchalcone, 2,5-difluorchalcone, 2,6-difluorchalcone and 2,3,4-trifluorchalcone) the beta-truxilic dimer was stereoselectively obtained. 2',3',4',5',6'-pentafluorchalcone was the less reactive of all chalcones studied and at least one of the possible photodimers, i.e the anti-head-head isomer, was identified. Irradiation of polyfluorinated chalcones such as 2,3,5,6-tetrafluor-, 2,3,4,5,6-pentafluor-, and 2,2',3,3',4,4',5,5',6,6'-decafluorchalcone led only to polymerization and/or decomposition products.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This work reports the synthesis and characterization of adducts of general formula MCl2.ngly, where M= Mn and Cu; n= 2 and 4, and gly= glycine. The manganese adducts were synthesized by dissolution of both, manganese chloride and glycine in water, whereas the copper adducts were obtained by using an alternative solid state synthesis approach. For all adducts, the obtained infrared data shows that the coordination involves the amine nitrogen atom, as well as an oxygen atom of the COO- group. The TG curves for the synthesized adducts exhibit only one mass loss step associated with the release of glycine molecules.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Complexes with the composition Ln(NO3)3.2DTPO.4H2O (Ln = Nd and Er) were synthesized and characterized by infrared and visible absorption spectra (solid state and solution). The results of the absorption spectra in the solid state suggest that metal-ligand bonds are essentially electrostatic in all complexes. The absorption spectra of the nitrate salt solution presented smaller values of the oscillator strength when compared to the spectra of the complexes in the same solvent.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This study describes unpublished research on improving the solubility of benznidazole by the formation of an inclusion complex. The cyclodextrins selected were αCD, βCD, γCD, HPβCD, RMβCD and SBβCD. All complexes were obtained in solution, presenting 1:1 stoichiometry according to the phase solubility diagram. The highest association constants were obtained with RMβCD and SBβCD, being selected for attainment of solid state complexes. These were characterized using XRD, SEM and dissolution test. The data obtained suggest the formation of complexes and indicate that these may provide a promising alternative way of developing solid doses of drug with suitable biopharmaceutical properties.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Solid-state silicon detectors have replaced conventional ones in almost all recent high-energy physics experiments. Pixel silicon sensors don't have any alternative in the area near the interaction point because of their high resolution and fast operation speed. However, present detectors hardly withstand high radiation doses. Forthcoming upgrade of the LHC in 2014 requires development of a new generation of pixel detectors which will be able to operate under ten times increased luminosity. A planar fabrication technique has some physical limitations; an improvement of the radiation hardness will reduce sensitivity of a detector. In that case a 3D pixel detector seems to be the most promising device which can overcome these difficulties. The objective of this work was to model a structure of the 3D stripixel detector and to simulate electrical characteristics of the device. Silvaco Atlas software has been used for these purposes. The structures of single and double sided dual column detectors with active edges were described using special command language. Simulations of these detectors have shown that electric field inside an active area has more uniform distribution in comparison to the planar structure. A smaller interelectrode space leads to a stronger field and also decreases the collection time. This makes the new type of detectors more radiation resistant. Other discovered advantages are the lower full depletion voltage and increased charge collection efficiency. So the 3D stripixel detectors have demonstrated improved characteristics and will be a suitable replacement for the planar ones.