892 resultados para Trials (Assault and battery)


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Our purpose was to perform a systematic review and meta-analysis of randomized trials comparing percutaneous coronary intervention (PCI) of the infarct-related artery (IRA) with medical therapy in patients randomized >12 h after acute myocardial infarction (AMI).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Uncertainty persists concerning the effect of improved long-term glycemic control on macrovascular disease in diabetes mellitus (DM).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND: Erythropoiesis-stimulating agents reduce anaemia in patients with cancer and could improve their quality of life, but these drugs might increase mortality. We therefore did a meta-analysis of randomised controlled trials in which these drugs plus red blood cell transfusions were compared with transfusion alone for prophylaxis or treatment of anaemia in patients with cancer. METHODS: Data for patients treated with epoetin alfa, epoetin beta, or darbepoetin alfa were obtained and analysed by independent statisticians using fixed-effects and random-effects meta-analysis. Analyses were by intention to treat. Primary endpoints were mortality during the active study period and overall survival during the longest available follow-up, irrespective of anticancer treatment, and in patients given chemotherapy. Tests for interactions were used to identify differences in effects of erythropoiesis-stimulating agents on mortality across prespecified subgroups. FINDINGS: Data from a total of 13 933 patients with cancer in 53 trials were analysed. 1530 patients died during the active study period and 4993 overall. Erythropoiesis-stimulating agents increased mortality during the active study period (combined hazard ratio [cHR] 1.17, 95% CI 1.06-1.30) and worsened overall survival (1.06, 1.00-1.12), with little heterogeneity between trials (I(2) 0%, p=0.87 for mortality during the active study period, and I(2) 7.1%, p=0.33 for overall survival). 10 441 patients on chemotherapy were enrolled in 38 trials. The cHR for mortality during the active study period was 1.10 (0.98-1.24), and 1.04 (0.97-1.11) for overall survival. There was little evidence for a difference between trials of patients given different anticancer treatments (p for interaction=0.42). INTERPRETATION: Treatment with erythropoiesis-stimulating agents in patients with cancer increased mortality during active study periods and worsened overall survival. The increased risk of death associated with treatment with these drugs should be balanced against their benefits. FUNDING: German Federal Ministry of Education and Research, Medical Faculty of University of Cologne, and Oncosuisse (Switzerland).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Monoclonal antibodies have expanded our cancer-fighting armamentarium in both the United States and Europe. While in general, monoclonal antibodies are well tolerated and do not have significant overlapping side effects with traditional cytotoxic agents, severe infusion reactions (IRs)--sometimes severe enough to be life threatening--have been reported. The pathophysiology of severe infusion reactions associated with monoclonal antibodies is poorly understood, but mechanisms are beginning to be elucidated. Geographic differences in the incidence of IRs have become apparent. Understanding the risk, recognizing the signs and symptoms, and being ready to promptly manage severe IRs are key for the clinician to avoid unnecessarily discontinuing these effective anticancer agents and prevent potentially tragic consequences for their patients. To date, clinical trials have incorporated monoclonal antibodies into combinations with standard cytotoxic regimens; it is expected that in time clinical trials will be testing promising new combinations utilizing multiple targeted agents, resulting in improved toxicity profiles and efficacy for cancer patients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Cluster randomized trials (CRTs) use as the unit of randomization clusters, which are usually defined as a collection of individuals sharing some common characteristics. Common examples of clusters include entire dental practices, hospitals, schools, school classes, villages, and towns. Additionally, several measurements (repeated measurements) taken on the same individual at different time points are also considered to be clusters. In dentistry, CRTs are applicable as patients may be treated as clusters containing several individual teeth. CRTs require certain methodological procedures during sample calculation, randomization, data analysis, and reporting, which are often ignored in dental research publications. In general, due to similarity of the observations within clusters, each individual within a cluster provides less information compared with an individual in a non-clustered trial. Therefore, clustered designs require larger sample sizes compared with non-clustered randomized designs, and special statistical analyses that account for the fact that observations within clusters are correlated. It is the purpose of this article to highlight with relevant examples the important methodological characteristics of cluster randomized designs as they may be applied in orthodontics and to explain the problems that may arise if clustered observations are erroneously treated and analysed as independent (non-clustered).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVES This study sought to study the efficacy and safety of newer-generation drug-eluting stents (DES) compared with bare-metal stents (BMS) in an appropriately powered population of patients with ST-segment elevation myocardial infarction (STEMI). BACKGROUND Among patients with STEMI, early generation DES improved efficacy but not safety compared with BMS. Newer-generation DES, everolimus-eluting stents, and biolimus A9-eluting stents, have been shown to improve clinical outcomes compared with early generation DES. METHODS Individual patient data for 2,665 STEMI patients enrolled in 2 large-scale randomized clinical trials comparing newer-generation DES with BMS were pooled: 1,326 patients received a newer-generation DES (everolimus-eluting stent or biolimus A9-eluting stent), whereas the remaining 1,329 patients received a BMS. Random-effects models were used to assess differences between the 2 groups for the device-oriented composite endpoint of cardiac death, target-vessel reinfarction, and target-lesion revascularization and the patient-oriented composite endpoint of all-cause death, any infarction, and any revascularization at 1 year. RESULTS Newer-generation DES substantially reduce the risk of the device-oriented composite endpoint compared with BMS at 1 year (relative risk [RR]: 0.58; 95% confidence interval [CI]: 0.43 to 0.79; p = 0.0004). Similarly, the risk of the patient-oriented composite endpoint was lower with newer-generation DES than BMS (RR: 0.78; 95% CI: 0.63 to 0.96; p = 0.02). Differences in favor of newer-generation DES were driven by both a lower risk of repeat revascularization of the target lesion (RR: 0.33; 95% CI: 0.20 to 0.52; p < 0.0001) and a lower risk of target-vessel infarction (RR: 0.36; 95% CI: 0.14 to 0.92; p = 0.03). Newer-generation DES also reduced the risk of definite stent thrombosis (RR: 0.35; 95% CI: 0.16 to 0.75; p = 0.006) compared with BMS. CONCLUSIONS Among patients with STEMI, newer-generation DES improve safety and efficacy compared with BMS throughout 1 year. It remains to be determined whether the differences in favor of newer-generation DES are sustained during long-term follow-up.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND The safety and efficacy of drug-eluting stents (DES) in the treatment of coronary artery disease have been assessed in several randomised trials. However, none of these trials were powered to assess the safety and efficacy of DES in women because only a small proportion of recruited participants were women. We therefore investigated the safety and efficacy of DES in female patients during long-term follow-up. METHODS We pooled patient-level data for female participants from 26 randomised trials of DES and analysed outcomes according to stent type (bare-metal stents, early-generation DES, and newer-generation DES). The primary safety endpoint was a composite of death or myocardial infarction. The secondary safety endpoint was definite or probable stent thrombosis. The primary efficacy endpoint was target-lesion revascularisation. Analysis was by intention to treat. FINDINGS Of 43,904 patients recruited in 26 trials of DES, 11,557 (26·3%) were women (mean age 67·1 years [SD 10·6]). 1108 (9·6%) women received bare-metal stents, 4171 (36·1%) early-generation DES, and 6278 (54·3%) newer-generation DES. At 3 years, estimated cumulative incidence of the composite of death or myocardial infarction occurred in 132 (12·8%) women in the bare-metal stent group, 421 (10·9%) in the early-generation DES group, and 496 (9·2%) in the newer-generation DES group (p=0·001). Definite or probable stent thrombosis occurred in 13 (1·3%), 79 (2·1%), and 66 (1·1%) women in the bare-metal stent, early-generation DES, and newer-generation DES groups, respectively (p=0·01). The use of DES was associated with a significant reduction in the 3 year rates of target-lesion revascularisation (197 [18·6%] women in the bare-metal stent group, 294 [7·8%] in the early-generation DES group, and 330 [6·3%] in the newer-generation DES group, p<0·0001). Results did not change after adjustment for baseline characteristics in the multivariable analysis. INTERPRETATION The use of DES in women is more effective and safe than is use of bare-metal stents during long-term follow-up. Newer-generation DES are associated with an improved safety profile compared with early-generation DES, and should therefore be thought of as the standard of care for percutaneous coronary revascularisation in women. FUNDING Women in Innovation Initiative of the Society of Cardiovascular Angiography and Interventions.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

AIMS To assess serially the edge vascular response (EVR) of a bioresorbable vascular scaffold (BVS) compared to a metallic everolimus-eluting stent (EES). METHODS AND RESULTS Non-serial evaluations of the Absorb BVS at one year have previously demonstrated proximal edge constrictive remodelling and distal edge changes in plaque composition with increase of the percent fibro-fatty (FF) tissue component. The 5 mm proximal and distal segments adjacent to the implanted devices were investigated serially with intravascular ultrasound (IVUS), post procedure, at six months and at two years, from the ABSORB Cohort B1 (n=45) and the SPIRIT II (n=113) trials. Twenty-two proximal and twenty-four distal edge segments were available for analysis in the ABSORB Cohort B1 trial. In the SPIRIT II trial, thirty-three proximal and forty-six distal edge segments were analysed. At the 5-mm proximal edge, the vessels treated with an Absorb BVS from post procedure to two years demonstrated a lumen loss (LL) of 6.68% (-17.33; 2.08) (p=0.027) with a trend toward plaque area increase of 7.55% (-4.68; 27.11) (p=0.06). At the 5-mm distal edge no major changes were evident at either time point. At the 5-mm proximal edge the vessels treated with a XIENCE V EES from post procedure to two years did not show any signs of LL, only plaque area decrease of 6.90% (-17.86; 4.23) (p=0.035). At the distal edge no major changes were evident with regard to either lumen area or vessel remodelling at the same time point. CONCLUSIONS The IVUS-based serial evaluation of the EVR up to two years following implantation of a bioresorbable everolimus-eluting scaffold shows a statistically significant proximal edge LL; however, this finding did not seem to have any clinical implications in the serial assessment. The upcoming imaging follow-up of the Absorb BVS at three years is anticipated to provide further information regarding the vessel wall behaviour at the edges.