920 resultados para Transit riders.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulse transit time (PTT) is a non-invasive measure of arterial compliance. It can be used to assess instantaneous blood pressure (BP) changes in continual cardiovascular measurement such as during overnight respiratory sleep studies. In these studies, periodic changes in limb position can occur randomly. However, little is known about their possible effects on PTT monitored on the various limbs. The objective of this study was to evaluate PTT differences on all four limbs during two positional changes (lowering and raising of a limb). Ten healthy adults (seven male) with a mean age of 27.0 years were recruited in this study. The results showed that the limb that underwent a positional change had significant (p < 0.05) local PTT differences when compared to its nominal baseline value, whereas PTT changes in the other remaining limbs were insignificant (p > 0.05). The mean PTT value measured from a vertically-raised limb increased by 42.7 ms, while it decreased by 28.1 ms with a half-lowered limb. The PTT differences observed during positional change can be contributed to by the complex interactions between hydrostatic pressure changes, autonomic and local autoregulation experienced in these limbs. Hence the findings herein suggest that PTT is able to reflect local circulatory responses despite changes in the position of other limbs. This can be useful in prolonged clinical observations where limb movements are expected.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional overnight polysomnography (PSG) used to determine the respiratory behaviour during sleep can be a complex and expensive procedure. Pulse transit time analysis (PTT) has shown potential to detect obstructive apnoeic and hypopnoeic events in adults. This study was undertaken to determine the potential of PTT to differentiate responses to upper airway obstruction. 103 obstructive respiratory events occurred in PSG studies performed on 11 children (10 male and 1 female, mean age 7.5years). PTT measurements were evaluated against the corresponding PSG results pre-scored by 2 blinded observers. Broadly, there were 2 types of responses. They can be either short period of rapid PTT decreases (Type 1) or prolonged but gradual PTT decreases (Type 2). Type 1 obstructive events showed a mean change of 51.77% (p

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulse Transit Time (PTT) measurement has showed potential in non-invasive monitoring of changes in blood pressure. In children, the common peripheral sites used for these studies are a finger or toe. Presently, there are no known studies conducted to investigate any possible physiologic parameters affecting PTT measurement at these sites for children. In this study, PTT values of both peripheral sites were recorded from 64 children in their sitting posture. Their mean age with standard deviation (SD) was 8.2 2.6years (ranged 3 to 12years). Subjects' peripheries path length, heart rate (HR), systolic (SBP) and diastolic blood pressure (DBP) were measured to investigate any contributions to PTT measurement. The peripheral pulse timing characteristic measured by photoplethysmography (PPG) shows a 59.5 8.5ms (or 24.8 0.4%) difference between the two peripheries (p