994 resultados para Tests accuracy
Resumo:
Catherine Comiskey CI and Hypothesis tests part 1 Hypothesis Testing  - Developing Null and Alternative Hypotheses  - Type I and Type II Errors  -  Population Mean:  S Known  - Population Mean:  S Unknown  - Population Proportion Â
Resumo:
This study was conducted to compare among the most recent generation of five screening tests licensed in Argentina, in order to evaluate which of the tests has the best sensitivity for detection of antibodies against hepatitis C virus (HCV). The tests analyzed were: Detect-HCV™ (3.0) Biochem ImmunoSystems, Canada; Hepatitis C EIA Wiener Lab., Argentina; Equipar HCV Ab, Italy; Murex HCV 4.0, UK and Serodia-HCV particles agglutination test, Japan. The results obtained showed high discrepancy between the different kits used and show that some of the tests assessed have a low sensitivity for anti-HCV detection in both chronic infections and early seroconversion, and indicate that among the commercially available kits in Argentina, Murex HCV 4.0 (UK) and Serodia-HCV particles agglutination test (Japan) have the best sensitivity for HCV screening. Although the sensitivity of the assays is the first parameter to be considered for blood screening, more studies should be carried out to assess the specificity of such assays.
Resumo:
The impact of curative radiotherapy depends mainly on the total dose delivered homogenously in the targeted volume. Nevertheless, the dose delivered to the surrounding healthy tissues may reduce the therapeutic ratio of many radiation treatments. In a same population treated in one center with the same technique, it appears that individual radiosensitivity clearly exists, namely in terms of late side effects that are in principle non-reversible. This review details the different radiobiological approaches that have been developed to better understand the mechanisms of radiation-induced late effects. We also present the possibilities of clinical use of predictive assays in the close future.
Resumo:
BACKGROUND: Occupational risks, the present nuclear threat, and the potential danger associated with nuclear power have raised concerns regarding the metabolism of plutonium in pregnant women. OBJECTIVE: We measured plutonium levels in the milk teeth of children born between 1951 and 1995 to assess the potential risk that plutonium incorporated by pregnant women might pose to the radiosensitive tissues of the fetus through placenta transfer. METHODS: We used milk teeth, whose enamel is formed during pregnancy, to investigate the transfer of plutonium from the mother's blood plasma to the fetus. We measured plutonium using sensitive sector field inductively coupled plasma mass spectrometry techniques. We compared our results with those of a previous study on strontium-90 ((90)Sr) released into the atmosphere after nuclear bomb tests. RESULTS: Results show that plutonium activity peaks in the milk teeth of children born about 10 years before the highest recorded levels of plutonium fallout. By contrast, (90)Sr, which is known to cross the placenta barrier, manifests differently in milk teeth, in accordance with (90)Sr fallout deposition as a function of time. CONCLUSIONS: These findings demonstrate that plutonium found in milk teeth is caused by fallout that was inhaled around the time the milk teeth were shed and not from any accumulation during pregnancy through placenta transfer. Thus, plutonium may not represent a radiologic risk for the radiosensitive tissues of the fetus.
Resumo:
Coagulase-negative staphylococci (CoNS) are an important cause of nosocomial bacteremia, specially in patients with indwelling devices or those submitted to invasive medical procedures. The identification of species and the accurate and rapid detection of methicillin resistance are directly dependent on the quality of the identification and susceptibility tests used, either manual or automated. The objective of this study was to evaluate the accuracy of two automated systems MicroScan and Vitek - in the identification of CoNS species and determination of susceptibility to methicillin, considering as gold standard the biochemical tests and the characterization of the mecA gene by polymerase chain reaction, respectively. MicroScan presented better results in the identification of CoNS species (accuracy of 96.8 vs 78.8%, respectively); isolates from the following species had no precise identification: Staphylococcus haemolyticus, S. simulans, and S. capitis. Both systems were similar in the characterization of methicillin resistance. The higher discrepancies for gene mec detection were observed among species other than S. epidermidis (S. hominis, S. saprophyticus, S. sciuri, S. haemolyticus, S. warneri, S. cohnii), and those with borderline MICs.
Resumo:
BACKGROUND: The AO comprehensive pediatric longbone fracture classification system describes the localization and morphology of fractures, and considers severity in 3 categories: (1) simple, (2) wedge, and (3) complex. We evaluated the reliability and accuracy of surgeons in using this rating system. MATERIAL AND METHODS: In a first validation phase, 5 experienced pediatric (orthopedic) surgeons reviewed radiographs of 267 prospectively collected pediatric fractures (agreement study A). In a second study (B), 70 surgeons of various levels of experience in 15 clinics classified 275 fractures via internet. Simple fractures comprised about 90%, 99% and 100% of diaphyseal (D), metaphyseal (M), and epiphyseal (E) fractures, respectively. RESULTS: Kappa coefficients for severity coding in D fractures were 0.82 and 0.51 in studies A and B, respectively. The median accuracy of surgeons in classifying simple fractures was above 97% in both studies but was lower, 85% (46-100), for wedge or complex D fractures. INTERPRETATION: While reliability and accuracy estimates were satisfactory as a whole, the ratings of some individual surgeons were inadequate. Our findings suggest that the classification of fracture severity in children should be done in only two categories that distinguish between simple and wedge/complex fractures.
Resumo:
This leaflet gives information on the blood tests that are normally offered and recommended at the first antenatal visit. These tests look for possible health problems that could affect the mother's health and the health of the baby. Only one sample of blood is needed to do all six tests. The tests are done by consent and this leaflet should help pregnant women make their decision.
Resumo:
The misuse of human growth hormone (hGH) in sport is deemed to be unethical and dangerous because of various adverse effects. Thus, it has been added to the International Olympic Committee list of banned substances. Until now, the very low concentration of hGH in the urine made its measurement difficult using classical methodology. Indeed, for routine diagnosis, only plasma measurements were available. However, unlike blood samples, urine is generally provided in abundant quantities and is, at present, the only body fluid allowed to be analysed in sport doping controls. A recently developed enzyme-linked immunosorbent assay (Norditest) makes it now possible, without any extraction, to measure urinary hGH (u-hGH) in a dynamic range of 2-50 ng hGH/l. In our protocol, untreated and treated non-athlete volunteers were followed. Some of them received therapeutical doses of recombinant hGH (Norditropin) for one week either intramuscularly (three increasing doses) or subcutaneously (12 i.u. every day). The u-hGH excretion after treatment showed dramatic increases of 50-100 times the basal values and returned to almost the mean normal level after 24 h. u-hGH was also measured in samples provided by the anti-doping controls at major and minor competitions. Depending on the type of efforts made during the competition, the hGH concentration in urine was dramatically increased. Insulin-like growth factor binding proteins and beta 2-microglobulins in urine and/or in blood could be necessary for the correct investigation of any hGH doping test procedure.
Resumo:
Seven swine were experimentally infected with Taenia solium eggs and blood samples from each animal were periodically collected. At the end of the experiment (t140) the animals did not show clinical aspects of cysticercosis or parasites in tongue inspection. All animals were slaughtered and cut into thin slices in searching for cysts. The number of cysts found in each animal varied from 1 to 85. Enzyme-linked immunosorbent assay (ELISA) tests for antibody (Ab) detection and for antigen (Ag) detection were performed, which presented respectively 71 and 57% of positivity. By immunoblot (IB), using 18/14(T. crassiceps Ag) or lentil-lectin-purified glycoproteins from T. solium Ag (LLGP) as Ag, five (71%) and six (86%) animals were positive, respectively. The association between Ag-ELISA with any IB (18/14 or LLGP) allowed the detection of all animals at 140 days post-experimental infection (days p.e.i.). The use of IB 18/14 combined to the Ag-ELISA allowed the detection of all animals since 70 days p.e.i., and the association between IB LLGP and Ag-ELISA allowed the detection of all animals since 112 days p.e.i. While all animals could be considered healthy by conventional screening tests, the use of immunoassays for detecting Ab and Ag showed better accuracy; therefore it would be more useful than usual clinical examination for screening cysticercosis in slightly infected pigs.
Resumo:
In Nigeria, schistosomiasis, caused predominantly by the species Schistosoma haematobium, is highly endemic in resource-poor communities. We performed a school-based survey in two rural communities in Osun State (Southwestern Nigeria) and assessed macrohaematuria, microhaematuria and proteinuria as indirect indicators for the presence of disease. Urine samples were inspected macroscopically for haematuria and screened for microhaematuria and proteinuria using urine reagent strips. The microscopic examination of schistosome eggs was used as the gold standard for diagnosis. In total, 447 schoolchildren were included in this study and had a 51% prevalence of urinary schistosomiasis. The sensitivity of microhaematuria (68%) and proteinuria (53%) for infection with S. haematobium was relatively low. In patients with a heavy infection (>500 eggs/10 mL), the sensitivity of microhaematuria was high (95%). When the presence of macrohaematuria and the concomitant presence of microhaematuria and proteinuria were combined, it revealed a sensitivity of 63%, a specificity of 93% and a positive predictive value of 91%. Macrohaematuria also showed high specificity (96%) and a positive predictive value of 92%, while sensitivity was < 50%. These data show that combining urine reagent strip tests (presence of proteinuria and microhaematuria) and information on macrohaematuria increased the accuracy of the rapid diagnosis of urinary schistosomiasis in an endemic rural West African setting. This simple approach can be used to increase the quality of monitoring of schistosomiasis in schoolchildren.
Resumo:
Significant advances were made in the diagnosis of filariasis in the 1990s with the emergence of three new alternative tools: ultrasound and tests to detect circulating antigen using two monoclonal antibodies, Og4C3 and AD12-ICT-card. This study aimed to identify which of these methods is the most sensitive for diagnosis of infection. A total of 256 individuals, all male and carrying microfilariae (1-15,679 MF/mL), diagnosed by nocturnal venous blood samples, were tested by all three techniques. The tests for circulating filarial antigen concurred 100% and correctly identified 246/256 (96.69%) of the positive individuals, while ultrasound detected only 186/256 (73.44%). Of the circulating antigen tests, ICT-card was the most convenient method for identification of Wuchereria bancrofti carriers. It was easy to perform, practical and quick.
Resumo:
OBJECTIVES: To test whether the Global Positioning System (GPS) could be potentially useful to assess the velocity of walking and running in humans. SUBJECT: A young man was equipped with a GPS receptor while walking running and cycling at various velocity on an athletic track. The speed of displacement assessed by GPS, was compared to that directly measured by chronometry (76 tests). RESULTS: In walking and running conditions (from 2-20 km/h) as well as cycling conditions (from 20-40 km/h), there was a significant relationship between the speed assessed by GPS and that actually measured (r = 0.99, P < 0.0001) with little bias in the prediction of velocity. The overall error of prediction (s.d. of difference) averaged +/-0.8 km/h. CONCLUSION: The GPS technique appears very promising for speed assessment although the relative accuracy at walking speed is still insufficient for research purposes. It may be improved by using differential GPS measurement.