960 resultados para Tandem mass spectrometry Nitroxyl radical Alkoxyamine Bond homolysis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

An on-line dialysis flow system coupled to inductively coupled plasma mass spectrometry to determine trace elements in serum samples by isotope dilution is presented. Isotope dilution was performed on samples incubated with enriched Cu-65, Zn-66, Se-77 and Pb-206 for 24 h at 36degreesC prior to dialysis to quantified total element concentrations. The sample and acceptor solutions flowed through the dialysis unit with cellophane membrane placed in between the compartments. The serum sample (1 mL) was left to recycle in a closed path while the acceptor solution was continuously pumped along the dialyzer channel and through a cationic AG50W X-8 resin column. After 10 min, around 70% of Na, K and Cl migrate from the sample. Three replicate injections of 0.1 mL were performed for the clean sample after each separation step. The on-line coupling of the dialyzer to ICP-MS allowed isotope dilution for total element determination either in the cleaned sample or by eluting the cations retained in the resin to be carried out. Results demonstrated no matrix effects from alkaline elements or spectral interference from ArNa+ on Cu-63, ArCl+ on Se-77 and (SO2+)-S-34 on Zn-66. The precision of isotope ratio measurements for Cu and Zn was around 1% and for Se and Pb was around 2.5%. The values found for the reference serum sample IMEP-17 were in good agreement with the certified values for Cu, Zn and Se.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An analytical procedure for direct introduction of biodiesel samples into an inductively coupled plasma mass spectrometer (ICP-MS) by using microemulsion for sample preparation was developed here. Cadmium, Co, Cu, Mn, Ni, Pb, Ti, and Zn were determined in biodiesel microemulsified samples prepared from different oleaginous sources (African palm, castor beans, palm, soybeans and an unknown oleaginous). Microemulsions were prepared using 0.25 mL Triton X-100, 0.25 mL 20% v v(-1) HNO(3), 0.50 mL biodiesel sample and 4.0 mL n-propanol. Argon-oxygen mixture was added to the plasma as auxiliary gas for correcting matrix effects caused by the high carbon load due to biodiesel microemulsions. The oxygen gas flow rate was set in 37.5 mL min(-1). The accuracy of the developed procedure was evaluated by applying addition-recovery experiments for biodiesel samples from different sources. Recoveries varied from 76.5 to 116.2% for all analytes but Zn in castor beans biodiesel sample (65.0 to 76.2%). Recoveries lower than 86.6% were obtained for palm biodiesel sample, probably due to matrix effects. Detection limits calculated by using oxygen in the composition of the auxiliary gas added to the plasma were higher than those calculated without using it, probably due to the highest formation of oxides. Despite oxides formation, best analytical performance was reached by using oxygen as auxiliary gas and by proper correction of transport interferences. The developed procedure based on microemulsion formation was suitable for direct introduction of biodiesel samples in ICP-MS. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two highly sensitive and selective methods based on gas chromatography coupled to mass spectrometry (GC-MS) in the selected ion monitoring (SIM) mode have been developed for the quantification of 2,6-dichlorophenol (2,6-DCP), a sex pheromone of the tick females of Anocentor nitens. Standard addition method and calibration curve techniques using 5-bromine-4-hydroxy-3- methoxybenzaldehyde (5-BrV) as internal standard (IS) afforded detection limit of 0.1ngml-1. The calibration curve was linear over the concentration range from 0.5 to 500ngml-1 for 2,6-DCP. Results show that the concentration range of sex pheromone in the extracts samples was 1.08-10.35ngml-1. The methods developed provided reliable procedures to determine amounts of 2,6-DCP present in ticks. © 2003 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A rational and selective method using on-line high-performance liquid chromatography (HPLC) coupled with electrospray quadrupole time-of-flight tandem mass spectrometry (ESI-QToF-MS/MS) was established for the dereplication of phenolic derivatives from Qualea grandiflora and Qualea cordata. The selection of the extracts was based on the antioxidant capacity measured by in vitro DPPH assay. The HPLC-ESI-QToF-MS/MS analysis was conducted by on-flow detection, using high-resolution mass/ratio ions as well as collision induced MS/MS experiments for selected protonated ions. The dereplication of the EtOAc fraction from the hydro alcohol extract from the stem bark of Q. grandiflora allowed the detection of the flavonoids: 3',4',5',5,6,7-hexahydroxy- 8 methylflavanone, 8-methyl-naringenine and 3',7-dimethoxy-8 methyl-4',5,7- trihydroxyflavanone, as well as a benzophenone derivatives: bis(4,6-dimethoxy-2- hydroxy-3-methylphenyl)- metanone, 3',4'-dimethoxy-8-methyl-5,6,7 trihydroxyflavanone, 7-methoxy-6-methyl- 3',4',5 trihydroxyflavanone, 6,8-dimethyl-3' methoxy-4',5,7 trihydroxyflavanone and 3',5'-dimethoxy-6,8- dimethyl-4',5,7 trihydroxyflavanone were detected in the EtOAc fraction from the hydro-alcohol extract from the leaves of Q. cordata. © 2013 Sociedade Brasileira de Química.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In pre-implantation embryos, lipids play key roles in determining viability, cryopreservation and implantation properties, but often their analysis is analytically challenging because of the few picograms of analytes present in each of them. Matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) allows obtaining individual phospholipid profiles of these microscopic organisms. This technique is sensitive enough to enable analysis of individual intact embryos and monitoring the changes in membrane lipid composition in the early stages of development serving as screening method for studies of biology and biotechnologies of reproduction. This article introduces an improved, more comprehensive MALDI-MS lipid fingerprinting approach that considerably increases the lipid information obtained from a single embryo. Using bovine embryos as a biological model, we have also tested optimal sample storage and handling conditions before the MALDI-MS analysis. Improved information at the molecular level is provided by the use of a binary matrix that enables phosphatidylcholines, sphingomyelins, phosphatidylserines, phosphatidylinositols and phosphoethanolamines to be detected via MALDI(±)-MS in both the positive and negative ion modes. An optimal MALDI-MS protocol for lipidomic monitoring of a single intact embryo is therefore reported with potential applications in human and animal reproduction, cell development and stem cell research. Copyright © 2013 John Wiley & Sons, Ltd. Copyright © 2013 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Gas chromatography with mass spectrometry is frequently used for the quantification of many classes of substances, including alkylphenols. Alkylphenol polyethoxylates are nonionic surfactants used in a wide variety of industrial and consumer applications. Alkylphenol polyethoxylates can degrade to alkylphenols, which are endocrine disruptors. In analytical validation procedures, the most common parameters studied are the detection and quantification limits, linearity, and recovery; however, the matrix effects are sometimes neglected. Although some investigators have evaluated matrix effects, there is no consensus on how to evaluate them during method validation. In this study, the matrix effects of alkylphenol polyethoxylates (nonylphenol monoethoxylate, nonylphenol diethoxylate, octylphenol monoethoxylate, octylphenol diethoxylate) and alkylphenols (nonylphenol and octylphenol) were studied using solid phase extraction and gas chromatography-mass spectrometry analysis. For alkylphenol polyethoxylates, the matrix effects ranged from 16 to 4692%, whereas for alkylphenols (nonylphenol and octylphenol), the effects were insignificant. Therefore, constructing an analytical curve in the matrix for alkylphenol polyethoxylates is essential. © 2013 Copyright Taylor and Francis Group, LLC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)