966 resultados para Swimming pools -- Air conditioning
Resumo:
Heating, ventilation, air conditioning (HVAC) systems are significant consumers of energy, however building management systems do not typically operate them in accordance with occupant movements. Due to the delayed response of HVAC systems, prediction of occupant locations is necessary to maximize energy efficiency. We present an approach to occupant location prediction based on association rule mining, allowing prediction based on historical occupant locations. Association rule mining is a machine learning technique designed to find any correlations which exist in a given dataset. Occupant location datasets have a number of properties which differentiate them from the market basket datasets that association rule mining was originally designed for. This thesis adapts the approach to suit such datasets, focusing the rule mining process on patterns which are useful for location prediction. This approach, named OccApriori, allows for the prediction of occupants’ next locations as well as their locations further in the future, and can take into account any available data, for example the day of the week, the recent movements of the occupant, and timetable data. By integrating an existing extension of association rule mining into the approach, it is able to make predictions based on general classes of locations as well as specific locations.
Resumo:
Coal ignited the industrial revolution. An organic sedimentary rock that energized the globe, transforming cities, landscapes and societies for generations, the importance of ‘King Coal’ to the development and consolidation of modernity has been well-recognised. And yet, as a critical factor in the production of modern architecture, coal—as well as other forms of energy—has been mostly overlooked.
From Appalachia to Lanarkshire, from the pits of northern France, Belgium and the Ruhr valley, to the monumental opencast excavations of Russia, China, Africa and Australia, mining operations have altered the immediate social and physical landscapes of coal-rich areas. But in contrast to its own underground conditions of production, the winning of coal, especially in the twentieth-century, has produced conspicuously enlightened and humane approaches to architecture and urbanism. In the twentieth century, educational buildings, holiday camps, hospitals, swimming pools, convalescent homes and housing prevailed alongside model collieries in mining settlements and areas connected to them. In 1930s Britain, pit head baths—funded by a levy on each ton produced—were often built in the International Style. Many won praise for architectural merit, appearing in Nicholas Pevsner’s guides to the buildings of England alongside cathedrals, village manors and Masonic halls as testimonies to the public good.
The deep relationships between coal and modernity, and the expressions of architecture it has articulated, in the collieries from which it was hewn, the landscape and towns it shaped, and the power stations and other infrastructure where it was used, offer innumerable opportunities to explore how coal produced architectures which embodied and expressed both social and technological conditions. While proposals on coal are preferred, we also welcome papers that interrogate the complexity, heterogeneity and hybridity of other forms of energy production and how these have also interceded into architectural form at a range of scales.
Resumo:
Phase change problems arise in many practical applications such as air-conditioning and refrigeration, thermal energy storage systems and thermal management of electronic devices. The physical phenomenon in such applications are complex and are often difficult to be studied in detail with the help of only experimental techniques. The efforts to improve computational techniques for analyzing two-phase flow problems with phase change are therefore gaining momentum. The development of numerical methods for multiphase flow has been motivated generally by the need to account more accurately for (a) large topological changes such as phase breakup and merging, (b) sharp representation of the interface and its discontinuous properties and (c) accurate and mass conserving motion of the interface. In addition to these considerations, numerical simulation of multiphase flow with phase change introduces additional challenges related to discontinuities in the velocity and the temperature fields. Moreover, the velocity field is no longer divergence free. For phase change problems, the focus of developmental efforts has thus been on numerically attaining a proper conservation of energy across the interface in addition to the accurate treatment of fluxes of mass and momentum conservation as well as the associated interface advection. Among the initial efforts related to the simulation of bubble growth in film boiling applications the work in \cite{Welch1995} was based on the interface tracking method using a moving unstructured mesh. That study considered moderate interfacial deformations. A similar problem was subsequently studied using moving, boundary fitted grids \cite{Son1997}, again for regimes of relatively small topological changes. A hybrid interface tracking method with a moving interface grid overlapping a static Eulerian grid was developed \cite{Juric1998} for the computation of a range of phase change problems including, three-dimensional film boiling \cite{esmaeeli2004computations}, multimode two-dimensional pool boiling \cite{Esmaeeli2004} and film boiling on horizontal cylinders \cite{Esmaeeli2004a}. The handling of interface merging and pinch off however remains a challenge with methods that explicitly track the interface. As large topological changes are crucial for phase change problems, attention has turned in recent years to front capturing methods utilizing implicit interfaces that are more effective in treating complex interface deformations. The VOF (Volume of Fluid) method was adopted in \cite{Welch2000} to simulate the one-dimensional Stefan problem and the two-dimensional film boiling problem. The approach employed a specific model for mass transfer across the interface involving a mass source term within cells containing the interface. This VOF based approach was further coupled with the level set method in \cite{Son1998}, employing a smeared-out Heaviside function to avoid the numerical instability related to the source term. The coupled level set, volume of fluid method and the diffused interface approach was used for film boiling with water and R134a at the near critical pressure condition \cite{Tomar2005}. The effect of superheat and saturation pressure on the frequency of bubble formation were analyzed with this approach. The work in \cite{Gibou2007} used the ghost fluid and the level set methods for phase change simulations. A similar approach was adopted in \cite{Son2008} to study various boiling problems including three-dimensional film boiling on a horizontal cylinder, nucleate boiling in microcavity \cite{lee2010numerical} and flow boiling in a finned microchannel \cite{lee2012direct}. The work in \cite{tanguy2007level} also used the ghost fluid method and proposed an improved algorithm based on enforcing continuity and divergence-free condition for the extended velocity field. The work in \cite{sato2013sharp} employed a multiphase model based on volume fraction with interface sharpening scheme and derived a phase change model based on local interface area and mass flux. Among the front capturing methods, sharp interface methods have been found to be particularly effective both for implementing sharp jumps and for resolving the interfacial velocity field. However, sharp velocity jumps render the solution susceptible to erroneous oscillations in pressure and also lead to spurious interface velocities. To implement phase change, the work in \cite{Hardt2008} employed point mass source terms derived from a physical basis for the evaporating mass flux. To avoid numerical instability, the authors smeared the mass source by solving a pseudo time-step diffusion equation. This measure however led to mass conservation issues due to non-symmetric integration over the distributed mass source region. The problem of spurious pressure oscillations related to point mass sources was also investigated by \cite{Schlottke2008}. Although their method is based on the VOF, the large pressure peaks associated with sharp mass source was observed to be similar to that for the interface tracking method. Such spurious fluctuation in pressure are essentially undesirable because the effect is globally transmitted in incompressible flow. Hence, the pressure field formation due to phase change need to be implemented with greater accuracy than is reported in current literature. The accuracy of interface advection in the presence of interfacial mass flux (mass flux conservation) has been discussed in \cite{tanguy2007level,tanguy2014benchmarks}. The authors found that the method of extending one phase velocity to entire domain suggested by Nguyen et al. in \cite{nguyen2001boundary} suffers from a lack of mass flux conservation when the density difference is high. To improve the solution, the authors impose a divergence-free condition for the extended velocity field by solving a constant coefficient Poisson equation. The approach has shown good results with enclosed bubble or droplet but is not general for more complex flow and requires additional solution of the linear system of equations. In current thesis, an improved approach that addresses both the numerical oscillation of pressure and the spurious interface velocity field is presented by featuring (i) continuous velocity and density fields within a thin interfacial region and (ii) temporal velocity correction steps to avoid unphysical pressure source term. Also I propose a general (iii) mass flux projection correction for improved mass flux conservation. The pressure and the temperature gradient jump condition are treated sharply. A series of one-dimensional and two-dimensional problems are solved to verify the performance of the new algorithm. Two-dimensional and cylindrical film boiling problems are also demonstrated and show good qualitative agreement with the experimental observations and heat transfer correlations. Finally, a study on Taylor bubble flow with heat transfer and phase change in a small vertical tube in axisymmetric coordinates is carried out using the new multiphase, phase change method.
Resumo:
Natural air ventilation is the most import passive strategy to provide thermal comfort in hot and humid climates and a significant low energy strategy. However, the natural ventilated building requires more attention with the architectural design than a conventional building with air conditioning systems, and the results are less reliable. Therefore, this thesis focuses on softwares and methods to predict the natural ventilation performance from the point of view of the architect, with limited resource and knowledge of fluid mechanics. A typical prefabricated building was modelled due to its simplified geometry, low cost and occurrence at the local campus. Firstly, the study emphasized the use of computational fluid dynamics (CFD) software, to simulate the air flow outside and inside the building. A series of approaches were developed to make the simulations possible, compromising the results fidelity. Secondly, the results of CFD simulations were used as the input of an energy tool, to simulate the thermal performance under different rates of air renew. Thirdly, the results of temperature were assessed in terms of thermal comfort. Complementary simulations were carried out to detail the analyses. The results show the potentialities of these tools. However the discussions concerning the simplifications of the approaches, the limitations of the tools and the level of knowledge of the average architect are the major contribution of this study
Resumo:
The main issues related to water conservation in urban centers are the increase in water supply cost, demand growth, pollution and differences in the distribution of water resources. Water conservation, the controlled and efficient use of water, includes both measures as reasonable means of water reuse. Thus, conservation practices are an effective way to meet demand and supply water to new activities and users without jeopardizing the supplying water bodies and preserving the natural environment. This study aims to examine the water management of a shopping mall and the use of rainwater harvesting combined with greywater reuse. For buildings in general, water loss is common due to leaks in the hydraulic and restroom equipment. These losses, which are caused by a high volume of water used and wasted in the system, are often the result of design errors, incorrect maintenance procedures and users' bad habits In southern Brazil, where there is rainfall almost all year long, water shortages occasionally occur, particularly in some winter mouths. One difficulty that appears on rainwater studies is the proper determination of rainwater volume that can be used to address water supply systems. In this work, the simulation method was used to determine this volume. Thus, simulations with the following variables: rainfall, catchment area and water consumption were performed. For mall's hydraulic systems, segmented alternatives are adopted. That is, focusing on the use of rainwater or greywater reuse. Other alternatives of effluent reuse have been slightly discussed due to sanitary issues, those are effluents from toilets and kitchen sinks. The adoption of greywater may be feasible if there is a significant flow of greywater to comply water demand for toilet flushing. The inspections made in this study found that the quantity of sinks was insufficient to supply an adequate amount of water to toilets and urinals. The greywater reuse system was found to be infeasible in terms of demand and supply of water. Conversely, the rainwater harvesting system was entirely feasible and easily supplied water to all restrooms and contributed to the cooling of the air conditioning system with a short payback period. One of the challenges of this work was the need to compare the actual water consumption with a water consumption parameter used in buildings. Thus, a method that addresses the generation of specific consumption indexes for specific activity (like a mall) was used. The water consumption indices showed that this mall has a satisfactory water management program.
Resumo:
This master thesis aims to assess the influence of the design decisions on the energy building performance of hotels. The research is based on the integration of field study and computer simulation. Firstly, a detailed field study is carried out to identify the characteristics of hotels in Natal, Rio Grande do Norte. The items assessed are occupancies, light and equipment densities, types of air conditioning, total and monthly energy consumption, among others. A second and more comprehensive field study is carried out to identify the range of occurrence of architectural variables, with a larger number of buildings. A base case is modelled in VisualDOE, based on the first field study. Then, a first set of simulations are run to explore the sensitivity of the variables on the energy consumption. The results analyses were the base of a second set of simulations, which combined the most influential variables. The results of 384 models were assessed, and the impacts of design decisions were quantified. The study discusses tendencies and recommendations, as well as the methods advantages and disadvantages
Resumo:
In recent years, we have seen an improvement of existing facilities in dwellings in Portugal. Within the heat pumps systems, there is a special type known as direct expansion heat pump assisted by Solar Collector (DX-SAHP). It was calculate the SPF indicator for 30 regions of Portugal. It was analyses the potential of reductions of CO2 and primary energy use for the retrofitting of DHW preparation systems. It was found that the performances of this type of equipment are benefiting from the Portuguese climate conditions, especially in the South and in the Autonomous Regions. Best SPF was obtained for Beja. It was found in all regions of the high potential for reducing CO2 emissions and verifying a potential significant reduction of primary energy consumption.
Resumo:
Buildings and the whole built environment are in a key role when societies are mitigating climate change and adapting to its consequences. More than 50% of the existing residential buildings in EU-25 were built before 1970. Thus, these buildings are of significant importance in reducing energy consumption and CO2 emissions. The existence of more nearly zero energy buildings (nZEB) is a possible solution for this problem. This study aims to analyze the application of the nZEB methodology in the retrofitting of a typical Portuguese dwelling build in 1950. It was shown that the primary energy used can be reduced to a very low value (11,95 kWhep/m2.y) in comparison with the reference consumption (69,15 kWhep/m2.y), with the application of the best construction techniques together with the use of energy from on-site renewable sources.
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica com Especialização em Energia, Climatização e Refrigeração
Resumo:
The off-cycle refrigerant mass migration has a direct influence on the on-cycle performance since compressor energy is necessary to redistribute the refrigerant mass. No studies, as of today, are available in the open literature which experimentally measured the lubricant migration within a refrigeration system during cycling or stop/start transients. Therefore, experimental procedures measuring the refrigerant and lubricant migration through the major components of a refrigeration system during stop/start transients were developed and implemented. Results identifying the underlying physics are presented. The refrigerant and lubricant migration of an R134a automotive A/C system-utilizing a fixed orifice tube, minichannel condenser, plate and fin evaporator, U-tube type accumulator and fixed displacement compressor-was measured across five sections divided by ball valves. Using the Quick-Closing Valve Technique (QCVT) combined with the Remove and Weigh Technique (RWT) using liquid nitrogen as the condensing agent resulted in a measurement uncertainty of 0.4 percent regarding the total refrigerant mass in the system. The determination of the lubricant mass distribution was achieved by employing three different techniques-Remove and Weigh, Mix and Sample, and Flushing. To employ the Mix and Sample Technique a device-called the Mix and Sample Device-was built. A method to separate the refrigerant and lubricant was developed with an accuracy-after separation-of 0.04 grams of refrigerant left in the lubricant. When applying the three techniques, the total amount of lubricant mass in the system was determined to within two percent. The combination of measurement results-infrared photography and high speed and real time videography-provide unprecedented insight into the mechanisms of refrigerant and lubricant migration during stop-start operation. During the compressor stop period, the primary refrigerant mass migration is caused by, and follows, the diminishing pressure difference across the expansion device. The secondary refrigerant migration is caused by a pressure gradient as a result of thermal nonequilibrium within the system and causes only vapor phase refrigerant migration. Lubricant migration is proportional to the refrigerant mass during the primary refrigerant mass migration. During the secondary refrigerant mass migration lubricant is not migrating. The start-up refrigerant mass migration is caused by an imbalance of the refrigerant mass flow rates across the compressor and expansion device. The higher compressor refrigerant mass flow rate was a result of the entrainment of foam into the U-tube of the accumulator. The lubricant mass migration during the start-up was not proportional to the refrigerant mass migration. The presence of water condensate on the evaporator affected the refrigerant mass migration during the compressor stop period. Caused by an evaporative cooling effect the evaporator held 56 percent of the total refrigerant mass in the system after three minutes of compressor stop time-compared to 25 percent when no water condensate was present on the evaporator coil. Foam entrainment led to a faster lubricant and refrigerant mass migration out of the accumulator than liquid entrainment through the hole at the bottom of the U-tube. The latter was observed for when water condensate was present on the evaporator coil because-as a result of the higher amount of refrigerant mass in the evaporator before start-up-the entrainment of foam into the U-tube of the accumulator ceased before the steady state refrigerant mass distribution was reached.
Resumo:
A battery powered air-conditioning device was developed to provide an improved thermal comfort level for individuals in inadequately cooled environments. This device is a battery powered air-conditioning system with the phase change material (PCM) for heat storage. The condenser heat is stored in the PCM during the cooling operation and is discharged while the battery is charged by using the vapor compression cycle as a thermosiphon loop. The main focus of the current research was on the development of the cooling system. The cooling capacity of the vapor compression cycle measured was 165.6 W with system COP at 2.85. It was able to provide 2 hours cooling without discharging heat to the ambient. The PCM was recharged in nearly 8 hours under thermosiphon mode.
Resumo:
Life Cycle Climate Performance (LCCP) is an evaluation method by which heating, ventilation, air conditioning and refrigeration systems can be evaluated for their global warming impact over the course of their complete life cycle. LCCP is more inclusive than previous metrics such as Total Equivalent Warming Impact. It is calculated as the sum of direct and indirect emissions generated over the lifetime of the system “from cradle to grave”. Direct emissions include all effects from the release of refrigerants into the atmosphere during the lifetime of the system. This includes annual leakage and losses during the disposal of the unit. The indirect emissions include emissions from the energy consumption during manufacturing process, lifetime operation, and disposal of the system. This thesis proposes a standardized approach to the use of LCCP and traceable data sources for all aspects of the calculation. An equation is proposed that unifies the efforts of previous researchers. Data sources are recommended for average values for all LCCP inputs. A residential heat pump sample problem is presented illustrating the methodology. The heat pump is evaluated at five U.S. locations in different climate zones. An excel tool was developed for residential heat pumps using the proposed method. The primary factor in the LCCP calculation is the energy consumption of the system. The effects of advanced vapor compression cycles are then investigated for heat pump applications. Advanced cycle options attempt to reduce the energy consumption in various ways. There are three categories of advanced cycle options: subcooling cycles, expansion loss recovery cycles and multi-stage cycles. The cycles selected for research are the suction line heat exchanger cycle, the expander cycle, the ejector cycle, and the vapor injection cycle. The cycles are modeled using Engineering Equation Solver and the results are applied to the LCCP methodology. The expander cycle, ejector cycle and vapor injection cycle are effective in reducing LCCP of a residential heat pump by 5.6%, 8.2% and 10.5%, respectively in Phoenix, AZ. The advanced cycles are evaluated with the use of low GWP refrigerants and are capable of reducing the LCCP of a residential heat by 13.7%, 16.3% and 18.6% using a refrigerant with a GWP of 10. To meet the U.S. Department of Energy’s goal of reducing residential energy use by 40% by 2025 with a proportional reduction in all other categories of residential energy consumption, a reduction in the energy consumption of a residential heat pump of 34.8% with a refrigerant GWP of 10 for Phoenix, AZ is necessary. A combination of advanced cycle, control options and low GWP refrigerants are necessary to meet this goal.
Resumo:
This book is a synthesizing reflection on the Holocaust commemoration, in which space becomes a starting point for discussion. The author understands space primarily as an amalgam of physical and social components, where various commemorative processes may occur. The first part of the book draws attention to the material aspect of space, which determines its character and function. Material culture has been a long ignored and depreciated dimension of human culture in the humanities and social sciences, because it was perceived as passive and fully controlled by human will, and therefore insignificant in the course of social and historical processes. An example of the Nazi system perfectly illustrates how important were the restrictions and prohibitions on the usage of mundane objects, and in general, the whole material culture in relation to macro and micro space management — the state, cities, neighborhoods and houses, but also parks and swimming pools, factories and offices or shops and theaters. The importance of things and space was also clearly visible in exploitative policies present in overcrowded ghettos and concentration and death camps. For this very reason, when we study spatial forms of Holocaust commemoration, it should be acknowledged that the first traces, proofs and mementoes of the murdered were their things. The first "monuments" showing the enormity of the destruction are thus primarily gigantic piles of objects — shoes, glasses, toys, clothes, suitcases, toothbrushes, etc., which together with the extensive camps’ space try to recall the scale of a crime impossible to understand or imagine. The first chapter shows the importance of introducing the material dimension in thinking about space and commemoration, and it ends with a question about one of the key concepts for the book, a monument, which can be understood as both object (singular or plural) and architecture (sculptures, buildings, highways). However, the term monument tends to be used rather in a later and traditional sense, as an architectural, figurative form commemorating the heroic deeds, carved in stone or cast in bronze. Therefore, the next chapter reconstructs this narrower line of thinking, together with a discussion about what form a monument commemorating a subject as delicate and sensitive as the Holocaust should take on. This leads to an idea of the counter-monument, the concept which was supposed to be the answer to the mentioned representational dilemma on the one hand, and which would disassociate it from the Nazi’s traditional monuments on the other hand. This chapter clarifies the counter-monument definition and explains the misunderstandings and confusions generated on the basis of this concept by following the dynamics of the new commemorative form and by investigating monuments from the ‘80s and ‘90s erected in Germany. In the next chapter, I examine various forms of the Holocaust commemoration in Berlin, a city famous for its bold, monumental, and even controversial projects. We find among them the entire spectrum of memorials – big, monumental, and abstract forms, like Peter Eisenman’s Memorial to the Murdered Jews of Europe or Daniel Liebeskind’s Jewish Museum Berlin; flat, invisible, and employing the idea of emptiness, like Christian Boltanski’s Missing House or Micha Ullman’s Book Burning Memorial; the dispersed and decentralized, like Renata Stih and Frieder Schnock’s Memory Places or Gunter Demnig’s Stumbling Blocks. I enrich descriptions of the monuments by signaling at this point their second, extended life, which manifests itself in the alternative modes of (mis)use, consisting of various social activities or artistic performances. The formal wealth of the outlined projects creates a wide panorama of possible solutions to the Holocaust commemoration problems. However, the discussions accompanying the building of monuments and their "future life" after realization emphasize the importance of the social component that permeates the biography of the monument, and therefore significantly influences its foreseen design. The book also addresses the relationship of space, place and memory in a specific situation, when commemoration is performed secretly or remains as unrealized potential. Although place is the most common space associated with memory, today the nature of this relationship changes, and is what indicates popularity and employment of such terms as Marc Augé’s non-places or Pierre Nora’s site of memory. I include and develop these concepts about space and memory in my reflections to describe qualitatively different phenomena occurring in Central and Eastern European countries. These are unsettling places in rural areas like glades or parking lots, markets and playgrounds in urban settings. I link them to the post-war time and modernization processes and call them sites of non-memory and non-sites of memory. Another part of the book deals with a completely different form of commemoration called Mystery of memory. Grodzka Gate - NN Theatre in Lublin initiated it in 2000 and as a form it situates itself closer to the art of theater than architecture. Real spaces and places of everyday interactions become a stage for these performances, such as the “Jewish town” in Lublin or the Majdanek concentration camp. The minimalist scenography modifies space and reveals its previously unseen dimensions, while the actors — residents and people especially related to places like survivors and Righteous Among the Nations — are involved in the course of the show thanks to various rituals and symbolic gestures. The performance should be distinguished from social actions, because it incorporates tools known from religious rituals and art, which together saturate the mystery of memory with an aura of uniqueness. The last discussed commemoration mode takes the form of exposition space. I examine an exhibition concerning the fate of the incarcerated children presented in one of the barracks of the Majdanek State Museum in Lublin. The Primer – Children in Majdanek Camp is unique for several reasons. First, because even though it is exhibited in the camp barrack, it uses a completely different filter to tell the story of the camp in comparison to the exhibitions in the rest of the barracks. For this reason, one experiences immersing oneself in all subsequent levels of space and narrative accompanying them – at first, in a general narrative about the camp, and later in a specifically arranged space marked by children’s experiences, their language and thinking, and hence formed in a way more accessible for younger visitors. Second, the exhibition resigns from didacticism and distancing descriptions, and takes an advantage of eyewitnesses and survivors’ testimonies instead. Third, the exhibition space evokes an aura of strangeness similar to a fairy tale or a dream. It is accomplished thanks to the arrangement of various, usually highly symbolic material objects, and by favoring the fragrance and phonic sensations, movement, while belittling visual stimulations. The exhibition creates an impression of a place open to thinking and experiencing, and functions as an asylum, a radically different form to its camp surrounding characterized by a more overwhelming and austere space.
Resumo:
Dissertação (mestrado)—Universidade de Brasília, Faculdade UnB Gama, Faculdade de Tecnologia, Programa de Pós-graduação em Integridade de Materiais da Engenharia, 2016.