974 resultados para Spatial Resolution
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Agronomia - FEIS
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A novel AC Biosusceptometry (ACB) system with thirteen sensors it was implemented and characterized in vitro using magnetic phantoms. The system presenting coils in a coaxial arrangement with one pair of excitation coil outside and thirteen pairs of detection coils inside. A first-order gradiometric configuration was utilized for optimal detection of magnetic signals. Several physical parameters such as baseline, number of turns, excitation field and diameters were studied for improvement of the signal/noise ratio. This system exhibits an enhanced sensitivity and spatial resolution, due to the higher density of sensors/area. In the future those characteristics will turn possible to obtain images of magnetic marker or tracer in the gastrointestinal tract focusing on physiological and pharmaceutical studies. ACB emerged due to its interesting nature, noninvasiveness and low cost to investigate gastrointestinal parameters and this system can contribute for more accurate interpretation of biomedical signals and images
Resumo:
The best way to detect breast cancer is by screening mammography. The mammography equipments are dedicated and require a rigorous quality control in order to have a good quality image and to early detect this disease. The digital equipment is relatively new in the market and there isn’t a national rule for quality control for several types of digital detectors. This study has proposed to compare two different tests manuals for quality control provided by the manufacturers of digital mammography equipments, and also compare them to the “European guidelines for quality assurance in breast cancer screening and diagnosis “(2006). The studied equipments were: Senographe 2000D from General Electric (GE) and the Hologic Selenia Lorad. Both were digital mammography equipments, the GE unit presents an indirect digital system and the other presents a direct digital system. Physical parameters of the image have been studied, such as spatial resolution, contrast resolution, noise, signal-tonoise ratio, contrast-to-noise ratio and modulation transfer function. After that, a study of the importance of quality control and the requirement to implement a Quality Assurance Program has been done. One data collection was done to compare those manual, it was done by checking which tests are indicated and the minimum frequency which they should be conducted in accordance with each manufacturer. The tests were performed by different methodologies and the results were compared. The examined tests were: the breast entrance skin dose, mean glandular dose, contrast-to-noise ratio, signal-to-noise ratio, automatic exposure control and automatic control of density, modulation transfer function, equipment resolution, homogeneity and ghost
Resumo:
The metropolitan region of São Paulo is the most populous of the country, this happens because of its great importance in the national economy and the job opportunities that are offered to the population. These factors result in intense population growth and urban expansion, reaching some non-habitable places of the metropolis, as areas of pipelines, which are very important for the transportation of natural gas, oil and its derivatives. Before the population growth of the region, these sites were unoccupied, do not presenting problems for the population. However, with the disorderly occupation is generated great anthropogenic pressure on the pipeline stitches, causing risks to people who are around them. Therefore it is extremely important to monitor the strip of pipelines through products and techniques of remote sensing and geoprocessing, enabling, through high spatial resolution images, identification of objects or phenomena that occur on Earth's surface that can alter the functioning and safety of pipelines. Therefore, this study aims to monitor a stretch of the area of the pipeline mesh GASPAL/OSVAT and Capuava Refinery (RECAP), located on the outskirts of the metropolitan area of São Paulo in the city of Mauá, who suffer great human pressure, proving thus the techniques of remote sensing and geographic information system (GIS) as effective tools for monitoring phenomena occurred in urban areas of great complexity. The monitoring was done by object-based classification applied in orbital images Ikonos II and RapidEye, of high spatial resolution and, image processing, detection of objects, segmentation, classification and editing were developed through the eCognition and ArcGis softwares. To determine the statistical accuracy of the mapping of the land cover of the stretch of pipeline in Maua, the results were analyzed by error matrix... (Complete abstract click electronic access below)
Resumo:
This project aims the verification of doses in canines and felines to chest and coxal exams due to the transition from screen-film to computed radiography system. It also seeks a possible optimization of the new techniques employed in this new system. The study was carried out in Diagnostic Imaging service in Hospital Veterinário da Faculdade de Medicina Veterinária e Zootecnia da Universidade de São Paulo using a conventional x-ray equipment. Initially, data about the physical characteristics of animals and the technique currently used in computed radiography was collected for each of 80 chest and 16 coxal X-ray examinations. The animals were divided into different groups according to the body weight. For each group, were calculated the averages of each item: thickness of the region to be imaged, voltage, current, exposure time, current-time product, size of film used, presence or absence of bucky and focus (small or large). The techniques have been reproduced in phantoms (representative of the thickness of the animal) in order to collect the air kerma entrance. Based on the average of intermediate size M group (weights less than 5 kg for cats and from 10.1 kg and 20 kg for dogs) analysis of image quality using three devices test patterns were made consisting of the evaluation of spatial resolution, low-contrast resolution and contrast-detail. In general, the results showed the dose animals decreased with the use of computed radiography and was possible to preliminary optimization of some techniques used currently in CR
Resumo:
The analysis of natural processes, such as landslides, has a great importance for the prevention of accidents in pipelines, since it might compromise its security, with serious social and environmental implications. Considering the large territorial dimensions that pipelines can reach, remote sensing tools have great applicability for data acquisition, allowing the analysis of large areas in regular time periods. This study aims to analyze the relations between the occurrence of landslides and its natural conditionings, on a stretch of the ORBEL pipeline, in the municipalities of Duque de Caxias, Nova Iguaçu and Belford Roxo – Rio de Janeiro. GeoEye sensor system images were used with spatial resolution of 0.5 m, from November/2009, January/2010 and March/2010, that are months of summer rains. The work involved the characterization of the study area and existing landslides, through bibliographic data collection; the application of visual analysis techniques for the extraction of landslide scars and fractures; preparation of maps for the landslide constraints and preparation of the susceptibility map. In the images from November only three landslide scars were extracted, while in January there were 166 and 111 in March. Difficulties were found with the shading in the images. From the relations among landslide scars, lithological units, relief systems, slope, downhill profile and the generated map of landslide susceptibility, presented in 1:70,000 scale, it was possible to conclude that slope is the main determinant of the process, allied secondarily to downhill profile, relief systems and lithology
Resumo:
Nuclear medicine is a medical specialty related to imagery that deals with imaging techniques, diagnosis and therapy, allowing observing the physiological state of tissues noninvasively by marking the molecules participating of these physiological processes with radioactive isotopes, thus creating the called radionuclides. The image of a radionuclide is one of the most important applications of radioactivity in nuclear medicine. The equipment’s of nuclear medicine imaging use the principle of radiation detection, turning it into an electrical signal which, through specific algorithms, allows forming tomographic images that provide information about the functional status of organs. New detection systems have been developed for tomographic acquisitions using solid state detectors. These devices use crystals of cadmium zinc telluride (CdZnTe). Some of the advantages of this detector are a significant improvement of signal to noise ratio, the increased spectral and spatial resolution, which in sum, result in greater clarity of the images obtained, opening new perspectives for imaging protocols previously unattainable. In contrast, all other gamma-cameras equipped with vacuum tubes have remained relatively unchanged for nearly fifty years. In these gamma-cameras, the images are obtained using two steps significantly less efficient: the gamma rays are converted to light through a first device, and then the light is converted into an electrical signal through a second device. One of functions the Medical Physicist is related to the quality control of equipment. This control ensures that the information and images provided are true and thus credible to be used in medical reports. To perform this type of analysis the physicist must understand the performance characteristics and operation of all equipment of the department concerned; besides, in the absence of specific legislation, proposing...(Complete abstract click electronic access below)
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Pós-graduação em Agronomia - FEIS
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Aims: This study compared fractal dimension (FD) values on mandibular trabecular bone in digital and digitized images at different spatial and contrast resolutions. Materials and Methods: 12 radiographs of dried human mandibles were obtained using custom-fabricated hybrid image receptors composed of a periapical radiographic film and a photostimulable phosphor plate (PSP). The film/ PSP sets were disassembled, and the PSPs produced images with 600 dots per inch (dpi) and 16 bits. These images were exported as tagged image file format (TIFF), 16 and 8 bits, and 600, 300 and 150 dpi. The films were processed and digitized 3 times on a flatbed scanner, producing TIFF images with 600, 300 and 150 dpi, and 8 bits. On each image, a circular region of interest was selected on the trabecular alveolar bone, away from root apices and FD was calculated by tile counting method. Two-way ANOVA and Tukey’s test were conducted to compare the mean values of FD, according to image type and spatial resolution (α = 5%). Results: Spatial resolution was directly and inversely proportional to FD mean values and standard deviation, respectively. Spatial resolution of 150 dpi yielded significant lower mean values of FD than the resolutions of 600 and 300 dpi ( P < 0.05). A nonsignificant variability was observed for the image types ( P > 0.05). The interaction between type of image and level of spatial resolution was not signi fi cant (P > 0.05). Conclusion: Under the tested, conditions, FD values of the mandibular trabecular bone assessed either by digital or digitized images did not change. Furthermore, these values were in fluenced by lower spatial resolution but not by contrast resolution.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Blooms of phytoplankton can be a risk to human health and aquatic biota, so the adoption of monitoring methods of phytoplankton and mechanisms for preventing its occurrence are needed. Thus, traditional monitoring methods could be more effective if complemented by approaches using the optical properties of phytoplankton pigments by means of Remote Sensing. In order to evaluate the potential of multi-scale remote sensing for detection of the phytoplankton activity, a study area was selected in Nova Avanhandava reservoir, located in the Tiete River, SP. For this analysis, hyperspectral field data and multispectral images of low and medium spatial resolution (Modis and RapidEye) were acquired and were related to indicator limnological variables of phytoplankton behavior; chlorophyll a and phycocyanin. The results show that a specific spectral band of RapidEye system (690-730 nm) allowed detect chlorophyll a and to evaluate the phytoplankton biomass, however hyperspectral data are needed to detect the phycocyanin pigment, indicative of cyanobacteria.