989 resultados para SCREENING ACCURACY
Resumo:
Click here to download PDF
Resumo:
Extracts of 13 Brazilian medicinal plants were screened for their antimicrobial activity against bacteria and yeasts. Of these, 10 plant extracts showed varied levels of antibacterial activity. Piper regnellii presented a good activity against Staphylococus aureus and Bacillus subtilis, a moderate activity on Pseudomonas aeruginosa, and a weak activity against Escherichia coli. Punica granatum showed good activity on S. aureus and was inactive against the other standard strains. Eugenia uniflora presented moderate activity on both S. aureus and E. coli. Psidium guajava,Tanacetum vulgare, Arctium lappa, Mikania glomerata, Sambucus canadensis, Plantago major and Erythrina speciosa presented some degree of antibacterial activity. Spilanthes acmella, Lippia alba, and Achillea millefolium were considered inactive. Five of the plant extracts presented compounds with Rf values similar to the antibacterial compounds visible on bioautogram. Of these, three plants belong to the Asteraceae family. This may mean that the same compounds are responsible for the antibacterial activity in these plants. Anticandidal activity was detected in nine plant extracts (P. guajava, E. uniflora, P. granatum, A. lappa, T. vulgare, M. glomerata, L. alba, P. regnellii, and P. major). The results might explain the ethnobotanical use of the studied species for the treatment of various infectious diseases.
Resumo:
Three hundred and thirteen extracts from 136 Brazilian plant species belonging to 36 families were tested for their suppressive activity on phytohemaglutinin (PHA) stimulated proliferation of human peripheral blood mononuclear cells (PBMC). The proliferation was evaluated by the amount of [³H]-thymidine incorporated by the cells. Twenty extracts inhibited or strongly reduced the proliferation in a dose-dependent manner at doses between 10 and 100 µg/ml. Three of these extracts appeared to be non-toxic to lymphocytes, according to the trypan blue permeability assay and visual inspection using optical microscopy. Bioassay-guided fractionation of Alomia myriadenia extract showed that myriadenolide, a labdane diterpene known to occur in this species, could account for the observed activity of the crude extract. Using a similar protocol, an active fraction of the extract from Gaylussacia brasiliensis was obtained. Analysis of the ¹H and13C NMR spectra of this fraction indicates the presence of an acetylated triterpene whose characterization is underway. The extract of Himatanthus obovatus is currently under investigation.
Resumo:
Background: Urinary human chorionic gonadotropin (hCG) concentration is routinely measured in all anti-doping laboratories to exclude the misuse of recombinant or urinary hCG preparations. In this study, extended validation of two commercial immunoassays for hCG measurements in urine was performed. Both tests were initially designed for hCG determination in human serum/plasma. Methods: Access (R) and Elecsys (R) 1010 are two automated immunoanalysers for central laboratories. The limits of detection and quantification, as well as intra-laboratory and inter-technique correlation, precision, and accuracy, were determined. Stability studies of hCG in urine following freezing and thawing cycles (n = 3) as well as storage conditions at room temperature, 4 degrees C and 20 degrees C, were performed. Results: Statistical evaluation of hCG concentrations in male urine samples (n = 2429) measured with the Elecsys (R) 1010 system enabled us to draw a skewed frequency histogram and establish a far outside value equal to 2.3 IU/L. This decision limit corresponds to the concentration at which a sportsman will be considered positive for hCG. Intra-assay precision for the Access (R) analyser was less than 4.0 A, whereas the inter-assay precision was closer to 4.5 % (concentrations of the official external controls contained between 5.5 and 195.0 IU/L). Intra and inter-assay precision for the Elecsys (R) 1010 analyser was slightly better. A good inter-technique correlation was obtained when measuring various urine samples (male and female). No urinary hCG loss was observed after two freeze/thaw cycles. On the other hand, time and inappropriate storage conditions, such as temperatures above 10 degrees C for more than 5 days, can deteriorate urinary hCG. Conclusions: Both analysers showed acceptable performances and are suitable for screening urine for anti-doping analyses. Each laboratory should validate and establish its own reference values because hCG concentrations measured in urine can be different from one immunoassay to another. The time delay between urine collection and analysis should be reduced as much as possible, and urine samples should be transported in optimal conditions to avoid a loss of hCG immunoreactivity.
Resumo:
ABSTRACT: Invasive candidiasis is a frequent life-threatening complication in critically ill patients. Early diagnosis followed by prompt treatment aimed at improving outcome by minimizing unnecessary antifungal use remains a major challenge in the ICU setting. Timely patient selection thus plays a key role for clinically efficient and cost-effective management. Approaches combining clinical risk factors and Candida colonization data have improved our ability to identify such patients early. While the negative predictive value of scores and predicting rules is up to 95 to 99%, the positive predictive value is much lower, ranging between 10 and 60%. Accordingly, if a positive score or rule is used to guide the start of antifungal therapy, many patients may be treated unnecessarily. Candida biomarkers display higher positive predictive values; however, they lack sensitivity and are thus not able to identify all cases of invasive candidiasis. The (1→3)-β-D-glucan (BG) assay, a panfungal antigen test, is recommended as a complementary tool for the diagnosis of invasive mycoses in high-risk hemato-oncological patients. Its role in the more heterogeneous ICU population remains to be defined. More efficient clinical selection strategies combined with performant laboratory tools are needed in order to treat the right patients at the right time by keeping costs of screening and therapy as low as possible. The new approach proposed by Posteraro and colleagues in the previous issue of Critical Care meets these requirements. A single positive BG value in medical patients admitted to the ICU with sepsis and expected to stay for more than 5 days preceded the documentation of candidemia by 1 to 3 days with an unprecedented diagnostic accuracy. Applying this one-point fungal screening on a selected subset of ICU patients with an estimated 15 to 20% risk of developing candidemia is an appealing and potentially cost-effective approach. If confirmed by multicenter investigations, and extended to surgical patients at high risk of invasive candidiasis after abdominal surgery, this Bayesian-based risk stratification approach aimed at maximizing clinical efficiency by minimizing health care resource utilization may substantially simplify the management of critically ill patients at risk of invasive candidiasis.
Resumo:
Dr James Reilly, Minister for Health requested the Health Service Executive to review the policy regarding the retention and disposal of Newborn Screening Cards (NSCs). The NSCs are an integral component of the National Newborn Bloodspot Screening Programme (NNBSP). The Minister had received representations concerning the archived NSCs stored by the National Newborn Bloodspot Screening Laboratory (NNBSL) at the Childrenâ?Ts University Hospital, Temple Street (CUH, T/S).  Click here to download PDF 146kb
Resumo:
We describe a streamlined reverse transcription-polymerase chain reaction methodology for constructing full-length cDNA libraries of trypanosomatids on the basis of conserved sequences located at the 5' and 3'ends of trans-spliced mRNAs. The amplified cDNA corresponded to full-length messengers and was amenable to in vitro expression. Fractionated libraries could be rapidly constructed in a plasmid vector by the TA cloning method (Invitrogen). We believe this is useful when there are concerns over the use of restriction enzymes and phage technology as well as in cases where expression of proteins in their native conformation is desired.
Resumo:
BACKGROUND: Missense mutations in three different genes encoding amyloid-β precursor protein, presenilin 1 and presenilin 2 are recognized to cause familial early-onset Alzheimer disease. Also duplications of the amyloid precursor protein gene have been shown to cause the disease. At the Dept. of Geriatric Medicine, Karolinska University Hospital, Sweden, patients are referred for mutation screening for the identification of nucleotide variations and for determining copy-number of the APP locus. METHODS: We combined the method of microsatellite marker genotyping with a quantitative real-time PCR analysis to detect duplications in patients with Alzheimer disease. RESULTS: In 22 DNA samples from individuals diagnosed with clinical Alzheimer disease, we identified one patient carrying a duplication on chromosome 21 which included the APP locus. Further mapping of the chromosomal region by array-comparative genome hybridization showed that the duplication spanned a maximal region of 1.09 Mb. CONCLUSIONS: This is the first report of an APP duplication in a Swedish Alzheimer patient and describes the use of quantitative real-time PCR as a tool for determining copy-number of the APP locus.
Resumo:
[Table des matières] 1. Problemstellung. 1.1. Programme in anderen Ländern. 1.2. Situation in der Schweiz. 2. Methodisches Vorgehen. 2.1. Dokumentationsanalyse. 2.2. Experteninterviews. 3. Resultate : Beschreibung der wesentlichen Aktivitäten zur Programmentwicklung. 3.1. Wesentliche Aktivitäten in der Schweiz vor der Einführung des KVG. 3.2. Grundeinstellung zum organisierten Mammographie-Screening. 3.3. Gesetzliche Grundlagen. 3.4. Strukturen im schweizerischen Gesundheitswesen. 3.5. Finanzierung. 3.6. Rollen und Kompetenzen. 3.7. Wirksamkeit. 3.8. Internationale Expertise. 4. Lösungsansätze.
Resumo:
This leaflet is used to support the Northern Ireland breast screening programme and explains the importance of screening in detecting breast cancer.
Resumo:
This leaflet explains the benefits of blood spot screening for the newborn
Resumo:
This leaflet is used to support the Northern Ireland breast screening programme and explains the additional tests that may be offered at a breast assessment clinic following a mammogram that has shown a possible abnormality
Resumo:
This leaflet is used to support the Northern Ireland breast screening programme and is issued to the one in 20 women who are called back after their initial breast x-ray for further tests at a breast assessment clinic
Resumo:
This leaflet is used to support the Northern Ireland breast screening programme and explains the procedure for women with breast implants