914 resultados para Ressonância magnética funcional


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The purpose of this paper was to study patients with congenital and acquired hemiparesis, their clinical aspects, the presence or not of epileptic seizures, and electroencephalographic (EEG) and Magnetic Resonance Imaging (MRI) findings. We analyzed the interrelation between etiology, the presence and seriousness of epileptic seizures (ES) and the possible causes of refractoriness. This is a prospective study using the clinical diagnosis of a child neurologist, who attested to the presence of unilateral motor lesions. We compared the electroencephalographic findings in patients with or without epileptic seizures, and investigated if among the former, these seizures were controlled or not, their likely etiology and risks of refractoriness. EEG background activity on the lesion and contralateral side was analyzed, in addition to the presence of concomitant epileptiform activity. Encephalon MRIs of all the patients were studied to correlate etiology and the control or not of epileptic seizures. The disorganization of bilateral EEG activity correlated with the difficult-to-control epileptic seizures. Suitably organized background activity contralateral to the lesion is a good prognosis in relation to epileptic seizures. Focal epileptogenic activity does not necessarily predispose to epileptic manifestation. The MRI is more important in determining etiology than in prognosing epileptic seizures. This study used a multidisciplinary approach involving child neurologists, a physical therapist and a neuroradiologist. This meets the criteria of multidisciplinarity of the Postgraduate Program in Health Sciences

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Partindo de apresentação da proposta de análise de acidentes baseada no modelo sistêmico e não linear de acidentes, dito de ressonância funcional, desenvolvido por Erik Hollnagel, este texto discute críticas às concepções deterministas de acidente e aos modelos lineares de representação desses eventos. Aspectos do modelo de ressonância funcional são usados como eixo definidor de proposta de agenda de discussões a ser desenvolvida pelos interessados no tema da análise de acidentes, destacando-se: a) a defesa do abandono da idéia de causas de acidentes e sua substituição pela de explicação desses eventos; b) apresentação dos conceitos de variabilidade de desempenhos e adaptações locais e a proposta de sua utilização como bases para a identificação de perfis ou aspectos típicos de acidentes. Por fim, discute-se a necessidade de incorporação dos conceitos apresentados no debate sobre novos caminhos para as práticas de análises e de prevenção de acidentes em nosso país.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Resumen Introducción Una posible opción de tratamiento para el manejo del trastorno depresivo mayor (TDM) es la estimulación magnética transcraneal (EMT) que ha mostrado propiedades antidepresivas superiores al placebo con un buen perfil de seguridad. El objetivo del presente trabajo es determinar la reducción en la severidad del TDM y la proporción de eventos adversos (EA) en pacientes con TDM refractario y no refractario, posterior al uso de EMT administrada en monoterapia o tratamiento coadyuvante comparado con terapia farmacológica. Metodología Se planteó una pregunta PICOT de la cual se realizó una búsqueda sistemática de estudios clínicos en las bases de datos Medline, EMBASE y Cochrane. Dos investigadores en forma independiente realizaron la selección de artículos, evaluación de calidad con la herramienta de la colaboración Cochrane y extracción de datos. Se extrajeron datos de eficacia como tasa de respuesta, porcentaje de remisión, calidad de vida, diminución sintomática del trastorno depresivo mayor en la escala de Hamilton y capacidad funcional. Igualmente, proporción de pacientes con EA. Se realizó un meta-análisis de estas variables teniendo en cuenta la heterogeneidad. Resultados La presente revisión sistemática incluyó 26 estudios clínicos aleatorizados de baja calidad metodológica mostrando que la EMT presentó una eficacia superior cuando es usada como coadyuvante a las terapias con que venían siendo tratados los pacientes con TDM refractario y no refractario en los desenlaces de tasa de respuesta y porcentaje de remisión. En el caso de intervenciones farmacológicas específicas, la EMT presento eficacia similar, tanto en terapia coadyuvante como en monoterapia comparado con las intervenciones farmacológicas. En cuanto a seguridad, la EMT presenta un buen perfil de seguridad debido a que en todos los escenarios estudiados los EA fueron no serios y baja frecuencia Conclusiones La evidencia disponible sugiere que la EMT mostró ser efectivo y seguro para el manejo del TDM refractario y no refractario. Sin embargo, la evidencia es débil por lo tanto se necesita mayor investigación clínica que soporte su uso.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, we investigated the magnetic properties of a monocrystalline Fe thin film and of Fe(80 Å)/Cr(t)/Fe(80 Å) tri-layers, with the nonmagnetic metallic Cr spacer layer thickness varying between 9 Å < t < 40 Å. The samples were deposited by the DC Sputtering on Magnesium Oxide (MgO) substrates, with (100) crystal orientation. For this investigation, experimental magneto-optical Kerr effect (MOKE) magnetometry and ferromagnetic resonance (FMR) techniques were employeed. In this case, these techniques allowed us to study the static and dynamical magnetization properties of our tri-layers. The experimental results were interpreted based on the phenomenological model that takes into account the relevant energy terms to the magnetic free energy to describe the system behavior. In the case of the monocrystalline Fe film, we performed an analytical discussion on the magnetization curves and developed a numerical simulation based on the Stoner-Wohlfarth model, that enables the numerical adjustment of the experimental magnetization curves and obtainment of the anisotropy field values. On the other hand, for the tri-layers, we analyzed the existence of bilinear and biquadratic couplings between the magnetizations of adjacent ferromagnetic layers from measurements of magnetization curves. With the FMR fields and line width angular dependencies, information on the anisotropy in three layers was obtained and the effects of different magnetic relaxation mechanisms were evidenced. It was also possible to observe the dependence of the epitaxy of the multilayers with growth and sputtering parameters. Additionally it was developed the technique of AC magnetic susceptibility in order to obtain further information during the investigation of magnetic thin films

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The study and fabrication of nanostructured systems composed of magnetic materials has been an area of great scientific and technological interest. Soft magnetic materials, in particular, have had great importance in the development of magnetic devices. Among such materials we highlight the use of alloys of Ni and Fe, known as Permalloy. We present measurement results of structural characterization and magnetic films in Permalloy (Ni81Fe19), known to be a material with high magnetic permeability, low coercivity and small magneto- crystalline anisotropy, deposited on MgO (100) substrates. The Magnetron Sputtering technique was used to obtain the samples with thicknesses varying between 9 150 nm. The techniques of X- ray Diffraction at high and low angle were employed to confirm the crystallographic orientation and thickness of the films. In order to investigate the magnetic properties of the films the techniques of Vibrant Sample Magnetometry (VSM), Ferromagnetic Resonance (FMR) and Magnetoimpedance were used. The magnetization curves revealed the presence of anisotropy for the films of Py/MgO (100), where it was found that there are three distinct axis - an easy-axis for θH = 0°, a hard-axis for θH = 45° and an intermediate for θH = 90°. The results of the FMR and Magnetoimpedance techniques confirm that there are three distinct axes, that is, there is a type C2 symmetry. Then we propose, for these results, the interpretation of the magnetic anisotropy of Py/MgO ( 100 ) is of type simple C2, ie a cubic magnetic anisotropy type ( 110 )

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCCIÓN: El Edema Macular (EM) es la principal causa de perdida de agudeza visual en pacientes con Oclusión Venosa Retiniana (OVR); luego del tratamiento, algunos pacientes persisten con mala agudeza visual. OBJETIVO: Realizar una Revisión Sistemática de la Literatura (RSL), para identificar la evidencia existente sobre factores tomográficos que predicen el resultado visual en pacientes con EM secundario a OVR. FUENTE DE LA INFORMACIÓN: PUBMED, MEDLINE, EMBASE, LILACS, COCHRANE, literatura gris. SELECCIÓN DE LOS ESTUDIOS: Ensayos Clínicos Controlados (ECC) y estudios observacionales analíticos. EXTRACCIÓN Y SÍNTESIS DE LOS DATOS: Dos investigadores seleccionaron los artículos de forma independiente. Se realizó una síntesis cualitativa de la información siguiendo las recomendaciones de la declaración PRISMA 2009. MEDIDAS Y DESENLACE PRINCIPAL: Grosor Retiniano Central (GRC), integridad de Banda Elipsoide e Integridad de Membrana Limitante Externa (MLE), determinados por SD OCT. El desenlace principal es la Agudeza Visual Mejor Corregida (AVMC) a los 6, 12,18 y/o 24 meses. RESULTADOS: Se identificaron 872 abstract y se incluyeron 8 artículos en el análisis cualitativo. Seis estudios evaluaron el GRC sin encontrar asociación con resultado visual final. Solo 2 estudios evaluaron y encontraron asociación estadísticamente significativa de la integridad de la MLE con el desenlace visual, Kang, H 2012 (r2 0,51 p 0,000), Rodriguez, F 2014 (p< 0,001). La integridad de la BE fue asociada a pronostico visual en 4 de 5 estudios que evaluaron esta variable, con resultados estadísticamente significativos. La AVMC de base también se asocio con desenlace visual en 4 de 5 estudios que la evaluaron. El mejor modelo que predice el resultado funcional según el estudio de Kang, H 2012 fue: Integridad de MLE, integridad de BE y AVMC de base (R2 0,671 p 0,000), a los 12 meses de seguimiento. CONCLUSION: La evidencia actual sugiere que la integridad de la BE y la MLE son predictores del resultados funcional en pacientes con EM secundario a OVR después de 6 o mas meses de seguimiento. Es necesario la realización de estudios controlados para llegar a resultados mas concluyentes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Early Years Generalizing Project (EYGP) involves Australian years 1 to 4 (age 5 to 9) students and investigates how they grasp and express generalizations. This paper focuses on data collected from 6 Year 1 students in an exploratory study within a clinical interview setting that required students to identify function rules. Preliminary findings suggest that the use of gestures (both by students and interviewers), self-talk (by students), and concrete acting out, assisted students to reach generalizations and to begin to express these generalities. It also appears that as students became aware of the structure, their use of gestures and selftalk tended to decrease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coleção de editais de concursos públicos reunidos pela Coordenação de Relacionamento Pesquisa e Informação do Centro de Documentação da Câmara dos Deputados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analisa, à luz das teorias do papel funcional e da motivação, a pesquisa de avaliação de desempenho dos servidores da Coordenação de Segurança Legislativa, realizada no ano 2000 pelo Centro de Formação Treinamento e Aperfeiçoamento da Câmara dos Deputados (Cefor).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aborda a estrutura funcional das comissões permanentes da Câmara dos Deputados, com enfoque especial na presença dos ocupantes de Cargos de Natureza Especial-CNE. Explica o fundamento legal, a jurisprudência e o histórico que envolvem a ocupação dos cargos em comissão. Analisa, com base em dados obtidos em pesquisa junto a secretários de comissão, de que maneira essa situação funcional interfere nos trabalhos das ditas comissões.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivando contribuir para o debate da judicialização da política no País, aborda os caminhos da dupla representação pública da sociedade brasileira moldados pela Constituição de 1988. Analisa o comportamento dos representantes políticos com relação ao Ministério Público, especialmente no que tange ao exercício da representação funcional da população, diante de seus reflexos no sistema representativo como um todo, no que diz respeito ao atendimento das necessidades de uma sociedade plural.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Analisa o Plano de Classificação Funcional da Câmara dos Deputados (PFC-CD) com a finalidade de verificar sua usabilidade como artefato do modelo de Arquitetura da Informação, a ser implementado por essa instituição.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudio del comportamiento frente a campos magnéticos y cambios de temperatura de unas aleaciones de NiMnGa depositadas en forma de película delgada sobre voladizos esculpidos en Silicio