971 resultados para RADIATION DETECTORS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Understanding the effects of radiation and its possible influence on the nervous system are of great clinical interest. However, there have been few electrophysiological studies on brain activity after exposure to ionizing radiation (IR). A new methodological approach regarding the assessment of the possible effects of IR on brain activity is the use of linear and nonlinear mathematical methods in the analysis of complex time series, such as brain oscillations measured using the electrocorticogram (ECoG). The objective of this study was to use linear and nonlinear mathematical methods as biomarkers of gamma radiation regarding cortical electrical activity. Adult Wistar rats were divided into 3 groups: 1 control and 2 irradiated groups, evaluated at 24 h (IR24) and 90 days (IR90) after exposure to 18 Gy of gamma radiation from a cobalt-60 radiotherapy source. The ECoG was analyzed using power spectrum methods for the calculation of the power of delta, theta, alpha and beta rhythms and by means of the α-exponent of the detrended fluctuation analysis (DFA). Using both mathematical methods it was possible to identify changes in the ECoG, and to identify significant changes in the pattern of the recording at 24 h after irradiation. Some of these changes were persistent at 90 days after exposure to IR. In particular, the theta wave using the two methods showed higher sensitivity than other waves, suggesting that it is a possible biomarker of exposure to IR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low-level lasers are used at low power densities and doses according to clinical protocols supplied with laser devices or based on professional practice. Although use of these lasers is increasing in many countries, the molecular mechanisms involved in effects of low-level lasers, mainly on DNA, are controversial. In this study, we evaluated the effects of low-level red lasers on survival, filamentation, and morphology of Escherichia colicells that were exposed to ultraviolet C (UVC) radiation. Exponential and stationary wild-type and uvrA-deficientE. coli cells were exposed to a low-level red laser and in sequence to UVC radiation. Bacterial survival was evaluated to determine the laser protection factor (ratio between the number of viable cells after exposure to the red laser and UVC and the number of viable cells after exposure to UVC). Bacterial filaments were counted to obtain the percentage of filamentation. Area-perimeter ratios were calculated for evaluation of cellular morphology. Experiments were carried out in duplicate and the results are reported as the means of three independent assays. Pre-exposure to a red laser protected wild-type and uvrA-deficient E. coli cells against the lethal effect of UVC radiation, and increased the percentage of filamentation and the area-perimeter ratio, depending on UVC fluence and physiological conditions in the cells. Therapeutic, low-level red laser radiation can induce DNA lesions at a sub-lethal level. Consequences to cells and tissues should be considered when clinical protocols based on this laser are carried out.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The control and monitoring of radioactive elements in foodstuffs is fundamental for human health maintenance. This work presents procedures to measure radioactivity levels in powdered milk samples and also a brief discussion of radionuclide transference from the environment to mankind. The measurements were performed utilizing a high-resolution gamma-ray spectrometer using an HPGe detector. The results allowed the quantification of 40K, 137Cs and 208Tl radionuclides. For 40K the average activity was 482 ± 37 Bq/kg and for 137Cs and 208Tl the lower level of detection was, respectively, 3.7 ± 1.1 and 0.5 ± 0.2 (Bq/kg). The results obtained for the milk samples were compared to data found in the literature and to the limits established by the Brazilian National Commission of Nuclear Energy (CNEN) to assure its safety to human consuption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Brazil, although the coffee plantations are predominantly grown under full sunlight, the use of agroforestry systems can lead to socioeconomic advantages, thus providing a favorable environment to the crop by promoting its sustainability as well as environmental preservation. However, there is a lack of information on physiological quality of the coffee seeds produced under different levels of solar radiation. Within this context, the objective of this study was to evaluate the influence of different levels of solar radiation and maturation stages on the physiological quality of coffee (Coffea arabica L.) seeds, cv. Acaiá Cerrado MG-1474. Three levels of solar radiation (plants grown under full sunlight; under plastic screens of 35% shading; and under plastic screens of 50% shading) and three maturation stages (cherry, greenish-yellow and green) were assessed. Physiological quality of seeds was assessed by using germination test, first count of germination, abnormal seedlings, dead seeds, and seedlings with open cotyledonary leaves. Electrophoretic analysis of isoenzymes catalase, esterase, superoxide dismutase and peroxidase was also performed. With the evolution of development the coffee seeds presents increases on physiological quality, and at its beginning the seeds show improvements on quality with the reduction of solar radiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Young soybean plants (Glycine ~. L. cultivar Harosoy '63), grown under controlled conditions, were exposed to gamma radiation on a single occasion. One hour following exposure to 3,750 rads, the mature trifoliate leaf of the soybean plant was isolated in a closed system and permitted to photoassimilate approximately 1-5 pCi of 14C02 for 15 minutes. After an additional 45 minute-period, the plant was sacrificed and the magnitude of translocation and distribution pattern of 14C determined. In the non-irradiated plants 18~ of the total 14C recovered was outside the fed leaf blades and of this translocated 14c, 28~ was above the node of the fed leaf, 38~ in the stem below the node, 28~ in the roots and 7~ in the petiole. As well, in the irradiated plants, a smaller per cent (6~) of the total 14 C recovered was exported out of the source leaf blades. Of this translocated 14c , a smaller per cent (20~) was found in the apical region above the node of the source leaf and a higher per cent (45~) was recovered from the stem below the node and in the petiole (11~). The per cent of exported 14 C recovered from the root was unaffected by the radiation. Replacement of the shoot apex with 20 ppm IAA immediately following irradiation, only J partially increased the magnitude of translocation but did completely restore the pattern of distribution to that observed in the non-irradiated plants. From supplementary studies showing a radiationinduced reduction of photosynthetic rates in the source leaf and a reduction of the cumulative stem and leaf lengths in the apical sink region, the observed effects of radiation on the translocation process have been correlated to damage incurred by the source and sink regions. These data suggest that the reduction in the magnitude of translocation is the result of damage to both the source and sink regions rather than the phloem conducting tissue itself, whereas the change in the pattern of translocation is probably the result of a reduced rate of 14C-assimilate movement caused by a radiation-induced decrease of sink metabolism, especially the decrease in the metabolism of the apical sink.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since previous investigations have shown that low levels of ionizing radiation can induce a reduction in the rates of apparent photosynthesis and in the magnitude of photoassimilated l4C exported out of a leaf, the present studies were designed and conducted to determine the relationship, if any, between the radiation effects on these two physiological processes. The experiments were particularly designed to determine if the radiation-induced reduction in export is the result of the reduction in photosynthesis and hence availability of materials for translocation or the result of a reduction in the amount of energy available for the vein loading process. This study has shown that the radiation-induced reduction in l4C export out of a leaf is likely related to a loss of energy available for the vein loading process rather than a reduction in the supply of materials available for export due to reduced C02 uptake. The process of photophosphorylation was shown to be reduced by exposure to radiation to an extent similar to the reduction in the export of l4C which was also observed. Both of these processes returned to their pre-irradiation rates 120 minutes following radiatruon exposure. The rate of photosynthetic C02 uptake was also reduced by radiation exposur~ howeve~ this process did not return to the control level nor was the extent of reduction as large as observed for photophosphorylation and photoassimilate export. The observed relationship between the reductions of export and photoph~sphorylation pointed to the utilization of photosynthetically produced ATP in the vein loading process. The radiation-induced reduction in the export of l4C was observed at the highest light intensity used in this study which would also imply the involvement of the photophosphorylation process as an energy seurce for vein loading. The lack of radiation-induced reduction in export at low light intensities was interpreted as being due to the utilization of respiratory derived ATP, a process known to be insensitive to radiation at the levels used in this study, as the energy source for the vein loading process. Studies using plants not stressed by radiation showed that there was an increase in export of 14C with higher light intensities. In summary, the data has been interpreted as showing that at high light intensities the ATP, produced by photophosphorylation, is available for use in the vein loading process. The site of ATP utilization could not be determined from the data obtained in this study but possible sites have been indicated from the work done by other physiologists and are discussed in the thesis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method using L-cysteine for the determination of arsenous acid (As(III)), arsenic acid (As(V)), monomethylarsonic acid (MMAA), and dimethylarsinic acid (DMAA) by hydride generation was demonstrated. The instrument used was a d.c. plasma atomic emission spectrometer (OCP-AES). Complete recovery was reported for As(III), As(V), and DMAA while 86% recovery was reported for MMAA. Detection limits were determined, as arsenic for the species listed previously, to be 1.2, 0.8, 1.1, and 1.0 ngemL-l, respectively. Precision values, at 50 ngemL-1 arsenic concentration, were f.80/0, 2.50/0, 2.6% and 2.6% relative standard deviation, respectively. The L-cysteine reagent was compared directly with the conventional hydride generation technique which uses a potassium iodide-hydrochloric acid medium. Recoveries using L-cysteine when compared with the conventional method provided the following results: similar recoveries were obtained for As(III), slightly better recoveries were obtained for As(V) and MMAA, and significantly better recoveries for DMAA. In addition, tall and sharp peak shapes were observed for all four species when using L-cysteine. The arsenic speciation method involved separation by ion exchange .. high perfonnance liquid chromatography (HPLC) with on-line hydride generation using the L.. cysteine reagent and measurement byOCP-AES. Total analysis time per sample was 12 min while the time between the start of subsequent runs was approximately 20 min. A binary . gradient elution program, which incorporated the following two eluents: 0.01 and 0.5 mM tri.. sodium citrate both containing 5% methanol (v/v) and both at a pH of approximately 9, was used during the separation by HPLC. Recoveries of the four species which were measured as peak area, and were normalized against As(III), were 880/0, 290/0, and 40% for DMAA, MMAA and As(V), respectively. Resolution factors between adjacent analyte peaks of As(III) and DMAA was 1.1; DMAA and MMAA was 1.3; and MMAA and As(V) was 8.6. During the arsenic speciation study, signals from the d.c. plasma optical system were measured using a new photon-signal integrating device. The_new photon integrator developed and built in this laboratory was based on a previously published design which was further modified to reflect current available hardware. This photon integrator was interfaced to a personal computer through an AID convertor. The .photon integrator has adjustable threshold settings and an adjustable post-gain device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to determine whether there was any evidence of psychosexual morbidity among men who experienced radical radiation treatment for prostate cancer. With relatively little known or available retrospective data on the psychosexual implications of radical radiation treatment in men with prostate cancer, this study posited eight research questions which provided the basis for the research. Fifty men from Southern Ontario, between the ages of 52 to 78 years, were included in the study. They had been previously randomized to a clinical trial comparing radical radiation therapy by external beam radiation, or radical radiation using a combination of a temporary iridium implant plus external beam radiation, for localized or locally advanced prostate cancer. Assessment of sexual functioning, drive, attitudes, body image, and sexual satisfaction was drawn from a multidimensional approach, since psychosexuality was viewed as having an impact on biological, psychological, and sociological domains of functioning. Medical chart reviews, semi-structured interviews, demographical profiles of each participant, and the Derogatis Sexual Functioning Inventory (DSFI) were the methods used to collect data over a four-month period. Both quantitative and qualitative research methods were incorporated in the design and evaluation of the study. Frequencies, contingency analysis, Pearson's coefficient of correlation, t-tests, and ANOVA comprised the quantitative analysis. Data obtained from audio-taped interviews were analyzed qualitatively, and used for offering further insight and for facilitating the quantitative aspect of the analysis. Overall, there was sufficient evidence to suggest psychosexual morbidity among men who were treated with radiation therapy for prostate cancer. As well,there were a number of significant findings available to answer all of the posited research questions. The most significant findings were noted in post-treatment erectile ability and sexual activity. A post-treatment change in erectile ability was reported by eighty percent of men. Sixty percent of men noted a decrease in their ability to achieve an erection by reporting some morning stiffness only, penile rigidity insufficient for penetration, decreased control of erection, and loss of spontaneous erection. Other contributing factors associated with change in erectile status were: pain or altering sensation of orgasm, blood in ejaculate, pain and decreased amount of ejaculate, and penile numbness or pain. Eighty-two percent of men experienced a post-treatment change in sexual function, primarily due to the impact of decreasing erectile status. Only seven men reported that they experienced a decrease in desire mentally, whereas the vast majority did not experience any change in desire. Changes in foreplay, stress with optimal sexual positioning, and reduced spontaneity of sex, were other factors reported with the changes in sexual activity. The findings in this study broaden our understanding of what middle- to later-aged men feel and experience as they venture onward following treatment. This was the first study that evaluated available prospective data on pre-treatment erectile status and sexual activity. As well, this study was the first (with participant compliance rates of 100 percent) to have included an interview format to capture the views of such a large number of men. This study concluded with recommendations and implications for future research and practice as we move in the direction of understanding what is necessary for preserving psychosexual well being and enhancing quality of life in men treated with radiation therapy for prostate cancer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low levels of ionizing radiation induce two translocation responses in soybean: a reduction in photoassimilate export from leaves and a change in the distribution pattern of exported photoassimilate within the plant. In this investigation these responses have been further studied specifically to ascertain the site of radiation damage and to better understand the physiological responses observed. Experimentally the primary data was obtained from studies in which a mature trifoliate leaf of a young soybean plant (Glycine ~ L. cultivar Harosoy '63) is isolated in a closed transparent chamber and allowed to photoassimilate 14C02 for 15 minutes. This is followed by an additional 45 ~_il'1;ute period before the plant is sectl.o ne d an d 14 C-ra dl' oactl.v.l ty d eterml. ne d'l n a 11 parts. Such 14c data provides one with the magnitude and distribution pattern of translocation. Further analyses were conducted to determine the relative levels of the major photosynthetic products using the techniques of paper chromatography and autoradiography. Since differences between control and irradiated P 1 ants were not 0 b serve d l' n t h e par tl't"lo nlng 0 f 14 C between the 80% ethanol-soluble and -insoluble fractions 14 or in the relative amounts of C-products of photosynthesis, the reduction in export in irradiated plants is not likely due to reduced availability of translocatable materials. Data presented in this thesis shows that photoassimilate export was not affected by gamma radiation until a threshold dose between 2.0 and 3.0 krads was reached. It was also observed that radiation-induced damage to the export process was capable of recovery in a period of 1 to 2 hours provided high light intensity was supplied. In contrast, the distribution pattern was shown to be extremely radiosensitive with a low threshold dose between .25 and .49 krads. Although this process was also capable of recovery,lt" occurred much earlier and was followed by a secondary effect which lasted at least for the duration of the experiments. The data presented in this thesis is interpreted to suggest that the sites of radiation action for the two translocation responses are different. In regards to photoassimilate export, the site of action of ionizing radiation is the leaf, quite possibly the process of photophosphorylation which may provide energy directly for phloem loading and for membrane integrity of the phloem tissue* In regards to the pattern of distribution of exported photoassimilate, the site is likely the apical sink, possibly the result of changes of levels of endogenous hormones. By the selection of radiation exposure dose and time post-irradiation, it is possible to affect independently these two processes suggesting that each may be regulated independent of the other and involves a distinct site.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le glioblastome multiforme (GBM) représente la tumeur cérébrale primaire la plus agressive et la plus vascularisée chez l’adulte. La survie médiane après le diagnostic est de moins d’un an en l’absence de traitement. Malheureusement, 90% des patients traités avec de la radiothérapie après la résection chirurgicale d’un GBM développent une récidive tumorale. Récemment, le traitement des GBM avec radiothérapie et témozolomide, un agent reconnu pour ses propriétés antiangiogéniques, a permis de prolonger la survie médiane à 14,6 mois. Des efforts sont déployés pour identifier des substances naturelles capables d’inhiber, de retarder ou de renverser le processus de carcinogenèse. Epigallocatechin-3-gallate (EGCG), un polyphénol retrouvé dans le thé vert, est reconnu pour ses propriétés anticancéreuses et antiangiogéniques. L’EGCG pourrait sensibiliser les cellules tumorales cérébrales et les cellules endothéliales dérivées des tumeurs aux traitements conventionnels. Le chapitre II décrit la première partie de ce projet de doctorat. Nous avons tenté de déterminer si l’EGCG pourrait sensibiliser la réponse des GBM à l’irradiation (IR) et si des marqueurs moléculaires spécifiques sont impliqués. Nous avons documenté que les cellules U-87 étaient relativement radiorésistantes et que Survivin, une protéine inhibitrice de l’apoptose, pourrait être impliquée dans la radiorésistance des GBM. Aussi, nous avons démontré que le pré-traitement des cellules U-87 avec de l’EGCG pourrait annuler l’effet cytoprotecteur d’une surexpression de Survivin et potentialiser l’effet cytoréducteur de l’IR. Au chapitre III, nous avons caractérisé l’impact de l’IR sur la survie de cellules endothéliales microvasculaires cérébrales humaines (HBMEC) et nous avons déterminé si l’EGCG pouvait optimiser cet effet. Bien que les traitements individuels avec l’EGCG et l’IR diminuaient la survie des HBMEC, le traitement combiné diminuait de façon synergique la survie cellulaire. Nous avons documenté que le traitement combiné augmentait la mort cellulaire, plus spécifiquement la nécrose. Au chapitre IV, nous avons investigué l’impact de l’IR sur les fonctions angiogéniques des HBMEC résistantes à l’IR, notamment la prolifération cellulaire, la migration cellulaire en présence de facteurs de croissance dérivés des tumeurs cérébrales, et la capacité de tubulogenèse. La voie de signalisation des Rho a aussi été étudiée en relation avec les propriétés angiogéniques des HBMEC radiorésistantes. Nos données suggèrent que l’IR altère significativement les propriétés angiogéniques des HBMEC. La réponse aux facteurs importants pour la croissance tumorale et l’angiogenèse ainsi que la tubulogenèse sont atténuées dans ces cellules. En conclusion, ce projet de doctorat confirme les propriétés cytoréductrices de l’IR sur les gliomes malins et propose un nouveau mécanisme pour expliquer la radiorésistance des GBM. Ce projet documente pour la première fois l’effet cytotoxique de l’IR sur les HBMEC. Aussi, ce projet reconnaît l’existence de HBMEC radiorésistantes et caractérise leurs fonctions angiogéniques altérées. La combinaison de molécules naturelles anticancéreuses et antiangiogéniques telles que l’EGCG avec de la radiothérapie pourrait améliorer l’effet de l’IR sur les cellules tumorales et sur les cellules endothéliales associées, possiblement en augmentant la mort cellulaire. Cette thèse supporte l’intégration de nutriments avec propriétés anticancéreuses et antiangiogéniques dans le traitement des gliomes malins pour sensibiliser les cellules tumorales et endothéliales aux traitements conventionnels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les détecteurs ATLAS-MPX sont des détecteurs Medipix2-USB recouverts de convertisseurs de fluorure de lithium et de polyéthylène pour augmenter l’efficacité de détection des neutrons lents et des neutrons rapides respectivement. Un réseau de quinze détecteurs ATLAS-MPX a été mis en opération dans le détecteur ATLAS au LHC du CERN. Deux détecteurs ATLAS-MPX de référence ont été exposés à des sources de neutrons rapides 252 Cf et 241 AmBe ainsi qu’aux neutrons rapides produits par la réaction 7Li(p, xn) pour l’étude de la réponse du détecteur à ces neutrons. Les neutrons rapides sont principalement détectés à partir des protons de recul des collisions élastiques entre les neutrons et l’hydrogène dans le polyéthylène. Des réactions nucléaires entre les neutrons et le silicium produisent des particules-α. Une étude de l’efficacité de reconnaissance des traces des protons et des particules-α dans le détecteur Medipix2-USB a été faite en fonction de l’énergie cinétique incidente et de l’angle d’incidence. L’efficacité de détection des neutrons rapides a été évaluée à deux seuils d’énergie (8 keV et 230 keV) dans les détecteurs ATLAS-MPX. L’efficacité de détection des neutrons rapides dans la région du détecteur couverte avec le polyéthylène augmente en fonction de l’énergie des neutrons : (0.0346 ± 0.0004) %, (0.0862 ± 0.0018) % et (0.1044 ± 0.0026) % pour des neutrons rapides de 2.13 MeV, 4.08 MeV et 27 MeV respectivement. L’étude pour déterminer l’énergie des neutrons permet donc d’estimer le flux des neutrons quand le détecteur ATLAS-MPX est dans un champ de radiation inconnu comme c’est le cas dans le détecteur ATLAS au LHC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Les seize détecteurs MPX constituant le réseau ATLAS-MPX ont été placés à différentes positions dans le détecteur ATLAS et sa averne au CERN dans le but de mesurer en emps réel les champs de radiation produits ar des particules primaires (protons des faisceaux) et des particules secondaires (kaons, pions, g, protons) issues des collisions proton-proton. Des films de polyéthylène (PE) et de fluorure de lithium (6LiF) recouvrent les détecteurs afin d’augmenter leur sensibilité aux neutrons produits par les particules primaires et secondaires interagissant avec les matériaux présents dans l’environnement d’ATLAS. La reconnaissance des traces laissées par les particules dans un détecteur ATLAS-MPX se fait à partir des algorithmes du logiciel MAFalda (“Medipix Analysis Framework”) basé sur les librairies et le logiciel d’analyse de données ROOT. Une étude sur le taux d’identifications erronées et le chevauchement d’amas a été faite en reconstruisant les activités des sources 106Ru et 137Cs. L’efficacité de détection des neutrons rapides a été mesurée à l’aide des sources 252Cf et 241AmBe (neutrons d’énergie moyenne de 2.13 et 4.08 MeV respectivement). La moyenne des efficacités de détection mesurées pour les neutrons produits par les sources 252C f et 241AmBe a été calculée pour les convertisseurs 6LiF et PE et donnent (0.8580 ± 0.1490)% et (0.0254 ± 0.0031)% pour LiF et (0.0510 ± 0.0061)% et (0.0591 ± 0.0063)% pour PE à bas et à haut seuil d’énergie respectivement. Une simulation du calcul de l’efficacité de détection des neutrons dans le détecteur MPX a été réalisée avec le logiciel GEANT4. Des données MPX correspondant aux collisions proton-proton à 2.4 TeV et à 7 TeV dans le centre de masse ont été analysées. Les flux détectés d’électrons et de photons sont particulièrement élevés dans les détecteurs MPX01 et MPX14 car ils sont plus près du point de collision. Des flux de neutrons ont été estimés en utilisant les efficacités de détection mesurées. Une corrélation avec la luminosité du LHC a été établie et on prédit que pour les collisions à 14 TeV dans le centre de masse et avec une luminosité de 10^34 cm-1*s-1 il y aura environ 5.1x10^8 ± 1.5x10^7 et 1.6x10^9 ± 6.3x10^7 particules détectées par les détecteurs MPX01 et MPX14 respectivement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Un réseau de seize détecteurs ATLAS-MPX a été mis en opération dans le détecteur ATLAS au LHC du CERN. Les détecteurs ATLAS-MPX sont sensibles au champ mixte de radiation de photons et d’électrons dans la caverne d’ATLAS et sont recouverts de convertisseurs de fluorure de lithium et de polyéthylène pour augmenter l’efficacité de détection des neutrons thermiques et des neutrons rapides respectivement. Les collisions à haute énergie sont dominées par des interactions partoniques avec petit moment transverse pT , associés à des événements de “minimum bias”. Dans notre cas la collision proton-proton se produit avec une énergie de 7 TeV dans le centre de masse avec une luminosité de 10³⁴cm⁻²s⁻¹ telle que fixée dans les simulations. On utilise la simulation des événements de "minimum bias" générés par PYTHIA en utilisant le cadre Athena qui fait une simulation GEANT4 complète du détecteur ATLAS pour mesurer le nombre de photons, d’électrons, des muons qui peuvent atteindre les détecteurs ATLASMPX dont les positions de chaque détecteur sont incluses dans les algorithmes d’Athena. Nous mesurons les flux de neutrons thermiques et rapides, générés par GCALOR, dans les régions de fluorure de lithium et de polyéthylène respectivement. Les résultats des événements de “minimum bias” et les flux de neutrons thermiques et rapides obtenus des simulations sont comparés aux mesures réelles des détecteurs ATLAS-MPX.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thèse numérisée par la Division de la gestion de documents et des archives de l'Université de Montréal