997 resultados para Protection devices
Resumo:
PURPOSE: The objective of this study was to evaluate the long-term safety and pharmacokinetic profile of a dexamethasone-loaded poly-epsilon-caprolactone (PCL) intravitreous implant. METHODS: The PCL devices were prepared by compression and were inserted into the vitreous of pigmented rabbits. At different time points, vitreous samples were retrieved, and dexamethasone concentration was analyzed by high-performance liquid chromatography. The biodegradation of the implants was evaluated by scanning electron microscopy, and the dexamethasone remaining was evaluated at the end of follow-up. Clinical and histologic examinations were performed to evaluate the implant's tolerance. RESULTS: The PCL implant allows for a controlled and prolonged delivery of dexamethasone in rabbits eyes since it released the drug within the therapeutic range for at least 55 weeks. At 55 weeks approximately 79% of the drug was still present in the implant. Biodegradation study showed that PCL implants degradation is very slow. Clinical and histologic observations showed that the devices were very well tolerated in the rabbit eye. CONCLUSIONS: This study demonstrates the feasibility and tolerance of intravitreous PCL drug delivery systems, which can offer a wide range of applications for intraocular drug delivery because of their controlled and prolonged release over months or even years.
Resumo:
Introduction : Confronter les intérêts de la protection de la nature à d'autres, c'est vouloir faire passer les petites fleurs et les grenouilles avant l'Homme. Hérésie ! C'est en effet parfois l'existence même d'un régime légal de protection des biotopes qui fait sourire. L'étudier en profondeur n'en paraît que plus oiseux. Ce problème d'acceptation est sans doute propre au droit de l'environnement de manière générale : l'intérêt public défendu ici n'est pas rattachable directement à l'intérêt du plus grand nombre. On peut parfois même en être très loin. Si, malgré cela, certains domaines du droit de l'environnement sont actuellement très en vogue, la protection de la nature fait partie de ses aspects moins porteurs. Ce type de préoccupations est pour beaucoup futile, voire inutile ou même déplacé. Il apparaît ainsi important de commencer par se demander pourquoi protéger la nature, et que protéger dans cette nature (chapitre 1). Vient ensuite évidemment la question de la portée de la protection. Il convient pour cela tout d'abord de faire le point sur le droit en vigueur (chapitre 2) : l'histoire des règles topiques en matière de protection des biotopes a été particulièrement mouvementée et son analyse apporte un important éclairage à la compréhension des dispositions actuelles ; cette législation est en outre complétée par une multitude de dispositions connexes ou apparentées, de droit interne et de droit international. Ce contexte général posé, la portée de la protection s'examine plus précisément par l'analyse des articles 18 ss LPN (chapitre 3) : les biotopes protégés de manière générale par l'article 18 LPN lui-même - remarquable exemple d'un droit dynamique -, les biotopes inventoriés et la végétation des rives. Il est enfin nécessaire de se pencher sur le « comment protéger» par une étude des instruments de mise en oeuvre (chapitre 4) et des instruments auxiliaires à la protection (chapitre 5). Ce faisant, la pertinence du régime légal de protection des biotopes sera soulignée, tant sur le fond que sur la forme. En l'introduisant aux subtilités de ce régime et de son intégration dans l'ordre juridique en général, nous espérons ainsi faire passer le lecteur au-delà des idées reçues.
La santé psychosociale à l'école : facteurs de risque et facteurs de protection pour les élèves
Resumo:
BACKGROUND: There is a growing use of mobile devices to access the Internet. We examined whether participants who used a mobile device to access a brief online survey were quicker to respond to the survey but also, less likely to complete it than participants using a traditional web browser. FINDINGS: Using data from a recently completed online intervention trial, we found that participants using mobile devices were quicker to access the survey but less likely to complete it compared to participants using a traditional web browser. More concerning, mobile device users were also less likely to respond to a request to complete a six week follow-up survey compared to those using traditional web browsers. CONCLUSIONS: With roughly a third of participants using mobile devices to answer an online survey in this study, the impact of mobile device usage on survey completion rates is a concern. TRIAL REGISTRATION: ClinicalTrials.gov: NCT01521078.
Resumo:
The choice of a research path in attacking scientific and technological problems is a significant component of firms’ R&D strategy. One of the findings of the patent races literature is that, in a competitive market setting, firms’ noncooperative choices of research projects display an excessive degree of correlation, as compared to the socially optimal level. The paper revisits this question in a context in which firms have access to trade secrets, in addition to patents, to assert intellectual property rights (IPR) over their discoveries. We find that the availability of multiple IPR protection instruments can move the paths chosen by firms engaged in an R&D race toward the social optimum.
Resumo:
Neutralizing antibodies are necessary and sufficient for protection against infection with vesicular stomatitis virus (VSV). The in vitro neutralization capacities and in vivo protective capacities of a panel of immunoglobulin G monoclonal antibodies to the glycoprotein of VSV were evaluated. In vitro, neutralizing activity correlated with avidity and with neutralization rate constant, a measure of on-rate. However, in vivo, protection was independent of immunoglobulin subclass, avidity, neutralization rate constant, and in vitro neutralizing activity; above a minimal avidity threshold, protection depended simply on a minimum serum concentration. These two biologically defined thresholds of antibody specificity offer hope for the development of adoptive therapy with neutralizing antibodies.
Resumo:
It is commonly regarded that the overuse of traffic control devices desensitizes drivers and leads to disrespect, especially for low-volume secondary roads with limited enforcement. The maintenance of traffic signs is also a tort liability concern, exacerbated by unnecessary signs. The Federal Highway Administration’s (FHWA) Manual on Uniform Traffic Control Devices (MUTCD) and the Institute of Transportation Engineer’s (ITE) Traffic Control Devices Handbook provide guidance for the implementation of STOP signs based on expected compliance with right-of-way rules, provision of through traffic flow, context (proximity to other controlled intersections), speed, sight distance, and crash history. The approach(es) to stop is left to engineering judgment and is usually dependent on traffic volume or functional class/continuity of system. Although presently being considered by the National Committee on Traffic Control Devices, traffic volume itself is not given as a criterion for implementation in the MUTCD. STOP signs have been installed at many locations for various reasons which no longer (or perhaps never) met engineering needs. If in fact the presence of STOP signs does not increase safety, removal should be considered. To date, however, no guidance exists for the removal of STOP signs at two-way stop-controlled intersections. The scope of this research is ultra-low-volume (< 150 daily entering vehicles) unpaved intersections in rural agricultural areas of Iowa, where each of the 99 counties may have as many as 300 or more STOP sign pairs. Overall safety performance is examined as a function of a county excessive use factor, developed specifically for this study and based on various volume ranges and terrain as a proxy for sight distance. Four conclusions are supported: (1) there is no statistical difference in the safety performance of ultra-low-volume stop-controlled and uncontrolled intersections for all drivers or for younger and older drivers (although interestingly, older drivers are underrepresented at both types of intersections); (2) compliance with stop control (as indicated by crash performance) does not appear to be affected by the use or excessive use of STOP signs, even when adjusted for volume and a sight distance proxy; (3) crash performance does not appear to be improved by the liberal use of stop control; (4) safety performance of uncontrolled intersections appears to decline relative to stop-controlled intersections above about 150 daily entering vehicles. Subject to adequate sight distance, traffic professionals may wish to consider removal of control below this threshold. The report concludes with a section on methods and legal considerations for safe removal of stop control.
Resumo:
BACKGROUND: Closures of atrial septal defects or a patent foramen ovale (PFO) are increasingly performed percutaneously. The experience of late migration of a new bio-absorbable device is presented here, followed by conceptual discussion. METHODS: Six months post PFO closure with a BioSTAR® device a patient presented with chest pain. Echocardiography showed a hyperechogenic structure perforating the aortic wall. RESULTS: Surgical exploration showed a perforation of the ascending aorta by one metallic, non absorbable arm. This is the second case of late (>6 months) dislocation of the residual framework of the occluder. CONCLUSIONS: The overall incidence of perforation of cardiac structures due to secondary dislocation is low. However this complication exists and should kept in mind in symptomatic patients with new onset of chest pain, after percutaneous procedures. The concept of biodegradation, with residual, non absorbable metal braiding, should be reviewed, analyzing in particular long term results and incidence of secondary dislocation.