1000 resultados para Pressão de fluido
Resumo:
This study aimed to validate tools for evaluating the ability and knowledge about blood pressure (BP) among nursing students. It is a cross-sectional, descriptive, quantitative and methodological study accomplished at the Universidade Federal do Rio Grande do Norte (UFRN), Universidade do Estado do Rio Grande do Norte (UERN) and a private university of the state. The sample consisted of 27 judges of research selected from the inclusion criteria: nursing, teachers of the semiology and/or semiotics discipline, with at least 1 year of experience, being from UFRN, EEN, UERN and private university of the state and and agree to participate voluntarily with the signing of the consent form. The research was development in three stages: construction of two instruments based on the scientific literature, resulting in a structured checklist consists of 28 items and a knowledge questionnaire with 12 questions; submission of the instruments to the judges, in the period from June to September 2012, which should evaluate each item in appropriate , appropriate with changes and inappropriate , addition to making an overall assessment of each instrument based on 10 requirements; validation and verification to the level of agreement among the judges, through the application of Kappa and Content Validity Index (CVI). Was used the consensus level greater than 0.61 (good) to the Kappa index and greater than 0.75 for CVI. Was approved by the Ethics in Research / HUOL. After being coded and tabulated, the data were analyzed using descriptive statistics. Of the 27 judges who evaluated the instrument, 77.8% are female, with a mean age of 36.6 (± 9.0) years, 63.0% worked in UFRN, 74.1% had academic master and 63.0% worked exclusively on teaching. Average length of teaching experience was 7.9 (± 8.0) years and in the semiology and/or semiotics discipline of 5.5 (± 6.7) years. In the judgment of structured checklist and questionnaire of knowledge about blood pressure mensurement any item/question was considered inappropriate since all obtained level of agreement within the indices established (CVI> 0,75 E Kappa> 0.61). In relation to structured checklist, of those 28 items present, 9 showed perfect concordance index (CVI = 1.00, Kappa = 1.00) and another 19 were considered appropriate with changes, especially with regard to clarity and vocabulary. In the questionnaire of knowledge, among the 12 questions that comprised, 7 had perfect concordance index and the others were considered appropriate with changes as requirements as clarity, vocabulary, and feasible sequence of instructional topics. In terms of a overall evaluating of instruments, the structured checklist got CVI of 0.94 and Kappa of 0.89 and the knowledge questionnaire, CVI of 0.97 and a kappa of 0.94. Both instruments proved to be valid as to their content, configuring it as clear and objective tools of assessment of knowledge and ability on blood pressure, being of nursing students as well as others students and health professionals, since the use of valid measures seeking to reduce the risk of distorting the results
Resumo:
To characterize patients according to gender, age category, internment time, diagnostical hypothesis and location of the pressure ulcer; to identify the susceptibility conditions, intrinsical and extrinsical factors present on ICU patients and to verify on the existence of association between the susceptibility conditions and the intrinsecal and extrinsecal factors on the occurrence of PU. Methods: It is a descriptive study, of longitudinal design of the panel type, with quantitative approach, performed on two ICU s of a private hospital located in Natal/RN, with 40 patients interned at these units. The data collection was performed on all three shifts through a structured observation and physical exam of the patients' skin form seeking to identify the presence of PU. Results: The greatest occurence of PU was on individuals of the male gender (70%) when compared to the female gender (30%), that difference being statistically significant (p=0,0267), with the male gender presenting 4,3 times greater chance of developing PU than the female; the predominant age category was from 60 years of age on (85%), 60,0% presented 1 to 2 PU s after 7 (seven) days of permanence in the ICU s, the predominant diagnostical hypothesis on the patients with PU were the respiratory diseases (42,3%) and the most frequent locations of PU were the sacral region (40,0%) and heels (36,0%). 25 PU s of stage I were diagnosed on 50,0% of the followed patients, with general incidence of 50,0% on both ICUs. from the 88 variables researched, 75 were identified on the patients from the study, being the predominant conditions (anemia, hypotension, leukocytosis, other diseases hypertension blood pressure, cardiac insuffience, pneumonia - and ansiolythic), the intrinsecal factors (diminished muscular strenght and/or mass, discrete edema, totally compromised mobile coordination and total inability for movement on the bed) and the extrinsecal factors (inadequate mattress type, permanence on a single position for >2 hours, shearing/friction force, bed clothes with folds that leave marks on the body, pressure force) predominated on patients with PU. The male gender variables (p=0,0267,OR=4,3), sedation (p=0,0006,OR=4,1), psychomotive agitation (p=0,0375,OR=5,8) and leukocytosis (p=0,0285,OR=5,0) presented a significant statistical diference when analyzed independently. We verified an association of 17,3%, statistically significant (p=0,0384), between the susceptibility conditions (anemia, leukocytosis and hypotension), the intrinsecal factors (age equal or above 60 years, diminished/absent pain sensibility and smooth, fine or delicate skin) and the extrinsecal factors (inadequate mattress, pressure forces, shearing/friction force, permanence on a single position for more than 2 hours, elevation between 30 to 45 degrees and inadequate bed clothes' conditions), with a chance ratio of 4,6 times the risk of occurrence of PU on the patients that presented the referred association. Conclusion: The incidence of PU detected on the ICU-interned patients was high and we made evident the existence of association between the susceptibility conditions, the intrinsecal and extrinsecal factors on the occurrence of PU s on the ICUinterned patients, and thus we accept the alternative hypothesis proposed on the study
Resumo:
The present work presents an algorithm proposal, which aims for controlling and improving idle time to be applied in oil production wells equipped with beam pump. The algorithm was totally designed based on existing papers and data acquired from two Potiguar Basin pilot wells. Oil engineering concepts such as submergence, pump off, Basic Sediments and Water (BSW), Inflow Performance Relationship (IPR), reservo ir pressure, inflow pressure, among others, were included into the algorithm through a mathematical treatment developed from a typical well and then extended to the general cases. The optimization will increase the well production potential maximum utilization having the smallest number of pumping unit cycles directly reflecting on operational cost and electricity consumption reduction
Resumo:
Pipeline leak detection is a matter of great interest for companies who transport petroleum and its derivatives, in face of rising exigencies of environmental policies in industrialized and industrializing countries. However, existing technologies are not yet fully consolidated and many studies have been accomplished in order to achieve better levels of sensitivity and reliability for pipeline leak detection in a wide range of flowing conditions. In this sense, this study presents the results obtained from frequency spectrum analysis of pressure signals from pipelines in several flowing conditions like normal flowing, leakages, pump switching, etc. The results show that is possible to distinguish between the frequency spectra of those different flowing conditions, allowing recognition and announce of liquid pipeline leakages from pressure monitoring. Based upon these results, a pipeline leak detection algorithm employing frequency analysis of pressure signals is proposed, along with a methodology for its tuning and calibration. The proposed algorithm and its tuning methodology are evaluated with data obtained from real leakages accomplished in pipelines transferring crude oil and water, in order to evaluate its sensitivity, reliability and applicability to different flowing conditions
Resumo:
As unidades de beneficiamento de macadâmia adotam silos secadores distintos, para cada etapa de secagem, a fim de garantir a manutenção da qualidade do produto pela redução da umidade a níveis desejáveis. Diante da necessidade de quantificar a resistência apresentada pelas nozes, submetidas a diferentes fluxos de ar durante a secagem, bem como avaliar a possibilidade de utilização de modelos empíricos, que estimem o gradiente de pressão a partir da vazão de ar, conduziram-se vários testes em laboratório para obtenção de dados experimentais e ajuste de modelos. Frutos de macadâmia (M. integrifolia), com umidade de 0,11 b.s., após limpeza e classificação, foram colocados no interior de um protótipo constituído por uma coluna de chapa galvanizada (com tomadas para medição da pressão estática), plenum e ventilador, sendo submetidos a diferentes fluxos de ar. Os testes consistiram de três medidas por profundidade, para cada um dos três lotes de nozes, perfazendo um total de nove medidas de pressão estática por profundidade na coluna. Os resultados obtidos permitiram concluir que os fluxos de ar testados apresentaram efeito significativo sobre a queda de pressão estática na coluna de macadâmia, a qual aumentou linearmente com a profundidade. Os dados experimentais ajustaram-se muito bem aos modelos de Shedd e Hunter, sugerindo sua boa aplicabilidade para a macadâmia.
Resumo:
A compactação do solo tem sido assunto de intensivas pesquisas nos últimos anos; no entanto, os mecanismos que implicam o processo de compactação dos solos agrícolas, ainda permanecem pouco conhecidos. A contribuição do tamanho de agregados do solo, bem como o efeito do teor de água e da pressão normal aplicada na compactação e pressão de pré-compactação do solo, foi investigada em um Nitossolo Vermelho eutrófico. Amostras de solo deformado, constituídas por agregados menores que 2,5 mm e de 9,3 a 19,4 mm, foram submetidas a ensaio de compressão uniaxial drenado. O índice de vazios e a pressão de pré-compactação foram avaliados. Os resultados obtidos mostram que o tamanho de agregados teve efeito no processo de compactação do solo. A mudança da compactação do solo pode ser prevista em função do estado inicial do solo, da pressão aplicada e do teor de água.
Resumo:
Postsurgical complication of hypertension may occur in cardiac patients. To decrease the chances of complication it is necessary to reduce elevated blood pressure as soon as possible. Continuous infusion of vasodilator drugs, such as sodium nitroprusside (Nipride), would quickly lower the blood pressure in most patients. However, each patient has a different sensitivity to infusion of Nipride. The parameters and the time delays of the system are initially unknown. Moreover, the parameters of the transfer function associated with a particular patient are time varying. the objective of the study is to develop a procedure for blood pressure control i the presence of uncertainty of parameters and considerable time delays. So, a methodology was developed multi-model, and for each such model a Preditive Controller can be a priori designed. An adaptive mechanism is then needed for deciding which controller should be dominant for a given plant
Resumo:
Visando estabelecer a contribuição dos parâmetros físicos na qualidade final da silagem de grãos úmidos de milho, foi conduzido experimento, no interior de câmara climatizada, simulando cinco condições de temperatura ambiente (5ºC 24h-1 por dia; 25ºC 24h-1 por dia; 40ºC 24h-1 por dia; 20ºC 16h-1 por dia + 5ºC 8h-1 por dia; 30ºC 16h-1 por dia + 20ºC 8h-1 por dia) e duas condições de pressão no interior dos tambores de armazenagem (com e sem pressão interna). Para se determinar os efeitos sobre o grau de disponibilidade do amido na silagem pronta, procedeu-se a análises para avaliar a qualidade final da silagem (teor de umidade, pH, ácidos orgânicos, amido total e granulometria). O delineamento estatístico utilizado foi o inteiramente ao acaso, num fatorial 5 x 2, com três repetições. Os resultados obtidos indicaram influência significativa tanto da temperatura quanto da pressão, sendo os efeitos mais benéficos verificados nos tratamentos '30ºC 16h-1 por dia + 20ºC 8h-1 por dia', '25ºC 24h-1 por dia' e 'ausência de pressão'.
Resumo:
Hypertension is a dangerous disease that can cause serious harm to a patient health. In some situations the necessity to control this pressure is even greater, as in surgical procedures and post-surgical patients. To decrease the chances of a complication, it is necessary to reduce blood pressure as soon as possible. Continuous infusion of vasodilators drugs, such as sodium nitroprusside (SNP), rapidly decreased blood pressure in most patients, avoiding major problems. Maintaining the desired blood pressure requires constant monitoring of arterial blood pressure and frequently adjusting the drug infusion rate. Manual control of arterial blood pressure by clinical personnel is very demanding, time consuming and, as a result, sometimes of poor quality. Thus, the aim of this work is the design and implementation of a database of tuned controllers based on patients models, in order to find a suitable PID to be embedded in a Programmable Integrated Circuit (PIC), which has a smaller cost, smaller size and lower power consumption. For best results in controlling the blood pressure and choosing the adequate controller, tuning algorithms, system identification techniques and Smith predictor are used. This work also introduces a monitoring system to assist in detecting anomalies and optimize the process of patient care.
Resumo:
The sanitation companies from Brazil has a great challenge for the XXI century: seek to mitigate the rate of physical waste (water, chemicals and electricity) and financial waste caused by inefficient operating systems drinking water supply, considering that currently we already face, in some cases, the scarcity of water resources. The supply systems are increasingly complex as they seek to minimize waste and at the same time better serve the growing number of users. However, this technological change is to reduce the complexity of the challenges posed by the need to include users with higher quality and efficiency in services. A major challenge for companies of water supplies is to provide a good quality service contemplating reducing expenditure on electricity. In this situation we developed a research by a method that seeks to control the pressure of the distribution systems that do not have the tank in your setup and the water comes out of the well directly to the distribution system. The method of pressure control (intelligent control) uses fuzzy logic to eliminate the waste of electricity and the leaks from the production of pumps that inject directly into the distribution system, which causes waste of energy when the consumption of households is reduced causing the saturation of the distribution system. This study was conducted at Green Club II condominium, located in the city of Parnamirim, state of Rio Grande do Norte, in order to study the pressure behavior of the output of the pump that injects water directly into the distribution system. The study was only possible because of the need we had to find a solution to some leaks in the existing distribution system and the extensions of the respective condominium residences, which sparked interest in developing a job in order to carry out the experiments contained in this research
Resumo:
The main goal of the present work is related to the dynamics of the steady state, incompressible, laminar flow with heat transfer, of an electrically conducting and Newtonian fluid inside a flat parallel-plate channel under the action of an external and uniform magnetic field. For solution of the governing equations, written in the parabolic boundary layer and stream-function formulation, it was employed the hybrid, numericalanalytical, approach known as Generalized Integral Transform Technique (GITT). The flow is sustained by a pressure gradient and the magnetic field is applied in the direction normal to the flow and is assumed that normal magnetic field is kept uniform, remaining larger than any other fields generated in other directions. In order to evaluate the influence of the applied magnetic field on both entrance regions, thermal and hydrodynamic, for this forced convection problem, as well as for validating purposes of the adopted solution methodology, two kinds of channel entry conditions for the velocity field were used: an uniform and an non-MHD parabolic profile. On the other hand, for the thermal problem only an uniform temperature profile at the channel inlet was employed as boundary condition. Along the channel wall, plates are maintained at constant temperature, either equal to or different from each other. Results for the velocity and temperature fields as well as for the main related potentials are produced and compared, for validation purposes, to results reported on literature as function of the main dimensionless governing parameters as Reynolds and Hartman numbers, for typical situations. Finally, in order to illustrate the consistency of the integral transform method, convergence analyses are also effectuated and presented
Resumo:
The use of waste heat of energy conversion equipment to produce a cooling effect, consists currently in a very interesting way of efficiency improvement of energy systems. The present research has as intention the theoretical and experimental study of a new intermittent refrigeration system ejector cycle characteristics, with use of waste heat. Initially, was doing a bibliographical survey about the vapor ejector refrigeration system technology. In the following stage was doing a simulation of the corresponding thermodynamic cycle, with preliminarily intention to evaluate the performance of the system for different refrigerants fluids. On the basis of the results of the simulation were selected the refrigerant fluid and developed an experimental group of benches of the refrigeration system considered, where pressure and temperature sensory had been inserted in strategical points of the refrigeration archetype and connected to a computerized data acquisition system for measure the refrigerant fluid properties in the thermodynamic cycle. The test results obtained show good agreement with the literature
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico
Resumo:
Research for better performance materials in biomedical applications are constants. Thus recent studies aimed at the development of new techniques for modification of surfaces. The low pressure plasma has been highlighted for its versatility and for being environmentally friendly, achieving good results in the modification of physic chemical properties of materials. However, it is requires an expensive vacuum system and cannot able to generate superficial changes in specific regions. Furthermore, it is limits their use in polymeric materials and sensitive terms due to high process temperatures. Therefore, new techniques capable of generating cold plasma at atmospheric pressure (APPJ) were created. In order to perform surface treatments on biomaterials in specific regions was built a prototype capable of generating a cold plasma jet. The prototype plasma generator consists of a high voltage source, a support arm, sample port and a nozzle through which the ionized argon. The device was formed to a dielectric tube and two electrodes. This work was varied some parameters such as position between electrodes, voltage and electrical frequency to verify the behavior of glow discharges. The disc of titanium was polished and there was a surface modification. The power consumed, length, intensity and surface modifications of titanium were analyzed. The energy consumed during the discharges was observed by the Lissajous figure method. To check the length of the jets was realized with Image Pro Plus software. The modifications of the titanium surfaces were observed by optical microscopy (OM ) and atomic force microscopy (AFM ). The study showed that variations of the parameters such as voltage, frequency and geometric position between the electrodes influence the formation of the plasma jet. It was concluded that the plasma jet near room temperature and atmospheric pressure was able to cause modifications in titanium surface
Resumo:
Objetivou-se com este trabalho avaliar o efeito de pontas de pulverização, pressão e intensidade do vento na deriva gerada em aplicações simuladas de herbicidas aplicados em pré-emergência. Os modelos de pontas de pulverização e as respectivas pressões testadas foram: SF 11002 (207 e 310 kPa), JA-2 (345 e 655 kPa) e AVI 11002 (207 e 414 kPa). As aplicações foram realizadas em dois períodos, em dias com condições de velocidade de vento distintas, em uma área de 1.200 m², localizada na Fazenda Experimental da FCA/UNESP. Um pulverizador com barra de 12 m, 24 bicos e tanque de 600 L foi utilizado nas aplicações. A calda de aplicação foi composta por água e o corante alimentício FDC-1 foi usado como traçador. A deriva foi amostrada por coletores ativos fixados sobre a barra de pulverização. As velocidades mínimas, médias e máximas de vento registradas no primeiro e segundo períodos das aplicações foram de 7, 14 e 23 km h-1 e 1, 5 e 18 km h-1, respectivamente. Nas duas ocasiões de aplicação, as pontas de pulverização com indução de ar AVI 11002 e de jato cônico vazio JA-2 a 655 kPa resultaram nas menores e maiores quantidades de depósito de líquido detectadas, respectivamente. A maior intensidade do vento incrementou a deriva. A redução na pressão pode ser utilizada para controle de deriva, mas a seleção adequada de uma ponta mostrou ser mais eficiente para esse propósito.