950 resultados para Prótese total mucosuportada
Resumo:
L’artroplastia total de maluc cimentada, descrita per Charnley, és reconeguda per ser una de les intervencions més exitoses. Analitzem retrospectivament 595 artroplasties primàries tipus Charnley del nostre centre, durant 1986 i 2011. Com a punt final de supervivencia considerem el recanvi protèsic (afluixament asèptic, infecció o luxació), èxitus o pèrdua de seguiment. Els anàlisis de supervivència a llarg plaç, han sigut similars als obtinguts per altres autors. Aquest estudi identifica grups poblacionals que podrien beneficiar-se dels nous implants i tècniques que millorin aquesta exitosa pròtesi, i reafirma els bons resultats d’aquesta cirurgia, inclús a hospitals generals.
Resumo:
Total body irradiation (TBI) has an established role as preparative regimen for bone-marrow transplantation in the treatment of hematological malignancies. Many randomized trials demonstrated that the clinical outcomes obtained from the association of TBI and cyclophosphamide are equivalent, or, sometimes, better than those based on chemotherapeutic agents. Despite the therapeutic progress of the last years, and the consequent improvement in the overall survival, this preparative regimen remains always associated with a relatively high rate of acute and late toxicity. In this article, we review the actual indications of TBI in clinical practice, and analyze the technological progress in this domain. We focus on the hypothesis that a selective irradiation of the hematopoietic or lymphoid organs is actually possible with intensity-modulated radiotherapy. Technical limits and preliminary results in terms of acute and late toxicities of intensity-modulated TBI are analyzed. With these new technologies, treatment-related toxicity is not anymore a major limiting factor in the preparative regimens for bone-marrow transplantation, allowing for a larger spectrum of TBI indications, a possible extension to patients older than 50 years, or a dose escalation. Preliminary results warrant, however, further evaluation in clinical trials to better assess the impact of this new approach on disease control and the long-term toxicity.
Resumo:
The aim of this experimental study is to evaluate the feasibility and the outcome of total endovascular stent implantation in the aortic arch. Indications for this operation-technique would be acute or chronic dissection of the aortic arch (non-A-non-B dissection) or type B dissection with retrograde extension. Four pigs were canulated via the distal abdominal aorta and a retrograde placement of a Djumbodis arch stent (4-9 cm) was controlled by using intravascular ultrasound and intracardiac ultrasound by the inferior cava vein and under radioscopic control. Cerebral perfusion, by using a flow meter placed on one prepared carotid artery, were controlled before, immediate post-procedural (<1 min), and in the early follow-up after aortic arch stent implantation. During the implantation process, especially during balloon inflation and deflation, mean carotid perfusion decreases slightly. A reactive increase of carotid perfusion after stent placements indicates transitory cerebral hypo-perfusion. Non-covered aortic arch stent implantation is technically feasible and could be a potential treatment option in otherwise inoperable arch dissections. The time required for balloon inflation and deflation causes an important risk of cerebral ischemia. The latter can be reduced by transaxillary perfusion.
Resumo:
There is an increasing trend in the incidence of cancer worldwide, and it has been accepted that environmental factors account for an important proportion of the global burden. The present paper reports preliminary findings on the influence of the historical exposure to a group of persistent organic pollutants on total cancer risk, at year 9 in the follow-up of a cohort from Southern Spain. A cohort of 368 participants (median age 51 years) was recruited in 2003. Their historical exposure was estimated by analyzing residues of persistent organic pollutants in adipose tissue. Estimation of cancer incidence was based on data from a population-based cancer registry. Statistical analyses were performed using multivariable Cox-regression models. In males, PCB 153 concentrations were positively associated with total cancer risk, with an adjusted hazard ratio (95% confidence interval) of 1.20 (1.01-1.41) for an increment of 100 ng/g lipid. Our preliminary findings suggest a potential relationship between the historical exposure to persistent organic pollutants and the risk of cancer in men. However, these results should be interpreted with caution and require verification during the future follow-up of this cohort.
Resumo:
Total knee replacement (TKR) is an operation that has radically improved the quality of life of millions of people during the last decades. However, some technical details, concerning the surgical procedure, are still a matter of a strong debate. In this review of the literature, we have included the best evidence available of the last decade, related to TKR surgery like the use of tourniquet during operation, patellar resufacing, all-polyethilene tibial component, cemented or cementless fixation, mobile bearings, or posterior-stabilized versus cruciate-retaining prosthesis.
Resumo:
Aim: Assess the clinical utility of plain radiography in the first postoperative outpatient visit after total knee arthroplasty. Patients and Methods: 200 patients which underwent a total knee arthroplasty from January to May 2012 were analyzed retrospectively, they had two previous control radiographs at hospital discharge and two more at 4-6 weeks after surgery, which were compared, seeking for radiographics signs that would induce a therapeutic changes in the patient’s clinical course. Results: No radiographics signs were observed in the cases studied in the first postoperative visit one month after the surgery, consequently the patient’s treatment plan had no change. Discussion: Our results support those of other authors who have recognized the benefits of reducing the number of postoperative radiographs, improve the cost effectiveness of outpatients care and avoid an extra damage to the patient’s health. We believe that repeated use of serial radiographs in outpatient is simply a custom that has become law, to calm down the patient, and his surgeon, with no scientific evidence to support it use. Conclusions: Our results suggest that the plain AP and L radiographic projection at the first visit, one month later after a TKA, does not provide any clinic information, adds substantial cost to the heath-care system and unnecessary harms the patient.
Resumo:
Correct positioning of the tibial component in total knee arthroplasty (TKA) must take into account both an optimal bone coverage (defined by a maximal cortical bearing with posteromedial and anterolateral support) and satisfactory patellofemoral tracking. Consequently, a compromise position must be found by the surgeon during the operation to simultaneously meet these two requirements. Moreover, tibial tray positioning depends upon the tibial torsion, which has been shown to act mainly in the proximal quarter of the tibia. Therefore, the correct application of the tibial tray is also theoretically related to the level of bone resection. In this study, we first quantified the torsional profile given by an optimal bone coverage for a symmetrical tibial tray design and for an asymmetrical one. Then, for the two types of tibial trays, we measured the angle difference between optimal bone coverage and an alignment on the middle of the tibial tubercule. Results showed that the values of the torsional profile given by the symmetrical tray were more scattered than those from the asymmetrical one. However, determination of the mean differential angle between the position providing optimal bone coverage and the one providing the best patellofemoral tracking indicated that the symmetrical prosthetic tray offered the best compromise between these two requirements. Although the tibiofemoral joint is known to be asymmetric in both shape and dimension, the asymmetrical tray chosen in this study was found to fulfill this compromise with more difficulty.
Resumo:
Painful total hip replacement remains a challenging problem because of the large amount of possible diagnoses. We report about a 64-year-old female patient who was misdiagnosed during 4 years as psychiatric. She suffered of excruciating left retrotrochanteric pain after the implantation of a cementless total hip replacement and revision because of recurrent hip dislocations. Walking was limited to short distances using two crutches. The work-up at this time included the usual diagnoses and remained unsuccessful. No loosening, infection or malposition of the prosthesis could be found, and she had no neurologic deficits in her operated leg. An MRI was obtained to visualize the retrotrochanteric soft tissues and showed a tight scar surrounding the sciatic nerve, which was also compressed by an adjacent lipoma. Therefore, she was reoperated on to remove the lipoma and the scar tissue around the sciatic nerve. To decrease the risk of recurrent scarring around the sciatic nerve, an adhesion barrier was applied before closure. One year after the operation, the patient has no neurologic deficit, no more pain and is able to walk unlimited distances without crutches. Scar tissue around the sciatic nerve is frequently observed during revision surgery. However, we feel that sciatic nerve entrapment by scar tissue should be a part of the differential diagnosis of painful THR. MRI may be a useful tool to achieve this diagnosis.
Resumo:
L'objectiu d'aquest projecte és analitzar com optimitzar el temps total d'escala d'una aeronau comercial, per tal de reduir els costos que suposa que l'aeronau estigui en terra. L'anàlisi es realitza a partir de conèixer quines són les operacions mínimes necessàries que cal dur a terme durant el tumaround i en quin ordre convé realitzar- les perquè el temps total sigui mínim. També s'estudien quins són els mètodes científics ja proposats i quins són els usats en l'actualitat. Fruit de l'estudi es proposa un model que permeti reduir els costos derivats de retards, afegint un temps addicional a l'escala, a partir de dades recollides de l'activitat comercial diària a l’aeroport de Barcelona. Dels resultats obtinguts es conclou que interessa afegir un buffer que absorbeixi possibles incidents, però convé que sigui dividit segons la franja horària del dia, per tal que s'adapti al màxim a les necessitats de cada vol, enlloc d'afegir un mateix buffer a tots els vols de qualsevol hora.
Resumo:
Total shoulder arthroplasty (TSA) is an accepted and most successfully used treatment for different shoulder pathologies. Different risk factors for the failure of the prosthesis are known. A pathological scapular orientation, observed in elderly people or in patients suffering from neuromuscular diseases, could be a cause of failure, which has not been investigated yet. To test this hypothesis, a numerical musculoskeletal model of the glenohumeral joint was used to compare two TSA cases: a reference normal case and a case with a pathological anterior tilt of the scapula. An active abduction of 150° was simulated. Joint force, contact pattern, polyethylene and cement stress were evaluated for both cases. The pathological tilt slightly increased the joint force and the contact pressure, but also shifted the contact pattern. This eccentric contact increased the stress level within the polyethylene of the glenoid component and within the surrounding cement layer. This adverse effect occurred mainly during the first 60° of abduction. Therefore, a pathological orientation of the scapula may increase the risk of a failure of the cement layer around the glenoid component. These preliminary numerical results should be confirmed by a clinical study.
Resumo:
Background: Mobile-bearing knee replacements have some theoretical advantages over fixed-bearing devices. However, very few randomized controlled clinical trials have been published to date, and studies showed little clinical and subjective advantages for the mobile-bearing using traditional systems of scoring. The choice of the ideal outcome measure to assess total joint replacement remains a complex issue. However, gait analysis provides objective and quantifying evidences of treatment evaluation. Significant methodological advances are currently made in gait analysis laboratories and ambulatory gait devices are now available. The goal of this study was to provide gait parameters as a new objective method to assess total knee arthroplasty outcome between patients with fixed- and mobile-bearing, using an ambulatory device with minimal sensor configuration. This randomized controlled double-blind study included to date 14 patients: the gait signatures of four patients with mobile-bearing were compared to the gait signatures of nine patients with fixed-bearing pre-operatively and post-operatively at 6 weeks, 3 months and 6 months. Each participant was asked to perform two walking trials of 30m long at his/her preferred speed and to complete a EQ-5D questionnaire, a WOMAC and Knee Society Score (KSS). Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. A new method for a portable system for gait analysis has been developed with very encouraging results regarding the objective outcome of total knee arthroplasty using mobile- and fixed-bearings.
Resumo:
Background: Neuroblastoma is a paediatrictumour derived from the neural crest. Biochemical diagnosis and follow up rely on quantitation of urinary catecholamines (dopamine and noradrenaline) and their metabolites vanillylmandelic acid (VMA) and homovanillic acid (HVA) (gold-standard). When combined, these analyses have a sensitivity of 95%. However, they are clearly limited by inaccuracy of urine collection in young children and normalisation of catecholamine concentrations by creatininuria. Recent development in biochemical diagnosis of pheochromocytoma, another neural crest tumour found in adults, shows that plasmatic measurement of methoxylated catecholamines called metanephrines are more sensitive and specific than other biomarkers. Moreover, a study to determine the reference intervals for metanephrines in a pediatric population has recently been completed. The aim of this work is to describe the role of metanephrines monitoring in the follow up of neuroblastoma. Method: This retrospective study included patients with neuroblastoma in whom the following parameters were determined: plasma free and total metanephrines, plasma catecholamines, 24h urinary catecholamines and metanephrines in absolute value and corrected by creatinine, VMA and HVA at the diagnosis and during treatment at the University Hospital of Lausanne (Switzerland). Eleven patients aged between the first day of life and 7 years old were followed between 2005 and 2012. Clinical outcome and biochemical concentrations of the analytes were correlated. Results: At diagnosis, plasma free and total normetanephrines and methoxytyramine have a sensitivity of 100% compared to 85% for the actual gold standard. Metanephrine remain below the upper reference limit as expected since these tumours do not produce adrenaline. The relationship between biochemical markers and clinical outcome is illustrated graphically. Plasma or urinary normetanephrine and methoxytyramine correlate better with the history of the patient than VMA and HVA, as evaluated by ordinal logistic regression. Concentrations of analytes in urine show a better correlation with clinical events when the results are corrected by creatininuria. Conclusion: Normetanephrine and methoxytyramine reflect disease history in neuroblastoma patients and could play a significant role in the follow up of this type of tumour. Formal studies in a sufficient number of patients are needed to confirm this preliminary observation.
Resumo:
We describe the use of cable fixation and acute total hip replacement for acetabular fracture in the elderly. 12 patients with acetabular fractures, having a mean age of 79 (65-93) years, were treated with cable fixation and acute total hip arthroplasty. 8 were T-shaped fractures and 4 associated fractures of the posterior column and posterior wall. 1 patient died 5 months after surgery and the remaining 11 were followed for 2 years. All patients had a good clinical outcome. Radiographic assessment showed healing of the fracture and a satisfactory alignment of the cup without loosening. This surgical technique provides good primary fixation, stabilizes complex acetabular fractures in elderly patients with osteoporotic bone and permits early postoperative mobilization.