996 resultados para Personal Rapid Transit (PRT)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The susceptibility of 49 Mycobacterium tuberculosis clinical isolates to isoniazid (INH) and rifampisin (RIF) (28 multi-drug resistant-tuberculosis samples) was determined by a nitrate reductase assay (NRA) on blood agar. Agreement between the NRA and other testing methods was found to be 93.8% for both INH and RIF. The sensitivity, specificity, positive predictive value and negative predictive value for INH were 92.8%, 94.2%, 86.6% and 97%, respectively. The sensitivity, specificity, positive predictive value and negative predictive value for RIF were 90.4%, 96.4%, 95% and 93.1%. In conclusion, we show here that blood agar can be used effectively for the NRA test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An online scheme to assign Stenotrophomonas isolates to genomic groups was developed using the multilocus sequence analysis (MLSA), which is based on the DNA sequencing of selected fragments of the housekeeping genes ATP synthase alpha subunit (atpA), the recombination repair protein (recA), the RNA polymerase alpha subunit (rpoA) and the excision repair beta subunit (uvrB). This MLSA-based scheme was validated using eight of the 10 Stenotrophomonas species that have been previously described. The environmental and nosocomial Stenotrophomonas strains were characterised using MLSA, 16S rRNA sequencing and DNA-DNA hybridisation (DDH) analyses. Strains of the same species were found to have greater than 95% concatenated sequence similarity and specific strains formed cohesive readily recognisable phylogenetic groups. Therefore, MLSA appeared to be an effective alternative methodology to amplified fragment length polymorphism fingerprint and DDH techniques. Strains of Stenotrophomonas can be readily assigned through the open database resource that was developed in the current study (www.steno.lncc.br/).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objective of the current study was to compare two rapid methods, the BBL Mycobacteria Growth Indicator Tube (MGIT TM) and Biotec FASTPlaque TB TM (FPTB) assays, with the conventional Löwenstein-Jensen (LJ) media assay to diagnose mycobacterial infections from paucibacillary clinical specimens. For evaluation of the clinical utility of the BBL MGIT TM and FPTB assays, respiratory tract specimens (n = 208), with scanty bacilli or clinically evident, smear negative cases and non-respiratory tract specimens (n = 119) were analyzed and the performance of each assay was compared with LJ media. MGIT and FPTB demonstrated a greater sensitivity (95.92% and 87.68%), specificity (94.59% and 98.78%), positive predictive value (94.91% and 99.16%) and negative predictive value (96.56% and 90.92%), respectively, compared to LJ culture for both respiratory tract and non-respiratory tract specimens. However, the FPTB assay was unable to detect nontuberculous mycobacteria and few Mycobacterium tuberculosis complex cases from paucibacillary clinical specimens. It is likely that the analytical sensitivity of FPTB is moderately low and may not be useful for the direct detection of tuberculosis in paucibacillary specimens. The current study concluded that MGIT was a dependable, highly efficient system for recovery of M. tuberculosis complexes and nontuberculous mycobacteria from both respiratory and non-respiratory tract specimens in combination with LJ media.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although active personal dosemeters (APDs) are not used quite often in hospital environments, the possibility to assess the dose and/or dose rate in real time is particularly interesting in interventional radiology and cardiology (IR/IC) since operators can receive relatively high doses while standing close to the primary radiation field.A study concerning the optimization of the use of APDs in IR/IC was performed in the framework of the ORAMED project, a Collaborative Project (2008-2011) supported by the European Commission within its 7th Framework Program. This paper reports on tests performed with APDs on phantoms using an X-ray facility in a hospital environment and APDs worn by interventionalists during routine practice in different European hospitals.The behaviour of the APDs is more satisfactory in hospitals than in laboratories with respect to the influence of the tube peak high voltage and pulse width, because the APDs are tested in scattered fields with dose equivalent rates generally lower than 1 Sv.h(-1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Disseny i implementació de la base de dades per a una empresa de selecció de personal

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ponència presentada a la Jornada sobre plans d'autoprotecció

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ponència presentada a la Jornada sobre plans d'autoprotecció

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The microplate nitrate reductase assay (MNRA) and the rezasurin microtitre assay (REMA) were used for the susceptibility testing of 73 clinical isolates and the results were compared with those that were obtained using the Bactec 460 TB and Bactec MGIT 960 systems. The REMA and the MNRA were performed in 96-well plates. For the REMA, the concentrations of isoniazid (INH) and rifampicin (RIF) ranged from 1.0-0.01 µg/mL and 2.0-0.03 µg/mL, respectively. For the MNRA, the INH concentration was between 1.0-0.03 µg/mL and the RIF concentration was between 2.0-0.06 µg/mL. For the MNRA, the sensitivity, specificity, positive predictive value, negative predictive value and INH/RIF agreement were 100/95.6, 97.6/100, 96.8/100, 100/98 and 98.6/98.6, respectively, and for the REMA, they were 100/91.3, 90.4/100, 88.5/100, 100/96.1 and 94.5/97.2, respectively. Our data suggest that these two rapid, low-cost methods may be inexpensive, alternative assays for the rapid detection of multidrug resistant tuberculosis in low-income countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Boletín semanal para profesionales sanitarios de la Secretaría General de Salud Pública y Participación Social de la Consejería de Salud

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human Immunodeficiency Virus continues to be a pandemic. Spain is one of the European countries with the highest incidence of HIV. Within Catalonia, Spain many projects have been implemented with the intention of improving HIV knowledge and lowering the incidence. HIV knowledge is also known to have a positive effect on lowering stigma and discrimination of the people living with HIV. However, few studies study the distribution of HIV knowledge and its association to HIV status, age, sex, geographical zone of origin and level of education within the same study. Objectives: To identify if HIV knowledge is associated with HIV status, age, sex, geographical zone of origin and level of education. Method: Quantitative, cross-sectional, centre-based study comprising of people receiving an HIV test in Catalonia, Spain. Data will be collected from the 11 HIV Non-Governmental Organisations in Catalonia, Spain. The Brief HIV Knowledge Scale will be used to assess HIV knowledge; information from the HIV test session will be used to assess HIV status, age, sex, geographic zone of origin and level of education. The association between HIV knowledge and the afore mentioned variables will then be calculated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Base de dades realitzada en Oracle per controlar i ajustar les ofertes de de treball que es reben de les empreses i les demandes de feina i currículums que presenten els treballadors. Tot l'accés a les dades es realitza mitjançant procediments emmagatzemats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este documento refleja el trabajo realizado durante el diseño e implementación de una base de datos relacional y un almacén de datos para una empresa de gestión de personal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Una empresa de selecció de personal vol incorporar un sistema per controlar i ajustar les ofertes de feina que rep de les empreses i les demandes de feina i currículums que presenten els treballadors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The performances of two rapid tests and a standard serological test for the diagnosis of visceral leishmaniasis (VL) were compared using sera from 193 patients with VL and 85 controls. The Kala-Azar Detect®, IT-LEISH® and IFI-LH® assays showed sensitivities of 88.1%, 93.3% and 88.6%, respectively, and specificities of 90.6%, 96.5% and 80%, respectively. The sensitivity values were similar for both rapid tests, but the specificity and positive predictive values of IT-LEISH® were higher than the corresponding values for IFI-LH®. Both rapid tests showed satisfactory performances and can be used in primary health care settings; however, IT-LEISH® permits the use of whole blood, making this assay more suitable for bedside diagnosis.