989 resultados para PID tuning. PID auto-tuning. Evaluation of control loops. Relay method. PID controllers


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Acinetobacter baumannii is a strictly aerobic bacterium which causes severe infections, however its pathogenic characteristics are not well defined. Thirteen A. baumannii strains isolated from urine of hospitalized and nonhospitalized patients with different ages were investigated for the presence of virulence factors. The isolates belonged to biotypes 2, 6, and 9 and were sensitive to imipenem. The majority of them showed resistance to amikacin, ceftazidime, ceftriaxone, ciprofloxacin, gentamicin, norfloxacin, and trimethoprim-sulfamethoxazole. None of A. baumannii strains presented genes codifying for 17 different virulence factors previously described in uropathogenic Escherichia coli, when tested by polymerase chain reaction (PCR). Nine isolates agglutinated human group AB erythrocytes, in presence of mannose, but none of them agglutinated group O erythrocytes. Adherence to polystyrene was observed in 7 isolates, and this result did not correlate with that obtained in hemagglutination assay. All the isolates were able to grow in iron-limiting conditions, showing that A. baumannii produces some type of siderophore. However, the genes iutA and fyuA, from iron uptake system of E. coli and Yersinia sp., respectively, were not present in the isolates, suggesting the presence of a different type of siderophore. The fimbriae of A. baumannii strains that mediates the adherence are possibly mannose-resistant, eventhough the mechanism of adherence to human epithelial cells still remains to be elucidated.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Specific IgG and IgM responses to soluble egg antigen (SEA) and keyhole limpet haemocyanin (KLH) were measured by ELISA in patients with acute and chronic schistosomiasis. The tests based upon IgM and IgG antibodies responses to KLH presented the best diagnostic discrimination, and can be used in conjunction with clinical and epidemiological data to the differential diagnosis of acute schistosomiasis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Iatrogenous transmission of Trypanosoma cruziby blood transfusion was suggested as a potential risk by Pellegrino (1949). Seropositive blood donors in Mexico were first reported in 1978, however, limited information is available due to small sampling, the use of heterogeneous serologic assays, and geographically limited studies. A wide survey carried out in 18 out of the 32 states of Mexico, showed a national mean of 1.6% seropositive among 64,969 donors, ranging from 0.2 to 2.8%. In the present study, we have screened 43,048 voluntary blood donors in a period of five years at the Instituto Nacional de Cardiología I. Chávez, a concentration hospital located in Mexico city which serves mainly the metropolitan area and accepts from all over the country. Standardized ELISA and IIF were used to identify seropositive individuals in addition to hemoculture, PCR and standard 12 lead ECG tests that were applied to a group of seropositive patients (29/161). The result showed a seropositivity of 0.37% (161/43,048). From the group of seropositive individuals 40% (12/29) were potential carriers of T. cruzi at the donation time and 5/29 had subclinical ECG abnormalities. Parasitological tests performed in 70 erythrocyte and platelet fractions from seropositive units (70/161) showed negative results. Our findings strongly support T. cruzi screening in the transfusion medicine practice and identify subclinical heart disease among seropositive blood donors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performances of ELISA assays with different antigen preparations, such as Leishmania amazonensis or L. chagasi lysates and the recombinant antigens rK-39 and rK-26, were compared using sera or eluates from dried blood collected on filter paper to detect anti-Leishmania antibodies in dogs from a visceral leishmaniasis-endemic area in Brazil. Of 115 IFAT-reactive dogs at 1:40 titre, 106 (92.2%) were positive in parasitological exams (skin and/or spleen). These animals were compared to healthy animals (n = 25), negative for IFAT at a titre of 1:40 and parasitological exams. The sensitivities of crude and recombinant antigens were similar and remarkably high for both sera and eluates (97-100%). Specificity was higher than 96% for sera and eluates for different antigens, except for L. chagasi antigen using eluates (88%). Concordance values among the tests were higher either for sera or eluates (J = 0.95-1.00). High concordances were observed between sera and eluates tested with different antigens (kappa = 0.93-0.97). Crude and recombinant antigens identified different clinical phases of canine leishmaniasis. These results show that eluates could be used in canine surveys to identify L. chagasi infection. Recombinant antigens added little when compared to crude antigen in identifying positive dogs. Cross-reactivity with other diseases whose distribution often overlaps VL-endemic areas is a limitation of crude antigen use however.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study was conducted to compare among the most recent generation of five screening tests licensed in Argentina, in order to evaluate which of the tests has the best sensitivity for detection of antibodies against hepatitis C virus (HCV). The tests analyzed were: Detect-HCV™ (3.0) Biochem ImmunoSystems, Canada; Hepatitis C EIA Wiener Lab., Argentina; Equipar HCV Ab, Italy; Murex HCV 4.0, UK and Serodia-HCV particles agglutination test, Japan. The results obtained showed high discrepancy between the different kits used and show that some of the tests assessed have a low sensitivity for anti-HCV detection in both chronic infections and early seroconversion, and indicate that among the commercially available kits in Argentina, Murex HCV 4.0 (UK) and Serodia-HCV particles agglutination test (Japan) have the best sensitivity for HCV screening. Although the sensitivity of the assays is the first parameter to be considered for blood screening, more studies should be carried out to assess the specificity of such assays.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this study it was compared the MAS-100 and the Andersen air samplers' performances and a similar trend in both instruments was observed. It was also evaluated the microbial contamination levels in 3060 samples of offices, hospitals, industries, and shopping centers, in the period of 1998 to 2002, in Rio de Janeiro city. Considering each environment, 94.3 to 99.4% of the samples were the allowed limit in Brazil (750 CFU/m³). The industries' results showed more important similarity among fungi and total heterotrophs distributions, with the majority of the results between zero and 100 CFU/m³. The offices' results showed dispersion around 300 CFU/m³. The hospitals' results presented the same trend, with an average of 200 CFU/m³. Shopping centers' environments showed an average of 300 CFU/m³ for fungi, but presented a larger dispersion pattern for the total heterotrophs, with the highest average (1000 CFU/m³). It was also investigated the correlation of the sampling period with the number of airborne microorganisms and with the environmental parameters (temperature and air humidity) through the principal components analysis. All indoor air samples distributions were very similar. The temperature and air humidity had no significant influence on the samples dispersion patterns.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A dot enzyme-linked immunosorbent assay (dot-ELISA) was standardized using excretory-secretory antigens of Toxocara canis for the rapid immunodiagnosis of human toxocariasis. Thirty patients with clinical signs of toxocariasis, 20 cases with other parasitic diseases, and 40 healthy subjects were tested. A total of 0.2 ng of antigen per dot, serum dilution of 1:160 and dilution conjugate of 1:1000 were found optimal. The sensitivity and specificity of the assay were 100 and 95%, respectively. Comparable sensitivity of dot-ELISA and the standard ELISA was obtained, but only 3 cross-reactions occurred in the dot-ELISA, compared with 6 in the standard ELISA. Dot-ELISA is simple to perform, rapid, and low cost. Large-scale screening studies should be done to evaluate its usefulness under field conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to demonstrate the DNA of Paracoccidioides brasiliensis in human serum samples of patients with paracoccidioidomycosis using the polymerase chain reaction (PCR). The diagnosis of paracoccidioidomycosis (PCM) was defined by microscopic observation of the fungus on direct exam or histopathology, culture, and serological positivity. DNA from serum of 33 patients with PCM was extracted and submitted to nested-PCR using primers from the gp 43 gene. Only one sample was positive on nested-PCR. We conclude that the prevalence of fungemia in patients with different clinical forms of PCM is low, limiting the use of serum DNA detection as an alternative diagnostic tool.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In recent years, the development of new tools to gather field information about vector ecological parameters has increased. This report evaluated the BG-Sentinel Trap (BGS-Trap), a promising new attempt to improve collection of the dengue vector, Aedes aegypti. The efficacy of the BGS-Trap was compared with the CDC backpack aspirator, one of the commonest used methods for capturing adult mosquitoes. BGS-Traps captured significantly more Ae. aegypti males (chi2 = 21.774, df = 1, P < 0.05) and females (chi2 = 56.007, df = 1, P < 0.05) than CDC aspirator during all days of field collection. However, CDC aspirator was significantly more efficient to capture Culex quinquefasciatus males (chi2 = 5.681, df = 1, P < 0.05) and females (chi2 = 6.553, df = 1, P < 0.05). BGS-Traps captured host-seeking females (varying between 68.75 to 89.8%) in detriment of females in other behavioral and physiological stages. BGS-Traps proved to be efficient and can be used for monitoring adult mosquito populations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Determination of seric levels of adenosine deaminase (ADA), an enzyme produced by monocytes/macrophages and lymphocytes, has been used in the diagnosis of human tuberculosis (TB). In the present study, ADA seric activity was evaluated comparatively to the comparative tuberculin test in the diagnosis of bovine tuberculosis. Two hundred fifty-six cattle were classified by origin and by the comparative tuberculin test as TB-positive animals (n = 52, from herds where the Mycobacterium bovis had previously been isolated), and TB-negative animals (n = 204, TB-free herds). The mean ADA seric value from the TB-positive group (4.45 ± 2.33 U/L) was significantly lower (p = 0.008) than that observed in sera from the TB-negative group (6.12 ± 4.47 U/L). When animals from a herd with clinical cases of enzootic bovine leukosis of TB-negative group were withdrawn from analysis, the mean ADA seric values of TB-negative group (5.12 ± 3.75 U/L) was not significantly different anymore from that of the TB-positive group (p = 0.28). There was no agreement in the diagnosis of bovine TB between comparative tuberculin test and determination of ADA seric values, using two different cutoff points, being 6.12 U/L and 15.0 U/L, (kappa = -0.086 and kappa = -0.082, respectively). In conclusion, the determination of ADA seric activity was not a good auxiliary test for bovine TB, because it was not able to distinguish between TB-positive and TB-negative animals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A study was carried out to compare the performance of a commercial method (MGIT) and four inexpensive drug susceptibility methods: nitrate reductase assay (NRA), microscopic observation drug susceptibility (MODS) assay, MTT test, and broth microdilution method (BMM). A total of 64 clinical isolates of Mycobacterium tuberculosis were studied. The Lowenstein-Jensen proportion method (PM) was used as gold standard. MGIT, NRA, MODS, and MTT results were available on an average of less than 10 days, whereas BMM results could be reported in about 20 days. Most of the evaluated tests showed excellent performance for isoniazid and rifampicin, with sensitivity and specificity values > 90%. With most of the assays, sensitivity for ethambutol was low (62-87%) whereas for streptomycin, sensitivity values ranged from 84 to 100%; NRA-discrepancies were associated with cultures with a low proportion of EMB-resistant organisms while most discrepancies with quantitative tests (MMT and BMM) were seen with isolates whose minimal inhibitory concentrations fell close the cutoff. MGIT is reliable but still expensive. NRA is the most inexpensive and easiest method to perform without changing the organization of the routine PM laboratory performance. While MODS, MTT, and BMM, have the disadvantage from the point of view of biosafety, they offer the possibility of detecting partial resistant strains. This study shows a very good level of agreement of the four low-cost methods compared to the PM for rapid detection of isoniazid, rifampicin and streptomycin resistance (Kappa values > 0.8); more standardization is needed for ethambutol.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The increasing number of pertussis cases reported on the last twenty years and the existence of new acellular vaccines reinforce the need of research for experimental models to assure the quality of available pertussis vaccines. In this study, allotments of whole-cell and acellular pertussis vaccines were tested through the Intranasal Challenge Model (INM) using conventional NIH mice. The results have been compared to those achieved by the "Gold standard" Intracerebral Challenge Model (ICM). In contrast to ICM, INM results did not show intralaboratorial variations. Statistical analysis by Anova and Ancova tests revealed that the INM presented reproducibility and allowed identification and separation of different products, including three-component and four-component accellular pertussis vaccines. INM revealed differences between pertussis vaccines. INM provides lower distress to the mice allowing the reduction of mice number including the possibility of using conventional mice (less expensive) under non-aseptic environment. Thus, INM may be used as an alternative method of verifying the consistence of allotment production, including acellular pertussis vaccines.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The best way to appraise the size of abdominal organs remains undefined. Herein we compare the size of liver and spleen in hepatosplenic schistosomiasis using clinical and ultrasound (US) examination, and the size of the organs measured by US with their visualization below the costal margin ("palpable by US"). For this study, 411 individuals from an endemic area for schistosomiasis mansoni in Brazil have been selected. We found that palpable spleens and left liver lobes are larger than non palpable ones. Also, 23% of normal spleens measured by US were palpable on clinical examination, and 22% of spleens increased in size on US were non palpable. A total of 21% of normal spleens were "palpable by US". We also found 54% of normal sized right liver lobes palpable on clinical examination, whilst 54% of the increased livers, measured by US, were non palpable. About 76% of normal right liver lobes were "palpable by US". We conclude that the association of clinical, ultrasound and magnetic resonance imaging (MRI) examinations, in the near future, should give the investigators the necessary tools to perform a more accurate clinical diagnosis of hepatosplenic schistosomiasis mansoni.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evaluation of hepatic fibrosis is usually performed by histopathological examination of biopsies. However, this is an invasive and potentially dangerous procedure. Several studies have proposed serum biological markers of hepatic fibrosis. This communication evaluates the use of serum cytokines as markers of hepatic fibrosis in hepatitis C, schistosomiasis, and co-infection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cryptococcus neoformans is an encapsulated fungal organism that can cause disease in apparently immunocompetent, as well as immunocompromised, hosts. Since 1930, successive subculture has been used to preserve C. neoformans isolates in our Fungus Collection. In the 1970s, some of these Fungus Collection samples were selected to be subjected to a different methods of maintenance - that of lyophilized. Our objective was to analyze C. neoformans isolates in order to make a comparative evaluation between these two methods of preservation. The overall aim of this study was to qualify the preservation technique used in our mycology laboratory since the technique used might affect the survival, stability and purity of the primary isolates in culture. The samples were analyzed using classical mycology methods and using the randomly amplified polymorphic DNA technique In the analysis of phenotypes and genotypes, the typical characteristics of C. neoformans were found to differ in relation to the different methods of preservation employed. The aim of this study was to demonstrate the importance of selecting the appropriate method of preservation for fungus collections. This selection can affect the survival and purity of the cultures, and preserve the stability of their physiological, biochemical, and genetic characteristics.