933 resultados para On-line control process for attributes


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, we examine the nonlinear control method based on the saturation phenomenon and of systems coupled with quadratic nonlinear ties applied to a shear-building portal plane frame foundation that supports an unbalanced direct cut-rent with limited power supply (non-ideal system). We analyze the equations of motion by using the method of averaging and numerical simulation. The interaction of the non-ideal structure with the saturation controller may lead to the occurrence of interesting phenomena during the forward passage through the several resonance states of the systems. Special attention is focused on passage through resonance when the non-ideal excitation frequency is near the portal frame natural frequency and when the non-ideal system frequency is approximately twice the controller frequency (two-to-one internal resonance).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, we deal with a micro electromechanical system (MEMS), represented by a micro-accelerometer. Through numerical simulations, it was found that for certain parameters, the system has a chaotic behavior. The chaotic behaviors in a fractional order are also studied numerically, by historical time and phase portraits, and the results are validated by the existence of positive maximal Lyapunov exponent. Three control strategies are used for controlling the trajectory of the system: State Dependent Riccati Equation (SDRE) Control, Optimal Linear Feedback Control, and Fuzzy Sliding Mode Control. The controls proved effective in controlling the trajectory of the system studied and robust in the presence of parametric errors.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A method has been developed for extraction and determination of carbofuran in milk. The method involved direct injection of raw milk on to a human serum albumin dimethyloctyl-silica gel (HSA-Cs) column and the use of 80:20 (v/v) 0.01 M phosphate buffer pH 5.5 - acetonitrile as mobile phase. UV spectrophotometric detection was performed at 220 nm. Identification was based on retention time. Quantification was performed by automatic peak-area determination and was calibrated by use of an external standard.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The literature shows conflicting results regarding older adults' (OA) postural control performance. Differing task demands amongst scientific studies may contribute to such ambiguous results. Therefore, the purpose of this study was to examine the performance of postural control in older adults and the relationship between visual information and body sway as a function of task demands. Old and young adults (YA) maintained an upright stance on different bases of support (normal, tandem and reduced), both with and without vision, and both with and without room movement. In the more demanding tasks, the older adults displayed greater body sway than the younger adults and older adults were more influenced by the manipulation of the visual information due to the room movement. However, in the normal support condition, the influence of the moving room was similar for the two groups. These results suggest that task demand is an important aspect to consider when examining postural control in older adults. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rhizoctonia foliar blight (RFB) of soybean [Glycine max (L.) Merrill] occurs in many tropical and subtropical regions, causing yield reductions of up to 70% and in Brazil, up to 60%. The disease is caused by Rhizoetonia solani AG1-IA and AG1-IB, and by AG2-3 in Japan. RFB occurs in the North, Northeast and Mid-west regions of Brazil. Chemical control remains the only effective method of controlling RFB, but its efficiency depends upon environmental conditions. In this study, 18 fungicides, salicylic acid (SA) and acibenzolar-s-methyl (ASM) were evaluated on R. solani AG1-IA in vitro, by mycelial growth rating and estimating effective concentration for 50% (EC 50) and 90% (EC 90) inhibition of mycelial growth, and in vivo by reduction of disease severity on soybean plants in greenhouse conditions. Mycelial growth was strongly inhibited by the fungicides pyraclostrobin + boscalid and fludioxonil. Preventive fungicide applications were the most effective. Strobilurins were more efficient both in preventive and curative applications. Best results with plant resistance activators were obtained with SA (2.5 mM) sprayed at 20 d before inoculation and with ASM (12.5 mg a.i. l(-1)) 10 d before inoculation. (c) 2005 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work, the problem in the loads transport (in platforms or suspended by cables) it is considered. The system in subject is composed for mono-rail system and was modeled through the system: inverted pendulum, car and motor and the movement equations were obtained through the Lagrange equations. In the model, was considered the interaction among of the motor and system dynamics for several potencies motor, that is, the case studied is denominated a non-ideal periodic problem. The non-ideal periodic problem dynamics was analyzed, qualitatively, through the comparison of the stability diagrams, numerically obtained, for several motor torque constants. Furthermore, one was made it analyzes quantitative of the problem through the analysis of the Floquet multipliers. Finally, the non-ideal problem was controlled. The method that was used for analysis and control of non-ideal periodic systems is based on the Chebyshev polynomial expansion, in the Picard iterative method and in the Lyapunov-Floquet transformation (L-F trans formation). This method was presented recently in [3-9].

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports the identification of di- and triglycosylated flavonoids from Sorocea bomplandii (Moraceae) by liquid chromatography coupled on-line to nuclear magnetic resonance (LC-NMR). These glycosylated flavonoids may be used as a taxonomic marker in future work. (C) 2002 Elsevier B.V. B.V All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to histomorphologically evaluate (in dog's teeth) the influence of tooth movement in the healing of chronic periapical lesions. Thirty roots of incisors and premolars of two dogs (1-year-old) were used in this research. After pulpectomy, the root canals remained exposed to the oral environment for 6 months for achievement of periapical lesions. Twenty root canals were biomechanically prepared and received a calcium hydroxide dressing for 14 days before being filled with gutta-percha points and Sealapex sealer. After root canal treatment, some incisors were submitted to orthodontic movement, whereas the other roots remained without orthodontic movement. The orthodontic appliance was removed at 5 months and 15 days after treatment, the dogs were killed 15 days later and the specimens were prepared for histomorphological analysis. The results showed that the orthodontic movement delayed, but did not hinder, the periapical healing process. (J Endod 2006;32:115-119)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Freshly harvested lemons [(Citrus limon (L.) Burm)] were dipped 3 min in water with and without imazalil (IMZ) at 50, 100, and 200 ppm at 50 degrees C and at 1000 ppm IMZ at 20 degrees C. Following treatments fruit were kept at 9 degrees C and 90%-95% relative humidity (RH) for 13 weeks and an additional week at 21 degrees C and ca. 75% RH, to simulate a marketing period (SMP). No decay control was observed with fruit dipped in water at 50 degrees C. In contrast, IMZ treatments provided 90%-96% control of Penicillium rots during cold storage and SMP. Fungi other than Penicillium spp. were also found in all samples as differences among treatments were negligible. IMZ treatment caused some external damage to the fruit (peel browning), and the percentage of damaged fruit was related to the amount of active ingredient (AI) present in it. Dipping in 200 or 1000 ppm IMZ promoted off-flavor development after 10 weeks of storage, and fruit were judged to be unacceptable for consumption after 13 weeks of cold storage. After 1000 ppm IMZ dipping at 20 degrees C, residue concentration in fruit was 8.20 ppm; this value doubled that found in a previous investigation on lemons treated with comparable IMZ levels. Residue concentrations in fruit after treatment at 50 degrees C was strictly related to the amount of fungicide employed. After 13 weeks Al residues in fruit decreased to average ca. 35% of the initial values. During the 1 week SMP, residue levels decreased by a further ca. 25%. It was concluded that it is possible to achieve significant control of decay in lemons during longterm storage by dipping fruit in 50 ppm IMZ mixtures at 50 degrees C. Such treatment should be advised to remarkably reduce potential pollution in the environment due to packinghouse wastewater disposal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A flow-injection (FI) system to match concentrations was used as an auto-diluter in multielement determination by inductively coupled plasma-mass spectrometry (ICP-MS). The flow system comprised loop-based injection or a timed valve that introduced a variable sample volume info a spray chamber through a standard Meinhard nebulizer of an ICP-MS. Routinely analyzed samples such as water, plant, and steel were selected. The accuracy of multielement determination was checked against water standard reference material from the National Institute of Standards and Technology (1643d), plant standard reference material from the National Bureau of Standards (1572 citrus leaves), and steel standard reference material from the National Bureau of Standards (AISI 4340). The measuring system was calibrated with a multielement solution, yielding a linear plot with good precision [relative standard deviation (RSD) < 3%, n = 12]. The results were in agreement at a 95% confidence level with the certified values for the reference materials and also with those obtained by continuous aspiration and by (FI) with a discrete volume. (C) 1999 John Wiley & Sons, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simultaneous method for the trace determination of acidic, neutral herbicides and their transformation products in estuarine waters has been developed through an on-line solid-phase extraction method followed by liquid chromatography with diode array and mass spectrometric detection. An atmospheric pressure chemical ionization (APCI) interface was used in the negative ionization mode after optimization of the main APCI parameters. Limits of detection ranged from 0.1 to 0.02 ng/ml for 50 mi of acidified estuarine waters preconcentrated into polymeric precolumns and using time-scheduled selected ion monitoring mode. Two degradation products of the acidic herbicides (4-chloro-2-methylphenol and 2,4-dichlorophenol) did not show good signal response using APCI-MS at the concentration studied due to the higher fragmentor voltage needed for their determination For molinate and the major degradation product of propanil, 3,4-dichloroaniline, positive ion mode was needed for APCI-MS detection. The proposed method was applied to the determination of herbicides in drainage waters from rice fields of the Delta del Ebro (Spain). During the S-month monitoring of the herbicides, 8-hydroxybentazone and 4-chloro-2-methylphenoxyacetic acid were successively found in those samples. (C) 2000 Elsevier B.V. B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An automated on-line solid phase extraction procedure followed by liquid chromatography with diode array detection was investigated for the determination of different classes of pesticides in water samples containing varied amount of humic substances. The different pesticides used were: carbendazin, carbofuran, atrazine, diuron, propanil, molinate, alachlor, parathion-ethyl, diazinon, trifluralin and the degradation products deisopropylatrazine and deethylatrazine. Humic substances extracted from a Brazilian sediment were used from 5 to 80 mg/l and their influence on recoveries was evaluated in neutral and acidic media. Recoveries higher than 70% were obtained for all the pesticides, from the preconcentration of 75 mi of aqueous sample fortified at 2 ng/ml using precolumns packed with PLRP-S. Good recoveries were obtained at neutral pH for most of the analytes up to 40 mg/l of humic acid. Only at 80 mg/l the recoveries were significantly affected, both at acidic and neutral pH. The method was applied to the determination of pesticides in river water spiked at 0.1 to 1 ng/ml. Detection limits obtained for water containing 10 mg/l of humic acid were between 0.05 and 0.3 ng/ml.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An on-line dialysis flow system coupled to inductively coupled plasma mass spectrometry to determine trace elements in serum samples by isotope dilution is presented. Isotope dilution was performed on samples incubated with enriched Cu-65, Zn-66, Se-77 and Pb-206 for 24 h at 36degreesC prior to dialysis to quantified total element concentrations. The sample and acceptor solutions flowed through the dialysis unit with cellophane membrane placed in between the compartments. The serum sample (1 mL) was left to recycle in a closed path while the acceptor solution was continuously pumped along the dialyzer channel and through a cationic AG50W X-8 resin column. After 10 min, around 70% of Na, K and Cl migrate from the sample. Three replicate injections of 0.1 mL were performed for the clean sample after each separation step. The on-line coupling of the dialyzer to ICP-MS allowed isotope dilution for total element determination either in the cleaned sample or by eluting the cations retained in the resin to be carried out. Results demonstrated no matrix effects from alkaline elements or spectral interference from ArNa+ on Cu-63, ArCl+ on Se-77 and (SO2+)-S-34 on Zn-66. The precision of isotope ratio measurements for Cu and Zn was around 1% and for Se and Pb was around 2.5%. The values found for the reference serum sample IMEP-17 were in good agreement with the certified values for Cu, Zn and Se.