847 resultados para Ocular Microtremor


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The kinin family are a group of bioactive peptides that are closely involved in the modulation of vascular inflammation and local injury. We have demonstrated here, for the first time, a link between kinin activity and contact lens wear. Protein extracts from daily and extended wear etafilcon A, Group IV, Acuvue lenses (Vistakon), were analysed by counter immunoelectrophoresis. In this way, kinin activity associated with contact lens wear was detected. High molecular weight kininogen was used as the marker protein. In contrast, no kinin activity was detected in the non-lens wearing normal eye. © 2002 British Contact Lens Association. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiovascular disease and stroke continue to be the chief causes of death in developed countries and one of the leading causes of visual impairment. The individual with systemic hypertension may remain asymptomatic for many years. Systemic mortality and morbidity are markedly higher for hypertensives than normotensives, but can be significantly reduced by early diagnosis and then efficient management. However, the ability of Optometrists to detect and appropriately refer systemic hypertensives remains generally poor. This review examines the disease, its effects and detection by observation of the retinal signs, particularly those considered to be pre-malignant. Previous methods of classifying retinal hypertensive signs are discussed along with more recent image analysis techniques. The role of the optometrist in detecting, monitoring and appropriate referral of systemic hypertensives is discussed in relation to current research. (C) 2001 The College of Optometrists. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To assess systemic and ocular vascular reactivity in response to warm and cold provocation in untreated patients with primary open-angle glaucoma and normal control subjects. METHODS. Twenty-four patients with primary open-angle glaucoma and 22 normal control subjects were subjected to a modified cold pressor test involving immersion of the right hand in 40°C warm water followed by 4°C cold water exposure, and finger and ocular blood flow were assessed by means of peripheral laser Doppler flowmetry and retinal flowmetry, respectively. Finger and body temperature as well as intraocular pressure, systemic blood pressure, systemic pulse pressure, heart rate, and ocular perfusion pressure were also monitored. RESULTS. The patients with glaucoma demonstrated an increase in diastolic blood pressure (P = 0.023), heart rate (P = 0.010), and mean ocular perfusion pressure (P = 0.039) during immersion of the tested hand in 40°C water. During cold provocation, the patients demonstrated a significant decrease in finger (P = 0.0003) and ocular blood flow (the parameter velocity measured at the temporal neuroretinal rim area; P = 0.021). Normal subjects did not demonstrate any blood flow or finger temperature changes during immersion of the tested hand in 40°C water (P > 0.05); however, they exhibited increases in systolic blood pressure (P = 0.034) and pulse pressure (P = 0.0009) and a decrease in finger blood flow (P = 0.0001) during cold provocation. In normal subjects, the ocular blood flow was unchanged during high- and low-temperature challenge. CONCLUSIONS. Cold provocation elicits a different blood pressure, and ocular blood flow response in patients with primary open-angle glaucoma compared with control subjects. These findings suggest a systemic autonomic failure and ocular vascular dysregulation in POAG patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The primary aim of this thesis was to investigate the in vivo ocular morphological and contractile changes occurring within the accommodative apparatus prior to the onset of presbyopia, with particular reference to ciliary muscle changes with age and the origin of a myopic shift in refraction during incipient presbyopia. Commissioned semi-automated software proved capable of extracting accurate and repeatable measurements from crystalline lens and ciliary muscle Anterior Segment Optical Coherence Tomography (AS-OCT) images and reduced the subjectivity of AS-OCT image analysis. AS-OCT was utilised to document longitudinal changes in ciliary muscle morphology within an incipient presbyopic population (n=51). A significant antero-inwards shift of ciliary muscle mass was observed after 2.5 years. Furthermore, in a subgroup study (n=20), an accommodative antero-inwards movement of ciliary muscle mass was evident. After 2.5 years, the centripetal response of the ciliary muscle significantly attenuated during accommodation, whereas the antero-posterior mobility of the ciliary muscle remained invariant. Additionally, longitudinal measurement of ocular biometry revealed a significant increase in crystalline lens thickness and a corresponding decrease in anterior chamber depth after 2.5 years (n=51). Lenticular changes appear to be determinant of changes in refraction during incipient presbyopia. During accommodation, a significant increase in crystalline lens thickness and axial length was observed, whereas anterior chamber depth decreased (n=20). The change in ocular biometry per dioptre of accommodation exerted remained invariant after 2.5 years. Cross-sectional ocular biometric data were collected to quantify accommodative axial length changes from early adulthood to advanced presbyopia (n=72). Accommodative axial length elongation significantly attenuated during presbyopia, which was consistent with a significant increase in ocular rigidity during presbyopia. The studies presented in this thesis support the Helmholtz theory of accommodation and despite the reduction in centripetal ciliary muscle contractile response with age, primarily implicate lenticular changes in the development of presbyopia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To quantify the end-of-day silicone-hydrogel daily disposable contact lens fit and its influence of on ocular comfort, physiology and lens wettability. Methods: Thirty-nine subjects (22.1. ±. 3.5 years) were randomised to wear each of 3 silicone-hydrogel daily-disposable contact lenses (narafilcon A, delefilcon A and filcon II 3), bilaterally, for one week. Lens fit was assessed objectively using a digital video slit-lamp at 8, 12 and 16. h after lens insertion. Hyperaemia, non-invasive tear break-up time, tear meniscus height and comfort were also evaluated at these timepoints, while corneal and conjunctival staining were assessed on lens removal. Results: Lens fit assessments were not different between brands (P > 0.05), with the exception of the movement at blink where narafilcon A was more mobile. Overall, lag reduced but push-up speed increased from 8 to 12. h (P <. 0.05), but remained stable from 12 to 16. h (P > 0.05). Movement-on-blink was unaffected by wear-time (F = 0.403, P = 0.670). A more mobile lens fit with one brand did not indicate that person would have a more mobile fit with another brand (r = -0.06 to 0.63). Lens fit was not correlated with comfort, ocular physiology or lens wettability (P > 0.01). Conclusions: Among the lenses tested, objective lens fit changed between 8. h and 12. h of lens wear. The weak correlation in individual lens fit between brands indicates that fit is dependent on more than ocular shape. Consequently, substitution of a different lens brand with similar parameters will not necessarily provide comparable lens fit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To explore the repeatability of lower-order and higher-order ocular aberrations measured in patients with keratoconus. Methods: The IRX-3 (Imagine Eyes, Paris, France) aberrometer was used to record lower-order and higher-order aberrations in 31 eyes of 31 patients with keratoconus. Four monocular measurements were taken consecutively for each patient. The aberrometry data were analysed up to the 5th Zernike order for a 4-mm pupil diameter. The data were evaluated using repeated-measures anova and Friedman analyses. Repeatability was analysed using within-subject standard deviation (SW) and the repeatability limit (r) calculated as 1.96 ×√2×Sw. Results: Of the 11 aberration terms evaluated, the repeatability of Z (2,0) (mean= 1.36μm; SW=0.09μm; r=0.26μm); Z (2,±2) RMS (mean=1.05μm; SW= 0.09μm; r=0.24μm) and Z (4,0) aberrations (mean=0.34μm; SW=0.09 μm; r=0.24μm) showed the highest variability. In contrast, Z (3,±1) RMS aberrations (mean=0.85μm; SW=0.06μm; r=0.16μm) and Z (4,±2) RMS aberrations (mean=0.40μm; SW=0.07μm; r=0.18μm) showed comparatively better repeatability. Conclusions: The lower-order and higher-order aberrations measured in this group of keratoconic patients showed higher levels of variability compared to previous investigations of visually-normal subjects. These results may be of interest to eyecare practitioners involved in the design and fitting of aberration-controlling contact lenses for patients with keratoconus. © 2011 The College of Optometrists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The poor retention and efficacy of instilled drops as a means of delivering drugs to the ophthalmic environment is well-recognised. The potential value of contact lenses as a means of ophthalmic drug delivery, and consequent improvement of pre-corneal retention is one obvious route to the development of a more effective ocular delivery system. Furthermore, the increasing availability and clinical use of daily disposable contact lenses provides the platform for the development of viable single-day use drug delivery devices based on existing materials and lenses. In order to provide a basis for the effective design of such devices, a systematic understanding of the factors affecting the interaction of individual drugs with the lens matrix is required. Because a large number of potential structural variables are involved, it is necessary to achieve some rationalisation of the parameters and physicochemical properties (such as molecular weight, charge, partition coefficients) that influence drug interactions. Ophthalmic dyes and structurally related compounds based on the same core structure were used to investigate these various factors and the way in which they can be used in concert to design effective release systems for structurally different drugs. Initial studies of passive diffusional release form a necessary precursor to the investigation of the features of the ocular environment that over-ride this simple behaviour. Commercially available contact lenses of differing structural classifications were used to study factors affecting the uptake of the surrogate actives and their release under 'passive' conditions. The interaction between active and lens material shows considerable and complex structure dependence, which is not simply related to equilibrium water content. The structure of the polymer matrix itself was found to have the dominant controlling influence on active uptake; hydrophobic interaction with the ophthalmic dye playing a major role. © The Author(s) 2014 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis describes the investigation of the effects of ocular supplements with different levels of nutrients on the macular pigment optical density (MPOD) in participants with healthy eyes. Abstract A review of the literature highlighted that ocular supplements are produced in various combinations of nutrients and concentrations. The ideal concentrations of nutrients such as lutein (L) have not been established. It was unclear whether different stages of eye disease require different concentrations of key nutrients, leading to the design of this study. The primary aim was to determine the effects of ocular supplements with different concentrations of nutrients on the MPOD of healthy participants. The secondary aim was to determine L and zeaxanthin (Z) intake at the start and end of the study through completion of food diaries. The primary study was split into two experiments. Experiment 1 was an exploratory study to determine sample size and experiment 2 the main study. Statistical power was calculated and a sample size of 38 was specified. Block stratification for age, gender and smoking habit was applied and from 101 volunteers 42 completed the study, 31 with both sets of food diaries. Four confounders were accounted for in the design of the study; gender, smoking habit, age and diet. Further factors that could affect comparability of results between studies were identified during the study and were not monitored; ethnicity, gastro-intestinal health, alcohol intake, body mass index and genetics. Comparisons were made between the sample population and the Sheffield general population according to recent demographic results in the public domain. Food diaries were analysed and shown to have no statistical difference when comparing baseline to final results. The average L and Z intake for the 31 participants who returned both sets of food diaries was initially 1.96mg and 1.51mg for the final food diaries. The effect of the two ocular supplements with different levels of xanthophyll (6mg lutein/zeaxanthin and 10mg lutein only) on MPOD was not significantly different over a four-month period.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/aims - To determine which biometric parameters provide optimum predictive power for ocular volume. Methods - Sixty-seven adult subjects were scanned with a Siemens 3-T MRI scanner. Mean spherical error (MSE) (D) was measured with a Shin-Nippon autorefractor and a Zeiss IOLMaster used to measure (mm) axial length (AL), anterior chamber depth (ACD) and corneal radius (CR). Total ocular volume (TOV) was calculated from T2-weighted MRIs (voxel size 1.0 mm3) using an automatic voxel counting and shading algorithm. Each MR slice was subsequently edited manually in the axial, sagittal and coronal plane, the latter enabling location of the posterior pole of the crystalline lens and partitioning of TOV into anterior (AV) and posterior volume (PV) regions. Results - Mean values (±SD) for MSE (D), AL (mm), ACD (mm) and CR (mm) were −2.62±3.83, 24.51±1.47, 3.55±0.34 and 7.75±0.28, respectively. Mean values (±SD) for TOV, AV and PV (mm3) were 8168.21±1141.86, 1099.40±139.24 and 7068.82±1134.05, respectively. TOV showed significant correlation with MSE, AL, PV (all p<0.001), CR (p=0.043) and ACD (p=0.024). Bar CR, the correlations were shown to be wholly attributable to variation in PV. Multiple linear regression indicated that the combination of AL and CR provided optimum R2 values of 79.4% for TOV. Conclusion - Clinically useful estimations of ocular volume can be obtained from measurement of AL and CR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study identifies and investigates the potential use of in-eye trigger mechanisms to supplement the widely available information on release of ophthalmic drugs from contact lenses under passive release conditions. Ophthalmic dyes and surrogates have been successfully employed to investigate how these factors can be drawn together to make a successful system. The storage of a drug-containing lens in a pH lower than that of the ocular environment can be used to establish an equilibrium that favours retention of the drug in the lens prior to ocular insertion. Although release under passive conditions does not result in complete dye elution, the use of mechanical agitation techniques which mimic the eyelid blink action in conjunction with ocular tear chemistry promotes further release. In this way differentiation between passive and triggered in vitro release characteristics can be established. Investigation of the role of individual tear proteins revealed significant differences in their ability to alter the equilibrium between matrix-held and eluate-held dye or drug. These individual experiments were then investigated in vivo using ophthalmic dyes. Complete elution was found to be achievable in-eye; this demonstrated the importance of that fraction of the drug retained under passive conditions and the triggering effect of in-eye conditions on the release process. Understanding both the structure-property relationship between drug and material and in-eye trigger mechanisms, using ophthalmic dyes as a surrogate, provides the basis of knowledge necessary to design ocular drug delivery vehicles for in-eye release in a controllable manner.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: In golf, the impact of eye-hand dominance on putting performance has long been debated. Eye-hand dominance is thought to impact how golfers judge the alignment of the ball with the target and the club with the ball, as well as how golfers visualize the line of the putt when making decisions about the force needed to hit the ball. Previous studies have all measured ocular dominance in primary gaze only, despite golfers spending a significant amount of their time in a putting stance (bent at the hips, head tilted down). Thus, the purpose of this study was to assess ocular dominance in both primary gaze (aligning the ball with the target) and putting gaze (addressing the ball and aligning the club). Methods: This study investigatedmeasuring pointing oculardominance in both primary and putting gaze positions on 31 golfers (14 amateur, 7 club professionals, and 10 top professionals). All playerswere right-handed golfers, although one reported having no hand dominance and one reported being strongly left hand dominant. Results: The results showed that (1) primary and putting gaze ocular dominances are not equal, nor are they predictive of each other; (2) themagnitude of putting ocular dominance is significantly less than themagnitude of primary gaze ocular dominance; (3) ocular dominance is not correlated with handedness in either primary or putting gaze; and (4) eye-hand dominance is not associated with increased putting skill, although ocular dominance may be associated with increased putting success. Conclusions: It is important that coaches assess golfers' ocular dominance in both primary and putting gaze positions to ensure they have the most accurate information upon which to base their vision strategy decisions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Ocular allergy is a broad group of allergic conditions involving inflammation of the conjunctiva and the most common forms are seasonal allergic conjunctivitis (SAC; 90% of cases) and perennial allergic conjunctivitis (PAC; 5% of cases). The main symptom is ocular itching caused by mast cell degranulation leading to the release of histamine and other mediators such as tryptase. Tryptase is a neutral protease that is selectively concentrated in the secretory granules of human mast cells and has been shown to be a sensitive and specific marker of type I hypersensitivity reaction. The objective was to ascertain the best assay method for determining the tryptase levels in tear samples and whether this can be used to determine the efficacy of non-pharmacological treatments compared to no treatment or their combined effect with anti-allergic medication for SAC and PAC. Method: Thirty patients with a history of SAC were recruited into a randomised blind study during winter months when all the patients were asymptomatic. Suitability was determined by skin prick and conjunctival provocation tests. Patients were randomly assigned to either a non-pharmacological or a pharmacological Intervention group and received each test condition assigned to their group in a randomly assigned order. Symptoms were provoked by exposure to pollen in an environmental test chamber where the temperature, humidity and grass pollen levels were set to a high pollen count day. Tear samples were taken set intervals during the visit and then processed by enzyme linked immunosorbent assay (ELISA) for the detection of tryptase levels. Preliminary results: Results are still being analysed but the preliminary optimisation experiments tested four different ELISA systems; two indirect assays and two capture ‹sandwich› assays. The results suggest that in both sandwich assay systems non-specific binding occurred which could not be easily overcome. The indirect assay systems both showed specific reactions, and the sensitivity achieved was greater with the monoclonal than the polyclonal antibody. Using these findings the indirect assay system was optimised to provide a standardised system for measuring tryptase. Initial trials using human tear samples displayed tryptase levels between 23.1 and 175.1 ng/ml; levels which fall within the anticipated range for patients with SAC. Further statistical work is needed to determine whether tryptase levels vary between the treatments 75.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present article describes a standard instrument for the continuous online determination of retinal vessel diameters, the commercially available retinal vessel analyzer. This report is intended to provide informed guidelines for measuring ocular blood flow with this system. The report describes the principles underlying the method and the instruments currently available, and discusses clinical protocol and the specific parameters measured by the system. Unresolved questions and the possible limitations of the technique are also discussed. © 2009 Acta Ophthalmol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Biotribology is essentially the study of friction, lubrication and wear in biological systems. The area has been widely studied in relation to the behaviour of synovial joints and the design and behaviour of hip joint prostheses, but only in the last decade have serious studies been extended to the eye. In the ocular environment - as distinct from articular joints - wear is not a major factor. Both lubrication and friction are extremely important, however; this is particularly the case in the presence of the contact lens, which is a medical device important not only in vision correction but also as a therapeutic bandage for the compromised cornea. This chapter describes the difficulty in replicating experimental conditions that accurately reflect the complex nature of the ocular environment together with the factors such as load and rate of travel of the eyelid, which is the principal moving surface in the eye. Results obtained across a range of laboratories are compared.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Changing demographics and in particular an increasingly ageing population, in combination with improved longevity, will have a major impact on changing the face of human diseases and likewise the demand for appropriate biomaterials. The ocular surface is a multifaceted system that combines to create a unique mucosal surface, which includes the cornea, conjunctiva, sclera and lids of the eye. Physical parameters such as the eyelids and eyelashes, combined with the numerous secretory glands that produce the complex tear film, act together to protect and maintain the cornea. Unfortunately an ageing tear film and lacrimal functional unit can lead to impairment of this magnificently orchestrated structure. No single mechanism or modification is responsible but, whatever the cause, the consequence is a reduction in tear stability. An uncompromised tear film is fundamental to a healthy ocular surface. In the face of progressively changing demographics and consequent requirements for medical intervention and medical device developments, it is important to understand what effects the ageing process has on these anterior ocular structures.