769 resultados para Occupational mobility.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is compelling evidence for the effectiveness of home-based occupational therapy and physiotherapy rehabilitation for community dwelling elderly who may struggle with basic activities and the functions of daily living and mobility. Nonetheless, an estimated 2% of home care’s elderly clients receive these therapies. Ontario’s home care data indicates that 78% of clients that could benefit from these specific therapies are not receiving them. The study examined a subset of elderly clients receiving home care following a hospital discharge during 2009-2010. The aim of this study was to: understand the difference between those home care clients who received occupational therapy or physiotherapy and those who did not; and determine if receiving these therapies impacted the utilization of hospital emergency departments and inpatient admissions. A retrospective cohort design and multivariate and survival analysis of hospital and home care administrative data structured the study. Results suggest that home-based rehabilitation is offered to a minority of the home care population. Distinct client characteristics and process variables significantly associated with the increased likelihood of receiving home-based occupational and physical therapies included: clients who were older, females, admitted to home care from hospital inpatient units, assessed as non-acute for clinical and service needs and required more home making support and assistance with activities of daily living. Almost one quarter of the total sample returned to hospital. Visits to emergency departments accounted for the greater part of hospital utilization and primarily for sub-acute general symptoms and signs, post-procedural complications, infections or acute episodes from chronic obstructive pulmonary disease and renal failure. Slightly over half of the clients returning to hospital did not receive home-based rehabilitation. Clients who received occupational therapy returned to the hospital sooner following their home care admission whereas clients receiving physiotherapy spent the longest time before rehospitalizing. The majority of the clients receiving occupational therapy were admitted to home care having just resolved sub-acute conditions or symptoms, many of which are known to influence functional and physical decline. Moreover, analysis of process variables indicated that the wait time for a referral to occupational therapy was two times longer compared to physiotherapy. These same clients also waited, on average, over one month before an occupational therapist’s first visit. The need to discriminate who receives home-based rehabilitation is essential to understanding how specific therapies contribute to improving systems outcomes. This study is the first examination that focuses specifically on home-based occupational therapy and physiotherapy rehabilitation and the client characteristics and process variables associated with receiving/not receiving these therapies and the impact these factors have on the time-to-rehospitalization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The distribution coefficient, K-d, is often used to quantify heavy metal mobility in soils. Batch sorption or column infiltration tests may be used to measure K-d. The latter are closer to natural soil conditions, but are difficult to conduct in clays. This difficulty can be overcome by using a laboratory centrifuge. An acceleration of 2600 gravities was applied to columns of London Clay, an Eocene clay sub-stratum, and Cu, Ni, and Zn mobility was measured in centrifuge infiltration tests, both as single elements and in dual competition. Single-element K-d values were also obtained from batch sorption tests, and the results from the two techniques were compared. It was found that K-d values obtained by batch tests vary considerably depending on the metal concentration, while infiltration tests provided a single K-d value for each metal. This was typically in the lower end of the range of the batch test K-d values. For both tests, the order of mobility was Ni > Zn > Cu. Metals became more mobile in competition than when in single-element systems: Ni K-d decreased 3.3 times and Zn K-d 3.4 times when they competed with Cu, while Cu decreased only 1.2 times when in competition with either Ni or Zn. Our study showed that competitive sorption between metals increases the mobility of those metals less strongly bound more than it increases the mobility of more strongly bound metals.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A voluminous literature exists on the analysis of water-soluble ions extracted from gypsum crusts and patinas formed on building surfaces. However, less data is available on the intermediate dust layer and the important role its complex matrix and constituents play in crust/patina formation. To address this issue, surface dust samples were collected from two buildings in the city of Budapest. Substrate properties, different pollution levels and environmental variations were considered by collecting samples from a city centre granite building exposed to intense traffic conditions and from an oolitic limestone church situated in a pedestrian area outside and high above the main pollution zone. Selective extraction examines both water-soluble ions (Ca2+, Mg2+, Na+, K+, Cl-, NO3- SO42-) and selected elements (Fe, Mn, Zn, Cu, Cr, Pb, Ni) from the water-soluble, exchangeable/carbonate, amorphous Mn, amorphous Fe/Mn, crystalline Fe/Mn, organic and residual phases, their mobility and potential to catalyse heterogeneous surface reactions. Salt weathering processes are highlighted by high concentrations of water-soluble Ca2+, Na+, Cl- and SO42-- at both sites. Manganese, Zn and Cu and to a lesser extent Pb and Ni, are very mobile in the city centre dust, where 30%, 54%, 38%, 11% and 11% of their totals are bound by the water-soluble phase, respectively. Church dust shows a sharp contrast for Mn, Zn, Cu and Pb with only 3%, 1%, 12% and 3% of their totals being bound by the water-soluble phase respectively. This may be due to (a) different environmental conditions at the church e.g. lower humidity (b) continuous replenishment of salts under intensive city centre traffic conditions (c) enrichment in oxidisable organic carbon by a factor of 4.5 and a tenfold increase in acidity in the city centre dust.