943 resultados para Obesity. Cardiopulmonary exercise test. uptake oxygen. incremental test


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Robotics-assisted tilt table (RATT) technology provides body support, cyclical stepping movement and physiological loading. This technology can potentially be used to facilitate the estimation of peak cardiopulmonary performance parameters in patients who have neurological or other problems that may preclude testing on a treadmill or cycle ergometer. The aim of the study was to compare the magnitude of peak cardiopulmonary performance parameters including peak oxygen uptake (VO2peak) and peak heart rate (HRpeak) obtained from a robotics-assisted tilt table (RATT), a cycle ergometer and a treadmill. The strength of correlations between the three devices, test-retest reliability and repeatability were also assessed. Eighteen healthy subjects performed six maximal exercise tests, with two tests on each of the three exercise modalities. Data from the second tests were used for the comparative and correlation analyses. For nine subjects, test-retest reliability and repeatability of VO2peak and HRpeak were assessed. Absolute VO2peak from the RATT, the cycle ergometer and the treadmill was (mean (SD)) 2.2 (0.56), 2.8 (0.80) and 3.2 (0.87) L/min, respectively (p < 0.001). HRpeak from the RATT, the cycle ergometer and the treadmill was 168 (9.5), 179 (7.9) and 184 (6.9) beats/min, respectively (p < 0.001). VO2peak and HRpeak from the RATT vs the cycle ergometer and the RATT vs the treadmill showed strong correlations. Test-retest reliability and repeatability were high for VO2peak and HRpeak for all devices. The results demonstrate that the RATT is a valid and reliable device for exercise testing. There is potential for the RATT to be used in severely impaired subjects who cannot use the standard modalities.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We determined the stable oxygen and carbon isotopic composition of live (Rose Bengal stained) tests belonging to different size classes of two benthic foraminiferal species from the Pakistan continental margin. Samples were taken at 2 sites, with water depth of about 135 and 275 m, corresponding to the upper boundary and upper part of the core region of the oxygen minimum zone (OMZ). For Uvigerina ex gr. U. semiornata and Bolivina aff. B. dilatata, delta13C and delta18O values increased significantly with increasing test size. In the case of U. ex gr. U. semiornata, delta13C increased linearly by about 0.105 per mil for each 100-µm increment in test size, whereas delta18O increased by 0.02 to 0.06 per mil per 100 µm increment. For B. aff. B. dilatata the relationship between test size and stable isotopic composition is better described by logarithmic equations. A strong positive linear correlation is observed between delta18O and delta13C values of both taxa, with a constant ratio of delta18O and delta13C values close to 2:1. This suggests that the strong ontogenetic effect is mainly caused by kinetic isotope fractionation during CO2 uptake. Our data underline the necessity to base longer delta18O and delta13C isotope records derived from benthic foraminifera on size windows of 100 µm or less. This is already common practice in down-core isotopic studies of planktonic foraminifera.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study sought to analyse the behaviour of the average spinal posture using a novel investigative procedure in a maximal incremental effort test performed on a treadmill. Spine motion was collected via stereo-photogrammetric analysis in thirteen amateur athletes. At each time percentage of the gait cycle, the reconstructed spine points were projected onto the sagittal and frontal planes of the trunk. On each plane, a polynomial was fitted to the data, and the two-dimensional geometric curvature along the longitudinal axis of the trunk was calculated to quantify the geometric shape of the spine. The average posture presented at the gait cycle defined the spine Neutral Curve. This method enabled the lateral deviations, lordosis, and kyphosis of the spine to be quantified noninvasively and in detail. The similarity between each two volunteers was a maximum of 19% on the sagittal plane and 13% on the frontal (p<0.01). The data collected in this study can be considered preliminary evidence that there are subject-specific characteristics in spinal curvatures during running. Changes induced by increases in speed were not sufficient for the Neutral Curve to lose its individual characteristics, instead behaving like a postural signature. The data showed the descriptive capability of a new method to analyse spinal postures during locomotion; however, additional studies, and with larger sample sizes, are necessary for extracting more general information from this novel methodology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to test the hypothesis that in obese children: 1) Ventilatory efficiency (VentE) is decreased during graded exercise; and 2) Weight loss through diet alone (D) improves VentE, and 3) diet associated with exercise training (DET) leads to greater improvement in VentE than by D. Thirty-eight obese children (10 +/- 0.2 years; BMI > 95(th) percentile) were randomly divided into two Study groups: D (n=17; BMI = 30 +/- 1 kg/m(2)) and DET (n = 21; 28 +/- 1 kg/m(2)). Ten lean children were included in a control group (10 +/- 0.3 years; 17 +/- 0.5 kg/m(2)). All children performed maximal treadmill testing with respiratory gas analysis (breath-by-breath) to determine the ventilatory anaerobic threshold (VAT) and peak oxygen consumption (VO(2) peak). VentE was determined by the VE/VCO(2) method at VAT. Obese children showed lower VO(2) peak and lower VentE than controls (p < 0.05). After interventions, all obese children reduced body weight (p < 0.05). D group did not improve in terms of VO(2) peak or VentE (p > 0.05). In contrast, the DET group showed increased VO(2) peak (p = 0.01) and improved VentE(Delta VE/VCO(2) = -6.1 +/- 0.9; p = 0.01). VentE is decreased in obese children, where weight loss by means of DET, but not D alone, improves VentE and cardiorespiratory fitness during graded exercise.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study compared measurements of upper body aerobic fitness in elite (EC; n = 7) and intermediate rock climbers (IC; n = 7), and a control group (C; n = 7). Subjects underwent an upper limb incremental test on hand cycle ergometer, with increments of 23 W.min(-1), until exhaustion. Ventilation (VE) data were smoothed to 10 s averages and plotted against time for the visual determination of the first (VT1) and second (VT2) ventilatory thresholds. Peak power output was not different among groups [EC = 130.9 (+/- 11.8) W; IC = 122.1 (+/- 28.4) W; C = 115.4 (+/- 15.1) W], but time to exhaustion was significantly higher in EC than IC and C. VO(2PEAK) was significantly higher in EC [36.8 (+/- 5.7) mL.kg(-1).min(-1)] and IC [35.5 (+/- 5.2) mL.kg(-1).min(-1)] than C [28.8 (+/- 5.0) mL.kg(-1).min(-1)], but there was no difference between EC and IC. VT1 was significantly higher in EC than C [EC = 69.0 (+/- 9.4) W; IC = 62.4 (+/- 13.0) W; C = 52.1 (+/- 11.8) W], but no significant difference was observed in VT2 [EC = 103.5 (+/- 18.8) W; IC = 92.0 (+/- 22.0) W; C = 85.6 (+/- 19.7) W]. These results show that elite indoor rock climbers elicit higher aerobic fitness profile than control subjects when measured with an upper body test.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We analyzed the usefulness of a semi-tethered field running test (STR) and the relationships between indices of anaerobic power, anaerobic capacity and running performance in 9 trained male sprinters (22.2 +/- 2.9 yrs, 176 +/- 1 cm, 68.0 +/- 9.4 kg). STR involved an all out 120 m run attached to an apparatus that enabled power calculation from force and velocity measures. Subjects also carried out a cycloergometer Win-gate Anaerobic Test (WT), an all out 300 m run and had accessed their maximal accumulated oxygen deficit (MAOD) on a treadmill. Peak and mean powers attained in STR (1 720 +/- 221 and 1 391 +/- 201 W) were greater but significantly related (r=0.82; P<0.01) to those in the WT (808 +/- 130 and 603 +/- 87 W). In addition, power measures derived from the STR were stronger related to running performance compared to those from the WT (r=0.81-0.94 vs. 0.68-0.84; P<0.05). Relationships between MAOD and most power indices were only weak to moderate. These results support the usefulness of STR for specific power assessment in field running and suggest that anaerobic power and capacity are not related entities, irrespective of having been evaluated using similar or dissimilar exercise modes.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Correct modeling of root water uptake partitioning over depth is an important issue in hydrological and crop growth models. Recently a physically based model to describe root water uptake was developed at single root scale and upscaled to the root system scale considering a homogeneous distribution of roots per soil layer. Root water uptake partitioning is calculated over soil layers or compartments as a function of respective soil hydraulic conditions, specifically the soil matric flux potential, root characteristics and a root system efficiency factor to compensate for within-layer root system heterogeneities. The performance of this model was tested in an experiment performed in two-compartment split-pot lysimeters with sorghum plants. The compartments were submitted to different irrigation cycles resulting in contrasting water contents over time. The root system efficiency factor was determined to be about 0.05. Release of water from roots to soil was predicted and observed on several occasions during the experiment; however, model predictions suggested root water release to occur more often and at a higher rate than observed. This may be due to not considering internal root system resistances, thus overestimating the ease with which roots can act as conductors of water. Excluding these erroneous predictions from the dataset, statistical indices show model performance to be of good quality.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The purpose of this study was to evaluate the effect of long-term use of oral contraceptives (DC) containing 0.20 mg of ethinylestradiol (EE) combined with 0.15 mg of gestodene (GEST) on the peak aerobic capacity and at the anaerobic threshold (AT) level in active and sedentary young women. Study Design: Eighty-eight women (23 +/- 2.1 years old) were divided into four groups active-OC (G1), active-NOC (G2), sedentary-OC (G3) and sedentary-NOC (G4) and were submitted to a continuous ergospirometric incremental test on a cycloergometer with 20 to 25 W min(-1) increments. Data were analyzed by two-way ANOVA with Tukey post hoc test. Level of significance was set at 5%. Results: The OC use effect for the variables relative and absolute oxygen uptake VO(2) mL kg(-1) min(-1); VO(2), L min(-1), respectively), carbon dioxide output (VCO(2), L min(-1)), ventilation (VE, L min(-1)), heart rate (HR, bpm), respiratory exchange ratio (RER) and power output (W) data, as well as the interaction between OC use and exercise effect on the peak of test and at the AT level did not differ significantly between the active groups (G1 and G2) and the sedentary groups (G3 and G4). As to the exercise effect, for all variables studied, it was noted that the active groups presented higher values for the variables VO(2), VCO(2), VE and power output (p<.05) than the sedentary groups. The RER and HR were similar (p>.05) at the peak and at the AT level between G1 vs. G3 and G2 vs. G4. Conclusions: Long-term use of OC containing EE 0.20 mg plus GEST 0.15 mg does not affect aerobic capacity at the peak and at the AT level of exercise tests. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to compare accumulated oxygen deficit data derived using two different exercise protocols with the aim of producing a less time-consuming test specifically for use with athletes. Six road and four track male endurance cyclists performed two series of cycle ergometer tests. The first series involved five 10 min sub-maximal cycle exercise bouts, a (V) over dotO(2peak) test and a 115% (V) over dotO(2peak) test. Data from these tests were used to estimate the accumulated oxygen deficit according to the calculations of Medbo et al. (1988). In the second series of tests, participants performed a 15 min incremental cycle ergometer test followed, 2 min later, by a 2 min variable resistance test in which they completed as much work as possible while pedalling at a constant rate. Analysis revealed that the accumulated oxygen deficit calculated from the first series of tests was higher (P< 0.02) than that calculated from the second series: 52.3 +/- 11.7 and 43.9 +/- 6.4 ml . kg(-1), respectively (mean +/- s). Other significant differences between the two protocols were observed for (V) over dot O-2peak, total work and maximal heart rate; all were higher during the modified protocol (P

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper concerns the study of biocides application in old timber structures of maritime pine (Pinus pinaster Ail.), previously impregnated with other products. A method was developed in laboratory to determine in situ the penetration depth of a product applied superficially. As initial treatment, three traditional products for sawn timber for buildings were used and, for new treatments, two newer, more environmentally benign products were used. Their ability to penetrate the pre-treated surfaces was evaluated after 1, 2 and 3 applications at 24 hours intervals and the results obtained are presented. Finally, the applicability of the developed test to the in-situ evaluation of timber structures is also discussed.

Relevância:

60.00% 60.00%

Publicador:

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The contribution of respiratory muscle work to the development of the O(2) consumption (Vo(2)) slow component is a point of controversy because it has been shown that the increased ventilation in hypoxia is not associated with a concomitant increase in Vo(2) slow component. The first purpose of this study was thus to test the hypothesis of a direct relationship between respiratory muscle work and Vo(2) slow component by manipulating inspiratory resistance. Because the conditions for a Vo(2) slow component specific to respiratory muscle can be reached during intense exercise, the second purpose was to determine whether respiratory muscles behave like limb muscles during heavy exercise. Ten trained subjects performed two 8-min constant-load heavy cycling exercises with and without a threshold valve in random order. Vo(2) was measured breath by breath by using a fast gas exchange analyzer, and the Vo(2) response was modeled after removal of the cardiodynamic phase by using two monoexponential functions. As anticipated, when total work was slightly increased with loaded inspiratory resistance, slight increases in base Vo(2), the primary phase amplitude, and peak Vo(2) were noted (14.2%, P < 0.01; 3.5%, P > 0.05; and 8.3%, P < 0.01, respectively). The bootstrap method revealed small coefficients of variation for the model parameter, including the slow-component amplitude and delay (15 and 19%, respectively), indicating an accurate determination for this critical parameter. The amplitude of the Vo(2) slow component displayed a 27% increase from 8.1 +/- 3.6 to 10.3 +/- 3.4 ml. min(-1). kg(-1) (P < 0.01) with the addition of inspiratory resistance. Taken together, this increase and the lack of any differences in minute volume and ventilatory parameters between the two experimental conditions suggest the occurrence of a Vo(2) slow component specific to the respiratory muscles in loaded condition.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this study was to test the hypothesis that athletes having a slower oxygen uptake ( VO(2)) kinetics would benefit more, in terms of time spent near VO(2max), from an increase in the intensity of an intermittent running training (IT). After determination of VO(2max), vVO(2max) (i.e. the minimal velocity associated with VO(2max) in an incremental test) and the time to exhaustion sustained at vVO(2max) ( T(lim)), seven well-trained triathletes performed in random order two IT sessions. The two IT comprised 30-s work intervals at either 100% (IT(100%)) or 105% (IT(105%)) of vVO(2max) with 30-s recovery intervals at 50% of vVO(2max) between each repeat. The parameters of the VO(2) kinetics (td(1), tau(1), A(1), td(2), tau(2), A(2), i.e. time delay, time constant and amplitude of the primary phase and slow component, respectively) during the T(lim) test were modelled with two exponential functions. The highest VO(2) reached was significantly lower ( P<0.01) in IT(100%) run at 19.8 (0.9) km(.)h(-1) [66.2 (4.6) ml(.)min(-1.)kg(-1)] than in IT(105%) run at 20.8 (1.0) km(.)h(-1) [71.1 (4.9) ml(.)min(-1.)kg(-1)] or in the incremental test [71.2 (4.2) ml(.)min(-1.)kg(-1)]. The time sustained above 90% of VO(2max) in IT(105%) [338 (149) s] was significantly higher ( P<0.05) than in IT(100%) [168 (131) s]. The average T(lim) was 244 (39) s, tau(1) was 15.8 (5.9) s and td(2) was 96 (13) s. tau(1) was correlated with the difference in time spent above 90% of VO(2max) ( r=0.91; P<0.01) between IT(105%) and IT(100%). In conclusion, athletes with a slower VO(2) kinetics in a vVO(2max) constant-velocity test benefited more from the 5% rise of IT work intensity, exercising for longer above 90% of VO(2max) when the IT intensity was increased from 100 to 105% of vVO(2max).