946 resultados para NEWTONIAN FLUID
Resumo:
The objective of the work is to study fluid flow behavior through a pinch valve and to estimate the flow coefficient (KV ) at different opening positions of the valve. The flow inside a compressed valve is more complex than in a straight pipe, and it is one of main topics of interest for engineers in process industry. In the present work, we have numerically simulated compressed valve flow at different opening positions. In order to simulate the flow through pinch valve, several models of the elastomeric valve tube (pinch valve tube) at different opening positions were constructed in 2D-axisymmetric and 3D geometries. The numerical simulations were performed with the CFD packages; ANSYS FLUENT and ANSYS CFX by using parallel computing. The distributions of static pressure, velocity and turbulent kinetic energy have been studied at different opening positions of the valve in both 2D-axisymmetric and 3D experiments. The flow coefficient (KV ) values have been measured at different valve openings and are compared between 2D-axisymmetric and 3D simulation results.
Resumo:
The objective of this dissertation is to improve the dynamic simulation of fluid power circuits. A fluid power circuit is a typical way to implement power transmission in mobile working machines, e.g. cranes, excavators etc. Dynamic simulation is an essential tool in developing controllability and energy-efficient solutions for mobile machines. Efficient dynamic simulation is the basic requirement for the real-time simulation. In the real-time simulation of fluid power circuits there exist numerical problems due to the software and methods used for modelling and integration. A simulation model of a fluid power circuit is typically created using differential and algebraic equations. Efficient numerical methods are required since differential equations must be solved in real time. Unfortunately, simulation software packages offer only a limited selection of numerical solvers. Numerical problems cause noise to the results, which in many cases leads the simulation run to fail. Mathematically the fluid power circuit models are stiff systems of ordinary differential equations. Numerical solution of the stiff systems can be improved by two alternative approaches. The first is to develop numerical solvers suitable for solving stiff systems. The second is to decrease the model stiffness itself by introducing models and algorithms that either decrease the highest eigenvalues or neglect them by introducing steady-state solutions of the stiff parts of the models. The thesis proposes novel methods using the latter approach. The study aims to develop practical methods usable in dynamic simulation of fluid power circuits using explicit fixed-step integration algorithms. In this thesis, twomechanisms whichmake the systemstiff are studied. These are the pressure drop approaching zero in the turbulent orifice model and the volume approaching zero in the equation of pressure build-up. These are the critical areas to which alternative methods for modelling and numerical simulation are proposed. Generally, in hydraulic power transmission systems the orifice flow is clearly in the turbulent area. The flow becomes laminar as the pressure drop over the orifice approaches zero only in rare situations. These are e.g. when a valve is closed, or an actuator is driven against an end stopper, or external force makes actuator to switch its direction during operation. This means that in terms of accuracy, the description of laminar flow is not necessary. But, unfortunately, when a purely turbulent description of the orifice is used, numerical problems occur when the pressure drop comes close to zero since the first derivative of flow with respect to the pressure drop approaches infinity when the pressure drop approaches zero. Furthermore, the second derivative becomes discontinuous, which causes numerical noise and an infinitely small integration step when a variable step integrator is used. A numerically efficient model for the orifice flow is proposed using a cubic spline function to describe the flow in the laminar and transition areas. Parameters for the cubic spline function are selected such that its first derivative is equal to the first derivative of the pure turbulent orifice flow model in the boundary condition. In the dynamic simulation of fluid power circuits, a tradeoff exists between accuracy and calculation speed. This investigation is made for the two-regime flow orifice model. Especially inside of many types of valves, as well as between them, there exist very small volumes. The integration of pressures in small fluid volumes causes numerical problems in fluid power circuit simulation. Particularly in realtime simulation, these numerical problems are a great weakness. The system stiffness approaches infinity as the fluid volume approaches zero. If fixed step explicit algorithms for solving ordinary differential equations (ODE) are used, the system stability would easily be lost when integrating pressures in small volumes. To solve the problem caused by small fluid volumes, a pseudo-dynamic solver is proposed. Instead of integration of the pressure in a small volume, the pressure is solved as a steady-state pressure created in a separate cascade loop by numerical integration. The hydraulic capacitance V/Be of the parts of the circuit whose pressures are solved by the pseudo-dynamic method should be orders of magnitude smaller than that of those partswhose pressures are integrated. The key advantage of this novel method is that the numerical problems caused by the small volumes are completely avoided. Also, the method is freely applicable regardless of the integration routine applied. The superiority of both above-mentioned methods is that they are suited for use together with the semi-empirical modelling method which necessarily does not require any geometrical data of the valves and actuators to be modelled. In this modelling method, most of the needed component information can be taken from the manufacturer’s nominal graphs. This thesis introduces the methods and shows several numerical examples to demonstrate how the proposed methods improve the dynamic simulation of various hydraulic circuits.
Resumo:
For decades researchers have been trying to build models that would help understand price performance in financial markets and, therefore, to be able to forecast future prices. However, any econometric approaches have notoriously failed in predicting extreme events in markets. At the end of 20th century, market specialists started to admit that the reasons for economy meltdowns may originate as much in rational actions of traders as in human psychology. The latter forces have been described as trading biases, also known as animal spirits. This study aims at expressing in mathematical form some of the basic trading biases as well as the idea of market momentum and, therefore, reconstructing the dynamics of prices in financial markets. It is proposed through a novel family of models originating in population and fluid dynamics, applied to an electricity spot price time series. The main goal of this work is to investigate via numerical solutions how well theequations succeed in reproducing the real market time series properties, especially those that seemingly contradict standard assumptions of neoclassical economic theory, in particular the Efficient Market Hypothesis. The results show that the proposed model is able to generate price realizations that closely reproduce the behaviour and statistics of the original electricity spot price. That is achieved in all price levels, from small and medium-range variations to price spikes. The latter were generated from price dynamics and market momentum, without superimposing jump processes in the model. In the light of the presented results, it seems that the latest assumptions about human psychology and market momentum ruling market dynamics may be true. Therefore, other commodity markets should be analyzed with this model as well.
Resumo:
PURPOSE: To verify the predictors of intravasation rate during hysteroscopy.METHODS: Prospective observational study (Canadian Task Force classification II-1). All cases (n=200 women; 22 to 86 years old) were treated in an operating room setting. Considering respective bag overfill to calculate water balance, we tested two multiple linear regression models: one for total intravasation (mL) and the other for absorption rate (mL.min-1). The predictors tested (independent variables) were energy (mono/bipolar), tube patency (with/without tubal ligation), hysterometry (cm), age≤50 years, body surface area (m2), surgical complexity (with/without myomectomy) and duration (min).RESULTS: Mean intravasation was significantly higher when myomectomy was performed (442±616 versus 223±332 mL; p<0.01). In the proposed multiple linear regression models for total intravasation (adjusted R2=0.44; p<0.01), the only significant predictors were myomectomy and duration (p<0.01).In the proposed model for intravasation rate (R2=0.39; p<0.01), only myomectomy and hysterometry were significant predictors (p=0.02 and p<0.01, respectively).CONCLUSIONS: Not only myomectomy but also hysterometry were significant predictors of intravasation rate during operative hysteroscopy.
Resumo:
Intestinal devitalization in cases of small colon obstruction may be difficult to detect based only in clinical signs. The purpose was to serially evaluate blood and peritoneal fluid of horses subjected to small colon distension. Seventeen adult horses were allotted in three groups. In the small colon-distended group (DG, n=7) a surgically-implanted latex balloon was inflated to promote intraluminal small colon distension. In the shamoperated group (SG, n=5), the balloon was implanted but not inflated, and no surgery was done in the control group (CG, n=5). Blood and peritoneal fluid were sampled before and after (6 samples with a 30-minute interval) intestinal obstruction for cytological and biochemical analyses. No significant changes in clinical signs occurred within groups or across time during the experimental period. There were no statistical differences among SG and SG groups in hematologic and blood chemistry variables. Although total protein concentration and lactate dehydrogenase (LDH) activity in peritoneal fluid remained most of the time within reference values during the experimental period in all groups, increases from baseline values were detected in SG and DG groups. Such increases occurred earlier, progressively and with greater magnitude in the DG when compared with the SG (P<0.05). Increases from baselines values were also observed in total nucleated cells and neutrophils counts in the DG (P<0.05). In conclusion, distension of the equine small colon induced progressive subtle increases in total protein and LDH concentrations in the peritoneal fluid during the first hours. Serial evaluation of these variables in peritoneal fluid may be useful for early detection of intestinal devitalization in clinical cases of equine small colon obstruction.
Resumo:
This paper reports the effects of fluid therapy in goats through nasogastric route with an electrolyte solution composed by concentrations of sodium, potassium and chloride similar to goat plasma (140mmol/L of Na+, 4.5mmol/L of K+, 110mmol/L of Cl-). Four Alpine Chamoisee goats, two of them with evident leakage of the rumen cannulas, were used in a crossover experimental design of two periods and two groups. In one group the two goats were submitted to a treatment protocol to induce dehydration before the fluid therapy, whereas the other group was not. Fluid therapy consisted supplying 10mL/kg/h of the electrolyte solution during 8 hours. No signs of discomfort or stress were observed. The dehydration model employed caused a mild dehydration indicated by decrease in feces humidity, body weight and abdominal circumference, and increase in plasma total solids concentration. During fluid therapy globular volume and plasma total solids decreased, whereas % body weight and abdominal circumference increased. No signs of hyperhydration were observed and serum electrolytes (Na+, Cl-, K+) presented no significant alterations in both groups. Fluid therapy proposed in this study was efficient to treat dehydration, even for rumen cannulated animals with evident leakage, and can be administrated safely with no electrolyte imbalance.
Resumo:
The study aimed to quantify the concentrations of free IGF-I in serum and fluid of ovarian follicles in pre-pubertal gilts and describe the ovarian morphology by measuring the size of the ovaries and counting the number of surface follicles. Ovaries (n=1,000) from pre-pubertal gilts were obtained immediately after slaughter. A total of 10 samplings were performed, with ovaries obtained from 50 females for each collection. The follicles situated on the surface of each ovary were classified as small (SFs, 2 to 5mm in diameter) or large (LFs 6 to 10mm in diameter) and the follicular fluid was obtained by follicle aspiration. The collection of serum samples was performed after the gilts exsanguination using sterile tubes. From the pool of serum and follicular fluid obtained from 50 females, the concentration of free IGF-I was determined in each sample using an enzyme immunoassay kit (ELISA). The description of ovarian morphometry was performed in 100 ovaries from randomly selected gilts. The larger and smaller lengths of ovaries were measured, and the total number of SFs and LFs present on the surface of each ovary were also counted. The IGF-I concentration was greater (P<0.05) in LFs (170.92±88.29 ng/mL) compared with SFs (67.39±49.90ng/mL) and serum (73.48±34.63ng/mL). The largest and smallest length of the ovaries was 26.0±3.0 and 19.0mm ±2.0mm, respectively. The number of SFs (70.86±25.76) was greater (P<0.01) than LFs (6.54±5.26). The study concluded that LFs present greater levels of IGF-I when compared with SFs and blood, which is related to increased activity of the LFs and its differentiation to ovulation. In addition, ovaries of pre-pubertal gilts have a higher number of SFs compared to LFs. Therefore, our study demonstrated unique data regarding the physiological concentration of free IGF-I in ovarian follicles, that can be used in future research to evaluate the addition of this hormone in the in vitro production media of porcine embryos with the goal to improve the technique efficiency.
Resumo:
The study aimed to compare the effects of intraosseous infusion of lactated Ringer's and 0.9% sodium chloride solutions on the electrolytes and acid-base balance in pigeons submitted to humerus osteosynthesis. Eighteen pigeons were undergoing to isoflurane anesthesia by an avalvular circuit system. They were randomly assigned into two groups (n=9) receiving lactated Ringer's solution (LR) or 0.9% sodium chloride (SC), in a continuous infusion rate of 20mL/kg/h, by using an intraosseous catheter into the tibiotarsus during 60-minute anesthetic procedure. Heart rate (HR), and respiratory rate (RR) were measured every 10 min. Venous blood samples were collected at 0, 30 and 60 minutes to analyze blood pH, PvCO2, HCO3 -, Na+ and K+. Blood gases and electrolytes showed respiratory acidosis in both groups during induction, under physical restraint. This acidosis was evidenced by a decrease of pH since 0 min, associated with a compensatory response, observed by increasing of HCO3 - concentration, at 30 and 60 min. It was not observed any changes on Na+ and K+ serum concentrations. According to the results, there is no reason for choosing one of the two solutions, and it could be concluded that both fluid therapy solutions do not promote any impact on acid-base balance and electrolyte concentrations in pigeons submitted to humerus osteosynthesis.
Resumo:
In many engineering applications, compliant piping systems conveying liquids are subjected to inelastic deformations due to severe pressure surges such as plastic tubes in modern water supply transmission lines and metallic pipings in nuclear power plants. In these cases the design of such systems may require an adequate modeling of the interactions between the fluid dynamics and the inelastic structural pipe motions. The reliability of the prediction of fluid-pipe behavior depends mainly on the adequacy of the constitutive equations employed in the analysis. In this paper it is proposed a systematic and general approach to consistently incorporate different kinds of inelastic behaviors of the pipe material in a fluid-structure interaction analysis. The main feature of the constitutive equations considered in this work is that a very simple numerical technique can be used for solving the coupled equations describing the dynamics of the fluid and pipe wall. Numerical examples concerning the analysis of polyethylene and stainless steel pipe networks are presented to illustrate the versatility of the proposed approach.
Resumo:
Hydraulic head is distributed through a medium with porous aspect. The analysis of hydraulic head from one point to another is used by the Richard's equation. This equation is equivalent to the groundwater ow equation that predicts the volumetric water contents. COMSOL 3.5 is used for computation applying Richard's equation. A rectangle of 100 meters of length and 10 meters of large (depth) with 0,1 m/s fl ux of inlet as source of our fl uid is simulated. The domain have Richards' equation model in two dimension (2D). Hydraulic head increases proportional with moisture content.
Resumo:
Cirrhotic patients (23 with alcoholic cirrhosis, 5 with posthepatitic cirrhosis and 2 with cryptogenic cirrhosis) with ascites and portal hypertension were studied and divided into two groups corresponding to high or low risk to develop spontaneous bacterial peritonitis (SBP) related to the concentration of total protein in the ascitic fluid (A-TP): group I (high risk): A-TP£1.5 g/dl and group II (low risk): A-TP>1.5 g/dl. Fibronectin (FN), C3 and C4 concentrations were measured by radial immunodiffusion while total protein was measured by the biuret method. The mean values (group I vs group II) of C3 (12.59 ± 4.72 vs 24.53 ± 15.58 mg/dl), C4 (4.26 ± 3.87 vs 7.26 ± 4.14 mg/dl) and FN (50.47 ± 12.49 vs 75.89 ± 24.70 mg/dl) in the ascitic fluid were significantly lower (P<0.05) in the group considered to be at high risk for SBP. No significant difference was observed in the plasma/ascites fibronectin ratio (3.91 ± 1.21 vs 3.80 ± 1.26) or gradient (131.46 ± 64.01 vs 196.96 ± 57.38) between groups. Fibronectin in ascites was significantly correlated to C3 (r = 0.76), C4 (r = 0.58), total protein (r = 0.73) and plasma FN (r = 0.58) (P<0.05). The data suggest that the FN concentration in ascites is related to the opsonic capacity of this fluid, and that its concentration in the ascitic fluid may be a biochemical risk factor indicator for the development of spontaneous bacterial peritonitis
Resumo:
We determined the effect of acute extracellular fluid volume changes on saline flow through 4 gut segments (ileocolonic, ileal, ileocolonic sphincter and proximal colon), perfused at constant pressure in anesthetized dogs. Two different experimental protocols were used: hypervolemia (iv saline infusion, 0.9% NaCl, 20 ml/min, volume up to 5% body weight) and controlled hemorrhage (up to a 50% drop in mean arterial pressure). Mean ileocolonic flow (N = 6) was gradually and significantly decreased during the expansion (17.1%, P<0.05) and expanded (44.9%, P<0.05) periods while mean ileal flow (N = 7) was significantly decreased only during the expanded period (38%, P<0.05). Mean colonic flow (N = 7) was decreased during expansion (12%, P<0.05) but returned to control levels during the expanded period. Mean ileocolonic sphincter flow (N = 6) was not significantly modified. Mean ileocolonic flow (N = 10) was also decreased after hemorrhage (retracted period) by 17% (P<0.05), but saline flow was not modified in the other separate circuits (N = 6, 5 and 4 for ileal, ileocolonic sphincter and colonic groups, respectively). The expansion effect was blocked by atropine (0.5 mg/kg, iv) both on the ileocolonic (N = 6) and ileal (N = 5) circuits. Acute extracellular fluid volume retraction and expansion increased the lower gastrointestinal resistances to saline flow. These effects, which could physiologically decrease the liquid volume being supplied to the colon, are possible mechanisms activated to acutely balance liquid volume deficit and excess.
Resumo:
The antimicrobial, hemagglutinating and toxic activities of the purple fluid of the sea hare Aplysia dactylomela are described. Intact or dialyzed purple fluid inhibited the growth of species of Gram-positive and Gram-negative bacteria and the action was not bactericidal but bacteriostatic. The active factor or factors were heat labile and sensitive to extreme pH values. The fluid preferentially agglutinated rabbit erythrocytes and, to a lesser extent, human blood cells, and this activity was inhibited by the glycoprotein fetuin, a fact suggesting the presence of a lectin. The fluid was also toxic to brine shrimp nauplii (LD50 141.25 µg protein/ml) and to mice injected intraperitoneally (LD50 201.8 ± 8.6 mg protein/kg), in a dose-dependent fashion. These toxic activities were abolished when the fluid was heated. Taken together, the data suggest that the activities of the purple fluid are due primarily to substance(s) of a protein nature which may be involved in the chemical defense mechanism of this sea hare.
Resumo:
The effect of peritoneal fluid (PF) on the human sperm acrosome reaction (AR) was tested. Sperm was pre-incubated with PF and the AR was induced by calcium ionophore A23187 and a neoglycoprotein bearing N-acetylglycosamine residues (NGP). The AR induced by calcium ionophore was inhibited 40% by PF from controls (PFc) and 50% by PF from the endometriosis (PFe) group, but not by PF from infertile patients without endometriosis (PFi). No significant differences were found in the spontaneous AR. When the AR was induced by NGP, pre-incubation with PFc reduced (60%) the percentage of AR, while PFe and PFi caused no significant differences. The average rates of acrosome reactions obtained in control, NGP- and ionophore-treated sperm showed that NGP-induced exocytosis differed significantly between the PFc (11%) and PFe/PFi groups (17%), and the ionophore-induced AR was higher for PFi (33%) than PFc/PFe (25%). The incidence of the NGP-induced AR was reduced in the first hour of pre-incubation with PFc and remained nearly constant throughout 4 h of incubation. The present data indicate that PF possesses a protective factor which prevents premature AR.
Resumo:
The application of computational fluid dynamics (CFD) and finite element analysis (FEA) has been growing rapidly in the various fields of science and technology. One of the areas of interest is in biomedical engineering. The altered hemodynamics inside the blood vessels plays a key role in the development of the arterial disease called atherosclerosis, which is the major cause of human death worldwide. Atherosclerosis is often treated with the stenting procedure to restore the normal blood flow. A stent is a tubular, flexible structure, usually made of metals, which is driven and expanded in the blocked arteries. Despite the success rate of the stenting procedure, it is often associated with the restenosis (re-narrowing of the artery) process. The presence of non-biological device in the artery causes inflammation or re-growth of atherosclerotic lesions in the treated vessels. Several factors including the design of stents, type of stent expansion, expansion pressure, morphology and composition of vessel wall influence the restenosis process. Therefore, the role of computational studies is crucial in the investigation and optimisation of the factors that influence post-stenting complications. This thesis focuses on the stent-vessel wall interactions followed by the blood flow in the post-stenting stage of stenosed human coronary artery. Hemodynamic and mechanical stresses were analysed in three separate stent-plaque-artery models. Plaque was modeled as a multi-layer (fibrous cap (FC), necrotic core (NC), and fibrosis (F)) and the arterial wall as a single layer domain. CFD/FEA simulations were performed using commercial software packages in several models mimicking the various stages and morphologies of atherosclerosis. The tissue prolapse (TP) of stented vessel wall, the distribution of von Mises stress (VMS) inside various layers of vessel wall, and the wall shear stress (WSS) along the luminal surface of the deformed vessel wall were measured and evaluated. The results revealed the role of the stenosis size, thickness of each layer of atherosclerotic wall, thickness of stent strut, pressure applied for stenosis expansion, and the flow condition in the distribution of stresses. The thicknesses of FC, and NC and the total thickness of plaque are critical in controlling the stresses inside the tissue. A small change in morphology of artery wall can significantly affect the distribution of stresses. In particular, FC is the most sensitive layer to TP and stresses, which could determine plaque’s vulnerability to rupture. The WSS is highly influenced by the deflection of artery, which in turn is dependent on the structural composition of arterial wall layers. Together with the stenosis size, their roles could play a decisive role in controlling the low values of WSS (<0.5 Pa) prone to restenosis. Moreover, the time dependent flow altered the percentage of luminal area with WSS values less than 0.5 Pa at different time instants. The non- Newtonian viscosity model of the blood properties significantly affects the prediction of WSS magnitude. The outcomes of this investigation will help to better understand the roles of the individual layers of atherosclerotic vessels and their risk to provoke restenosis at the post-stenting stage. As a consequence, the implementation of such an approach to assess the post-stented stresses will assist the engineers and clinicians in optimizing the stenting techniques to minimize the occurrence of restenosis.