1000 resultados para Monitoramento térmico


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work is grounded basically on the use of the Basic Tools for the Statistic Process Control SPC, with the intent to detect non-conformities on a given productive process. It consists on a case study accomplished at a Hemocenter in Natal (Rio Grande do Norte). In this study it is shown that, the Statistic Process Control Technique, which was used as a tool, is useful to identify on-conformities on the volume of hemocomponents. The gathering of the used data was performed by means of document analysis, direct observations and database queries. The results achieved from the study show that the analyzed products, even though when they have presented, in some cases, points out of control, they satisfied the ANVISA standards. Finally, suggestions for further improvement of the final product and guidance for future employment of CEP, also extended to other lines of production, are presented

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This Master Thesis presents a case study on the use of Statistical Process Control (SPC) at the Núcleo de Pesquisas em Alimentos e Medicamentos (NUPLAM). The SPC basic tools have been applied in the process of the tuberculostáticos drugs encapsulation, primarily concerning the objective to choose, between two speeds, which one is the best one to perform the tuberculostatics encapsulation. Later on, with the company effectively operating, the SPC was applied intending to know the variability of the process and, through the tracking of the process itself, to arrive at an estimated limit for the control of future lots of tuberculostatics of equal dosage. As special causes were detected acting in the process, a cause-and-effect diagram was built in order to try to discover, in each factor that composes the productive process, the possible causes of variation of the capsules average weight. The hypotheses raised will be able to serve as a base for deepened the study to eliminate or reduce these interferences in the process. Also a study on the capacity of the process to attend the specifications was carried out, and this study has shown the process´s inaptitude to take care of them. However, on the side of NUPLAM exists a real yearning to implant the SPC and consequently to improve the existing quality already present on its medicines

Relevância:

20.00% 20.00%

Publicador:

Resumo:

É apresentado um método para a estimativa do balanço térmico por radiação em vacas da raça Holandesa expostas ao sol e sob a sombra em uma pastagem, com o objetivo de estabelecer um padrão morfológico mais adequado para esses animais em região tropical. O método envolve a determinação das características do pelame (área de superfície de malhas negras, espessura da capa, comprimento e diâmetro dos pêlos, número de pêlos por unidade de área), temperatura da superfície da capa e da epiderme e variáveis ambientais (irradiância solar, temperatura do ar e de globo, vento). Foi determinada a quantidade de radiação de ondas curtas efetivamente transmitida através do pelame e que atinge as camadas profundas da epiderme. Demonstrou-se, por intermédio de um exemplo prático, que as áreas de pelame negro apresentaram balanço radiante mais elevado que as áreas brancas, mas estas últimas possuiam maior transmissividade para a radiação de ondas curtas. Animais predominantemente negros foram melhor protegidos contra a radiação de ondas curtas que os predominantemente brancos, especialmente quando a capa de pelame é pouco espessa (até 4 a 7 mm), mais adequada para ambientes tropicais.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The traditional processes for treatment of hazardous waste are questionable for it generates other wastes that adversely affect people s health. As an attempt to minimize these problems, it was developed a system for treatment of hazardous waste by thermal plasma, a more appropriate technology since it produces high temperatures, preventing the formation of toxic pollutants to human beings. The present work brings out a solution of automation for this plant. The system has local and remote monitoring resources to ensure the operators security as well as the process itself. A special attention was given to the control of the main reactor temperature of the plant as it is the place where the main processing occurs and because it presents a complex mathematical model. To this, it was employed cascaded controls based on Fuzzy logic. A process computer, with a particular man-machine interface (MMI), provides information and controls of the plant to the operator, including by Internet. A compact PLC module is in charge of the central element of management automation and plant control which receives information from sensors, and sends it to the MMI

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work describes the study, the analysis, the project methodology and the constructive details of a high frequency DC/AC resonant series converter using sequential commutation techniques for the excitation of an inductive coupled thermal plasma torch. The aim of this thesis is to show the new modulation technique potentialities and to present a technological option for the high-frequency electronic power converters development. The resonant converter operates at 50 kW output power under a 400 kHz frequency and it is constituted by inverter cells using ultra-fast IGBT devices. In order to minimize the turn-off losses, the inverter cells operates in a ZVS mode referred by a modified PLL loop that maintains this condition stable, despite the load variations. The sequential pulse gating command strategy used it allows to operate the IGBT devices on its maximum power limits using the derating and destressing current scheme, as well as it propitiates a frequency multiplication of the inverters set. The output converter is connected to a series resonant circuit constituted by the applicator ICTP torch, a compensation capacitor and an impedance matching RF transformer. At the final, are presented the experimental results and the many tests achieved in laboratory as form to validate the proposed new technique

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The area of the hospital automation has been the subject a lot of research, addressing relevant issues which can be automated, such as: management and control (electronic medical records, scheduling appointments, hospitalization, among others); communication (tracking patients, staff and materials), development of medical, hospital and laboratory equipment; monitoring (patients, staff and materials); and aid to medical diagnosis (according to each speciality). This thesis presents an architecture for a patient monitoring and alert systems. This architecture is based on intelligent systems techniques and is applied in hospital automation, specifically in the Intensive Care Unit (ICU) for the patient monitoring in hospital environment. The main goal of this architecture is to transform the multiparameter monitor data into useful information, through the knowledge of specialists and normal parameters of vital signs based on fuzzy logic that allows to extract information about the clinical condition of ICU patients and give a pre-diagnosis. Finally, alerts are dispatched to medical professionals in case any abnormality is found during monitoring. After the validation of the architecture, the fuzzy logic inferences were applied to the trainning and validation of an Artificial Neural Network for classification of the cases that were validated a priori with the fuzzy system

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The greater part of monitoring onshore Oil and Gas environment currently are based on wireless solutions. However, these solutions have a technological configuration that are out-of-date, mainly because analog radios and inefficient communication topologies are used. On the other hand, solutions based in digital radios can provide more efficient solutions related to energy consumption, security and fault tolerance. Thus, this paper evaluated if the Wireless Sensor Network, communication technology based on digital radios, are adequate to monitoring Oil and Gas onshore wells. Percent of packets transmitted with successful, energy consumption, communication delay and routing techniques applied to a mesh topology will be used as metrics to validate the proposal in the different routing techniques through network simulation tool NS-2

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of Geographic Information Systems (GIS) has becoming very important in fields where detailed and precise study of earth surface features is required. Applications in environmental protection are such an example that requires the use of GIS tools for analysis and decision by managers and enrolled community of protected areas. In this specific field, a challenge that remains is to build a GIS that can be dynamically fed with data, allowing researchers and other agents to recover actual and up to date information. In some cases, data is acquired in several ways and come from different sources. To solve this problem, some tools were implemented that includes a model for spatial data treatment on the Web. The research issues involved start with the feeding and processing of environmental control data collected in-loco as biotic and geological variables and finishes with the presentation of all information on theWeb. For this dynamic processing, it was developed some tools that make MapServer more flexible and dynamic, allowing data uploading by the proper users. Furthermore, it was also developed a module that uses interpolation to aiming spatial data analysis. A complex application that has validated this research is to feed the system with data coming from coral reef regions located in northeast of Brazil. The system was implemented using the best interactivity concept provided by the AJAX model and resulted in a substantial contribution for efficiently accessing information, being an essential mechanism for controlling events in the environmental monitoring

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of wireless sensor networks for control and monitoring functions has created a vibrant investigation scenario, covering since communication aspects to issues related with energy efficiency. When source sensors are endowed with cameras for visual monitoring, a new scope of challenges is raised, as transmission and monitoring requirements are considerably changed. Particularly, visual sensors collect data following a directional sensing model, altering the meaning of concepts as vicinity and redundancy but allowing the differentiation of source nodes by their sensing relevancies for the application. In such context, we propose the combined use of two differentiation strategies as a novel QoS parameter, exploring the sensing relevancies of source nodes and DWT image coding. This innovative approach supports a new scope of optimizations to improve the performance of visual sensor networks at the cost of a small reduction on the overall monitoring quality of the application. Besides definition of a new concept of relevance and the proposition of mechanisms to support its practical exploitation, we propose five different optimizations in the way images are transmitted in wireless visual sensor networks, aiming at energy saving, transmission with low delay and error recovery. Putting all these together, the proposed innovative differentiation strategies and the related optimizations open a relevant research trend, where the application monitoring requirements are used to guide a more efficient operation of sensor networks

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho apresenta um levantamento dos problemas associados à influência da observabilidade e da visualização radial no projeto de sistemas de monitoramento para redes de grande magnitude e complexidade. Além disso, se propõe a apresentar soluções para parte desses problemas. Através da utilização da Teoria de Redes Complexas, são abordadas duas questões: (i) a localização e a quantidade de nós necessários para garantir uma aquisição de dados capaz de representar o estado da rede de forma efetiva e (ii) a elaboração de um modelo de visualização das informações da rede capaz de ampliar a capacidade de inferência e de entendimento de suas propriedades. A tese estabelece limites teóricos a estas questões e apresenta um estudo sobre a complexidade do monitoramento eficaz, eficiente e escalável de redes

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The monitoring of patients performed in hospitals is usually done either in a manual or semiautomated way, where the members of the healthcare team must constantly visit the patients to ascertain the health condition in which they are. The adoption of this procedure, however, compromises the quality of the monitoring conducted since the shortage of physical and human resources in hospitals tends to overwhelm members of the healthcare team, preventing them from moving to patients with adequate frequency. Given this, many existing works in the literature specify alternatives aimed at improving this monitoring through the use of wireless networks. In these works, the network is only intended for data traffic generated by medical sensors and there is no possibility of it being allocated for the transmission of data from applications present in existing user stations in the hospital. However, in the case of hospital automation environments, this aspect is a negative point, considering that the data generated in such applications can be directly related to the patient monitoring conducted. Thus, this thesis defines Wi-Bio as a communication protocol aimed at the establishment of IEEE 802.11 networks for patient monitoring, capable of enabling the harmonious coexistence among the traffic generated by medical sensors and user stations. The formal specification and verification of Wi-Bio were made through the design and analysis of Petri net models. Its validation was performed through simulations with the Network Simulator 2 (NS2) tool. The simulations of NS2 were designed to portray a real patient monitoring environment corresponding to a floor of the nursing wards sector of the University Hospital Onofre Lopes (HUOL), located at Natal, Rio Grande do Norte. Moreover, in order to verify the feasibility of Wi-Bio in terms of wireless networks standards prevailing in the market, the testing scenario was also simulated under a perspective in which the network elements used the HCCA access mechanism described in the IEEE 802.11e amendment. The results confirmed the validity of the designed Petri nets and showed that Wi-Bio, in addition to presenting a superior performance compared to HCCA on most items analyzed, was also able to promote efficient integration between the data generated by medical sensors and user applications on the same wireless network

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hospital Automation is an area that is constantly growing. The emergency of new technologies and hardware is transforming the processes more efficient. Nevertheless, some of the hospital processes are still being performed manually, such as monitoring of patients that is considered critical because it involves human lives. One of the factors that should be taken into account during a monitoring is the agility to detect any abnormality in vital signs of patients, as well as warning of this anomaly to the medical team involved. So, this master's thesis aims to develop an architecture to automate this process of monitoring and reporting of possible alert to a professional, so that emergency care can be done effectively. The computing mobile was used to improve the communication by distributing messages between a central located into the hospital and the mobile carried by the duty

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work aimed at presenting analyses and comparisons of the thermal performance of a laying hens housing in the region of Bastos, in the state of São Paulo, adapted from natural alternatives of acclimatization, having a not adapted housing as reference, that is, of a more common typology in the area, and another one, artificially acclimatized. The index evaluated was the temperature and humidity (THI), the black globe temperature and humidity index (GTHI) and the thermal radiation charge (TRC). It was calculated from the measurement of the temperature of dry bulb, temperature of wet bulb, temperature of black globe and air speed. The measurements were made both in the intern and the extern environment, at four times (5 a.m, 11 a.m., 3 p.m. and 4 p.m. o'clock) and in two seasons (late spring and early summer), for ten days in a row. The results allow to conclude that the house naturally acclimatized (NA) has presented intermediate performance as compared with the others, making it to possible to control environment at adequate levels only during spring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)