967 resultados para Measuring instruments.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

对薄板成形应变场传统的测量方法进行了研究,指出了其不足和误差的来源,提出了数字图像分析法测量薄板成形中的应变场,对测量原理、新的测量方法对传统方法的改进,以及如何降低误差进行了介绍,指出数字图像分析法的前景,提出了改进意见。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is increased interest in measuring kinetic rates, lifetimes, and rupture forces of single receptor/ligand bonds. Valuable insights have been obtained from previous experiments attempting such measurements. However, it remains difficult to know with sufficient certainty that single bonds were indeed measured. Using exemplifying data, evidence supporting single-bond observation is examined and caveats in the experimental design and data interpretation are identified. Critical issues preventing definitive proof and disproof of single-bond observation include complex binding schemes, multimeric interactions, clustering, and heterogeneous surfaces. It is concluded that no single criterion is sufficient to ensure that single bonds are actually observed. However, a cumulative body of evidence may provide reasonable confidence. 0 2002 Biomedical Engineering Society.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An optical diagnostic system consisting of the Michelson interferometer with the image processor has been developed for the study of the kinetics of the thermal capillary convection. The capillary convection, surface deformation, surface wave and the velocity field in a rectangular cavity with different temperature's sidewalls have been investigated by optical interference method and PIV technique. In order to calculate the surface deformation from the interference fringe, Fourier transformation is used to grating analysis. The quantitative results of the surface deformation and surface wave have been calculated from the interference fringe pattern.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

采用一种非接触的光学方法傅立叶变换莫尔法(Fourier transform method),结合数字图像处理技术,对微幅振荡的水表面波的振幅进行测量.它是对全场中每一个像素点进行测量,比接触测量法具有更高的灵敏度.它为微幅水表面波振幅的测量提供了一种手段.通过将计算机生成的周期性光栅图像经投影机直接投影到被测物体的参考平面,经CCD摄像头、图像板捕捉存储形成数字化的光栅图像,利用傅立叶变换莫尔法处理光栅图像,从而获得包含有水表面波的振幅的相位信息,再经适当的几何变换获得振幅信息.我们在垂直振荡装置上进行了不同激励频率和不同振幅的表面波的振幅测量.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A portable mat for measuring the dynamic tire forces of commercial vehicles is described. The mat is 56 m long and 13 mm thick and has 141 capacitative strip sensors spaced at 0.4-m intervals. The accuracy of the mat for measuring dynamic tire forces generated by heavy commercial vehicles is assessed using an instrumented vehicle. The spatial repeatability of dynamic wheel loads generated by 14 uninstrumented articulated vehicles is investigated, and it is concluded that approximately half of the vehicles tested are likely to contribute to a repeatable pattern of road loading.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Decisions concerning maintenance have become increasingly important and requires a diverse set of information as systems become more complex. The availability of information has an impact on the effectiveness of these decisions, and thus on the performance of the asset. This paper highlights the importance of quantifying the value of information on maintenance decisions and asset performance. In particular, we emphasise the need to focus on measuring value as opposed to cost of maintenance, which is the current practice. In this direction, we propose a measure - Value of Ownership (VOO) - to assess the value of information and performance of maintenance decisions throughout an assets lifecycle. © 2009 IFAC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement of void fraction is of importance to the oil industry and chemical industry. In this article, the principle and mathematical method of determining the void fraction of horizontal gas-liquid flow by using a single-energy gamma-ray system is described. The gamma-ray source is the radioactive isotope of Am-241 with gamma-ray energy of 59.5 keV. The time-averaged value of the void fraction in a 50.0-mm i.d. transparent horizontal pipeline is measured under various combinations of the liquid flow and gas flow. It is found that increasing the gas flow rate at a fixed liquid flow rate would increase the void fraction. Test data are compared with the predictions of the correlations and a good agreement is found. The result shows that the designed gamma-ray system can be used for measuring the void fraction in a horizontal gas-liquid two-phase flow with high accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surface plasmon resonance (SPR) technology and the Biacore biosensor have been widely used to measure the kinetics of biomolecular interactions in the fluid phase. In the past decade, the assay was further extended to measure reaction kinetics when two counterpart molecules are anchored on apposed surfaces. However, the cell binding kinetics has not been well quantified. Here we report development of a cellular kinetic model, combined with experimental procedures for cell binding kinetic measurements, to predict kinetic rates per cell. Human red blood cells coated with bovine serum albumin and anti-BSA monoclonal antibodies (mAbs) immobilized on the chip were used to conduct the measurements. Sensor-grams for BSA-coated RBC binding onto and debinding from the anti-BSA mAb-immobilized chip were obtained using a commercial Biacore 3000 biosensor, and analyzed with the cellular kinetic model developed. Not only did the model fit the data well, but it also predicted cellular on and off-rates as well as binding affinities from curve fitting. The dependence of flow duration, flow rate, and site density of BSA on binding kinetics was tested systematically, which further validated the feasibility and reliability of the new approach. Crown copyright (c) 2008 Published by Elsevier Inc. All rights reserved.