894 resultados para Measurement in tank
Resumo:
This paper aims to survey data to analyze the productive capacity of a machining process of rolling bearings by methods-time measurement, in order to identify its bottlenecks and propose improvements in the system. The production times at the company are not known, the method of separation of operations and identification of its activities and the timing of production times and setup become points of departure for this paper. The results from this method of analysis provide clarity in identifying system weaknesses and by them it was possible to carry out the proposals for improvement in some process steps. The implementation of the improvements was not performed, but with the goals of this work was made possible to raise relevant information of the analyzed system
Resumo:
It is imortant to be able to evaluate the cardiact size . In 1995, was proposed by Buchanan and Bücheler a new way to measure the dimensions of the cardiac silhouette. This study aims to gather several studies of the cardiac dimensions by VHS method in the right lateral recumbency of of different breeds of dogs in a single work, facilitating the assess to information. Deep chest breeds have a smaller mean VHS value than the barrel chest breeds, showing that there is a variation of the VHS values acoording to the thoracic conformation of each breed, which indicates that there is a need to recognize the specific VHS values according to the breed standard to not to interpret the cardiac measurement in a wrong way through not compatible reference values for the animal. There is the individual variation that should be taken into accont at the time of measurement. The VHS is a helper method to a radiographic evaluation of the heart, and the ultrasonography remains the gold standard for the evaluation of the cardiac chambers and other changes of the heart
Resumo:
Pós-graduação em Biociências - FCLAS
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
O estresse oxidativo, decorrente de uma atividade física, leva a peroxidação lipídica de membranas celulares, além de danos protéicos e em ácidos nucléicos, e um dos produtos finais desta reação é o malondialdeído (MDA). A glutationa reduzida (GSH), considerada um antioxidante multifuncional, está presente no plasma e principalmente nas hemácias e tem importância pelo fato de ser um dos índices da capacidade total antioxidante do corpo após um estresse oxidativo. Com o objetivo de avaliar o estresse oxidativo em diferentes condições de treinamento físico, determinaram-se a concentração de MDA sérico e GSH eritrocitária em 45 cavalos da raça American Trotter e mestiços divididos em três grupos: G1 (sem treinamento), G2 (até 6 meses de treinamento) e G3 (treinamento há mais de 12 meses). Observou-se que o MDA teve um valor significativamente menor no grupo de animais sem treinamento físico. Não houve diferença estatística significante para GSH corrigida pela Hb e para GSH corrigida pelo VG entre os grupos analisados, mas houve uma aparente tendência a maiores valores no G2, no qual o sistema antioxidante está em fase de adaptação ao treinamento físico constante e suas consequentes injúrias. Conclui-se que a atividade física acarreta danos celulares frente ao estresse oxidativo, mas o sistema antioxidante tem papel fundamental nesta homeostasia observando uma adaptação às injúrias causadas pelos radicais livres.
Resumo:
Abstract Background: Coactivation may be both desirable (injury prevention) or undesirable (strength measurement). In this context, different styles of muscle strength stimulus have being investigated. In this study we evaluated the effects of verbal and visual stimulation on rectus femoris and biceps femoris muscles contraction during isometric and concentric. Methods: We investigated 13 men (age =23.1 ± 3.8 years old; body mass =75.6 ± 9.1 kg; height =1.8 ± 0.07 m). We used the isokinetic dynamometer BIODEX device and an electromyographic (EMG) system. We evaluated the maximum isometric and isokinetic knee extension and flexion at 60°/s. The following conditions were evaluated: without visual nor verbal command (control); verbal command; visual command and; verbal and visual command. In relation to the concentric contraction, the volunteers performed five reciprocal and continuous contractions at 60°/s. With respect to isometric contractions it was made three contractions of five seconds for flexion and extension in a period of one minute. Results: We found that the peak torque during isometric flexion was higher in the subjects in the VVC condition (p > 0.05). In relation to muscle coactivation, the subjects presented higher values at the control condition (p > 0.05). Conclusion We suggest that this type of stimulus is effective for the lower limbs.
Resumo:
Máster Oficial en Cultivos Marinos. Trabajo presentado como requisito parcial para la obtención del Título de Máster Oficial en Cultivos Marinos, otorgado por la Universidad de Las Palmas de Gran Canaria (ULPGC), el Instituto Canario de Ciencias Marinas (ICCM), y el Centro Internacional de Altos Estudios Agronómicos Mediterráneos de Zaragoza (CIHEAM)
Resumo:
Admission blood lactate concentration has been shown to be a useful indicator of disease severity in human medicine and numerous studies have associated hyperlactatemia with patients at high risk of death who should be treated aggressively regardless of the cause of the lactate generation. The degree and duration of hyperlactacidaemia also have been correlated with the subsequent development of organ failure. Similarly, in a small number of studies about equine colic, blood lactate concentration has been investigated as a useful prognostic variable . In neonatal foals blood lactate was studied first by Magdesian (2003) who described venous blood lactate concentration in 14 normal foals during the initial 48 hours post-partum. A preliminary study about lactate concentration in foals presenting to a neonatal intensive care unit reported that surviving foals had earlier lactate clearance. The measurement of blood lactate concentration is traditionally available with a wet chemistry laboratory method or with blood-gas analyzers, for clinicians working at university or large private hospital. But this methods may not be easily accessible to many practitioners in field conditions. Several relatively inexpensive, easy to use and rapid pocket size monitors to measure lactate concentration have been validated in human patients and athletes. None of these portable lactate analyzer have been evaluated in clinically normal neonatal foals or in foals referred to a neonatal intensive care unit. The aims of this study were to validate the Lactate Scout analyzer in neonatal foals, investigating the correlation between lactate concentration in whole blood measured with the portable monitor and measured in plasma with the reference laboratory analyzer. The effect of hematocrit (Hct) on the accuracy of Lactate Scout was also evaluated. Further, we determined the utility of venous lactate measurement in critically-ill foals, describing lactate values in the most frequent neonatal pathologies, evaluating serial blood lactate measurements during hospitalization and investigating its prognostic value. The study also describes normal range for lactate in healthy neonatal foals during the first 72 hours of life.
Resumo:
Water resources management will become increasingly important in agriculture as global warming takes place. Cover crop is largely used in viticultural areas based on the many positive agronomic and environmental benefits it provides. However, it is not clear what effect the cover crop can have on water use in the vineyard. This study is designed to develop a further understanding of the role cover crops play in total water use in the vineyard and develop our understanding of the potential use of cover crops as a water management tool. Two techniques were used to measure cover crop water use, the mini-lysimeters and a portable open chamber and data from both was compared to reference evapotranspiration (ETo) (FAO guidelines). While the mini-lysimeters seemed to be limited in their ability to accurately represent the water use of the surrounding soil, the open chamber method is a reliable and suitable instrument to be used for the accurate measurement of evapotranspiration. Further, the relationship between vineyard grass water use and the contributing environmental factors thought to influence water use were analyzed. A strong relationship between total available radiation and cover crop evapotranspiration was found suggesting the possibility of an indirect method of evapotranspiration measurement in a vineyard grass cover crop. Mowing the cover crop was determined to significantly effect transpiration as shown by both the mini-lysimeter and open chamber, however, the reduction was largely dependent on the growth rate of the grass.
Resumo:
Several MCAO systems are under study to improve the angular resolution of the current and of the future generation large ground-based telescopes (diameters in the 8-40 m range). The subject of this PhD Thesis is embedded in this context. Two MCAO systems, in dierent realization phases, are addressed in this Thesis: NIRVANA, the 'double' MCAO system designed for one of the interferometric instruments of LBT, is in the integration and testing phase; MAORY, the future E-ELT MCAO module, is under preliminary study. These two systems takle the sky coverage problem in two dierent ways. The layer oriented approach of NIRVANA, coupled with multi-pyramids wavefront sensors, takes advantage of the optical co-addition of the signal coming from up to 12 NGS in a annular 2' to 6' technical FoV and up to 8 in the central 2' FoV. Summing the light coming from many natural sources permits to increase the limiting magnitude of the single NGS and to improve considerably the sky coverage. One of the two Wavefront Sensors for the mid- high altitude atmosphere analysis has been integrated and tested as a stand- alone unit in the laboratory at INAF-Osservatorio Astronomico di Bologna and afterwards delivered to the MPIA laboratories in Heidelberg, where was integrated and aligned to the post-focal optical relay of one LINC-NIRVANA arm. A number of tests were performed in order to characterize and optimize the system functionalities and performance. A report about this work is presented in Chapter 2. In the MAORY case, to ensure correction uniformity and sky coverage, the LGS-based approach is the current baseline. However, since the Sodium layer is approximately 10 km thick, the articial reference source looks elongated, especially when observed from the edge of a large aperture. On a 30-40 m class telescope, for instance, the maximum elongation varies between few arcsec and 10 arcsec, depending on the actual telescope diameter, on the Sodium layer properties and on the laser launcher position. The centroiding error in a Shack-Hartmann WFS increases proportionally to the elongation (in a photon noise dominated regime), strongly limiting the performance. To compensate for this effect a straightforward solution is to increase the laser power, i.e. to increase the number of detected photons per subaperture. The scope of Chapter 3 is twofold: an analysis of the performance of three dierent algorithms (Weighted Center of Gravity, Correlation and Quad-cell) for the instantaneous LGS image position measurement in presence of elongated spots and the determination of the required number of photons to achieve a certain average wavefront error over the telescope aperture. An alternative optical solution to the spot elongation problem is proposed in Section 3.4. Starting from the considerations presented in Chapter 3, a first order analysis of the LGS WFS for MAORY (number of subapertures, number of detected photons per subaperture, RON, focal plane sampling, subaperture FoV) is the subject of Chapter 4. An LGS WFS laboratory prototype was designed to reproduce the relevant aspects of an LGS SH WFS for the E-ELT and to evaluate the performance of different centroid algorithms in presence of elongated spots as investigated numerically and analytically in Chapter 3. This prototype permits to simulate realistic Sodium proles. A full testing plan for the prototype is set in Chapter 4.
Resumo:
Der radiative Zerfall eines Hyperons in ein leichteres Hyperon und ein Photon erlaubt eine Untersuchung der Struktur der elektroschwachen Wechselwirkung von Hadronen. Dazu wird die Zerfallsasymmetrie $alpha$ betrachtet. Sie beschreibt die Verteilung des Tochterhyperons bezüglich der Polarisation $vec{P}$ des Mutterhyperons mit $dN / d cos(Theta) propto 1 + alpha |vec{P}| cos(Theta)$, wobei $Theta$ der Winkel zwischen $vec{P}$ und dem Impuls des Tochterhyperons ist. Von besonderem Interesse ist der radiative Zerfall $Xi^0 to Lambda gamma$, für den alle Rechnungen auf Quarkniveau eine positive Asymmetrie vorhersagen, wohingegen bisher eine negative Asymmetrie von $alpha_{Lambda gamma} = -0,73 +- 0,17$ gemessen wurde. Ziel dieser Arbeit war es, die bisherigen Messungen zu überprüfen und die Asymmetrie mit einer deutlich höheren Präzision zu bestimmen. Ferner wurden die Zerfallsasymmetrie des radiativen Zerfalls $Xi^0 to Sigma^0 gamma$ ermittelt und zum Test der angewandten Analysemethode der gut bekannte Zerfall $Xi^0 to Lambda pi^0$ herangezogen. Während der Datennahme im Jahr 2002 zeichnete das NA48/1-Experiment am CERN gezielt seltene $K_S$- und Hyperonzerfälle auf. Damit konnte der weltweit größte Datensatz an $Xi^0$-Zerfällen gewonnen werden, aus dem etwa 52.000 $Xi^0 to Lambda gamma$-Zerfälle, 15.000 $Xi^0 to Sigma^0 gamma$-Zerfälle und 4 Mill. $Xi^0 to Lambda pi^0$-Zerfälle mit nur geringem Untergrund extrahiert wurden. Ebenso wurden die entsprechenden $antiXi$-Zerfälle mit etwa einem Zehntel der obigen Ereigniszahlen registriert. Die Bestimmung der Zerfallsasymmetrien erfolgte durch den Vergleich der gemessene Daten mit einer detaillierten Detektorsimulation und führte zu den folgenden Resultaten dieser Arbeit: $alpha_{Lambda gamma} = -0,701 +- 0,019_{stat} +- 0,064_{sys}$, $alpha_{Sigma^0 gamma} = -0,683 +- 0,032_{stat} +- 0,077_{sys}$, $alpha_{Lambda pi^0} = -0,439 +- 0,002_{stat} +- 0,056_{sys}$, $alpha_{antiLambda gamma} = 0,772 +- 0,064_{stat} +- 0,066_{sys}$, $alpha_{antiSigma^0 gamma} = 0,811 +- 0,103_{stat} +- 0,135_{sys}$, $alpha_{antiLambda pi^0} = 0,451 +- 0,005_{stat} +- 0,057_{sys}$. Somit konnte die Unsicherheit der $Xi^0 to Lambda gamma$-Zerfallsasymmetrie auf etwa ein Drittel reduziert werden. Ihr negatives Vorzeichen und damit der Widerspruch zu den Vorhersagen der Quarkmodellrechnungen ist so zweifelsfrei bestätigt. Mit den zum ersten Mal gemessenen $antiXi$-Asymmetrien konnten zusätzlich Grenzen auf eine mögliche CP-Verletzung in den $Xi^0$-Zerfällen, die $alpha_{Xi^0} neq -alpha_{antiXi}$ zur Folge hätte, bestimmt werden.