996 resultados para MCNP5, curve isodose, raggi X


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Biomédica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia do Ambiente, perfil Gestão e Sistemas Ambientais

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional film based X-ray imaging systems are being replaced by their digital equivalents. Different approaches are being followed by considering direct or indirect conversion, with the later technique dominating. The typical, indirect conversion, X-ray panel detector uses a phosphor for X-ray conversion coupled to a large area array of amorphous silicon based optical sensors and a couple of switching thin film transistors (TFT). The pixel information can then be readout by switching the correspondent line and column transistors, routing the signal to an external amplifier. In this work we follow an alternative approach, where the electrical switching performed by the TFT is replaced by optical scanning using a low power laser beam and a sensing/switching PINPIN structure, thus resulting in a simpler device. The optically active device is a PINPIN array, sharing both front and back electrical contacts, deposited over a glass substrate. During X-ray exposure, each sensing side photodiode collects photons generated by the scintillator screen (560 nm), charging its internal capacitance. Subsequently a laser beam (445 nm) scans the switching diodes (back side) retrieving the stored charge in a sequential way, reconstructing the image. In this paper we present recent work on the optoelectronic characterization of the PINPIN structure to be incorporated in the X-ray image sensor. The results from the optoelectronic characterization of the device and the dependence on scanning beam parameters are presented and discussed. Preliminary results of line scans are also presented. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Smart grids with an intensive penetration of distributed energy resources will play an important role in future power system scenarios. The intermittent nature of renewable energy sources brings new challenges, requiring an efficient management of those sources. Additional storage resources can be beneficially used to address this problem; the massive use of electric vehicles, particularly of vehicle-to-grid (usually referred as gridable vehicles or V2G), becomes a very relevant issue. This paper addresses the impact of Electric Vehicles (EVs) in system operation costs and in power demand curve for a distribution network with large penetration of Distributed Generation (DG) units. An efficient management methodology for EVs charging and discharging is proposed, considering a multi-objective optimization problem. The main goals of the proposed methodology are: to minimize the system operation costs and to minimize the difference between the minimum and maximum system demand (leveling the power demand curve). The proposed methodology perform the day-ahead scheduling of distributed energy resources in a distribution network with high penetration of DG and a large number of electric vehicles. It is used a 32-bus distribution network in the case study section considering different scenarios of EVs penetration to analyze their impact in the network and in the other energy resources management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Basidiomycete strains synthesize several types of beta-D-glucans, which play a major role in the medicinal properties of mushrooms. Therefore, the specific quantification of these beta-D-glucans in mushroom strains is of great biochemical importance. Because published assay methods for these beta-D-glucans present some disadvantages, a novel colorimetric assay method for beta-D-glucan with alcian blue dye was developed. The complex formation was detected by following the decrease in absorbance in the range of 620 nm and by hypsochromic shift from 620 to 606 nm (similar to 14 nm) in UV-Vis spectrophotometer. Analysis of variance was used for optimization of the slope of the calibration curve by using the assay mixture containing 0.017% (w/v) alcian blue in 2% (v/v) acetic acid at pH 3.0. The high-throughput colorimetric assay method on microtiter plates was used for quantification of beta-D-glucans in the range of 0-0.8 mu g, with a slope of 44.15 x 10(-2) and a limit of detection of 0.017 mu g/well. Recovery experiments were carried out by using a sample of Hericium erinaceus, which exhibited a recovery of 95.8% for beta-1,3-D-glucan. The present assay method exhibited a 10-fold higher sensitivity and a 59-fold lower limit of detection compared with the published method with congo red beta-D-glucans of several mushrooms strains were isolated from fruiting bodies and mycelia, and they were quantified by this assay method. This assay method is fast, specific, simple, and it can be used to quantify beta-D-glucans from other biological sources. (C) 2015 American Institute of Chemical Engineers

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do grau de Doutor em Ciência dos Materiais, especialidade de Metalurgia, pela Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada no Departamento de Física na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Biomédica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

X-Ray Spectrom. 2003; 32: 396–401

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Biomédica

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMO - Na radiologia de intervenção, e concretamente em ortopedia, os raios X são intensamente utilizados permitindo a visualização de diversas técnicas de intervenção cirúrgica. Do ponto de vista médico as vantagens dessa prática são enormes, contudo, os profissionais de saúde envolvidos são susceptíveis de estarem expostos a valores de dose de radiação que significam a sua classificação como trabalhadores expostos. O presente estudo realizou-se num hospital e teve como objectivo obter uma estimativa das doses envolvidas em ortopedia de intervenção, utilizando várias metodologias experimentais para caracterização do campo de radiação primário e secundário. Observaram-se distintos níveis de dose de acordo com a zona anatómica exposta à radiação X: (i) gónadas — 0,02 a 3 mGy/h; (ii) cristalino — 0,06 a 1 mGy/h e (iii) mãos — 0,6 mGy/h. Tais resultados evidenciam uma clara necessidade de utilização de equipamentos de protecção e de vigilância dosimétrica pelos profissionais de saúde envolvidos no acto cirúrgico.--------------------------ABSTRACT - In intervention radiology, and more specifically in orthopaedics, X-rays are intensely used allowing the visualization of many acts of clinical intervention. From a clinical perspective, the advantages of that practice are significant; however, involved health care professionals are susceptible of being exposed to radiation dose values that mean their classification as exposed workers. The present study, performed in a hospital, aimed to obtain an estimation of the doses involved in intervention orthopaedics through several experimental methodologies in order to characterise the primary and the secondary radiation fields. Different levels of dose were observed according to the anatomic area exposed to X radiation: (i) gonads — 0.02 a 3 mGy/h; (ii) crystalline lens — 0.06 a 1 mGy/h e (iii) hands – 0.6 mGy/h. Such results denote a clear need of protection equipment use and of dosimetric surveillance by the health