948 resultados para Low signal-to-noise ratio regime
Resumo:
With the increasing importance that nanotechnologies have in everyday life, it is not difficult to realize that also a single molecule, if properly designed, can be a device able to perform useful functions: such a chemical species is called chemosensor, that is a molecule of abiotic origin that signals the presence of matter or energy. Signal transduction is the mechanism by which an interaction of a sensor with an analyte yields a measurable form of energy. When dealing with the design of a chemosensor, we need to take into account a “communication requirement” between its three component: the receptor unit, responsible for the selective analyte binding, the spacer, which controls the geometry of the system and modulates the electronic interaction between the receptor and the signalling unit, whose physico-chemical properties change upon complexation. A luminescent chemosensor communicates a variation of the physico-chemical properties of the receptor unit with a luminescence output signal. This thesis work consists in the characterization of new molecular and nanoparticle-based system which can be used as sensitive materials for the construction of new optical transduction devices able to provide information about the concentration of analytes in solution. In particular two direction were taken. The first is to continue in the development of new chemosensors, that is the first step for the construction of reliable and efficient devices, and in particular the work will be focused on chemosensors for metal ions for biomedical and environmental applications. The second is to study more efficient and complex organized systems, such as derivatized silica nanoparticles. These system can potentially have higher sensitivity than molecular systems, and present many advantages, like the possibility to be ratiometric, higher Stokes shifts and lower signal-to-noise ratio.
Resumo:
In case of violation of CPT- and Lorentz Symmetry, the minimal Standard Model Extension (SME) of Kostelecky and coworkers predicts sidereal modulations of atomic transition frequencies as the Earth rotates relative to a Lorentz-violating background field. One method to search for these modulations is the so-called clock-comparison experiment, where the frequencies of co-located clocks are compared as they rotate with respect to the fixed stars. In this work an experiment is presented where polarized 3He and 129Xe gas samples in a glass cell serve as clocks, whose nuclear spin precession frequencies are detected with the help of highly sensitive SQUID sensors inside a magnetically shielded room. The unique feature of this experiment is the fact that the spins are precessing freely, with transverse relaxation times of up to 4.4 h for 129Xe and 14.1 h for 3He. To be sensitive to Lorentz-violating effects, the influence of external magnetic fields is canceled via the weighted difference of the 3He and 129Xe frequencies or phases. The Lorentz-violating SME parameters for the neutron are determined out of a fit on the phase difference data of 7 spin precession measurements of 12 to 16 hours length. The result of the fit gives an upper limit for the equatorial component of the neutron parameter b_n of 3.7×10^(−32) GeV at the 95% confidence level. This value is not limited by the signal-to-noise ratio, but by the strong correlations between the fit parameters. To reduce the correlations and therewith improve the sensitivity of future experiments, it will be necessary to change the time structure of the weighted phase difference, which can be realized by increasing the 129Xe relaxation time.
Bau und Entwicklung eines Applikators zur Verabreichung hyperpolarisierter Gase in der MRT der Lunge
Resumo:
Im Rahmen meiner Dissertation habe ich gemäß dem Medizinproduktegesetz ein MR-kompatibles Verabreichungsgerät entwickelt, um Patienten hyperpolarisierte Gas Boli (He-3, Xe-129) als Kontrasgas zur MRT der Lunge zu applizieren. Das Gerät wurde dazu optimiert, die Gase oder Gasmischungen (z. B. HP Gas + N2) in definierten Mengen und zu definierten Zeitpunkten während der Inspiration mit hoher Reproduzierbarkeit und Zuverlässigkeit zu verabreichen, ohne dabei die MR-Qualität zu beeinträchtigen. Aus Sicherheitsgründen und zur späteren Datenanalyse werden die Atemflusskurven der Patienten kontinuierlich angezeigt und aufgezeichnet. Ein Kolbenkompressor ist integriert, um die gesamte gespeicherte He-3-Menge nutzen zu können. Weiterhin ist es möglich, die Polarisation vor Ort zu bestimmen und das abgeatmete He-3 zur späteren Rückgewinnung aufzufangen. Diese Auffangeffizienz konnte durch Untersuchungen mit He-4 (als He-3-Ersatz) gesteigert werden.rnDie ersten MR-Aufnahmen von 10 gesunden Probanden wurden mit diesem Aufbau imrnRahmen einer klinischen Studie durchgeführt. Die Analyse der bestimmten MR-Parameter Signal-Rausch-Verhältnis (SNR), Sauerstoffpartialdruck (pO2), Scheinbarer Diffusionskoeffizient (ADC=apparent diffusion coefficient) sowie die Signalanstiegszeit (rise-time) zeigt eine deutlich bessere Reproduzierbarkeit bei der Verabreichung des He-3 mit dem Applikators anstelle eines Tedlarbags (= kleine heliumdichte Plastiktüte).
Resumo:
Die Invarianz physikalischer Gesetze unter Lorentztransformationen ist eines der fundamentalen Postulate der modernen Physik und alle Theorien der grundlegenden Wechselwirkungen sind in kovarianter Form formuliert. Obwohl die Spezielle Relativitätstheorie (SRT) in einer Vielzahl von Experimenten mit hoher Genauigkeit überprüft und bestätigt wurde, sind aufgrund der weitreichenden Bedeutung dieses Postulats weitere verbesserte Tests von grundsätzlichem Interesse. Darüber hinaus weisen moderne Ansätze zur Vereinheitlichung der Gravitation mit den anderen Wechselwirkungen auf eine mögliche Verletzung der Lorentzinvarianz hin. In diesem Zusammenhang spielen Ives-Stilwell Experimente zum Test der Zeitdilatation in der SRT eine bedeutende Rolle. Dabei wird die hochauflösende Laserspektroskopie eingesetzt, um die Gültigkeit der relativistischen Dopplerformel – und damit des Zeitdilatationsfaktors γ – an relativistischen Teilchenstrahlen zu untersuchen. Im Rahmen dieser Arbeit wurde ein Ives-Stilwell Experiment an 7Li+-Ionen, die bei einer Geschwindigkeit von 34 % der Lichtgeschwindigkeit im Experimentierspeicherring (ESR) des GSI Helmholtzzentrums für Schwerionenforschung gespeichert waren, durchgeführt. Unter Verwendung des 1s2s3S1→ 1s2p3P2-Übergangs wurde sowohl Λ-Spektroskopie als auch Sättigungsspektroskopie betrieben. Durch die computergestützte Analyse des Fluoreszenznachweises und unter Verwendung optimierter Kantenfilter für den Nachweis konnte das Signal zu Rauschverhältnis entscheidend verbessert und unter Einsatz eines zusätzlichen Pumplasers erstmals ein Sättigungssignal beobachtet werden. Die Frequenzstabilität der beiden verwendeten Lasersysteme wurde mit Hilfe eines Frequenzkamms spezifiziert, um eine möglichst hohe Genauigkeit zu erreichen. Die aus den Strahlzeiten gewonnen Daten wurden im Rahmen der Robertson-Mansouri-Sexl-Testtheorie (RMS) und der Standard Model Extension (SME) interpretiert und entsprechende Obergrenzen für die relevanten Testparameter der jeweiligen Theorie bestimmt. Die Obergrenze für den Testparameter α der RMS-Theorie konnte gegenüber den früheren Messungen bei 6,4 % der Lichtgeschwindigkeit am Testspeicherring (TSR) des Max-Planck-Instituts für Kernphysik in Heidelberg um einen Faktor 4 verbessert werden.
Resumo:
Um die in der Atmosphäre ablaufenden Prozesse besser verstehen zu können, ist es wichtig dort vorhandene Partikel gut charakterisieren zu können. Dazu gehört unter anderem die Bestimmung der chemischen Zusammensetzung der Partikel. Zur Analyse insbesondere organischer Partikel wurde dazu in einer früheren Promotion das Aerosol-Ionenfallen-Massenspektrometer (AIMS) entwickelt.Im Rahmen dieser Arbeit wurden Entwicklungsarbeiten durchgeführt, um die Charakteristiken des Prototypen zu verbessern sowie es für den Feldeinsatz tauglich zu machen. Die durchgeführten Veränderungen betreffen mechanische und elektrische Komponenten sowie das LabView Steuerungsprogramm. So wurde z.B. die Ionenquelle derart modifiziert, dass die Ionen nicht mehr permanent erzeugt werden, sondern nur innerhalb des Zeitraums wenn sie auch in der Ionenfalle gespeichert werden können. Durch diese Modifikation konnte das Signal-zu-Rausch Verhältnis deutlich verbessert werden. Nach Beendigung der Umbauten wurden in ausführlichen Laborstudien die einzelnen Instrumentenparameter detailliert charakterisiert. Neben den Spannungen die zur Fokussierung oder zur Speicherung der Ionen in der Ionenfalle dienen, wurden die unterschiedlichen Arten der resonanten Anregung, mittels der die Ionen in der Ionenfalle gezielt zu Schwingungen angeregt werden können, sehr genau untersucht. Durch eine gezielte Kombination der unterschiedlichen Arten der resonanten Anregung ist es möglich MSn-Studien durchzuführen. Nach erfolgreicher Charakterisierung konnte in weiteren Laborstudien die MSn-Fähigkeit des AIMS demonstriert werden. Für Tryptophan (C11H12N2O2) wurde anhand von MS4-Studien ausgehend von m/z 130 ein möglicher Fragmentierungsweg identifiziert. Für die einzelnen Stufen der MS4-Studien wurden die Nachweisgrenzen abgeschätzt. Im Rahmen der PARADE (PArticles and RAdicals: Diel observations of the impact of urban and biogenic Emissions) Messkampagne im August/September 2011 auf dem kleinen Feldberg in der Nähe von Frankfurt am Main wurde die Feldtauglichkeit des AIMS demonstriert. Die Nachweisgrenzen liegen für eine Mittelungszeit von 60 Minuten für Organik bei 1,4 µg m-3, für Nitrat bei 0,5 µg m-3 und für Sulfat bei 0,7 µg m-3, was ausreichend ist um atmosphärisches Aerosol messen zu können. Dies ist ein signifikanter Fortschritt im Vergleich zum Prototypen, der aufgrund schlechter Reproduzierbarkeit und Robustheit noch nicht feldtauglich war. Im Vergleich zum HR-ToF-AMS, einem Standard-Aerosolmassenspektrometer, zeigte sich, dass beide Instrumente vergleichbare Trends für die Spezies Nitrat, Sulfat und Organik messen.
Resumo:
Lo scopo di questo lavoro è la caratterizzazione fisica del flat panel PaxScan4030CB Varian, rivelatore di raggi X impiegato in un ampio spettro di applicazioni cliniche, dalla radiografia generale alla radiologia interventistica. Nell’ambito clinico, al fine di una diagnosi accurata, è necessario avere una buona qualità dell’immagine radiologica mantenendo il più basso livello di dose rilasciata al paziente. Elemento fondamentale per ottenere questo risultato è la scelta del rivelatore di radiazione X, che deve garantire prestazioni fisiche (contrasto, risoluzione spaziale e rumore) adeguati alla specifica procedura. Le metriche oggettive che misurano queste caratteristiche sono SNR (Signal-to-Noise Ratio), MTF (Modulation Transfer Function) ed NPS (Noise Power Spectrum), che insieme contribuiscono alla misura della DQE (Detective Quantum Efficiency), il parametro più completo e adatto a stabilire le performance di un sistema di imaging. L’oggettività di queste misure consente anche di mettere a confronto tra loro diversi sistemi di rivelazione. La misura di questi parametri deve essere effettuata seguendo precisi protocolli di fisica medica, che sono stati applicati al rivelatore PaxScan4030CB presente nel laboratorio del Centro di Coordinamento di Fisica Medica, Policlinico S.Orsola. I risultati ottenuti, conformi a quelli dichiarati dal costruttore, sono stati confrontati con successo con alcuni lavori presenti in letteratura e costituiscono la base necessaria per la verifica di procedure di ottimizzazione dell’immagine radiologica attraverso interventi sul processo di emissione dei raggi X e sul trattamento informatico dell’immagine (Digital Subtraction Angiography).
Resumo:
The problem of localizing a scatterer, which represents a tumor, in a homogeneous circular domain, which represents a breast, is addressed. A breast imaging method based on microwaves is considered. The microwave imaging involves to several techniques for detecting, localizing and characterizing tumors in breast tissues. In all such methods an electromagnetic inverse scattering problem exists. For the scattering detection method, an algorithm based on a linear procedure solution, inspired by MUltiple SIgnal Classification algorithm (MUSIC) and Time Reversal method (TR), is implemented. The algorithm returns a reconstructed image of the investigation domain in which it is detected the scatterer position. This image is called pseudospectrum. A preliminary performance analysis of the algorithm vying the working frequency is performed: the resolution and the signal-to-noise ratio of the pseudospectra are improved if a multi-frequency approach is considered. The Geometrical Mean-MUSIC algorithm (GM- MUSIC) is proposed as multi-frequency method. The performance of the GMMUSIC is tested in different real life computer simulations. The performed analysis shows that the algorithm detects the scatterer until the electrical parameters of the breast are known. This is an evident limit, since, in a real life situation, the anatomy of the breast is unknown. An improvement in GM-MUSIC is proposed: the Eye-GMMUSIC algorithm. Eye-GMMUSIC algorithm needs no a priori information on the electrical parameters of the breast. It is an optimizing algorithm based on the pattern search algorithm: it searches the breast parameters which minimize the Signal-to-Clutter Mean Ratio (SCMR) in the signal. Finally, the GM-MUSIC and the Eye-GMMUSIC algorithms are tested on a microwave breast cancer detection system consisting of an dipole antenna, a Vector Network Analyzer and a novel breast phantom built at University of Bologna. The reconstruction of the experimental data confirm the GM-MUSIC ability to localize a scatterer in a homogeneous medium.
Resumo:
The level of improvement in the audiological results of Baha(®) users mainly depends on the patient's preoperative hearing thresholds and the type of Baha sound processor used. This investigation shows correlations between the preoperative hearing threshold and postoperative aided thresholds and audiological results in speech understanding in quiet of 84 Baha users with unilateral conductive hearing loss, bilateral conductive hearing loss and bilateral mixed hearing loss. Secondly, speech understanding in noise of 26 Baha users with different Baha sound processors (Compact, Divino, and BP100) is investigated. Linear regression between aided sound field thresholds and bone conduction (BC) thresholds of the better ear shows highest correlation coefficients and the steepest slope. Differences between better BC thresholds and aided sound field thresholds are smallest for mid-frequencies (1 and 2 kHz) and become larger at 0.5 and 4 kHz. For Baha users, the gain in speech recognition in quiet can be expected to lie in the order of magnitude of the gain in their hearing threshold. Compared to its predecessor sound processors Baha(®) Compact and Baha(®) Divino, Baha(®) BP100 improves speech understanding in noise significantly by +0.9 to +4.6 dB signal-to-noise ratio, depending on the setting and the use of directional microphone. For Baha users with unilateral and bilateral conductive hearing loss and bilateral mixed hearing loss, audiological results in aided sound field thresholds can be estimated with the better BC hearing threshold. The benefit in speech understanding in quiet can be expected to be similar to the gain in their sound field hearing threshold. The most recent technology of Baha sound processor improves speech understanding in noise by an order of magnitude that is well perceived by users and which can be very useful in everyday life.
Resumo:
Two commercially available electrode catheters are examined for their suitability in esophageal long-term ECG recordings. Both, electrical sensing characteristics as well as clinical acceptance were investigated in a clinical study including inpatients with cardiovascular diseases. In total, 31 esophageal ECG were obtained in 36 patients. Results showed that esophageal electrodes were well tolerated by the patients. Hemispherical electrodes with higher diameter required more insertion attempts and were associated with increased failure rates as compared to cylindrical electrodes. In contrast, the higher surface area of hemispherical electrodes resulted in significantly higher signal-to-noise ratio. Contact impedance was equal for both electrode types, but esophageal electrodes had lower impedance if compared with skin electrodes.
Resumo:
Calcium influx into the dendritic tufts of layer 5 neocortical pyramidal neurons modifies a number of important cellular mechanisms. It can trigger local synaptic plasticity and switch the firing properties from regular to burst firing. Due to methodological limitations, our knowledge about Ca2+ spikes in the dendritic tuft stems mostly from in vitro experiments. However, it has been speculated that regenerative Ca2+ events in the distal dendrites correlate with distinct behavioral states. Therefore it would be most desirable to be able to record these Ca2+ events in vivo, preferably in the behaving animal. Here, we present a novel approach for recording Ca2+ signals in the dendrites of populations of layer 5 pyramidal neurons in vivo, which ensures that all recorded fluorescence changes are due to intracellular Ca2+ signals in the apical dendrites. The method has two main features: 1) bolus loading of layer 5 with a membrane-permeant Ca2+ dye resulting in specific loading of pyramidal cell dendrites in the upper layers and 2) a fiberoptic cable attached to a gradient index lens and a prism reflecting light horizontally at 90 degrees to the angle of the apical dendrites. We demonstrate that the in vivo signal-to-noise ratio recorded with this relatively inexpensive and easy-to-implement fiberoptic-based device is comparable to conventional camera-based imaging systems used in vitro. In addition, the device is flexible and lightweight and can be used for recording Ca2+ signals in the distal dendritic tuft of freely behaving animals.
Resumo:
Despite a broad range of collaboration tools already available, enterprises continue to look for ways to improve internal and external communication. Microblogging is such a new communication channel with some considerable potential to improve intra-firm transparency and knowledge sharing. However, the adoption of such social software presents certain challenges to enterprises. Based on the results of four focus group sessions, we identified several new constructs to play an important role in the microblogging adoption decision. Examples include privacy concerns, communication benefits, perceptions regarding signal-to-noise ratio, as well codification effort. Integrating these findings with common views on technology acceptance, we formulate a model to predict the adoption of a microblogging system in the workspace. Our findings serve as an important guideline for managers seeking to realize the potential of microblogging in their company.
Resumo:
BACKGROUND: Gray matter lesions are known to be common in multiple sclerosis (MS) and are suspected to play an important role in disease progression and clinical disability. A combination of magnetic resonance imaging (MRI) techniques, double-inversion recovery (DIR), and phase-sensitive inversion recovery (PSIR), has been used for detection and classification of cortical lesions. This study shows that high-resolution three-dimensional (3D) magnetization-prepared rapid acquisition with gradient echo (MPRAGE) improves the classification of cortical lesions by allowing more accurate anatomic localization of lesion morphology. METHODS: 11 patients with MS with previously identified cortical lesions were scanned using DIR, PSIR, and 3D MPRAGE. Lesions were identified on DIR and PSIR and classified as purely intracortical or mixed. MPRAGE images were then examined, and lesions were re-classified based on the new information. RESULTS: The high signal-to-noise ratio, fine anatomic detail, and clear gray-white matter tissue contrast seen in the MPRAGE images provided superior delineation of lesion borders and surrounding gray-white matter junction, improving classification accuracy. 119 lesions were identified as either intracortical or mixed on DIR/PSIR. In 89 cases, MPRAGE confirmed the classification by DIR/PSIR. In 30 cases, MPRAGE overturned the original classification. CONCLUSION: Improved classification of cortical lesions was realized by inclusion of high-spatial resolution 3D MPRAGE. This sequence provides unique detail on lesion morphology that is necessary for accurate classification.
Resumo:
Measurement of perfusion in longitudinal studies allows for the assessment of tissue integrity and the detection of subtle pathologies. In this work, the feasibility of measuring brain perfusion in rats with high spatial resolution using arterial spin labeling is reported. A flow-sensitive alternating recovery sequence, coupled with a balanced gradient fast imaging with steady-state precession readout section was used to minimize ghosting and geometric distortions, while achieving high signal-to-noise ratio. The quantitative imaging of perfusion using a single subtraction method was implemented to address the effects of variable transit delays between the labeling of spins and their arrival at the imaging slice. Studies in six rats at 7 T showed good perfusion contrast with minimal geometric distortion. The measured blood flow values of 152.5+/-6.3 ml/100 g per minute in gray matter and 72.3+/-14.0 ml/100 g per minute in white matter are in good agreement with previously reported values based on autoradiography, considered to be the gold standard.
Resumo:
AIM: To determine the feasibility of evaluating surgically induced hepatocyte damage using gadoxetate disodium (Gd-EOB-DTPA) as a marker for viable hepatocytes at magnetic resonance imaging (MRI) after liver resection. MATERIAL AND METHODS: Fifteen patients were prospectively enrolled in this institutional review board-approved study prior to elective liver resection after informed consent. Three Tesla MRI was performed 3-7 days after surgery. Three-dimensional (3D) T1-weighted (W) volumetric interpolated breath-hold gradient echo (VIBE) sequences covering the liver were acquired before and 20 min after Gd-EOB-DTPA administration. The signal-to-noise ratio (SNR) was used to compare the uptake of Gd-EOB-DTPA in healthy liver tissue and in liver tissue adjacent to the resection border applying paired Student's t-test. Correlations with potential influencing factors (blood loss, duration of intervention, age, pre-existing liver diseases, postoperative change of resection surface) were calculated using Pearson's correlation coefficient. RESULTS: Before Gd-EOB-DTPA administration the SNR did not differ significantly (p = 0.052) between healthy liver tissue adjacent to untouched liver borders [59.55 ± 25.46 (SD)] and the liver tissue compartment close to the resection surface (63.31 ± 27.24). During the hepatocyte-specific phase, the surgical site showed a significantly (p = 0.04) lower SNR (69.44 ± 24.23) compared to the healthy site (78.45 ± 27.71). Dynamic analyses revealed a significantly lower increase (p = 0.008) in signal intensity in the healthy tissue compared to the resection border compartment. CONCLUSION: EOB-DTPA-enhanced MRI may have the potential to be an effective non-invasive tool for detecting hepatocyte damage after liver resection.
Resumo:
Three methods for distortion-free enhancement of electro-optic sampling measurements of terahertz signals are tested. In the first part of this two-paper series [J. Opt. Soc. Am B 31, 904–910 (2014)], the theoretical framework for describing the signal enhancement was presented and discussed. As the applied optical bias is decreased, individual signal traces become enhanced but distorted. Here we experimentally show that nonlinear signal components that distort the terahertz electric field measurement can be removed by subtracting traces recorded with opposite optical bias values. In all three methods tested, we observe up to an order of magnitude increase in distortion-free signal enhancement, in agreement with the theory, making possible measurements of small terahertz-induced transient birefringence signals with increased signal-to-noise ratio.