968 resultados para Laser diodes


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Photons participate in many atomic and molecular interactions and processes. Recent biophysical research has discovered an ultraweak radiation in biological tissues. It is now recognized that plants, animal and human cells emit this very weak biophotonic emission which can be readily measured with a sensitive photomultiplier system. UVA laser induced biophotonic emission of cultured cells was used in this report with the intention to detect biophysical changes between young and adult fibroblasts as well as between fibroblasts and keratinocytes. With suspension densities ranging from 1-8x106 cells/ml, it was evident that an increase of the UVA-laser-light induced photon emission intensity could be observed in young as well as adult fibroblastic cells. By the use of this method to determine ultraweak light emission, photons in cell suspensions in low volumes (100 mu l) could be detected, in contrast to previous procedures using quantities up to 10 ml. Moreover, the analysis has been further refined by turning off the photomultiplier system electronically during irradiation leading to the first measurements of induced light emission in the cells after less than 10 mu s instead of more than 100 milliseconds. These significant changes lead to an improvement factor up to 106 in comparison to classical detection procedures. In addition, different skin cells as fibroblasts and keratinocytes stemining from the same donor were measured using this new highly sensitive method in order to find new biophysical insight of light pathways. This is important in view to develop new strategies in biophotonics especially for use in alternative therapies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare the results obtained after oral mucocele resection with the scalpel versus the CO2 laser, based on the complications and recurrences after surgery Patients and Methods: Of the 68 patients we studied who have mucocele, 38 were resected with a scalpel and the remaining 30 with the CO2 laser (5-7 W). Patient sex and age were documented, along with location of the lesion as well as size, symptoms, duration, etiological factors, type of treatment, complications and recurrences after surgical removal. Results: The sample comprised 40 males and 28 females, aged between 6-65 years. The histological diagnosis was extravasation mucocele in 95% of the cases. The most frequent location was the lower lip (73.5%). The mean lesion diameter was 9 mm , and in most cases no evident etiological factor was recorded. The mean duration of the lesion was 4 months. Among the cases of conventional surgical removal of mucocele, recurrence was recorded in 8.8% of the cases, and 13.2% of the patients suffered postoperative complications - the most frequent being the presence of fibrous scars. There were no complications or relapses after a minimum follow-up of 12 months in the cases subjected to CO2 laser treatment. Conclusions: Oral mucocele ablation with the CO2 laser offers more predictable results and fewer complications and recurrences than conventional resection with the scalpel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Benign Oral Vascular Lesions (BOVLs) are a group of vascular diseases characterized by congenital, inflammatory or neoplastic vascular dilations clinically evidenced as more or less wide masses of commonly dark bluish color. If traumatized BOVLs are characterized by a great risk of hemorrhage and their treatment usually requires great caution to prevent massive bleeding. In the last decades lasers have dramatically changed the way of treatment of BOVLs permitting the application of even peculiar techniques that gave interesting advantages in their management reducing hemorrhage risks. The aim of this study was to evaluate the capabilities and disadvantages of three laser assisted techniques in the management of BOVLs. Study design: In this study 13 BOVLs were treated by three different laser techniques: the traditional excisional biopsy (EB), and two less invasive techniques, the transmucosal thermocoagulation (TMT) and the intralesional photocoagulation (ILP). Two different laser devices were adopted in the study: a KTP laser (DEKA, Florence, Italy, 532nm) and a GaAlAs laser (Laser Innovation, Castelgandolfo, Italy, 808nm) selected since their great effectiveness on hemoglobin. Results: In each case, lasers permitted safe treatments of BOVLs without hemorrhages, both during the intervention and in the post-operative period. The minimally invasive techniques (TMT and ILP) permitted even the safe resolution of big lesions without tissue loss. Conclusions: Laser devices confirm to be the gold standard in BOVLs treatment, permitting even the introduction of minimal invasive surgery principles and reducing the risks of hemorrhage typical of these neoplasms. As usual in laser surgery, it is necessary a clear knowledge of the devices and of the laser-tissue interaction to optimize the results reducing risks and disadvantages

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a full field laser Doppler imaging instrument, which enables real-time in vivo assessment of blood flow in dermal tissue and skin. This instrument monitors the blood perfusion in an area of about 50 cm(2) with 480 × 480 pixels per frame at a rate of 12-14 frames per second. Smaller frames can be monitored at much higher frame rates. We recorded the microcirculation in healthy skin before, during and after arterial occlusion. In initial clinical case studies, we imaged the microcirculation in burned skin and monitored the recovery of blood flow in a skin flap during reconstructive surgery indicating the high potential of LDI for clinical applications. Small animal imaging in mouse ears clearly revealed the network of blood vessels and the corresponding blood perfusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To compare upper lip frenulum reinsertion, bleeding, surgical time and surgical wound healing in frenectomies performed with the CO2 laser versus the Er, Cr:YSGG laser. Study design: A prospective study was carried out on 50 randomized pediatric patients who underwent rhomboidal resection of the upper lip frenulum with either the CO2 laser or the Er,Cr:YSGG laser. Twenty-five patients were assigned to each laser system. All patients were examined at 7, 14, 21 days and 4 months after the operation in order to assess the surgical wound healing. Results: Insertion of the frenulum, which was preoperatively located between the upper central incisors, migrated to the mucogingival junction as a result of using both laser systems in all patients. Only two patients required a single dose of 650 mg of paracetamol, one of either study group. CO2 laser registered improved intraoperative bleeding control results and shorter surgical times. On the other hand, the Er,Cr:YSGG laser achieved faster healing. Conclusions: Upper lip laser frenectomy is a simple technique that results in minimum or no postoperative swelling or pain, and which involves upper lip frenulum reinsertion at the mucogingival junction. The CO2 laser offers a bloodless field and shorter surgical times compared with the Er,Cr:YSGG laser. On the other hand, the Er,Cr:YSGG laser achieved faster wound healing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the differences between the Fundus Camera (Topcon TRC-50X) and Confocal Scanning Laser Ophthalmoscope (Heidelberg retina angiogram (HRA)) on the fundus autofluorescence (FAF) imaging (resolution and FAF characteristics). Methods: Eighty nine eyes of 46 patients with various retinal diseases underwent FAF imaging with HRA (488nm exciter / 500nm barrier filter) before fluorescein angiography (FFA) and Topcon Fundus Camera (580nm exciter / 695nm barrier filter) before and after FFA. The quality of the FAF images was estimated, compared for their resolution and analysed for the influence of fixation stability and cataracts. Hypo- and hyper-FAF behaviour was analysed for the healthy disc, healthy fovea, and a variety of pathological features. Results: HRA images were found to be of superior quality in 18 eyes, while Topcon images were estimated superior in 21 eyes. No difference was found in 50 eyes. Both poor fixation (p=0.009) and more advanced cataract (p=0.013) were found to strongly increase the likelihood of better image quality by Topcon. Images acquired by Topcon before and after FFA were identical (100%). The healthy disc was usually dark on HRA (71%), but showed mild autofluorescence on Topcon (88%). The healthy fovea showed in 100% Hypo-FAF on HRA, while Topcon showed in 52% Iso-FAF, in 43% mild Hypo-FAF, and in 5% Hypo-FAF as on HRA. No difference of FAF was found for geographic atrophy, pigment changes, and drusen, although Topcon images were often more detailed. Hyper-FAF due to exudation showed better on HRA. Pigment epithelium detachment showed identical FAF behaviour on the border, but reduced FAF with Topcon in the center. Cystic edema was visible only on HRA in a petaloid pattern. Hard exsudates caused Hypo-FAF only on HRA, hardly visible on Topcon. Blocage phenomenon by blood however was identical. Conclusions: The filter set of Topcon and the single image acquisition appear to be an advantage for patients with cataract or poor fixation. Preceding FFA does not alter the Topcon FAF image. Regarding the FAF behaviour, there are differences between the two systems which need to be taken into account when interpreting the images.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This case study deals with a rock face monitoring in urban areas using a Terrestrial Laser Scanner. The pilot study area is an almost vertical, fifty meter high cliff, on top of which the village of Castellfollit de la Roca is located. Rockfall activity is currently causing a retreat of the rock face, which may endanger the houses located at its edge. TLS datasets consist of high density 3-D point clouds acquired from five stations, nine times in a time span of 22 months (from March 2006 to January 2008). The change detection, i.e. rockfalls, was performed through a sequential comparison of datasets. Two types of mass movement were detected in the monitoring period: (a) detachment of single basaltic columns, with magnitudes below 1.5 m3 and (b) detachment of groups of columns, with magnitudes of 1.5 to 150 m3. Furthermore, the historical record revealed (c) the occurrence of slab failures with magnitudes higher than 150 m3. Displacements of a likely slab failure were measured, suggesting an apparent stationary stage. Even failures are clearly episodic, our results, together with the study of the historical record, enabled us to estimate a mean detachment of material from 46 to 91.5 m3 year¿1. The application of TLS considerably improved our understanding of rockfall phenomena in the study area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Selective laser trabeculoplasty (SLT) is a relatively new treatment strategy for the treatment of glaucoma. Its principle is similar to that of argon laser trabeculoplasty (ALT), but may lead to less damage to the trabecular meshwork. METHODS: We assessed the 2-year efficacy of SLT in a noncomparative consecutive case series. Any adult patient either suspected of having glaucoma or with open-angle glaucoma, whose treatment was judged insufficient to reach target intraocular pressure (IOP), could be recruited. IOP and number of glaucoma treatments were recorded over 2 years after the procedure. RESULTS: Our sample consisted of 44 consecutive eyes of 26 patients, aged 69+/-8 years. Eyes were treated initially on the lower 180 degrees . Three of them were retreated after 15 days on the upper 180. Fourteen eyes had ocular hypertension, 17 primary open-angle/normal-tension glaucoma, 11 pseudoexfoliation (PEX) glaucoma, and two pigmentary glaucoma. Thirty-six eyes had previously been treated and continued to be treated with topical anti-glaucoma medication, ten had had prior ALT, nine iridotomy, and 12 filtering surgery. The 2-year-follow up could not be completed for eight eyes because they needed filtering surgery. In the remaining 36 eyes, IOP decreased by a mean of 17.2%, 3.3 mmHg, (19.2+/-4.7 to 15+/-3.6 mmHg) after 2 years (p<0.001). As a secondary outcome, the number of glaucoma treatments decreased from 1.44 to 1.36 drops/patient. Other results according to subgroups of patients are analyzed: the greatest IOP decrease occurred in eyes that had never been treated with anti-glaucoma medication or with PEX glaucoma. SLT was probably valuable in a few eyes after filtering surgery; however, the statistical power of the study was not strong enough to draw a firm conclusion. When expressed in survival curves after 2 years, however, only 48% and 41% of eyes experienced a decrease of more than 3 mmHg or more than 20% of preoperative intraocular pressure, respectively. CONCLUSION: SLT decreases IOP somewhat for at least 2 years without an increase in topical glaucoma treatment. However, it cannot totally replace topical glaucoma treatment. In the future, patient selection should be improved to decrease the cost/effectiveness ratio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Both "early" (< 16 weeks' gestation) and "late" (> 26 weeks' gestation) presentations of twin-twin transfusion syndrome (TTTS) are rare and challenging complications of monochorionic/diamniotic twin pregnancies. Growing evidence suggests that fetoscopic laser therapy for both "early" and "late" TTTS is feasible, safe, and yields similar outcomes to cases treated between 16 and 26 weeks' gestation. We suggest reevaluation of conventional gestational age guidelines for laser therapy for TTTS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peer reviewed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O objetivo deste trabalho foi avaliar a possibilidade de se estimar o diâmetro à altura do peito (DAP) com os dados de altura e de número de árvores derivados do escâner a laser aerotransportado (LiDAR, "light detection and ranging"), e determinar o volume de madeira de talhão de Eucalyptus sp. a partir dessas variáveis. O número total de árvores detectadas foi obtido com uso da filtragem de máxima local. A altura de plantas estimada pelo LiDAR apresentou tendência não significativa à subestimativa. A estimativa do DAP foi coerente com os valores encontrados no inventário florestal; porém, também mostrou tendência à subestimativa, em razão do comportamento observado quanto à altura. A variável número de fustes apresentou valores próximos aos observados nas parcelas do inventário. O LiDAR subestimou o volume total de madeira do talhão em 11,4%, em comparação ao volume posto na fábrica. A tendência de subestimação da altura das árvores (em média, cerca de 5%) impactou a estimativa do volume individual de árvores e, consequentemente, a do volume do talhão. No entanto, é possível gerar equações de regressão que estimam o DAP com boa precisão, a partir de dados de altura de plantas obtidos pelo LiDAR. O modelo parabólico é o que possibilita as melhores estimativas da produção volumétrica dos talhões de eucalipto.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Perinteisten kaarihitsausmenetelmien suhteellisen suuri lämmöntuonti aiheuttaa huomattavia muodonmuutoksia laivan rungon valmistusprosessin alkuvaiheessa. Muodonmuutosten seurauksena rakenteiden mitta- ja muototarkkuus heikkenee, mikä lisää oikaisu- ja sovitustyötä myöhemmissä työvaiheissa. Hitsausmuodonmuutoksia voidaan vähentää siirtymällä käyttämään laser-MAG-hybridihitsausta, jossa lämmöntuonti on merkittävästi pienempi kuin kaarihitsauksessa. Näin kyetään oleellisesti leikkaamaan oikaisu- ja sovitustyöstä syntyviä kustannuksia. Tämän diplomityön tavoitteena oli kehittää tuotantovalmiiksi kuitulaser- ja MAG-hitsauksen yhdistelmäprosessi Aker Yards Oy:n Turun telakalla loppuvuoden 2006 aikana. Hitsauslaitteiston asennus oli valmistunut kesäkuussa 2006, minkä jälkeen aloitettiin luokituslaitoksen hyväksymän koeohjelman hitsaukset. Käyttöönotto suunnitelmaan sisältyvä koehitsausohjelma oli laadittu Det Norske Veritaksen julkaisemaa ohjetta (Guidelines no. 19) mukaillen. Ensimmäiseksi määritettiin hitsauskokeiden avulla prosessille laadun ja tehokkuuden suhteen optimaalinen railogeometria. Seuraavaksi optimoitiin prosessin hitsausparametrit 6 mm:n aineenpaksuudelle hyödyntäen Taguchi-koesuunnittelumenetelmää. Tämän jälkeen optimiparametreilla hitsattiin koekappale väsytyskokeisiin, jotka suoritettiin Teknillisen korkeakoulun laivalaboratoriossa. Väsytyskoetulokset täyttivät luokituslaitoksen vaatimukset. Myös hitsauksen menetelmäkoe suoritettiin hyväksytetysti. Viimeinen koeohjelman mukainen hitsauskoesarja tehtiin prosessiparametrien sallittujen vaihtelurajojen määrittämiseksi. Diplomityön tavoite täyttyi joulukuussa 2006, jolloin 'laivan kansipaneeli hitsattiin ensimmäistä kertaa uudella hitsausprosessilla. Hitsauksen laatu korreloi hyvin menetelmäkokeen tulosten kanssa ¿ hitsit olivat tasalaatuisia ja ne täyttivät B-luokan vaatimukset.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this thesis is to reveal how the laser cutting parameters influence lasercutting of particleboard, HDF and MDF. The literature review introduces the basic principle of CO2 laser, CO2 laser equipment and its usage in cutting of wood-based materials. The experimental part focuses on the discussion and analysis ofthe test data and attempts to draw conclusions on the influence of various parameters, including laser power, focal length of the lens and cutting gas, on the cutting speed and kerf quality. The tested materials include various thicknesses of particleboard, HDF and MDF samples. A TRUMPF TLF2700 HQ laser equipment was used for the experiments. To obtain valid data, the test samples must be completely cut through without any bonding of wood fibre. The maximum cutting speed is linear dependent on the laser power in thecondition that the other parameters are constant. For each thickness of a specific material type, there is a minimum laser power for cutting. Normally, the topand bottom kerf widths increase with the enhancement of laser power. There may be a critical laser power which can generate the minimum cross-sectional kerf width. Lens of larger focal length may achieve higher cutting speed. As the focal length becomes larger, the top kerf width tends to increase while the bottom andcross-sectional kerf widths to the opposite. Of all cutting gases, oxygen can help achieve higher cutting speed. The gas pressure of nitrogen does not seem to have strong influence on the cutting result. Generally, 2 bar air is more preferable for higher cutting speed. For particleboard and MDF samples of larger thickness than 12 mm, 2 bar argon can be used to reach remarkably higher cutting speed than the 5 bar. Generally, the 190.5 mm lens can produce smallest total kerf width. The kerf sides of thicker samples are darker than the thinner ones. The sample darkness tends to be lower as laser power increased. 63.5 mm lens seemed tocause more darkness than other lens. 5 bar cutting gases can produce less dark side kerfs than 2 bar ones. Oxygen normally causes darker kerfs than other gases. No distinct differences were found between nitrogen and argon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High reflectivity and high thermal conductivity, high vapour pressure of alloyingelements as well as low liquid surface tension and low ionisation potential, make laser welding of aluminium and its alloys a demanding task.Problems that occur during welding are mainly process instabilities of the keyhole and the melt pool, increased plasma formation above the melt pool and loss of alloying elements. These problems lead to unwanted metallurgical defects like hot cracks and porosity in the weld bead andother problems concerning the shape and appearance of the weld bead. In order to minimise the defects and improve the weld quality, the process and beam parameters need to be carefully adjusted along with a consideration concerning the use of filler wire for the welding process. In this work the welding of 3,0 mm thick grade 5083 aluminium alloy plates using a 3,0 kW Nd:YAG laser with grade 5183 filler wire addition is investigated. The plates were welded as butt joints with air gap sizes 0,5 mm, 0,7mm and 1,0 mm. The analysis of the weld beads obtained from the weldedsamples showed that the least imperfections were produced with 0,7 mm air gaps at moderate welding speeds. The analysis also covered the calculation of the melting efficiency and the study of the shape of the weld bead. The melting efficiency was on average around 20 % for the melting process of the welded plates. The weld beads showed the characteristic V-shape of a laser weld and retained this shape during the whole series of experiments.