997 resultados para LIQUID NORMAL-ALKANES
Resumo:
OBJECTIVE:To examine the presence of serum antinuclear autoantibodies in a healthy population. METHODS: Serum of 500 normal blood donors between 18 and 60 years of age were tested for the presence of autoantibodies. Antinuclear antibodies were detected by indirect immunofluorescence technique using HEp-2 epithelial cells as the substrate. The presence of dnaN was detected by indirect immunofluorescence technique using Critidia lucillae as the substrate. Anti-SSA (RO), anti-SSB (LA), anti-Sm, and anti-RNP were determined by double radial immunodiffusion. RESULTS: In the evaluation of the presence of serum antibodies, antinuclear antibodies were detected in 22.6% of the sera. The presence of other antibodies was not significant. The majority of the titers were 1:40. CONCLUSION: The presence of autoantibodies is not necessarily pathologic and has to be related to the age group, gender, and clinical condition of the patient.
Resumo:
The work presented in this thesis aims at developing a new separation process based on the application of supported magnetic ionic liquid membranes, SMILMs, using magnetic ionic liquids, MILs. MILs have attracted growing interest due to their ability to change their physicochemical characteristics when exposed to variable magnetic field conditions. The magnetic responsive behavior of MILs is thus expected to contribute for the development of more efficient separation processes, such as supported liquid membranes, where MILs may be used as a selective carrier. Driven by the MILs behavior, these membranes are expected to switch reversibly their permeability and selectivity by in situ and non-invasive adjustment of the conditions (e.g. intensity, direction vector and uniformity) of an external applied magnetic field. The development of these magnetic responsive membrane processes were anticipated by studies, performed along the first stage of this PhD work, aiming at getting a deep knowledge on the influence of magnetic field on MILs properties. The influence of the magnetic field on the molecular dynamics and structural rearrangement of MILs ionic network was assessed through a 1H-NMR technique. Through the 1H-NMR relaxometry analysis it was possible to estimate the self-diffusion profiles of two different model MILs, [Aliquat][FeCl4] and [P66614][FeCl4]. A comparative analysis was established between the behavior of magnetic and non-magnetic ionic liquids, MILs and ILs, to facilitate the perception of the magnetic field impact on MILs properties. In contrast to ILs, MILs show a specific relaxation mechanism, characterized by the magnetic dependence of their self-diffusion coefficients. MILs self-diffusion coefficients increased in the presence of magnetic field whereas ILs self-diffusion was not affected. In order to understand the reasons underlying the magnetic dependence of MILs self-diffusion, studies were performed to investigate the influence of the magnetic field on MILs’ viscosity. It was observed that the MIL´s viscosity decreases with the increase of the magnetic field, explaining the increase of MILs self-diffusion according to the modified Stokes- Einstein equation. Different gas and liquid transport studies were therefore performed aiming to determine the influence of the magnetic behavior of MILs on solute transport through SMILMs. Gas permeation studies were performed using pure CO2 andN2 gas streams and air, using a series of phosphonium cation based MILs, containing different paramagnetic anions. Transport studies were conducted in the presence and absence of magnetic field at a maximum intensity of 1.5T. The results revealed that gas permeability increased in the presence of the magnetic field, however, without affecting the membrane selectivity. The increase of gas permeability through SMILMs was related to the decrease of the MILs viscosity under magnetic field conditions.(...)
Resumo:
RESUMO: Os mais recentes métodos de neuro imagem tal como a Ressonância Magnética (RM) permitiram obter imagens detalhadas do cérebro humano in vivo. Essas imagens revelam, muitas vezes, achados imprevistos face ao padrão normal, com elevada propensão para os indivíduos idosos e franca coexistência com fatores de risco vascular, como característica dum processo de envelhecimento normal. Embora na última década tenham surgido várias publicações sobre este assunto, ele continua ainda pouco explicado. Um pouco por todo o mundo têm emergido os programas de prevenção da doença e promoção da saúde desenvolvidos pela Saúde Pública suportadas sobretudo pelo avanço das tecnologias médicas que resultaram, entre outros impactos, num crescimento da população idosa. Estima-se, em 2030, uma composição demográfica com 20% de indivíduos acima dos 65 anos. Neste contexto, a doença microvascular cerebral é a causa mais frequente de comprometimento cognitivo vascular no idoso sendo as características senescentes na imagem por RM do tipo lesões isquémicas da Substância Branca (Leukoaraiosis) e enfartes lacunares (Status lacunar), atrofia cerebral, gliose e acumulação excessiva de ferro nos núcleos da base. Esta tese, considerando a linha de investigação de que deriva – Ciências da Vida - especialização em Medicina Clinica - Biotecnologia, reúne e reflete sobre três vertentes ligadas à RM e interdependentes em relação a uma problemática comum. A primeira trata da caracterização da Tecnologia por Ressonância Magnética existente em Portugal, a qual inclui uma avaliação exploratória da aplicação da técnica de Difusão Anisotrópica nos estudos cerebrais. As dimensões analíticas estudadas foram a Tecnológica, Sociodemográfica e Económica. Na recolha de dados recorreu-se a várias fontes de informação e a uma metodologia exploratória faseada, validada pela triangulação dos resultados. A sua análise obedeceu a critérios de estratificação e agrupamento segundo as mesmas dimensões analíticas. Otimização da anisotropia fronto-calosa e [RM 1,5T] no idoso normal e com risco cérebro-vascular A segunda descreve o estudo anátomo – radiológico que recaiu sobre parâmetros de quantificação assente na temática do cérebro do idoso em cadáver segundo uma metodologia experimental aplicada às métricas da difusão por RM. Na terceira, e última, é apresentado o estudo técnico - radiológico para avaliação e otimização da imagem ponderada em difusão em estudos clínicos associados ao cérebro do idoso “The Usual Brain Aging” ou Envelhecimento Cerebral Normal, com base metodológica assente nos critérios e indicadores estabelecidos pelo Estudo de Imagem de Roterdão (Rotterdam Scan Study - RSS). Como principais resultados obteve-se que não existem em Portugal estruturas para avaliação dos equipamentos pesados ou Agência de Avaliação das Tecnologias da Saúde para desenvolver o importante papel da produção de estudos comparativos entre os equipamentos disponíveis no mercado, a relação preço-qualidade e a sua afetação às necessidades clínico-epidemiológicas. Constatou-se que a implementação de equipamentos de RM está fortemente assente em critérios económicos carecendo de recomendações e diretivas para o uso racionalizado destas tecnologias. Quanto a dados quantitativos concluímos que a maioria dos equipamentos está instalada em instituições privadas (80,2%); a intensidade de campo magnético mais frequente é [1,5T] com 119 equipamentos; os equipamentos estão instalados maioritariamente nos distritos de Lisboa (55 unidades) e do Porto (39 unidades); o rácio médio de equipamentos por habitante em Portugal é de 1 para 65 195 habitantes; a amplitude de gradientes com maior expressão na amostra é 30-39mT/m; a maioria dos equipamentos foi instalada no intervalo temporal [2009-2012] com 59 equipamentos; apenas 6 instituições desenvolvem investigação clinica e a maioria das bobinas para estudos de crânio são do tipo Array. O estudo de otimização da técnica da difusão revelou, quanto à avaliação dos valoresb, que os mais baixos (b=500 s/mm2 e b=1000 s/mm2), apresentam maior IS e SNR sendo esta uma boa medida referente à qualidade de imagem, no entanto, os valores-b mais elevados (b=2000 s/mm2) apresentam maior CNR e CR, face aos anteriores, o Otimização da anisotropia fronto-calosa e [RM 1,5T] no idoso normal e com risco cérebro-vascular que apesar de proporcionar inferior detalhe anatómico e consequentemente inferior qualidade de imagem, num encéfalo normal, pode auxiliar na interpretação e apresentar vantagens na identificação de lesões microvasculares sempre que persistirem dúvidas em relação ao diagnóstico diferencial de doença microvascular do tipo status lacunar ou Hiperintensidades da Substância Branca. As alterações deste parâmetro são particularmente refletidas nas diferenças da avaliação da qualidade de imagem na região fronto-calos Concluímos da avaliação quantitativa da concentração média de ferro (26Fe) em todas as faixas etárias que os núcleos da base que apresentam maior concentração são, por ordem decrescente: Substância Nigra, Globus Pallidus, Putamen, Tálamo, Núcleo Rubro e Núcleo Caudado; que existe uma predominância na concentração de ferro (26Fe) no hemisfério esquerdo e que os indivíduos do género masculino apresentam mais ferro (26Fe) que os do género feminino nas faixas etárias [30-40[, [40-50[ e [50-60[. Como principal conclusão do estudo da concentração média de ferro em relação à idade destacamos que a concentração média de ferro (26Fe) é superior nos grupos etários superiores, logo aumenta com a idade, sobretudo na Substância Nigra e no Núcleo Lenticular. No estudo técnico-radiológico encontrámos evidências do aumento da difusibilidade da água na substância branca subcortical dos sujeitos idosos comparativamente aos mais jovens. Uma relação idêntica foi avaliada nos tálamos. O aumento relacionado com a idade parece ser predominantemente observado em doentes com mais de 65 anos de idade o que pode refletir alterações estruturais ligeiras associados ao envelhecimento normal. Os resultados indicam que a análise quantitativa das imagens ponderadas em difusão fornece informações, sobre a estrutura do cérebro, as quai s não estão disponíveis apenas por inspeção visual, tanto nas imagens ponderadas em difusão como em outras sequências de aplicação clínica de rotina. Para fazer face às desvantagens dos sistemas de quantificação das HSB os quais são dispendiosos, complexos, requererem tecnologia e formação específicas, recomendamos que a aplicação automatizada GUIAL, desenvolvida ao longo do nosso trabalho é de utilização elementar e prática para que seja introduzida nos sistemas de aquisição de imagem por RM com o fim de integrar o processamento de imagem nos indivíduos portadores de fatores de risco vascular. A avaliação do ADC, nesta amostra, permitiu concluir que a variação desta variável é explicada estatisticamente pela existência da condição clínica de status lacunar em ambos os hemisférios ou por outras palavras, o status lacunar influencia o valor de ADC. Embora uma pequena percentagem da variação do ADC seja explicada pelo género, o ADC nos homens foi superior ao das mulheres o que não nos surpreende, pois são também os homens onde a frequência de doença microvascular se revelou mais expressiva. Os valores do ADC, globalmente, entre os hemisférios cerebrais não mostraram alterações exceto na SB entre os idosos e não idosos. A SB da região frontal mostrou valores diminuídos na anisotropia e isotropia face às restantes áreas anatómicas. Os estudos indicam que na idade avançada existe uma maior predisposição para suscetibilidades de estrutura com status de desconexão. A classificação das HSB foi superior em indivíduos mais velhos e com status lacunar, e em menor quantidade (inferior rating de classificação) nos indivíduos idosos sem status lacunar. As alterações volumétricas foram mais frequentes no homem do que na mulher, presumivelmente devido à associação com a elevada classificação de status lacunar. Um aumento do índice de Evan correspondeu, neste estudo, ao aumento das HSB, à diminuição do volume cerebral total, à expansão ventrículo-sulcal frontal e ao aumento da medida do ângulo caloso. Estes resultados foram agravados pela classificação elevada de status lacunar nos indivíduos que apresentaram indícios de doença de pequenos vasos, com manifesto aumento dos espaços de Virchow-Robin,enfartes lacunares ou HSB. Esses resultados foram mais expressivos no género masculino do que no feminino revelando uma maior vulnerabilidade sobretudo na atrofia frontal nos homens. Por sua vez as dimensões do Corpo Caloso tornaram-se reduzidas devido à compressão dos ventrículos laterais e terceiro ventrículo. Estes indicadores tiveram expressão particularmente nos indivíduos com mais de 65 anos. ---------------------------------------------------------------------------------------------ABSTRACT: The latest neuroimaging methods, such as Magnetic Resonance Imaging (MRI), have enabled detailed images of in vivo human brain. These images reveal often unexpected findings related to the normal pattern, with high predisposition for the elderly people with forthright coexistence with vascular risk factors such as characteristics of a normal aging process. Although it has been, in the last decade, several publications on this subject, it is still little explained. All over the world have emerged disease prevention programs and health promotion developed by the Public Health sector, supported mainly by the advancement of medical technologies that have resulted, among other impacts, in a growing of the elderly population. It is estimated, in 2030, a demographic composition with 20% o people over 65 years. In this context, microvascular disease is the most common cause of cognitive vascular impairment in the elderly and senescent characteristics in the MRI trough ischemic lesions of the white matter (Leukoaraiosis) and lacunar infarcts (lacunar status), cerebral atrophy, gliosis and iron accumulation in the basal ganglia in excess.This thesis, considering the research line that stems - Life Sciences - specialization in Clinical Medicine, Biotechnology, gathers and reflects on three aspects linked to MR, interdependent and related to a common problem. The first deals with the Magnetic Resonance Technology characterization in Portugal, which includes an exploratory evaluation of the implementation of Anisotropic Diffusion technique in brain studies. The analytical dimensions studied were the Technologic, Socio-demographic and Economics. Collecting data was supported by different sources of information and was applied an exploratory methodology whose results were validated by triangulation. The research method was grouped and stratified criteria under the same analytical dimensions. The second describes the anatomical study - which was focused on radiological measurement parameters, based on the brain’s specimen under an experimental methodology applied to MRI diffusion metrics. Radiological evaluation and optimization of the weighted image diffusion in clinical studies were associated with the brain of the elderly "The Usual Brain Aging" with methodological basis based on established criteria and indicators by Rotterdam Scan Study (RSS). The main results obtained reveal the inexistence frameworks in Portugal for evaluation of equipments or Agency of Health Technology to produce studies comparing the equipment available on the market, the value for money and its allocation to clinical and epidemiological needs. It was found that the implementation of MRI equipment is strongly based on economic criteria lacking recommendations and guidelines for the rationalized use of these technologies. As the quantitative data we conclude that most of the scanners are located in private clinical institutions (80,2%); the most frequent magnetic field intensity is [1.5T] with 119 scanners; the scanners are mainly installed in Lisbon (55 units) and Porto (39 units) districts; the average ratio of equipment per capita in Portugal is 1 to 65 195 people; the gradient power with higher expression in the sample is 30-39mT / m;most of the scanners were installed in the years range [2009-2012 years] with 59 equipment; only 6 clinical placements develop clinical research and the most coils for brain studies are of Array type. The optimization study of diffusion technique revealed, as the assessment of the bvalues, the lower (b = 500 s / mm2 and b = 1000 s / mm 2), promotes an increase in the SI and SNR being this measure related to a higher image quality, however the highest b values (b = 2000 s / mm 2) have a higher CNR (Contrast to Noise-Ratio) and CR (Contrast Ratio), compared to the previous ones. This may provide less anatomical details and, thus, ower image quality, of a normal brain, however can help the interpretation and have advantages in identifying microvascular injuries when doubts persist regarding the differential diagnosis of microvascular disease of lacunar or WMH (White Matter Hyperintensities) status type. Changes on this parameter are Otimização da anisotropia fronto-calosa e [RM 1,5T] no idoso normal e com risco cérebro-vascular particularly reflected in the differences of image quality evaluation in the frontocallosum anatomical area. We conclude from the quantitative assessment of the average concentration of iron (26Fe), in all age groups to the basal ganglia, that the higher concentrations are, in descending order: Nigral Substantia, Globus pallidus, Putamen, Thalamus, Rubio nucleus and Caudate nucleus; that there is a predominance in the concentration of iron (26Fe) in the left hemisphere and that male gender show higher iron (26Fe) level tha females, in the age groups [30-40 [[40-50 [and [50- 60 [. Regarding a main conclusion of the mean concentration study of iron, in terms of age we point out that the average concentration of iron (26Fe) is higher among older groups and increases with age, especially in Nigral Substantia and Lenticular Nucleus. On the technical and radiological study we found evidence of an increased in water /diffusivity in the ubcortical white matter of the elderly compared with younger subjects. A similar relationship was assessed in the Thalamus. The increase agerelated seems to be predominantly observed in patients over 65 years which may reflect minor structural changes associated with normal aging. The results indicate that quantitative analysis of diffusion weighted imaging can provide information about the structure of the brain which is not reached only by visual inspection or standard sequences applied in clinical routine. To address the disadvantages the systems of quantification of WMH which the authors state that are costly, complex, require specific technology and training, we recommend that the automated application GUIAL, developed over our work is basic and practical to use and to be introduced in MR image systems acquisition in order to integrate image processing in patients with vascular risk factors. The evaluation of the ADC showed that its variation is statistically explained by the existence of the medical condition of lacunar status, in both hemispheres, or in other words, the lacunar status influences the ADC value. Although a small percentage of the ADC variation is explained by gender, the ADC in men was higher than women which Otimização da anisotropia fronto-calosa e [RM 1,5T] no idoso normal e com risco cérebro-vascular do not surprise us, since they are also men where the frequency of microvasculardisease has proved more significant. The values of ADC, overall, between the cerebral hemispheres showed no changes but were different in WM among the elderly and non-elderly subjects.The WM's forehead showed decreased values in anisotropy and isotropy face the other anatomical areas. The studies indicate that in old age there is a greater tendency to higher susceptibility to disconnection- status framework. The classification of WMH was higher in elderly people and lacunar status, and fewer (lower classification rating) in the elderly without lacunar status. volumetric changes were more frequent in men than in women, most probably because of its association with high lacunar status rating. An increase of Evan index corresponded, in this study, to an increase in WMH, to a decreased of total brain volume, to a ventricle sulcal frontal and callous angle expansion. These results were wound up by high ranking of lacunar status in subjects who had small vessel disease, clear increase in spaces of Virchow-Robin, lacunar infarctions or WMH. These results were more significant in males than in females revealing vulnerability particularly in the frontal atrophy in men. In turn the size of Corpus Callosum because reduced due to the compression of the lateral and third ventricles. These indicators had expression particularly in individuals over 65 years.
Resumo:
Due to the increasing need of low voltage actuators, independent from electrochemical processes, electroactive actuators based on poly(vinylidene fluoride) composites with 10, 25 and 40 % of 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide, [C2mim] [NTf2], ionic liquid are prepared by solvent casting and melting. We show that the charge structure of [C2mim] [NTf2] induces the complete piezoelectric -phase crystallization of the PVDF within the composite and decreases its crystallinity fraction significantly. [C2mim] [NTf2] also works as a plasticizer of PVDF, reducing the elastic modulus down to 12 % of the initial value. Moreover, the composites show significant displacement and bending under applied voltages of 2, 5 and 10 Vpp. The displacement and bending of the composite membranes are also evaluated as a function of [C2mim] [NTf2] content and sample thickness. Increasing amounts of ionic liquid result in larger deformations independently of the applied voltage.
Resumo:
Poly(vinylidene fluoride), PVDF, has been blended with different ionic liquids (IL) in order to evaluate the effect of the different IL anions and cations on the electroative -phase, thermal, mechanical and electrical properties of the polymer blend. [C2MIM][Cl], [C6MIM][Cl], [C10MIM][Cl], [C2MIM][NTf2], [C6MIM][NTf2], [C10MIM][NTf2] have been selected and were introduced in the polymer at a weight percentage of 40 wt%. It was found that the incorporation of ILs into the PVDF matrix leads to an increase of the -phase content due to the strong electrostatic interactions between the dipolar moments of PVDF and the ILs. Further, the incorporation of ILs into PVDF strongly decreases the elastic modulus and increases the electrical conductivity of the blend with respect to the pure polymer matrix, all these effects being accompanied by a modification of the crystallization kinetics, as indicated by the modified spherulitic microstructure. Thus, novel PVDF/IL blends films with high transparency, excellent antistatic properties, and highly polar crystal form fraction were successfully achieved.
Resumo:
The effect of different anions within the ionic liquid in the characteristics of solid polymer electrolytes (SPEs) based on P(VDF-TrFE) has been investigated. 1-ethyl-3-methylimidazolium acetate, [C2mim][OAc], 1-ethyl-3-methylimidazolium triflate, [C2mim][(CF3SO3)3], 1-ethyl-3-methylimidazolium lactate, [C2mim][Lactate], 1-ethyl-3-methylimidazolium thiocyanate, [C2mim][SNC] and 1-ethyl-3-methylimidazolium hydrogen sulphate [C2mim][HSO4] have been used in SPE prepared by thermally induced phase separation (TIPS). The polymer phase, thermal and electrochemical properties of the SPE have been determined. The thermal and electrical properties of the SPEs strongly depend on the selected IL, as determined by their different interactions with the polymer matrix. The room temperature ionic conductivity increases in the following way for the different anions: [SNC] > [CF3SO3)3] > [HSO4] > [Lactate] > [OAc], which is mainly dependent on the viscosity of the ionic liquid.
Resumo:
Comunicação oral, não escrita, não submetida a publicação.
Resumo:
The tocopherol content of Brazil nut oil from different Amazon regions (Manicoré-AM, Rio Preto da Eva-AM, São João da Baliza-RR, Caroebe-RR, Belém-PA, and Xapurí-AC) was investigated by normal-phase high-performance liquid chromatography. For all authentic oils, two isomers: α- and γ-tocopherols were observed (37.92-74.48 µg g-1, 106.88-171.80 µg g-1, respectively), and their levels were relatively constant among the oils having these geographic origins, which would enable to distinguish Brazil nut oil from other plant oils for authentication purposes. Commercial Brazil nut oils were also evaluated, and some of these oils demonstrated a tocopherol content that was very different from that of the authentic oils. Therefore, we suggest that the tocopherol profile of Brazil nut oil can be useful chemical marker for quality control and authentication.
Resumo:
BACKGROUND: Fine-needle aspiration cytology (FNAC) of serous membrane effusions may fulfil a challenging role in the diagnostic analysis of both primary and metastatic disease. From this perspective, liquid-based cytology (LBC) represents a feasible and reliable method for empowering the performance of ancillary techniques (ie, immunocytochemistry and molecular testing) with high diagnostic accuracy. METHODS: In total, 3171 LBC pleural and pericardic effusions were appraised between January 2000 and December 2013. They were classified as negative for malignancy (NM), suspicious for malignancy (SM), or positive for malignancy (PM). RESULTS: The cytologic diagnoses included 2721 NM effusions (2505 pleural and 216 pericardic), 104 SM effusions (93 pleural and 11 pericardic), and 346 PM effusions (321 pleural and 25 pericardic). The malignant pleural series included 76 unknown malignancies (36 SM and 40 PM effusions), 174 metastatic lesions (85 SM and 89 PM effusions), 14 lymphomas (3 SM and 11 PM effusions), 16 mesotheliomas (5 SM and 11 SM effusions), and 3 myelomas (all SM effusions). The malignant pericardic category included 20 unknown malignancies (5 SM and 15 PM effusions), 15 metastatic lesions (1 SM and 14 PM effusions), and 1 lymphoma (1 PM effusion). There were 411 conclusive immunocytochemical analyses and 47 molecular analyses, and the authors documented 88% sensitivity, 100% specificity, 98% diagnostic accuracy, 98% negative predictive value, and 100% positive predictive value for FNAC. CONCLUSIONS: FNAC represents a primary diagnostic tool for effusions and a reliable approach with which to determine the correct follow-up. Furthermore, LBC is useful for ancillary techniques, such as immunocytochemistry and molecular analysis, with feasible diagnostic and predictive utility.
Resumo:
The sol-gel method was employed in the synthesis of di-urethane cross-linked poly( caprolactone) (PCL(530)/siloxane biohybrid ormolytes incorporating either a mixture of lithium triflate (LiCF3SO3) and the ionic liquid (IL) 1-ethyl-3-methyl imidazolium tetrafluoroborate ([Emim]BF4), or solely with [Emim]BF4 or LiCF3SO3. The ormolyte doped with [Emim]BF4 is thermally more stable and exhibits higher ionic conductivity (4 x 10-4 and 2 x 10-3 S cm-1 at 36 and 98 ºC, respectively) than those containing the LiCF3SO3/[Emim]BF4 mixture or just LiCF3SO3. The three ormolytes were employed in the production of glass/ITO/ormolyte/WO3/ITO/glass electrochromic devices (ECDs) designated as ECD@Y with Y = Li-[Emim]BF4, [Emim]BF4 and Li. The three ECDs displayed fast switching speed (ca. 30 s). ECD@Li-[Emim]BF4 exhibited an electrochromic contrast of 18.4 % and an optical density change of 0.11 in the visible region, the coloration efficiency attained at 555 nm was 159 and 80.2 cm-2 C-1 in the “on” and “off” states, respectively, and the open circuit memory was 48 hours. In the “on” state the CIE 1931 color space coordinates were x = 0.29 and y = 0.30, corresponding to blue color.
Resumo:
New polymer electrolytes (PEs) based on chitosan and three ionic liquid (IL) families ([C2mim][CnSO3], [C2mim][CnSO4] and [C2mim][diCnPO4]) were synthesized by the solvent casting method. The effect of the length of the alkyl chain of the IL anion on the thermal, morphological and electrochemical properties of the PEs was studied. The solid polymer electrolytes (SPE) membranes were analyzed by differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), X-ray diffraction (XRD), scanning electron microscopy (SEM), energy dispersive X-ray (EDX), polarized optical microscopy (POM), atomic force microscopy (AFM), complex impedance spectroscopy (ionic conductivity) and cyclic voltammetry (CV). The obtained results evidenced an influence of the alkyl chain length of the IL anion on the temperature of degradation, birefringence, surface roughness and ionic conductivity of the membranes. The DSC, XRD and CV results showed independency from the length of the IL-anion-alkyl chain. The PEs displayed an predominantly amorphous morphology, a minimum temperature of degradation of 135 °C, a room temperature (T = 25 °C) ionic conductivity of 7.78 × 10−4 S cm−1 and a wide electrochemical window of ∼ 4.0 V.
Resumo:
Biopolymer-based materials have been of particular interest and they are alternatives to synthetic polymers based on the decreasing oil resources. The polymer electrolytes were doped with choline-based IL N,N,Ntrimethyl- N-(2-hydroxyethyl)ammonium bis(trifluoromethylsulfonyl)imide ([N1 1 1 2(OH)][NTf2]), or Er (CF3SO3)3 or both. The polymer electrolytes were employed in the production of glass/ITO/WO3/electrolyte/ CeO2–TiO2/ITO/glass electrochromic devices (ECDs). The lowest onset temperature for the degradation of all the SPEs is at ~130 °C for the Gellan Er (CF3SO3)3 (10:1) this temperature range of stability is wide enough for a material to be applied as an electrolyte/separator component in electrochemical devices. The three ECDs displayed fast switching speed (ca. 15 s). Gellan [N1 1 1 2(OH)][NTf2] Er (CF3SO3)3 (5:1:10) exhibited an electrochromic contrast of 4.2% in the visible region, the coloration efficiency attained at 555 nm was 3.5 and 0.90 cm-2 C-1 in the “colored” and “bleached” states, respectively, and the open circuit memorywas 48 h. Preliminary tests performed with a prototype electrochromic device (ECD) incorporating WO3 as cathodic electrochromic layer, are extremely encouraging.
Resumo:
It is well known that color coding facilitates search and iden- tification in real-life tasks. The aim of this work was to compare reac- tion times for normal color and dichromatic observers in a visual search experiment. A unique distracter color was used to avoid abnormal color vision vulnerability to background complexity. Reaction times for nor- mal color observers and dichromats were estimated for 2◦ central vision at 48 directions around a white point in CIE L∗a∗b∗ color space for systematic examination on the mechanisms of dichromatic color percep- tion. The results show that mean search times for dichromats were twice larger compared to the normal color observers and for all directions. The difference between the copunctual confusion lines and the confusion direction measure experimentally was 5.5◦ for protanopes and 7.5◦ for deuteranopes.
Resumo:
OBJECTIVE The aim of this study was to compare the performance of the current conventional Pap smear with liquid-based cytology (LBC) preparations. STUDY DESIGN Women routinely undergoing their cytopathological and histopathological examinations at Fundação Oncocentro de São Paulo (FOSP) were recruited for LBC. Conventional smears were analyzed from women from other areas of the State of São Paulo with similar sociodemographic characteristics. RESULTS A total of 218,594 cases were analyzed, consisting of 206,999 conventional smears and 11,595 LBC. Among the conventional smears, 3.0% were of unsatisfactory preparation; conversely, unsatisfactory LBC preparations accounted for 0.3%. The ASC-H (atypical squamous cells - cannot exclude high-grade squamous intraepithelial lesion) frequency did not demonstrate any differences between the two methods. In contrast, the incidence of ASC-US (atypical squamous cells of undetermined significance) was almost twice as frequent between LBC and conventional smears, at 2.9 versus 1.6%, respectively. An equal percentage of high-grade squamous intraepithelial lesions were observed for the two methods, but not for low-grade squamous intraepithelial lesions, which were more significantly observed in LBC preparations than in conventional smears (2.2 vs. 0.7%). The index of positivity was importantly enhanced from 3.0% (conventional smears) to 5.7% (LBC). CONCLUSIONS LBC performed better than conventional smears, and we are truly confident that LBC can improve public health strategies aimed at reducing cervical lesions through prevention programs.
Resumo:
Congenital diaphragmatic hernia (CDH) is characterised by a spectrum of lung hypoplasia and consequent pulmonary hypertension, leading to high morbidity and mortality rates. Moreover, CDH has been associated with an increase in the levels of pulmonary neuroendocrine factors, such as bombesin and ghrelin, and a decrease in the action of retinoic acid (RA). The present study aimed to elucidate the interaction between neuroendocrine factors and RA. In vitro analyses were performed on Sprague-Dawley rat embryos. Normal lung explants were treated with bombesin, ghrelin, a bombesin antagonist, a ghrelin antagonist, dimethylsulfoxide (DMSO), RA dissolved in DMSO, bombesin plus RA and ghrelin plus RA. Hypoplastic lung explants (nitrofen model) were cultured with bombesin, ghrelin, bombesin antagonist or ghrelin antagonist. The lung explants were analysed morphometrically, and retinoic acid receptor (RAR) α, β and γ expression levels were assessed via Western blotting. Immunohistochemistry analysis of RAR was performed in normal and hypoplastic lungs 17.5 days post-conception (dpc). Compared with the controls, hypoplastic lungs exhibited significantly higher RARα/γ expression levels. Furthermore considering hypoplastic lungs, bombesin and ghrelin antagonists decreased RARα/γ expression. Normal lung explants (13.5 dpc) treated with RA, bombesin plus RA, ghrelin plus RA, bombesin or ghrelin exhibited increased lung growth. Moreover, bombesin and ghrelin increased RARα/γ expression levels, whereas the bombesin and ghrelin antagonists decreased RARα/γ expression. This study demonstrates for the first time that neuroendocrine factors function as lung growth regulators, sensitising the lung to the action of RA through up-regulation of RARα and RARγ.