987 resultados para LASER PULSE REPETITION RATE
Resumo:
This study determined the effects of gallium-aluminum-arsenide laser (GaAlAs), gallium-arsenide laser (GaAs) and Dersani® healing ointment on skin wounds in Wistar rats. The parameters analyzed were: type I and III collagen fiber concentrations as well as the rate of wound closure. Five wounds, 12 mm in diameter, were made on the animals’ backs. The depth of the surgical incision was controlled by removing the epithelial tissue until the dorsal muscular fascia was exposed. The animals were anesthetized with ketamine and xylazine via intraperitoneal injection. The rats were randomly divided into five groups of 6 animals each, according to the treatment received. Group 1 (L4): GaAs laser (4 J/cm²); group 2 (L30): GaAlAs laser (30 J/cm²); group 3 (L60): GaAlAs laser (60 J/cm²); group 4 (D): Dersani® ointment; group 5 (control): 0.9% saline. The applications were made daily over a period of 20 days. Tissue fragments were stained with picrosirius to distinguish type I collagen from type III collagen. The collagen fibers were photo-documented and analyzed using the Quantum software based on the primary color spectrum (red, yellow and blue). Significant results for wound closing rate were obtained for group 1 (L4), 7.37 mm/day. The highest concentration of type III collagen fibers was observed in group 2 (L30; 37.80 ± 7.10%), which differed from control (29.86 ± 5.15%) on the 20th day of treatment. The type I collagen fibers of group 1 (L4; 2.67 ± 2.23%) and group 2 (L30; 2.87 ± 2.40%) differed significantly from control (1.77 ± 2.97%) on the 20th day of the experiment.
Resumo:
Marfan syndrome (MS) is a dominant autosomal disease caused by mutations in chromosome 15, the locus controlling fibrillin 1 synthesis, and may exhibit skeletal, ocular, cardiovascular, and other manifestations. Pulse wave velocity (PWV) is used to measure arterial elasticity and stiffness and is related to the elastic properties of the vascular wall. Since the practice of exercise is limited in MS patients, it was of interest to analyze the acute effect of submaximal exercise on aortic distensibility using PWV and other hemodynamic variables in patients with MS with either mild or no aortic dilatation. PWV and physiological variables were evaluated before and after submaximal exercise in 33 patients with MS and 18 controls. PWV was 8.51 ± 0.58 at rest and 9.10 ± 0.63 m/s at the end of exercise (P = 0.002) in the group with MS and 8.07 ± 0.35 and 8.98 ± 0.56 m/s in the control group, respectively (P = 0.004). Comparative group analysis regarding PWV at rest and at the end of exercise revealed no statistically significant differences. The same was true for the group that used β-blockers and the one that did not. The final heart rate was 10% higher in the control group than in the MS group (P = 0.01). Final systolic arterial pressure was higher in the control group (P = 0.02). PWV in MS patients with mild or no aortic dilatation did not differ from the control group after submaximal effort.
Resumo:
During cardiopulmonary exercise testing (CPET), stroke volume can be indirectly assessed by O2 pulse profile. However, for a valid interpretation, the stability of this variable over time should be known. The objective was to analyze the stability of the O2 pulse curve relative to body mass in elite athletes. VO2, heart rate (HR), and relative O2 pulse were compared at every 10% of the running time in two maximal CPETs, from 2005 to 2010, of 49 soccer players. Maximal values of VO2 (63.4 ± 0.9 vs 63.5 ± 0.9 mL O2•kg-1•min-1), HR (190 ± 1 vs188 ± 1 bpm) and relative O2 pulse (32.9 ± 0.6 vs 32.6 ± 0.6 mL O2•beat-1•kg-1) were similar for the two CPETs (P > 0.05), while the final treadmill velocity increased from 18.5 ± 0.9 to 18.9 ± 1.0 km/h (P < 0.01). Relative O2 pulse increased linearly and similarly in both evaluations (r² = 0.64 and 0.63) up to 90% of the running time. Between 90 and 100% of the running time, the values were less stable, with up to 50% of the players showing a tendency to a plateau in the relative O2 pulse. In young healthy men in good to excellent aerobic condition, the morphology of the relative O2 pulse curve is consistent up to close to the peak effort for a CPET repeated within a 1-year period. No increase in relative O2pulse at peak effort could represent a physiologic stroke volume limitation in these athletes.
Resumo:
The present study was conducted to obtain reference values for brachial-ankle pulse wave velocity (baPWV) and to evaluate influencing factors of baPWV according to gender. Using automatic devices, baPWV was measured simultaneously in 2095 subjects. A total of 647 healthy subjects, none of whom presented atherosclerotic risk factors, were analyzed in the present study. Two different statistical methods were used to obtain reference values for baPWV according to subject gender and age. The association between baPWV value and gender, as well as other features, were analyzed. For male subjects, multiple stepwise analysis showed that age, systolic blood pressure (SBP), heart rate (HR), and plasma levels of triglycerides (TG) were independent predictors of baPWV. For female subjects, age, SBP, HR, and plasma levels of uric acid (UA) were independent predictors of baPWV. In male subjects, the upper limits of baPWV values were 1497.43/1425.00, 1518.67/1513.25, 1715.97/1726.50, 1925.20/1971.90, and 2310.18/2115.00 cm/s, obtained using two different statistical methods for the age ranges of 30-39, 40-49, 50-59, 60-69, and 70 and older, respectively. For females, the upper limits of baPWV values were 1426.70/1411.13, 1559.15/1498.95, 1733.50/1739.00, 1958.63/1973.78, and 2720.80/2577.00 cm/s for the age ranges of 30-39, 40-49, 50-59, 60-69, and 70 and older, respectively. Aging is the most important influencing factor for baPWV value and its effect is more prominent in females. The reference values of baPWV according to age and gender may be useful for the clinical diagnosis and preventive therapy of cardiovascular diseases.
Resumo:
This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m² mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.
Resumo:
Laser cutting implementation possibilities into paper making machine was studied as the main objective of the work. Laser cutting technology application was considered as a replacement tool for conventional cutting methods used in paper making machines for longitudinal cutting such as edge trimming at different paper making process and tambour roll slitting. Laser cutting of paper was tested in 70’s for the first time. Since then, laser cutting and processing has been applied for paper materials with different level of success in industry. Laser cutting can be employed for longitudinal cutting of paper web in machine direction. The most common conventional cutting methods include water jet cutting and rotating slitting blades applied in paper making machines. Cutting with CO2 laser fulfils basic requirements for cutting quality, applicability to material and cutting speeds in all locations where longitudinal cutting is needed. Literature review provided description of advantages, disadvantages and challenges of laser technology when it was applied for cutting of paper material with particular attention to cutting of moving paper web. Based on studied laser cutting capabilities and problem definition of conventional cutting technologies, preliminary selection of the most promising application area was carried out. Laser cutting (trimming) of paper web edges in wet end was estimated to be the most promising area where it can be implemented. This assumption was made on the basis of rate of web breaks occurrence. It was found that up to 64 % of total number of web breaks occurred in wet end, particularly in location of so called open draws where paper web was transferred unsupported by wire or felt. Distribution of web breaks in machine cross direction revealed that defects of paper web edge was the main reason of tearing initiation and consequent web break. The assumption was made that laser cutting was capable of improvement of laser cut edge tensile strength due to high cutting quality and sealing effect of the edge after laser cutting. Studies of laser ablation of cellulose supported this claim. Linear energy needed for cutting was calculated with regard to paper web properties in intended laser cutting location. Calculated linear cutting energy was verified with series of laser cutting. Practically obtained laser energy needed for cutting deviated from calculated values. This could be explained by difference in heat transfer via radiation in laser cutting and different absorption characteristics of dry and moist paper material. Laser cut samples (both dry and moist (dry matter content about 25-40%)) were tested for strength properties. It was shown that tensile strength and strain break of laser cut samples are similar to corresponding values of non-laser cut samples. Chosen method, however, did not address tensile strength of laser cut edge in particular. Thus, the assumption of improving strength properties with laser cutting was not fully proved. Laser cutting effect on possible pollution of mill broke (recycling of trimmed edge) was carried out. Laser cut samples (both dry and moist) were tested on the content of dirt particles. The tests revealed that accumulation of dust particles on the surface of moist samples can take place. This has to be taken into account to prevent contamination of pulp suspension when trim waste is recycled. Material loss due to evaporation during laser cutting and amount of solid residues after cutting were evaluated. Edge trimming with laser would result in 0.25 kg/h of solid residues and 2.5 kg/h of lost material due to evaporation. Schemes of laser cutting implementation and needed laser equipment were discussed. Generally, laser cutting system would require two laser sources (one laser source for each cutting zone), set of beam transfer and focusing optics and cutting heads. In order to increase reliability of system, it was suggested that each laser source would have double capacity. That would allow to perform cutting employing one laser source working at full capacity for both cutting zones. Laser technology is in required level at the moment and do not require additional development. Moreover, capacity of speed increase is high due to availability high power laser sources what can support the tendency of speed increase of paper making machines. Laser cutting system would require special roll to maintain cutting. The scheme of such roll was proposed as well as roll integration into paper making machine. Laser cutting can be done in location of central roll in press section, before so-called open draw where many web breaks occur, where it has potential to improve runability of a paper making machine. Economic performance of laser cutting was done as comparison of laser cutting system and water jet cutting working in the same conditions. It was revealed that laser cutting would still be about two times more expensive compared to water jet cutting. This is mainly due to high investment cost of laser equipment and poor energy efficiency of CO2 lasers. Another factor is that laser cutting causes material loss due to evaporation whereas water jet cutting almost does not cause material loss. Despite difficulties of laser cutting implementation in paper making machine, its implementation can be beneficial. The crucial role in that is possibility to improve cut edge strength properties and consequently reduce number of web breaks. Capacity of laser cutting to maintain cutting speeds which exceed current speeds of paper making machines what is another argument to consider laser cutting technology in design of new high speed paper making machines.
Resumo:
Faculté de Pharmacie
Resumo:
In vivo, la pression artérielle au niveau des artères cérébrales est pulsée, alors que ex vivo, l’étude de la fonction cérébrovasculaire est majoritairement mesurée en pression statique. L’impact de la pression pulsée sur la régulation du tonus myogénique et sur la fonction endothéliale cérébrale est inconnu. Nous avons posé l’hypothèse selon laquelle en présence d'une pression pulsée physiologique, la dilatation dépendante de l’endothélium induite par le flux et le tonus myogénique seraient optimisés. L’objectif de notre étude est d’étudier ex vivo l’impact de la pression pulsée sur le tonus myogénique et la dilatation induite par le flux dans les artères cérébrales de souris. Nous avons utilisé un artériographe pressurisé couplé à un système générant une onde pulsée de fréquence et d’amplitude réglables. Les artères cérébrales moyennes (≈160 μm de diamètre) ont été isolées de souris C57BL6 âgées de 3 mois et pressurisées à 60 mm Hg, en pression statique ou en pression pulsée. En pression statique, le tonus myogénique est faible mais est potentialisé par le L-NNA (un inhibiteur de la eNOS) et la PEG-catalase (qui dégrade le H2O2), suggérant une influence des produits dilatateurs dérivés de la eNOS sur le tonus myogénique. En présence de pression pulsée (pulse de 30 mm Hg, pression moyenne de 60 mm Hg, 550 bpm), le tonus myogénique est significativement augmenté, indépendamment du L-NNA et de la PEG-catalase, suggérant que la pression pulsée lève l’impact de la eNOS. En pression statique ou pulsée, les artères pré-contractées se dilatent de façon similaire jusqu’à une force de cisaillement de 15 dyn/cm2. Cette dilatation, dépendante de l’endothélium et de la eNOS, est augmentée en condition pulsée à une force de cisaillement de 20 dyn/cm2. En présence de PEG-catalase, la dilatation induite par le flux est diminuée en pression statique mais pas en pression pulsée, suggérant que la pression statique, mais pas la pression pulsée, favorise la production de O2 -/H2O2. En effet, la dilatation induite par le flux est associée à une production de O2 -/H2O2 par la eNOS, mesurable en pression statique, alors que la dilatation induite par le flux en pression pulsée est associée à la production de NO. Les différences de sensibilité à la dilatation induite par le flux ont été abolies après inhibition de Nox2, en condition statique ou pulsée. La pression pulsée physiologique régule donc l’activité de la eNOS cérébrale, en augmentant le tonus myogénique et, en présence de flux, permet la relâche de NO via la eNOS.
Resumo:
Plusieurs décennies de recherche ont permis de mieux comprendre les effets de l’athérosclérose sur le système cardiovasculaire, d’améliorer la prévention et de développer des traitements efficaces. Les effets de l’athéroslérose sur le cerveau demeurent toutefois mal compris même si le lien entre le fonctionnement cognitif et la santé du système vasculaire est maintenant bien établi. La venue de nouvelles méthodes d’imagerie telle la microscopie laser à 2-photons (TPLM) permet d’étudier l’impact de certaines maladies sur la microvasculature cérébrale en mesurant le flux sanguin dans des vaisseaux uniques situés dans des régions cérébrales millimétriques sous la surface. Les résultats des études in vitro peuvent dorénavant être corrélés à ceux obtenus in vivo. En premier lieu, ce mémoire revoit la théorie ayant permis le développement de la TPLM qui permet de prendre des mesures hémodynamiques in vivo dans des vaisseaux de très petits calibres tels des capillaires cérébraux de souris. Par la suite, son utilisation est décrite chez des souris anesthésiées afin de comparer les mesures d’hémodynamie cérébrale tels la vitesse des globules rouges, le flux de globules rouges, le flux sanguin cérébral, l’hématocrite sanguin et le diamètre des vaisseaux. Finalement, nous avons comparé les données hémodynamiques entre des souris de 3 mois normales (WT ; n=6) et des souris atteintes d’athérosclérose précoce (ATX ; n=6). Les résultats obtenus sur un nombre total de 209 capillaires (103 pour les souris WT et 106 pour les souris ATX) démontrent que les souris ATX possèdent une vitesse des globules rouges (+40%) plus grande, un flux de globule rouge plus grand (+12%) et un flux capillaire plus élevé (+14%) sans démontrer pour aucun de ces paramètres, une différence statistiquement significative. L’hématocrite moyen (35±4% vs 33±2% ; p=0.71) et le diamètre moyen des vaisseaux (4.88±0.22μm vs 4.86±0.20μm ; p=0.23) étaient également comparables. La vitesse des globules rouges a démontré une faible corrélation avec le diamètre des vaisseaux (r=0.39) et avec le flux de globules rouges/seconde (r=0.59). En conclusion, les travaux menés dans le cadre de ce mémoire de maîtrise permettent d'envisager, grâce aux nouvelles méthodes d’imagerie cérébrale telle la TPLM, une meilleure compréhension des mécanismes hémodynamiques sous-jacents à la microcirculation cérébrale. L’effet d’une pression pulsée augmentée, tel que proposée dans l’athérosclérose reste cependant à démontrer avec cette méthode d’imagerie.
Resumo:
This thesis is entitled “OPTICAL EMISSION DIAGNOSTICS OF LASER PRODUCED PLASMA FROM GRAPHITE AND YBa2Cu3O7. The work presented in this thesis covers the experimental results on the plasma produced with moderately high power laser with irradiance range in between 10 GW cm 2 to 100 GW cm -2. The characterization of laser produced plasma from solid targets viz. graphite and high temperature superconducting material like YBa2Cu3O7 have been carried out. The fundamental frequency from a Q - switched Nd: YAG laser with 9 ns pulse duration is used for the present studies. Various optical emission emission diagnostic techniques were employed for the the characterization of the LPP which include emission spectroscopy, time resolved studies, line broadening method etc. In order to understand the physical nature of the LPP like recombination, collisional excitation and the laser interaction with plasma, the time resolved studies offer the most logical approach
Resumo:
We present a compact solid-state laser based on leaky mode propagation from a dye-doped polymer free-standing film waveguide. The edge emitted spectrum clearly indicated the existence of periodic resonant modes. The reflections from the lateral faces of the free-standing film provided the optical feedback thus giving rise to a Fabry–Perot like optical cavity. This together with the guidance through the gain medium gave rise to intense narrow emission lines. For a pump energy of 1.82 mJ/pulse, an intense line with FWHM ∼0.4 nmwas observed at 576.5 nm.
Resumo:
We present a compact solid-state laser based on leaky mode propagation from a dye-doped polymer free-standing film waveguide. The edge emitted spectrum clearly indicated the existence of periodic resonant modes. The reflections from the lateral faces of the free-standing film provided the optical feedback thus giving rise to a Fabry–Perot like optical cavity. This together with the guidance through the gain medium gave rise to intense narrow emission lines. For a pump energy of 1.82 mJ/pulse, an intense line with FWHM ∼0.4 nmwas observed at 576.5 nm.
Resumo:
We present a compact solid-state laser based on leaky mode propagation from a dye-doped polymer free-standing film waveguide. The edge emitted spectrum clearly indicated the existence of periodic resonant modes. The reflections from the lateral faces of the free-standing film provided the optical feedback thus giving rise to a Fabry–Perot like optical cavity. This together with the guidance through the gain medium gave rise to intense narrow emission lines. For a pump energy of 1.82 mJ/pulse, an intense line with FWHM ∼0.4 nmwas observed at 576.5 nm.
Resumo:
This study was conducted to identify the concentration dependence of the operating wavelengths and the relative intensities in which a dye mixture doped polymer optical fibre can operate. A comparative study of the radiative and Forster type energy transfer processes in Coumarin 540:Rhodamine 6G, Coumarin 540:Rhodamine B and Rhodamine 6G:Rhodamine B in methyl methacrylate (MMA) and poly(methyl methacrylate) (PMMA) was done by fabricating a series of dye mixture doped polymer rods which have two emission peaks with varying relative intensities. These rods can be used as preforms for the fabrication of polymer optical fibre amplifiers operating in the multi-wavelength regime. The 445 nm line from an Nd:YAG pumped optical parametric oscillator (OPO) was used as the excitation source for the first two dye pairs and a frequency doubled Nd:YAG laser emitting at 532 nm was used to excite the Rh 6G:Rh B pair. The fluorescence lifetimes of the donor molecule in pure form as well as in the mixtures were experimentally measured in both monomer and polymer matrices by time-correlated single photon counting technique. The energy transfer rate constants and transfer efficiencies were calculated and their dependence on the acceptor concentration was analysed. It was found that radiative energy transfer mechanisms are more efficient in all the three dye pairs in liquid and solid matrices.
Resumo:
We present our recent achievements in the growing and optical characterization of KYb(WO4)2 (hereafter KYbW) crystals and demonstrate laser operation in this stoichiometric material. Single crystals of KYbW with optimal crystalline quality have been grown by the top-seeded-solution growth slow-cooling method. The optical anisotropy of this monoclinic crystal has been characterized, locating the tensor of the optical indicatrix and measuring the dispersion of the principal values of the refractive indices as well as the thermo-optic coefficients. Sellmeier equations have been constructed valid in the visible and near-IR spectral range. Raman scattering has been used to determine the phonon energies of KYbW and a simple physical model is applied for classification of the lattice vibration modes. Spectroscopic studies (absorption and emission measurements at room and low temperature) have been carried out in the spectral region near 1 µm characteristic for the ytterbium transition. Energy positions of the Stark sublevels of the ground and the excited state manifolds have been determined and the vibronic substructure has been identified. The intrinsic lifetime of the upper laser level has been measured taking care to suppress the effect of reabsorption and the intrinsic quantum efficiency has been estimated. Lasing has been demonstrated near 1074 nm with 41% slope efficiency at room temperature using a 0.5 mm thin plate of KYbW. This laser material holds great promise for diode pumped high-power lasers, thin disk and waveguide designs as well as for ultrashort (ps/fs) pulse laser systems.