847 resultados para Job insertion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the influence of different insertion torques on healing of implants loaded immediately or left unloaded.Material and methods: In six Labrador dogs, all mandibular premolars and molars were extracted. After 4 months of healing, flaps were elevated, and two implant sites were prepared at each side of the mandible. The distal sites were prepared conventionally while the mesial sites were underprepared by 0.3 mm. As a consequence, different final insertion torques of about 30 Ncm at the distal and >70 Ncm at the mesial sites were recorded. Healing abutments were applied to the left and transmucosal abutments to the right side. Flaps were sutured, crown preparation of the upper right second and third premolars was performed, and impressions were taken. Within 24 h, crowns were cemented both to implants and teeth in the right side of the mouth. After 4 months, the animals were sacrificed and ground sections obtained for histological evaluation.Results: A higher buccal bony crestal resorption and a more apical position of the coronal level of osseointegration were found at the loaded compared with the unloaded sites. MBIC% and percentages of peri-implant mineralized tissue (MB%) were higher at the loaded compared with the unloaded sites. Moreover, a higher MBIC% was found at the lower compared with the higher final insertion torque.Conclusions: Immediate loading does not seem to have a negative effect on osseointegration. High torque values for the immediate loading procedures were not necessary. Probably, low torque values, were sufficient to obtain primary stability and hence may provide better osseointegration than high torque value.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This conclusion of course work aims to investigate the city of Limerick / SP, in order to question whether there are and what public policies developed by local, if there are training places for young people and targeting the job market or even partnerships between the city and local businesses seeking to supply the concrete conditions of preparation and targeting young people for the labor market. All changes in education accompanied the need to provide skilled labor to contribute to the country's economic development. The work is divided into several chapters. The first chapter is about the whole historical development of professional education in Brazil and new challenges. The second chapter discusses the reality of the world of work changes and their consequences, and the issue of working children and adolescents. The third chapter is about the difficulty of insertion of the poor youth in the current job market. The fourth chapter presents the city of Limerick to the needs of professional schools to meet the large number of trades and industries, which are currently listed by the educational institutions of the city and programs signed between the Municipal bodies and institutions such as SENAC (National Service of Commercial Learning) and Senai (National Service of Industrial Learning). The fifth chapter presents an interview with the CAMPL the city of Limerick, whose goal and give professional training to teens to get the first employee. Readings were taken from several authors who treat on the subject

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the effect of the insertion technique for resin cement and mechanical cycling on the bond strength between fiber posts and root dentin.Materials and Methods: Sixty-four single-rooted bovine teeth were endodontically prepared to receive glass-fiber posts. The insertion of cement into the root canal was performed using one of the following techniques: POS, insertion with the post; LEN, the use of a lentulo-type drill; EXP, insertion with a straight-tip explorer; or CEN, the use of a Centrix syringe. Half of the specimens were mechanically cycled. All specimens were sectioned into slices of 1.8 mm for the push-out test and 0.5 mm for analysis of the cement layer quality.Results: The insertion technique affected the interaction between factors (bond strength and mechanical cycling; p < 0.0001). Insertion of the Centrix syringe after mechanical cycling showed the highest bond values (13.6 +/- 3.2 MPa). Group-to-group comparisons for baseline and cycled conditions indicated that mechanical cycling significantly influenced the bond strength (p < 0.0001) of the POS and CEN groups. The quality of the cement layer did not differ between the techniques when evaluated in the middle (p = 0.0612) and cervical (p = 0.1119) regions, but did differ in the apical region (p = 0.0097), where the CEN group had better layer quality for the two conditions tested (baseline and cycled).Conclusion: The use of the Centrix syringe improved the homogeneity of the cement layer, reducing the defects in the layer and increasing adhesive strength values to dentin, even after mechanical cycling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The evaluation of the perception of graduates is an essential strategy to support the political project educational in universities. Objective: This study aimed to verify the perception of dentists which are working in the labor market, about the difficulties of professional insertion after the graduation, positives and negatives aspects and suggestions regarding the training received. Methodology: This is a qualitative survey conducted with graduates of the years 2000 to 2010, of dentistry course from a Brazilian Public University. A self-administered questionnaire was sent by mail/email to all graduates in the period. The data were transcribed and subjected to content analysis, divided into pre-analysis, characterized by carefully reading floating, material exploration, guidelines for finding the analysis itself. Result: The categories related to the difficulties in early life were: getting a job/workplace, adequate working conditions and low pay, insecurity and confrontation obtained the academic and lack of administrative experience. The perceived positive aspects for the training were: good infrastructure and reputation of the university, integrating teaching-research, teacher-student relationship. The negative aspects comprised the following categories: administrative preparation, lack of integration between content theoretical/ practical, concepts used in the labor market. The suggestions presented are consistent with the difficulties to the beginning of professional life and the negative aspects. Conclusion: The professionals have faced the saturation of the labor market and different reality from those found in academic life. Despite the positive aspects, graduates suggest changes in the course conducted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This descriptive study addresses the job satisfaction of nurse managers and clinical nurses working at the Hematology and Hemotherapy Services of a public hospital in Sao Paulo. The study objectives were to identify the factors that caused job satisfaction among nurse managers and clinical nurses, and support the results in the development of indicators to evaluate the quality of nursing human resource management. The components of the study were: autonomy, interaction, professional status, job requirements, organizational norms and remuneration. Participants were 44 nurses. Data were collected using a Job Satisfaction Index (JSI) questionnaire. In conclusion, this study permitted the identification of the clinical nurse group, which was the most satisfied, with a JSI of 10.5; the managerial group scored 10.0. Regarding the satisfaction levels in regards to the current activity, 88.9% of the nurse managers reported feeling satisfied, as did 90.9% of clinical nurses. For both groups, autonomy was the component with the highest level of professional satisfaction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Shift workers from control centers of electrical systems are a group that has received little attention in Brazil. This study aimed to compare workers' job satisfaction at five control centers of a Brazilian company electrical system, and according to their job titles. Method: The Organization Satisfaction Index (OSI) questionnaire to assess job satisfaction was used. ANOVA was used to compare OSI means, according to job title and control center. The results showed that there is no difference in job satisfaction among job titles, but a significant difference was found according to the control center. A single organizational culture cannot be applied to several branches. It is required to implement actions that would result in job satisfaction improvements among workers of all studied control rooms centers. The high level of education of operators working in all centers might have contributed to the similar values of perceived satisfaction among distinct job titles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate the effect of insertion torque on micromotion to a lateral force in three different implant designs. Material and methods: Thirty-six implants with identical thread design, but different cutting groove design were divided in three groups: (1) non-fluted (no cutting groove, solid screw-form); (2) fluted (901 cut at the apex, tap design); and (3) Blossomt (Patent pending) (non-fluted with engineered trimmed thread design). The implants were screwed into polyurethane foam blocks and the insertion torque was recorded after each turn of 901 by a digital torque gauge. Controlled lateral loads of 10N followed by increments of 5 up to 100N were sequentially applied by a digital force gauge on a titanium abutment. Statistical comparison was performed with two-way mixed model ANOVA that evaluated implant design group, linear effects of turns and displacement loads, and their interaction. Results: While insertion torque increased as a function of number of turns for each design, the slope and final values increased (Po0.001) progressively from the Blossomt to the fluted to the non-fluted design (M +/- standard deviation [SD] = 64.1 +/- 26.8, 139.4 +/- 17.2, and 205.23 +/- 24.3 Ncm, respectively). While a linear relationship between horizontal displacement and lateral force was observed for each design, the slope and maximal displacement increased (Po0.001) progressively from the Blossomt to the fluted to the non-fluted design (M +/- SD 530 +/- 57.7, 585.9 +/- 82.4, and 782.33 +/- 269.4 mm, respectively). There was negligible to moderate levels of association between insertion torque and lateral displacement in the Blossomt, fluted and non-fluted design groups, respectively. Conclusion: Insertion torque was reduced in implant macrodesigns that incorporated cutting edges, and lesser insertion torque was generally associated with decreased micromovement. However, insertion torque and micromotion were unrelated within implant designs, particularly for those designs showing the least insertion torque.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The discrepancies between social and biological timing are reflected in shift workers' well-being. The aim of this study was to verify the association between job satisfaction and chronotype among day and night nursing personnel. Several variables, including seniority at the hospital and, in the same shift, sleep duration, quality of sleep, sleepiness and willingness to change sleep timing were also analyzed. Chronotype was calculated by using the morningness-eveningness questionnaire. We studied 514 nursing professionals from a public university hospital. Among the day workers, the higher the morningness, the more the workers were satisfied with their job. In contrast, among night workers, job satisfaction was associated with sleep quality and seniority at the hospital but not with chronotype. Our results suggest that an agreement between work schedule and chronotype may help to increase job satisfaction among diurnal workers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This case-control study aimed to test the association between voice disorders and job stress among public schoolteachers in Sao Paulo, Brazil. The groups consisted of teachers with (n = 165) and without (n = 105) voice-related complaints. Both groups answered the questionnaires Conditions of Vocal Production and Job Stress Scale. Analysis of cases and controls showed comparable samples, differing only by vocal symptoms. There was a statistically significant difference between cases and controls in relation to job stress involving high strain (OR = 2.1;95%CI: 1.1-3.9), which places high demands combined with low job control. High strain in cases in this study represents the highest risk of physical and mental disorders for teachers. Loss of voice prevents teachers from continuing in their professional role, eliminates their professional identity, and jeopardizes their career.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and objectives: Longitudinal, prospective, randomized, blinded Trial to assess the influence of pleural drain (non-toxic PVC) site of insertion on lung function and postoperative pain of patients undergoing coronary artery bypass grafting in the first three days post-surgery and immediately after chest tube removal. Method: Thirty six patients scheduled for elective myocardial revascularization with cardiopulmonary bypass (CPB) were randomly allocated into two groups: SX group (subxiphoid) and IC group (intercostal drain). Spirometry, arterial blood gases, and pain tests were recorded. Results: Thirty one patients were selected, 16 in SX group and 15 in IC group. Postoperative (PO) spirometric values were higher in SX than in IC group (p < 0.05), showing less influence of pleural drain location on breathing. PaO2 on the second PO increased significantly in SX group compared with IC group (p < 0.0188). The intensity of pain before and after spirometry was lower in SX group than in IC group (p < 0.005). Spirometric values were significantly increased in both groups after chest tube removal. Conclusion: Drain with insertion in the subxiphoid region causes less change in lung function and discomfort, allowing better recovery of respiratory parameters.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Insertion of totally implantable catheters via deep vessels that drain into the superior vena cava results in a lower incidence of venous thrombosis and infection as compared to catheters inserted into femoral and arm veins. Superior vena cava obstruction and inadequacy of the thoracic wall are conditions that prevent reservoir implantation in the chest wall. In this article, we describe a technical innovation that enables the pocket to be fixed in the arm while still allowing access to be achieved via the internal jugular vein. Method: The procedure reported maintains the use of the internal jugular vein for access even when the patient's chest is not suited for reservoir implantation, which is localized in the arm. Results: The procedure was successful and no complications occurred. The position of the catheter tip did not alter with arm movement. Conclusion: The implantation of a port reservoir in the arm following venous access via the internal jugular vein is both safe and convenient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mini-implant insertion requires accurate surgical technique. This study shows an insertion technique using only tooth crown references; its scientific basis is evaluated radiographically. The sample consisted of 213 inter-radicular septa, evaluated in 53 bitewing radiographs. The proximal contour of adjacent tooth crowns was used to define septum width. The midpoint of the septum width was linked to the interdental contact point to determine septum midline. The distances from septum midline to "mesial and distal teeth were measured to evaluate the septum midline centralization degree in two different septum heights. The difference between mesial and distal distances represented the septum midline deviation degree. The mesial and distal distances were compared by t-tests, and the septum midline deviation was correlated with septum height using Pearson's correlation test. The mesial and distal distances were not statistically different in the midpoint of the septum height, but they were different at the apical septum height. There was a moderate correlation (r = 0.45) between septum midline deviation and septum height. The tooth crown references evaluated on interproximal radiographs determine a high centralization degree of the septum midline on which the insertion site could be defined. The greater centralization degree was observed at the coronal septum area.