982 resultados para Inertial Measurement Unit
Resumo:
Introduction In addition to the common alterations and diseases inherent in the aging process, elderly persons with a history of leprosy are particularly vulnerable to dependence because of disease-related impairments. Objective determine whether physical impairment from leprosy is associated with dependence among the elderly. Methods An analytical cross-sectional study of elderly individuals with a history of leprosy and no signs of cognitive impairment was conducted using a database from a former leprosy colony-hospital. The patients were evaluated for dependence in the basic activities of daily living (BADL) and instrumental activities of daily living (IADL), respectively) and subjected to standard leprosy physical disability grading. Subsequently, descriptive and univariate analyses were conducted, the latter using Pearson's chi-squared test. Results A total of 186 elderly persons were included in the study. Of these individuals, 53.8% were women, 49.5% were older than 75 years of age, 93% had four or less years of formal education, 24.2% lived in an institution for the long-term care of the elderly (ILTC), and 18.3% had lower limb amputations. Among those evaluated, 79.8% had visible physical impairments from leprosy (grade 2), 83.3% were independent in BADL, and 10.2% were independent in IADL. There was a higher impairment grade among those patients who were IADL dependent (p=0.038). Conclusion s: The leprosy physical impairment grade is associated with dependence for IADL, creating the need for greater social support and systematic monitoring by a multidisciplinary team. The results highlight the importance of early diagnosis and treatment of leprosy to prevent physical impairment and dependence in later years.
Resumo:
RESUMO: A hipertensão arterial (HA) é uma patologia altamente prevalente, embora claramente subdiagnosticada, em doentes com síndrome de apneia obstrutiva do sono (SAOS). Estas duas patologias apresentam uma estreita relação e a monitorização ambulatória da pressão arterial (MAPA), por um período de 24 horas, parece ser o método mais preciso para o diagnóstico de hipertensão em doentes com SAOS. No entanto, esta ferramenta de diagnóstico para além de ser dispendiosa e envolver um número acrescido de meios técnicos e humanos, é mais morosa e, por conseguinte, não é utilizada por rotina no contexto do diagnóstico da SAOS. Por outro lado, apesar da aplicação de pressão positiva contínua nas vias aéreas (CPAP – Continous Positive Airway Pressure) ser considerada a terapêutica de eleição para os doentes com SAOS, o seu efeito no abaixamento da pressão arterial (PA) parece ser modesto, exigindo, por conseguinte, a implementação concomitante de terapêutica anti-hipertensora. Acontece que são escassos os dados relativos aos regimes de fármacos anti-hipertensores utilizados em doentes com SAOS e, acresce ainda que, as guidelines terapêuticas para o tratamento farmacológico da HA, neste grupo particular de doentes, permanecem, até ao momento, inexistentes. A utilização de modelos animais de hipóxia crónica intermitente (CIH), que mimetizam a HA observada em doentes com SAOS, revela-se extremamente importante, uma vez que se torna imperativo identificar fármacos que promovam um controle adequado da PA neste grupo de doentes. No entanto, estudos concebidos com o intuito de investigar o efeito anti-hipertensor dos fármacos neste modelo animal revelam-se insuficientes e, por outro lado, os escassos estudos que testaram fármacos anti-hipertensores neste modelo não foram desenhados para responder a questões de natureza farmacológica. Acresce ainda que se torna imprescindível garantir a escolha de um método para administração destes fármacos que seja não invasivo e que minimize o stress do animal. Embora a gavagem seja uma técnica indiscutivelmente eficaz e amplamente utilizada para a administração diária de fármacos a animais de laboratório, ela compreende uma sequência de procedimentos geradores de stress para os animais e, que podem por conseguinte, constituir um viés na interpretação dos resultados obtidos. O objectivo global da presente investigação translacional foi contribuir para a identificação de fármacos anti-hipertensores mais efectivos para o tratamento da HT nos indivíduos com SAOS e investigar mecanismos subjacentes aos efeitos sistémicos associadas à SAOS bem como a sua modulação por fármacos anti-hipertensores. Os objectivos específicos foram: em primeiro lugar,encontrar novos critérios, baseados nas medidas antropométricas, que permitam a identificação de doentes com suspeita de SAOS, que erroneamente se auto-classifiquem como nãohipertensos, e desta forma promover um uso mais criterioso do MAPA; em segundo lugar, investigar a existência de uma hipotética associação entre os esquemas de fármacos antihipertensores e o controle da PA (antes e após a adaptação de CPAP) em doentes com SAOS em terceiro lugar, avaliar a eficácia do carvedilol (CVD), um fármaco bloqueador β-adrenérgico não selectivo com actividade antagonista α1 intrínseca e propriedades anti-oxidantes num modelo animal de hipertensão induzida pela CIH; em quarto lugar, explorar os efeitos da CIH sobre o perfil farmacocinético do CVD; e, em quinto lugar, investigar um método alternativo à gavagem para a administração crónica de fármacos anti-hipertensores a animais de laboratório. Com este intuito, na primeira fase deste projecto, fizemos uso de uma amostra com um número apreciável de doentes com SAOS (n=369), que acorreram, pela primeira vez, à consulta de Patologia do Sono do CHLN e que foram submetidos a um estudo polissonográfico do sono, à MAPA e que preencheram um questionário que contemplava a obtenção de informação relativa ao perfil da medicação anti-hipertensora em curso. Numa segunda fase, utilizámos um modelo experimental de HT no rato induzida por um paradigma de CIH. Do nosso trabalho resultaram os seguintes resultados principais: em primeiro lugar, o índice de massa corporal (IMC) e o perímetro do pescoço (PP) foram identificados como preditores independentes de “auto-classificação errónea” da HA em doentes com suspeita de SAOS; em segundo lugar, não encontramos qualquer associação com significado estatístico entre os vários esquemas de fármacos anti-hipertensores bem como o número de fármacos incluídos nesse esquemas, e o controle da PA (antes e depois da adaptação do CPAP); em terceiro lugar, apesar das doses de 10, 30 e 50 mg/kg de carvedilol terem promovido uma redução significativa da frequência cardíaca, não foi observado qualquer decréscimo na PA no nosso modelo animal; em quarto lugar, as razões S/(R+S) dos enantiómeros do CVD nos animais expostos à CIH e a condições de normóxia revelaram-se diferentes; e, em quinto lugar, a administração oral voluntária mostrou ser um método eficaz para a administração diária controlada de fármacos anti-hipertensores e que é independente da manipulação e contenção do animal. Em conclusão, os resultados obtidos através do estudo clínico revelaram que o controle da PA, antes e após a adaptação do CPAP, em doentes com SAOS é independente, quer do esquema de fármacos anti-hipertensores, quer do número de fármacos incluídos num determinado esquema. Os nossos resultados salientam ainda a falta de validade da chamada self-reported hypertension e sugerem que em todos os doentes com suspeita de SAOS, com HA não diagnosticada e com um IMC e um PP acima de 27 kg/m2 e 39 cm, respectivamente, a confirmação do diagnóstico de HA deverá ser realizada através da MAPA, ao invés de outros métodos que com maior frequência são utilizados com este propósito. Os resultados obtidos no modelo animal de HA induzida pela CIH sugerem que o bloqueio do sistema nervoso simpático, juntamente com os supostos efeitos pleiotrópicos do CVD, não parece ser a estratégia mais adequada para reverter este tipo particular de hipertensão e indicam que as alterações farmacocinéticas induzidas pela CIH no ratio S/(R+S) não justificam a falta de eficácia anti-hipertensora do CVD observada neste modelo animal. Por último, os resultados do presente trabalho suportam ainda a viabilidade da utilização da administração oral voluntária, em alternativa à gavagem, para a administração crónica de uma dose fixa de fármacos anti-hipertensores.---------------------------- ABSTRACT: Hypertension (HT) is a highly prevalent condition, although under diagnosed, in patients with obstructive sleep apnea (OSA). These conditions are closely related and 24-hour ambulatory blood pressure monitoring (ABPM) seems to be the most accurate measurement for diagnosing hypertension in OSA. However, this diagnostic tool is expensive and time-consuming and, therefore, not routinely used. On the other hand, although continuous positive airway pressure (CPAP) is considered the gold standard treatment for symptomatic OSA, its lowering effect on blood pressure (BP) seems to be modest and, therefore, concomitant antihypertensive therapy is still required. Data on antihypertensive drug regimens in patients with OSA are scarce and specific therapeutic guidelines for the pharmacological treatment of hypertension in these patients remain absent. The use of animal models of CIH, which mimic the HT observed in patients with OSA, is extremely important since it is imperative to identify preferred compounds for an adequate BP control in this group of patients. However, studies aimed at investigating the antihypertensive effect of antihypertensive drugs in this animal model are insufficient, and most reports on CIH animal models in which drugs have been tested were not designed to respond to pharmacological issues. Moreover, when testing antihypertensive drugs (AHDs) it becomes crucial to ensure the selection of a non-invasive and stress-free method for drug delivery. Although gavage is effective and a widely performed technique for daily dosing in laboratory rodents, it comprises a sequence of potentially stressful procedures for laboratory animals that may constitute bias for the experimental results. The overall goal of the present translational research was to contribute to identify more effective AHDs for the treatment of hypertension in patients with OSA and investigate underlying mechanisms of systemic effects associated with OSA, as well as its modulation by AHDs. The specific aims were: first, to find new predictors based on anthropometric measures to identify patients that misclassify themselves as non-hypertensive, and thereby promote the selective use of ABPM; second, to investigate a hypothetical association between ongoing antihypertensive regimens and BP control rates in patients with OSA, before and after CPAP adaptation; third, to determine, in a rat model of CIH-induced hypertension, the efficacy of carvedilol (CVD), a nonselective beta-blocker with intrinsic anti-α1-adrenergic activity and antioxidant properties; fourth, to explore the effects of CIH on the pharmacokinetics profile of CVD and fifth, to investigate an alternative method to gavage, for chronic administration of AHDs to laboratory rats. For that, in the first phase of this project, we used a sizeable sample of patients with OSA (n=369), that attended a first visit at Centro Hospitalar Lisboa Norte, EPE Sleep Unit, and underwent overnight polysomnography, 24-h ABPM and filled a questionnaire that included ongoing antihypertensive medication profile registration. In the second phase, a rat experimental model of HT induced by a paradigm of CIH that simulates OSA was used. The main findings of this work were: first, body mass index (BMI) and neck circumference (NC) were identified as independent predictors of hypertension misclassification in patients suspected of OSA; second, in patients with OSA, BP control is independent of both the antihypertensive regimen and the number of antihypertensive drugs, either before or after CPAP adaptation; third, although the doses of 10, 30 and 50 mg/Kg of CVD promoted a significant reduction in heart rate, no decrease in mean arterial pressure was observed; fourth, the S/(R+S) ratios of CVD enantiomers, between rats exposed to CIH and normoxic conditions, were different and fifth, voluntary ingestion proved to be an effective method for a controlled daily dose administration, with a define timetable, that is independent of handling and restraint procedures. In conclusion, the clinical study showed that BP control in OSA patients is independent of both the antihypertensive regimen and the number of antihypertensive drugs. Additionally, our results highlight the lack of validity of self-reported hypertension and suggest that all patients suspected of OSA with undiagnosed hypertension and with a BMI and NC above 27 Kg/m2 and 39 cm should be screened for hypertension, through ABPM. The results attained in the rat model of HT related to CIH suggest that the blockade of the sympathetic nervous system together with the putative pleiotropic effects of carvedilol is not able to revert hypertension induced by CIH and point out that the pharmacokinetic changes induced by CIH on S/(R+S) ratio are not apparently responsible for the lack of efficacy of carvedilol in reversing this particular type of hypertension. Finally, the results here presented support the use of voluntary oral administration as a viable alternative to gavage for chronic administration of a fixed dose of AHDs.
Resumo:
Introduction Surveillance of nosocomial infections (NIs) is an essential part of quality patient care; however, there are few reports of National Healthcare Safety Network (NHSN) surveillance in neonatal intensive care units (NICUs) and none in developing countries. The purpose of this study was to report the incidence of NIs, causative organisms, and antimicrobial susceptibility patterns in a large cohort of neonates admitted to the NICU during a 16-year period. Methods The patients were followed 5 times per week from birth to discharge or death, and epidemiological surveillance was conducted according to the NHSN. Results From January 1997 to December 2012, 4,615 neonates, representing 62,412 patient-days, were admitted to the NICU. The device-associated infection rates were as follows: 17.3 primary bloodstream infections per 1,000 central line-days and 3.2 pneumonia infections per 1,000 ventilator-days. A total of 1,182 microorganisms were isolated from sterile body site cultures in 902 neonates. Coagulase-negative staphylococci (CoNS) (34.3%) and Staphylococcus aureus (15.6%) were the most common etiologic agents isolated from cultures. The incidences of oxacillin-resistant CoNS and Staphylococcus aureus were 86.4% and 28.3%, respectively. Conclusions The most important NI remains bloodstream infection with staphylococci as the predominant pathogens, observed at much higher rates than those reported in the literature. Multiresistant microorganisms, especially oxacillin-resistant staphylococci and gram-negative bacilli resistant to cephalosporin were frequently found. Furthermore, by promoting strict hygiene measures and meticulous care of the infected infants, the process itself of evaluating the causative organisms was valuable.
Resumo:
INTRODUCTION: To evaluate predictive indices for candidemia in an adult intensive care unit (ICU) and to propose a new index. METHODS: A prospective cohort study was conducted between January 2011 and December 2012. This study was performed in an ICU in a tertiary care hospital at a public university and included 114 patients staying in the adult ICU for at least 48 hours. The association of patient variables with candidemia was analyzed. RESULTS: There were 18 (15.8%) proven cases of candidemia and 96 (84.2%) cases without candidemia. Univariate analysis revealed the following risk factors: parenteral nutrition, severe sepsis, surgical procedure, dialysis, pancreatitis, acute renal failure, and an APACHE II score higher than 20. For the Candida score index, the odds ratio was 8.50 (95% CI, 2.57 to 28.09); the sensitivity, specificity, positive predictive value, and negative predictive value were 0.78, 0.71, 0.33, and 0.94, respectively. With respect to the clinical predictor index, the odds ratio was 9.45 (95%CI, 2.06 to 43.39); the sensitivity, specificity, positive predictive value, and negative predictive value were 0.89, 0.54, 0.27, and 0.96, respectively. The proposed candidemia index cutoff was 8.5; the sensitivity, specificity, positive predictive value, and negative predictive value were 0.77, 0.70, 0.33, and 0.94, respectively. CONCLUSIONS: The Candida score and clinical predictor index excluded candidemia satisfactorily. The effectiveness of the candidemia index was comparable to that of the Candida score.
Resumo:
The spinning rotor gauge (SRG) is one of the most interesting vacuum gauges ever made, covering a pressure range of over seven orders of magnitude, with minimal gas interference (no pumping, ionization or heating of the measured gas), and a great stability of less than 1% drift per year. But despite its remarkable properties, apparently the SRG has not been further developed since the eighties, when it gained commercial interest. In this context, this dissertation aims at providing a starting point for a new line of investigation regarding this instrument, focused on the rotor itself. A brief study of different rotor geometries is provided, including a comparison between a cylindrical rotor and a spherical one. A cylindrical spinning rotor gauge (CSRG) is then proposed, based on the original SRG, but requiring a completely new lateral damping system. A prototype was built and tested against a non calibrated reference gauge.
Resumo:
Evaluation of Cyclosporin A (CyA) blood concentration is imperative in solid organ transplantation in order to achieve maximal immunosuppression with the least side effects. We compared the results of whole blood concentrations of CyA in 50 blood samples simultaneously evaluated by the fluorescent polarization immune assay (TDx) and the enzymatic competitive immune assay (EMIT 2000). There was a strong correlation between both kits for any range of CyA blood concentration (R=0.99, p<0.001). The within-run and between-days coefficient of variation were less than 4% for both assays. The cost for each CyA measurement was 50% lower for the EMIT assay when compared to the TDx assay. We concluded that the EMIT is as accurate as the TDx in measuring CyA blood concentration and has the advantage of a lower cost, as well as the possibility of widespread access to the EMIT methodology in contrast to the TDx equipment, allowing the laboratory to perform several routines within a working day.
Resumo:
PURPOSE: To determine the incidence and characteristics of nonimmune hydrops fetalis in the newborn population. METHOD: A retrospective study of the period between 1996 and 2000, including all newborns with a prenatal or early neonatal diagnosis of nonimmune hydrops fetalis, based on clinical history, physical examination, and laboratory evaluation. The following were analyzed: prenatal follow-up, delivery type, gender, birth weight, gestational age, presence of perinatal asphyxia, nutritional classification, etiopathic diagnosis, length of hospital stay, mortality, and age at death. RESULTS: A total of 47 newborns with hydrops fetalis (0.42% of live births), 18 (38.3%) with the immune form and 29 (61.7%) with the nonimmune form, were selected for study. The incidence of nonimmune hydrops fetalis was 1 per 414 neonates. Data was obtained from 21 newborns, with the following characteristics: 19 (90.5%) were suspected from prenatal diagnosis, 18 (85.7%) were born by cesarean delivery, 15 (71.4%) were female, and 10 (47.6%) were asphyxiated. The average weight was 2665.9 g, and the average gestational age was 35 3/7 weeks; 14 (66.6%) were preterm; 18 (85.0 %) appropriate delivery time; and 3 (14.3%) were large for gestational age. The etiopathic diagnosis was determined for 62%, which included cardiovascular (19.0%), infectious (9.5%), placental (4.8%), hematologic (4.7%), genitourinary (4.8%), and tumoral causes (4.8%), and there was a combination of causes in 9.5%. The etiology was classified as idiopathic in 38%. The length of hospital stay was 26.6 ± 23.6 days, and the mortality rate was 52.4%. CONCLUSIONS: The establishment of a suitable etiopathic diagnosis associated with prenatal detection of nonimmune hydrops fetalis can be an important step in reducing the neonatal mortality rate from this condition.
Ethical aspects in the management of the terminally ill patient in the pediatric intensive care unit
Resumo:
OBJECTIVE: To identify the prevalence of management plans and decision-making processes for terminal care patients in pediatric intensive care units. METHODOLOGY: Evidence-based medicine was done by a systematic review using an electronic data base (LILACS, 1982 through 2000) and (MEDLINE, 1966 through 2000). The key words used are listed and age limits (0 to 18 years) were used. RESULTS: One hundred and eighty two articles were found and after selection according to the exclusion/inclusion criteria and objectives 17 relevant papers were identified. The most common decisions found were do-not-resuscitation orders and withdrawal or withholding life support care. The justifications for these were "imminent death" and "unsatisfatory quality of life". CONCLUSION: Care management was based on ethical principles aiming at improving benefits, avoiding harm, and when possible, respecting the autonomy of the terminally ill patient.
Resumo:
PURPOSE: To find out the prevalence of hypertension in employees of the Hospital and relate it to social demographic variables. METHODS: Blood pressure measurement was performed with a mercury sphygmomanometer, using an appropriate cuff size for arm circumference, weight, and height in a population sample of 864 individuals out of the 9,905 employees of a University General Hospital stratified by gender, age, and job position. RESULTS: Hypertension prevalence was 26% (62% of these reported being aware of their hypertension and 38% were unaware but had systolic/diastolic blood pressures of >140 and/or >90 mm Hg at the moment of the measurement). Of those who were aware of having hypertension, 51% were found to be hypertensive at the moment of the measurement. The prevalence was found to be 17%, 23%, and 29% (P <.05) in physicians, nursing staff, and "others", respectively. The univariate analysis showed a significant odds ratio for the male gender, age >50 years, work unit being the Institute of Radiology and the Administration Building, educational level
Resumo:
The effects of PMSs on the people’s behaviour represent a high degree of relevance in the context of an organization performance and success. Thus, motivational and behavioural consequences of performance measurements are far from being totally understood (Franco-Santos et al., 2012). This work project (WP) purposes going further regarding the consequences/effects on people’s behaviour of using PMSs in organizations. The researcher conducted 11 interviews to managers during a nine-month internship as a controller in a Portuguese multi-national company. The evidence from this WP suggests that the way how managers understand a PMS determines a lot the way how they behave. Data also supports that PMSs influences in several ways motivation, perceptions, participation and job-related stress of managers.
Resumo:
The innovative Horizon 2020 program sponsored by the European Union (EU) aims to promote and develop processes of waste integration in construction materials. However, several potential health hazards caused by building materials have been identified and, there-fore, there is an ongoing need to develop new recycling methods for hazardous wastes and effi-cient barriers in order to prevent toxic releases from the new construction solutions with wastes. This paper presents an overview that focus on two main aspects: the identification of the health risks related to radioactivity and heavy metals present in building materials and identification of these toxic substances in new construction solutions that contain recycled wastes. Different waste materials were selected and distinct methodologies of toxicity evaluation are presented to analyse the potential hazardous, the feasibility of using those wastes and the achievement of op-timal construction solutions involving wastes.
Resumo:
Children are an especially vulnerable population, particularly in respect to drug administration. It is estimated that neonatal and pediatric patients are at least three times more vulnerable to damage due to adverse events and medication errors than adults are. With the development of this framework, it is intended the provision of a Clinical Decision Support System based on a prototype already tested in a real environment. The framework will include features such as preparation of Total Parenteral Nutrition prescriptions, table pediatric and neonatal emergency drugs, medical scales of morbidity and mortality, anthropometry percentiles (weight, length/height, head circumference and BMI), utilities for supporting medical decision on the treatment of neonatal jaundice and anemia and support for technical procedures and other calculators and widespread use tools. The solution in development means an extension of INTCare project. The main goal is to provide an approach to get the functionality at all times of clinical practice and outside the hospital environment for dissemination, education and simulation of hypothetical situations. The aim is also to develop an area for the study and analysis of information and extraction of knowledge from the data collected by the use of the system. This paper presents the architecture, their requirements and functionalities and a SWOT analysis of the solution proposed.
Resumo:
The jet energy scale (JES) and its systematic uncertainty are determined for jets measured with the ATLAS detector using proton–proton collision data with a centre-of-mass energy of s√=7 TeV corresponding to an integrated luminosity of 4.7 fb −1 . Jets are reconstructed from energy deposits forming topological clusters of calorimeter cells using the anti- kt algorithm with distance parameters R=0.4 or R=0.6 , and are calibrated using MC simulations. A residual JES correction is applied to account for differences between data and MC simulations. This correction and its systematic uncertainty are estimated using a combination of in situ techniques exploiting the transverse momentum balance between a jet and a reference object such as a photon or a Z boson, for 20≤pjetT<1000 GeV and pseudorapidities |η|<4.5 . The effect of multiple proton–proton interactions is corrected for, and an uncertainty is evaluated using in situ techniques. The smallest JES uncertainty of less than 1 % is found in the central calorimeter region ( |η|<1.2 ) for jets with 55≤pjetT<500 GeV . For central jets at lower pT , the uncertainty is about 3 %. A consistent JES estimate is found using measurements of the calorimeter response of single hadrons in proton–proton collisions and test-beam data, which also provide the estimate for pjetT>1 TeV. The calibration of forward jets is derived from dijet pT balance measurements. The resulting uncertainty reaches its largest value of 6 % for low- pT jets at |η|=4.5 . Additional JES uncertainties due to specific event topologies, such as close-by jets or selections of event samples with an enhanced content of jets originating from light quarks or gluons, are also discussed. The magnitude of these uncertainties depends on the event sample used in a given physics analysis, but typically amounts to 0.5–3 %.
Resumo:
A measurement is presented of the tt¯ inclusive production cross section in pp collisions at a center-of-mass energy of s√=8 TeV using data collected by the ATLAS detector at the CERN Large Hadron Collider. The measurement was performed in the lepton+jets final state using a data set corresponding to an integrated luminosity of 20.3 fb−1. The cross section was obtained using a likelihood discriminant fit and b-jet identification was used to improve the signal-to-background ratio. The inclusive tt¯ production cross section was measured to be 260±1(stat)+22−23(stat)±8(lumi)±4(beam) pb assuming a top-quark mass of 172.5 GeV, in good agreement with the theoretical prediction of 253+13−15 pb. The tt¯→(e,μ)+jets production cross section in the fiducial region determined by the detector acceptance is also reported.