892 resultados para HVDC Multilevel Converters


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The objective of the study was to develop a model for estimating patient 28-day in-hospital mortality using 2 different statistical approaches. DESIGN: The study was designed to develop an outcome prediction model for 28-day in-hospital mortality using (a) logistic regression with random effects and (b) a multilevel Cox proportional hazards model. SETTING: The study involved 305 intensive care units (ICUs) from the basic Simplified Acute Physiology Score (SAPS) 3 cohort. PATIENTS AND PARTICIPANTS: Patients (n = 17138) were from the SAPS 3 database with follow-up data pertaining to the first 28 days in hospital after ICU admission. INTERVENTIONS: None. MEASUREMENTS AND RESULTS: The database was divided randomly into 5 roughly equal-sized parts (at the ICU level). It was thus possible to run the model-building procedure 5 times, each time taking four fifths of the sample as a development set and the remaining fifth as the validation set. At 28 days after ICU admission, 19.98% of the patients were still in the hospital. Because of the different sampling space and outcome variables, both models presented a better fit in this sample than did the SAPS 3 admission score calibrated to vital status at hospital discharge, both on the general population and in major subgroups. CONCLUSIONS: Both statistical methods can be used to model the 28-day in-hospital mortality better than the SAPS 3 admission model. However, because the logistic regression approach is specifically designed to forecast 28-day mortality, and given the high uncertainty associated with the assumption of the proportionality of risks in the Cox model, the logistic regression approach proved to be superior.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertation presented to obtain the PhD degree in Electrical and Computer Engineering - Electronics

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e Computadores

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho baseia se na necessidade de aumentar as fontes renováveis de energia, reduzindo assim a dependência de fontes não renováveis, principalmente as poluentes como as de provenientes de combustíveis fosseis. A fonte de energia renovável explorada neste trabalho é a advinda de energia solar, com a utilização de painéis solares e métodos de extração para converter esta energia em energia elétrica e assim poder utilizar esta energia de forma eficiente. A energia produzida por painéis fotovoltaicos se apresenta em forma de corrente continua, tendo assim a necessidade do uso de conversores CC-CA, ou ditos inversores de tensão, para utilização da mesma, já que a maioria do equipamentos que utilizam energia elétrica são construídos em forma a serem abastecidos com energia elétrica em corrente alternada. Como este trabalho foca na injeção da energia produzida pelos painéis FV na rede de distribuição de baixa tensão, faz se necessário o uso de um PLL para garantir que o sistema inversor esteja em sincronismo com a rede de distribuição e possa garantir a entrega de energia ativa. Por fim mas não menos importante, é utilizado neste projeto técnicas de MPPT para garantir um maior aproveitamento da energia proveniente dos painéis FV, ajudando assim a melhorar a eficácia deste tipo de energia, sendo mais fiável e viável.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Benefits of long-term monitoring have drawn considerable attention in healthcare. Since the acquired data provides an important source of information to clinicians and researchers, the choice for long-term monitoring studies has become frequent. However, long-term monitoring can result in massive datasets, which makes the analysis of the acquired biosignals a challenge. In this case, visualization, which is a key point in signal analysis, presents several limitations and the annotations handling in which some machine learning algorithms depend on, turn out to be a complex task. In order to overcome these problems a novel web-based application for biosignals visualization and annotation in a fast and user friendly way was developed. This was possible through the study and implementation of a visualization model. The main process of this model, the visualization process, comprised the constitution of the domain problem, the abstraction design, the development of a multilevel visualization and the study and choice of the visualization techniques that better communicate the information carried by the data. In a second process, the visual encoding variables were the study target. Finally, the improved interaction exploration techniques were implemented where the annotation handling stands out. Three case studies are presented and discussed and a usability study supports the reliability of the implemented work.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

De modo a garantir as metas propostas pela União Europeia de diminuição de emissão de gases poluentes, alguns países membros apostaram na tecnologia eólica offshore. Com a evolução tecnológica, estes países pretendem aumentar as potências instaladas nos parques eólicos offshore, garantindo a sua otimização ao estarem em águas profundas, tendo assim um maior aproveitamento do potencial eólico. Com esta dissertação, realizou-se um estudo para analisar, sob o ponto de vista de modelos, as limitações dos sistemas de transmissão em HVAC (High Voltage Alternating Current) quando estabelecidos em cabos submarinos. Os mecanismos dos sistemas de alimentação em HVAC, na forma tradicional (linhas aérea), são confrontados com condicionalismos. Este tipo de infraestrutura submarina impõe restrições, pelo simples facto dos parâmetros de capacidade e indutância serem bastante significativos, que para uma situação de trânsito de energia, inviabilizam o transporte de energia, devido ao elevado consumo de potência reativa, bem como os seus custos extremamente elevados. Assim, os sistemas de alimentação em HVAC quando aplicados a parques eólicos offshore apresentam limitações. O recurso à tecnologia HVDC (High Voltage Direct Current), poderá ser a solução que se revela mais adequada para os sistemas de transmissão de energia associados aos parques eólicos offshore. Para além dos fatores técnicos é fundamental considerar os custos associados à construção e exploração do parque eólico, sendo fundamental analisar todos os dados relacionados com o projeto.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper focuses on a PV system linked to the electric grid by power electronic converters, identification of the five parameters modeling for photovoltaic systems and the assessment of the shading effect. Normally, the technical information for photovoltaic panels is too restricted to identify the five parameters. An undemanding heuristic method is used to find the five parameters for photovoltaic systems, requiring only the open circuit, maximum power, and short circuit data. The I–V and the P–V curves for a monocrystalline, polycrystalline and amorphous photovoltaic systems are computed from the parameters identification and validated by comparison with experimental ones. Also, the I–V and the P–V curves under the effect of partial shading are obtained from those parameters. The modeling for the converters emulates the association of a DC–DC boost with a two-level power inverter in order to follow the performance of a testing commercial inverter employed on an experimental system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO: Introdução: Uma meta-análise recente demonstrou que uso adjuvante de ácido zoledrónico (AZ) em mulheres pós-menopáusicas com cancro da mama precoce (CM) conduz a redução do risco de morte por CM em 17%. Investigámos o efeito do estado hormonal (pré [PrM] vs pós-menopausa tardia [PoM]) na remodelação óssea e controlo de doença em mulheres com CM e metástases ósseas (MO) tratadas com AZ e quimioterapia (QT). Métodos: Neste estudo de coorte retrospetivo, colhemos variáveis clinico-patológicas e quantificámos o telopéptido N-terminal (NTX) urinário e marcadores tumorais (MT) séricos em mulheres com CM e MO tratadas com QT e AZ. As doentes foram divididas em PrM (<45 anos) e PoM (>60 anos). Endpoints do estudo: variação do NTX, CA15.3 e CEA nos meses 3, 6 e 9, tempo até falência de QT de primeira-linha e sobrevivência. Quando apropriado foram usados os testes de Wilcoxon rank-sum, modelo de efeitos lineares mistos, teste log-rank e modelo de Cox. Resultados: Quarenta doentes foram elegíveis para análise (8 PrM e 32 PoM). Depois da introdução de AZ e QT, os níveis de NTX e MT caíram no coorte global. O perfil de resposta não diferiu entre grupos no mês 3 ou em tempos posteriores (valor-p para interação tempo-estado hormonal no mês 3=0.957). Ademais, o perfil de resposta dos MT também não diferiu entre grupos. O tempo mediano até falência de primeira-linha de QT em PrM e PoM foi de 15.2 e 17.4 meses, respetivamente. Não foi identificada diferença significativa entre grupos, quer em análise univariada quer após controlo para envolvimento visceral (p=0.399 e 0.469, respetivamente). Igualmente, não houve diferenças em termos de sobrevivência. Conclusões: Neste coorte, não foram identificadas diferenças no controlo de NTX ou MT em função do estado menopausico. Igualmente, não foi identificada diferença no tempo até falência de primeira-linha de CT ou sobrevivência.----------- ABSTRACT: Background: A recent meta-analysis showed that the adjuvant use of zoledronic acid (ZA) in postmenopausal women with early breast cancer (BC) leads to a reduction in the risk of breast cancer death by 17%. We investigated the effect of the hormonal status (pre [PrM] vs late post menopause [PoM]) on bone turnover and disease control among women with BC and boné metastases (BM) treated with ZA and chemotherapy (CT). Methods: In this retrospective cohort study, we collected clinicopathologic variables, urinary Nterminal telopeptide (NTX) and serum tumor marker levels from women with BC and BM treated with CT and ZA. Patients were divided in PrM (<45 years) and PoM (>60 years). Study endpoints were NTX, CA15.3 and CEA variation at 3, 6 and 9 months, and time to first-line CT failure and survival. We performed multilevel mixed-effects linear regression models to assess the variation of repeated measures and cox regression models for time to event outcomes. Results: Forty patients were eligible for analysis (8 PrM and 32 PoM). After introduction of ZA and CT, NTX and tumor markers declined in the overall cohort. Response profile was similar between menopausal groups at month 3 and at later time points (p-value for time-hormonal status interaction at month 3=0.957). Furthermore, tumor markers response profile was also equal between groups. Median time to first-line CT failure in PrM and PoM women was 15.2 and 17.4 months, respectively. No significant difference between groups was found, either using a univariate analysis or after controlling for visceral disease involvement (p=0.399 and 0.469, respectively). Likewise, no differences in survival were found. Conclusions: In this cohort, no differences were found in terms of NTX or tumor markers control according to menopausal status. Similarly, no difference in time to first-line CT failure or survival was found.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A incompreensão sobre como funcionam os processos que conduzem às decisões na União Europeia (UE) e que representam hoje, principalmente, uma panóplia legislativa com impacto significativo no dia-a-dia dos cidadãos, das empresas e dos governos, é reconhecida pela própria Comissão Europeia a par duma existente desconfiança das pessoas na política, e o seu consequente distanciamento entre elas e as instituições. Para esta situação muito contribui o complexo xadrez de instituições da UE (Comissão Europeia, Parlamento Europeu, Conselho Europeu, Conselho da União Europeia, Tribunal de Justiça da União Europeia, Banco Central Europeu, Comité das Regiões, agências da União Europeia, etc.) com fronteiras pouco claras entre si no que respeita às áreas de intervenção, responsabilidades e competências, assim como a forma como são nomeados e/ou eleitos os seus representantes. Todas estas dúvidas por parte dos cidadãos acentuam não só um legítimo desconhecimento pelos mecanismos de decisão, pois variam de instituição para instituição e a informação e regras de funcionamento encontram-se dispersas por vários documentos, bem como enraízam uma desconfiança sobre os verdadeiros interesses nas decisões tomadas e, ainda, sobre os actores que nelas estão envolvidos. Procurámos no nosso estudo, em primeiro lugar, estabelecer a relação entre os processos de decisão na UE e a forma como com ele interagem redes de partes interessadas – stakeholders. Em segundo lugar, à luz dum quadro teórico desenvolvido em torno do estudo do ciclo político das decisões no quadro comunitário, tentámos fazer a correlação deste com um processo de decisão específico. Foi nossa intenção perceber se o decurso e o envolvimento dos stakeholders no processo de decisão estudado se coaduna com a bibliografia que aponta os processos de decisão da UE como sendo abertos e inclusivos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An energy harvesting system requires an energy storing device to store the energy retrieved from the surrounding environment. This can either be a rechargeable battery or a supercapcitor. Due to the limited lifetime of rechargeable batteries, they need to be periodically replaced. Therefore, a supercapacitor, which has ideally a limitless number of charge/discharge cycles can be used to store the energy; however, a voltage regulator is required to obtain a constant output voltage as the supercapacitor discharges. This can be implemented by a Switched-Capacitor DC-DC converter which allows a complete integration in CMOS technology, although it requires several topologies in order to obtain a high efficiency. This thesis presents the complete analysis of four different topologies in order to determine expressions that allow to design and determine the optimum input voltage ranges for each topology. To better understand the parasitic effects, the implementation of the capacitors and the non-ideal effect of the switches, in 130 nm technology, were carefully studied. With these two analysis a multi-ratio SC DC-DC converter was designed with an output power of 2 mW, maximum efficiency of 77%, and a maximum output ripple, in the steady state, of 23 mV; for an input voltage swing of 2.3 V to 0.85 V. This proposed converter has four operation states that perform the conversion ratios of 1/2, 2/3, 1/1 and 3/2 and its clock frequency is automatically adjusted to produce a stable output voltage of 1 V. These features are implemented through two distinct controller circuits that use asynchronous time machines (ASM) to dynamically adjust the clock frequency and to select the active state of the converter. All the theoretical expressions as well as the behaviour of the whole system was verified using electrical simulations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a comprehensive comparison of a current-source converter and a voltage-source converter for three-phase electric vehicle (EV) fast battery chargers. Taking into account that the current-source converter (CSC) is a natural buck-type converter, the output voltage can assume a wide range of values, which varies between zero and the maximum instantaneous value of the power grid phase-to-phase voltage. On the other hand, taking into account that the voltage-source converter (VSC) is a natural boost-type converter, the output voltage is always greater than the maximum instantaneous value of the power grid phase-to-phase voltage, and consequently, it is necessary to use a dc-dc buck-type converter for applications as EV fast battery chargers. Along the paper is described in detail the principle of operation of both the CSC and the VSC for EV fast chargers, as well as the main equations of the power theory and current control strategies. The comparison between both converters is mainly established in terms of the total harmonic distortion of the grid current and the estimated efficiency for a range of operation between 10 kW and 50 kW.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper proposes a multifunctional converter to interface renewable energy sources (e.g., solar photovoltaic panels) and electric vehicles (EVs) with the power grid in smart grids context. This multifunctional converter allows deliver energy from the solar photovoltaic panels to an EV or to the power grid, and exchange energy in bidirectional mode between the EV and the power grid. Using this multifunctional converter are not required multiple conversion stages, as occurs with the traditional solutions, where are necessary two power converters to integrate the solar photovoltaic system in the power grid and also two power converters to integrate an off-board EV battery charger in the power grid (dc-dc and dc-ac power converters in both cases). Taking into account that the energy provided (or delivered) from the power grid in each moment is function of the EV operation mode and also of the energy produced from the solar photovoltaic system, it is possible to define operation strategies and control algorithms in order to increase the energy efficiency of the global system and to improve the power quality of the electrical system. The proposed multifunctional converter allows the operation in four distinct cases: (a) Transfer of energy from the solar photovoltaic system to the power grid; (b) Transfer of energy from the solar photovoltaic system and from the EV to the power grid; (c) Transfer of energy from the solar photovoltaic system to the EV or to the power grid; (d) Transfer of energy between the EV and the power grid. Along the paper are described the system architecture and the control algorithms, and are also presented some computational simulation results for the four aforementioned cases. It is also presented a comparative analysis between the traditional and the proposed solution in terms of operation efficiency and estimated cost of implementation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a three-phase three-level fast battery charger for electric vehicles (EVs) based in a current-source converter (CSC). Compared with the traditional voltage-source converters used for fast battery chargers, the CSC can be seen as a natural buck-type converter, i.e., the output voltage can assume a wide range of values, which varies between zero and the maximum instantaneous value of the power grid phase-to-phase voltage. Moreover, using the CSC it is not necessary to use a dc-dc back-end converter in the battery side, and it is also possible to control the grid current in order to obtain a sinusoidal waveform, and in phase with the power grid voltage (unitary power factor). Along the paper is described in detail the proposed CSC for EVs fast battery charging systems: the circuit topology, the power control theory, the current control strategy and the grid synchronization algorithm. Several simulation results of the EV fast battery charger operating with a maximum power of 50 kW are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a novel concept of unidirectional bridgeless combined boost-buck converter for electric vehicles (EVs) battery chargers. The proposed converter is composed by two power stages: an ac-dc front-end converter used to interface the power grid and the dc-link, and a dc-dc back-end converter used to interface the dc-link and the batteries. The ac-dc converter is a bridgeless boost-type converter and the dc-dc converter is an interleaved buck-type converter. The proposed converter operates with sinusoidal grid current and unitary power factor for all operating power levels. Along the paper is described in detail the proposed converter for EV battery chargers: the circuit topology, the different stages describing the principle of operation, the power control theory, and the current control strategy, for both converters. Along the paper are presented several simulation results for a maximum power of 3.5 kW.